Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “insulation damage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Spread Spectrum Time Domain Reflectometry (SSTDR) and Frequency Domain Reflectometry (FDR) for Detection of Cable Anomalies Using Machine Learning

Cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages. A related technology that has found some acceptance in the aircraft and rail industry is spread spectrum time domain reflectometry (SSTDR). This technology has been implemented with a custom commercial instrument by LiveWire Innovation Inc. that is designed to operate on live cables up to 1000 volts. One of the main conclusions of a previous effort was that cable reflectometry plots can be difficult for humans to analyze due to baseline noise, low or noisy anomaly response peaks, or large responses from cable ends. Detection of cable anomalies for many of these frequencies and test conditions was challenging for manual analysis. This presented an ideal opportunity for ML analysis to distinguish undamaged cable indications from anomalous cable indications. This research discusses application of machine learning (ML) to reflectometry cable test methods. The goal was to assess feasibility to distinguish undamaged cable reflectometry responses from damaged or anomalous cable reflectometry responses. The assessment considered the 3 instruments, multiple frequency bandwidths from each instrument, multiple cable anomalies and test conditions, and both supervised and unsupervised ML approaches. Although approaches and analysis methods were not identical or directly comparable, both outputs were encouraging. The unsupervised prediction weighted accuracy was assessed by instrument and by frequency. It performed better at high frequencies with the highest prediction accuracy of 0.84 for the higher frequency FDR, 0.79 for the 48-MHz LiveWire SSTDR, and 0.77 for 300-MHz PNNL SSTDR. The initial weighted accuracy average across all frequencies for using supervised ML was 0.56 to 0.68. The supervised analysis was repeated with noisier training data removed resulting in weighted accuracies of 0.69 to 0.87. These weighted accuracies are not directly comparable due to differences in the supervised and unsupervised analysis details but do indicate an encouraging trend. Even with limited and unbalanced data, strong prediction accuracies seem encouraging for further work including more data under a wider range of conditions.

42 ENGINEERING↗

Enhanced through-thickness electrical conductivity and lightning strike damage response of interleaved vertically aligned short carbon fiber composites

Through-thickness electrical conductivity of carbon fiber reinforced polymers (CFRPs) is a key characteristic that determines the severity of lighting strike-induced damage. Carbon Fibers (CFs) are inherently electrically conductive and therefore provide high conductivity in the direction of the fiber orientation. However, electrical conductivities through the thickness and orthogonal to the CF orientation in CFRPs are governed by the insulating polymer matrix present between CFs. Here, in this work, through the thickness alignment of short CFs in between layers of CFRP laminates is demonstrated to improve the through-thickness electrical conductivity. Composites with interleaved vertically aligned short CF fibers (<150 μm) will be referred as V-fiber composites hereafter. The effect of the V-fiber on the lightning strike damage is evaluated against an artificial lightning strike of 100 kA (modified waveform A of SAE ARP-5412B standard). The improved through-thickness electrical conductivity of CFRP laminates (1.15 S/cm) through vertical alignment of short CFs was compared to reference CFRP laminates (0.13 S/cm) and was found to dissipate the artificial lightning strike current more efficiently. The surface damage after the artificial lightning strike in the V-fiber composites was reduced to 12.69 cm 2 compared to the reference CFRP surface damage of 57.67 cm 2 , a 78% reduction. It was also demonstrated that Joule heat generated due to lightning strike on the composites was significantly less than the reference sample using infrared (IR) thermography. A high retention (up to 78%) of flexural properties (modulus and strength) was observed in V-fiber composites post lightning strike impact as compared to only 47% retention in the reference panel.

42 ENGINEERING↗

Self-healing barrier films for vacuum insulation panels

A self-healing vacuum insulation panel and a method of manufacture are provided. The vacuum insulation panel includes a self-healing, multi-layer barrier film including a separator between a curing agent and a curable resin. Upon damage to the separator, the curing agent penetrates the separator due to a pressure differential across the barrier film and reacts with the curable resin to seal any cuts or punctures. The curing agent and the curable resin can be selected to have long term stability and a short reaction time with no need for external stimuli. As a result, the multi-layer barrier film can retain the internal vacuum and maintain a desirably low thermal conductivity using low-cost, commercially available epoxies and curing agents.

Biswas, Kaushik↗

Photonic curing for innovative fabrication of flexible metal oxide optoelectronics

Abstract Flexible optoelectronics, based on non-planar substrates, hold promise for diverse applications such as wearables, health monitors, and displays due to their cost-effective manufacturing methods. Despite the superior properties of metal oxides, the challenge of processing them at high temperatures incompatible with plastic substrates necessitates innovative annealing approaches. Photonic curing, which delivers microsecond to millisecond broadband (200–1500 nm) light pulses on a sample, emerges as a viable solution. Depending on the optical properties, the targeted film absorbs the radiant energy resulting in rapid heating while the transparent substrate absorbs a minimal amount of light and remains at ambient temperature. The light intensity can be high, but since the light pulse is short, the total energy absorbed by the sample remains low and will not damage the plastic substrate. This perspective explores the innovative application of photonic curing to fabricate flexible metal oxide optoelectronics, including thin-film transistors, metal–insulator–metal devices, solar cells, transparent conductors, and Li batteries, emphasizing the conversion of sol–gel precursors to metal oxides. However, this technique was initially developed for sintering metal nanoparticles to conductive patterns and poses intriguing challenges in explaining its mechanism for metal oxide conversion, especially considering the limited absorption of visible light by most sol–gel precursors. The review delves into UV-induced photochemistry, common flexible metal-oxide optoelectronic components, and non-intuitive distinctions between photonic curing and thermal annealing. By elucidating the distinctive role of photonic curing in overcoming temperature-related challenges and advancing the fabrication of flexible metal oxide optoelectronics, this perspective offers valuable insights that could shape the future of flexible optoelectronics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multifamily Air Leakage Evaluation: A Modular Case Study

The purpose of this case study is to compare the air leakage rates of modular and site-built multifamily dwelling units. The methods, materials, and equipment were observed to be very similar in the modular and site-constructed units in this case study. The installation quality of building envelope measures such as insulation and air barrier appeared to be better for modular construction, because they were installed in a controlled, factory setting. Through field observations, we identified cosmetic damage to the envelope of modular units following transport to the building site, but with no resulting significant air leakage pathways. However, we did see air leakage pathways resulting from field modifications to the envelope of modular units to accommodate structural and mechanical connections. We found that the extensive use of through-wall HVAC systems, combined with the transport, placement, and rework of modular units may compromise the high-quality envelope installation and airtightness observed in the factory without careful planning and/or design. Opportunities for improvement identified from the tested modular dwelling units include minimizing and optimally locating penetrations, pre-cutting and detailing penetrations at the factory where possible, properly sealing field modifications, and using split HVAC systems in place of through-wall packaged systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Return on Investment and Sustainability of HVDC Links: Role of Diagnostics, Condition Monitoring, and Material Innovations

HVDC cable systems are becoming an upscaled technical option, compared to AC, because of various factors, including easier interconnections, lower losses, and longer transmission distances. In addition, renewables providing direct DC energy, electrified transportation, and aerospace where DC can be favored because of higher carried specific power all point in the direction of broad future usage of HV and MV DC links. However, contrary to AC, there is little return from on-field installation as regards long-term cable reliability and aging processes. This gap must be covered by intensive research, and contributing to this research is the purpose of this paper. The focus is on key points for HVDC (and MVDC) cable reliability and sustainability, from design modeling able to account for voltage transients and extrinsic aging (such as that caused by partial discharges) to the impact of aging on insulation conductivity (which rules the electric field distribution, thus aging rate). Also, recyclable and nanostructured materials, as well as health conditions, are considered. It is shown how cable design can account for accelerated aging due to voltage transients, as well as for aging-time dependence of conductivity, and how design can be free of extrinsic aging caused by PDs. Algorithms for health condition evaluations, which have additional value in a relatively new technology such as HVDC polymeric cables, are applied to insulation system aging under partial discharges, showing how they can provide an indication of insulation degradation globally or locally (weak spots) and of possible maintenance times. All of this can effectively contribute to reducing the risk of major cable breakdown and damage under operation, which would significantly affect the return on investment (ROI).

Montanari, Gian Carlo (ORCID:0000000320258693)↗

Enhanced lightning strike protection using vertically oriented carbon fiber melded with conventional carbon fiber-reinforced composite and its validation through damage analysis

Lightning strike protection (LSP) is one of the prime factors in aerospace and wind industries concerning safety, enhanced service life, and reduced downtime. To ensure better LSP, high electrical conductivity is required to dissipate the current, which is always a challenge for polymer composites due to the inherent insulating nature of the polymer matrix. Conventional carbon fiber-reinforced composites (CFRP) offer electrical conductivity in the planar direction while the vertical i.e. through-thickness conductivity still remains a challenge. Having been motivated by this fact, we have fabricated CFRP interleaved with vertically oriented CF (Z-fiber) for the lightning strike test (100 kA). A paint was applied to mimic the actual service condition of the composite laminates. We have prepared two Z-fiber composites: (a) Z-1 containing one Z-fiber layer on the top along with conventional CF layers and (b) Z-5 containing five interleaved Z-fiber layers and compared the properties with conventional CFRP (Z-0). Interestingly, even a single Z-fiber layer (Z-1) showed lower damage (visual damage diameter 22 mm) than Z-0 (visual damage diameter 26 mm). Z-5 displayed the lowest damage (visual damage diameter 16.7 mm), which was further confirmed by cross-sectional optical microscopy. Improved LSP was attributed to the higher through-thickness electrical conductivity in the case of Z-5 (9 times with respect to Z-0) reflecting a lower electrical anisotropy for Z-fiber composites. The residual mechanical property after the lightning test was analyzed through the flexural test, and the retention of flexural strength and modulus was 66% and 86%, respectively for Z-5 showing a significant improvement in comparison to Z-0 (>40% for both).

Saha, Subhabrata↗

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design, Construction, and Field Validation of a Blown-In Fiberglass Wall System in a Cold, Wet, and Windy Climate

In the Native Village of Tununak, located on Nelson Island in Southwest Alaska,buildings are exposed to wind-driven rain and snow throughout the year. The Cold Climate Housing Research Center (CCHRC) and Knauf Insulation partnered with the community in 2018 to design a residence for a public safety officer. Construction began in fall 2021 and is scheduled to conclude in summer 2022. The house will use integrated trusses with floor, attic, and wall cavities filled with blown-in fiberglass insulation. Hygrothermal models of the building envelope system demonstrate that the high ambient moisture load will wet the outer edges of the insulation annually regardless of the extent and integrity of exterior weather sealing measures; blown-in fiberglass is expected to be more resilient to this wetting than blown-in cellulose. To verify this, researchers will embed temperature, relative humidity, and moisture sensors in the two windward walls of the house to monitor the ability of the blown-in fiberglass insulation to dry out after wetting events that may have occurred during the transport of the insulation to the building site, storage of the insulation on site, construction process, or after installation in the wall. Sensors will remain in place for two years,documenting the wall's performance over time and verifying the design's potential for use in buildings located in climates where the chance for moisture damage is high. Here, we describe the wall system , design criteria, and the results from the hygrothermal modeling. We share details on the monitoring system's components and the planned management and analysis of data. Finally, we explain how the experiences and data from this project will inform future builds in similar locations.

building design↗

Flexible Fabric-Based IDC Sensors for Conformal Curved Surface Applications

Interdigital capacitor (IDC) sensors are attractive in-situ sensors that can be used to measure permittivity variations in materials. Such sensors could be powerful enablers for cable insulation aging detection. Since insulation aging is correlated with a change in its material permittivity an IDC can measure that change via its measured capacitance. A new thin, flexible fabric-based IDC sensor is introduced for application on conformal curved surfaces such as an electrical cable surface. A multielectrode IDC and its backplane were fabricated using conductive copper polyester taffeta fabrics that were adhesively bonded to nonconductive polyester fabric. The sensor because of its soft flexible structure eliminates the problem of sensor conductor damage which is common for printed circuit board (PCB) type sensors when conformed to the surface of a cable. It also significantly reduces the airgap between the electrodes and the surface that they must contact in order to measure the capacitance. Airgap reduction and consistency are important in order to accurately predict permittivity variations in cable insulation material due to aging. Both PCB-based sensors and the new fabric-based sensors were built and tested on unaged cables and cables that underwent accelerated aging. Results demonstrate the proposed advantages of the novel fabric-based IDC sensor.

interdigital capacitor sensor, IDC, NDE, PCB senso↗

A High Intensity Spin-Polarized Electron Photogun to Drive a Polarized Positron Source

A photogun to generate a high-intensity, highly spin-polarized electron beam >90% with unprecedented charge lifetime in the kilocoulomb range is envisioned at JLab for a proposed Ce+BAF polarized positron beam source. The electron photogun is expected to provide a CW beam of >1 mA for a month without intervention. A limiting factor is ion-back bom-bardment on the strained-superlattice GaAs-photocathode which can be reduced by improving the photogun vacuum or biasing the anode. Additionally, increasing the laser spot size can help mitigate ion-induced damage. However, eventually the laser size becomes too large for the photogun electrode. An envisioned photogun design will incorporate larger electrodes to accommodate larger and off-center laser spot sizes. Compatible larger conical insulators which operate >300 kV for beam injection into a Beta~1 SRF booster are also necessary.

Hernandez Garcia, Carlos↗

Thermal shock resistance of lightweight cements developed for geothermal conditions

Cements are a critical component in well construction, as they act to prevent well fluid and gas escape, prevent corrosion of the casing, and strengthen the wellbore to prevent deformation. Under the high temperature/pressure conditions common in geothermal systems, the injection of cold water for energy production is expected to induce cyclic damage to the borehole cement through the rapid temperature fluctuations. These “thermal shocks” are expected to cause casing shrinkage, annulus formation, and cement tensile stresses. To understand the effect of cold water injection on the wellbore environment, a set of rock-cement-steel samples were created to simulate the structure of a geothermal well. Lightweight thermally-insulating cement blends were tested under thermal shock conditions in this study. In each test, the samples were pressurized to an effective pressure of ~3.5 MPa and placed at high temperatures. Thermal shocks were performed by injecting cold water (~10-15 °C) through the samples at a constant rate while keeping the samples at high temperatures until the sample temperature stopped decreasing and deformation ceased. Eight thermal shock tests were conducted with each sample – two at 100 °C and six at 200 °C. Post-tests analysis was then conducted by cutting open each sample to examine the damage in each component of the simulated wellbore. Experimental results suggest that all samples experienced similar degrees of axial and lateral contraction during cold water injection, but for the most part this contraction is recoverable when injection halts. Post-test analysis revealed that fly ash cenosphere pre-treatment had the best effect on improving thermal shock resistance in the cement blends. Thermomechanical modeling of likely stress paths experienced by the cements during heating/cooling cycles shows that elasto-plastic cement constitutive behavior results in most plastic strain occurring during the initial heating steps, with mostly elastic strain occurring during the thermal shock cycles. In conclusion, this agrees with experimental evidence, suggesting that cement damage from shocking occurs via other mechanisms such as chemical alteration, corrosion, and fatigue.

36 MATERIALS SCIENCE↗

High‐Efficiency Magnon‐Mediated Magnetization Switching in All‐Oxide Heterostructures with Perpendicular Magnetic Anisotropy

Abstract The search for efficient approaches to realize local switching of magnetic moments in spintronic devices has attracted extensive attention. One of the most promising approaches is the electrical manipulation of magnetization through electron‐mediated spin torque. However, the Joule heat generated via electron motion unavoidably causes substantial energy dissipation and potential damage to spintronic devices. Here, all‐oxide heterostructures of SrRuO 3 /NiO/SrIrO 3 are epitaxially grown on SrTiO 3 single‐crystal substrates following the order of the ferromagnetic transition metal oxide SrRuO 3 with perpendicular magnetic anisotropy, insulating and antiferromagnetic NiO, and metallic transition metal oxide SrIrO 3 with strong spin–orbit coupling. It is demonstrated that instead of the electron spin torques, the magnon torques present in the antiferromagnetic NiO layer can directly manipulate the perpendicular magnetization of the ferromagnetic layer. This magnon mechanism may significantly reduce the electron motion‐related energy dissipation from electron‐mediated spin currents. Interestingly, the threshold current density to generate a sufficient magnon current to manipulate the magnetization is one order of magnitude smaller than that in conventional metallic systems. These findings suggest a route for developing highly efficient all‐oxide spintronic devices operated by magnon current.

Zheng, Dongxing↗

Role of electrolyte in silicon electrolyte interface stabilization

Transition metal ion dissolution was long thought to be the reason for poor cycling performance in Lithium ion batteries cycled to a high voltage, but since the anode SEI is electrochemically insulating, the mechanism for transition metal mediated SEI decomposition in unclear. Our results show that acidic species such as F 2 PO 2 H generation on the cathode side and their subsequent crossover reactions with the SEI components damaging it could more likely be a major factor to capacity fade.

25 ENERGY STORAGE↗

Thermal Assessment and In-Situ Monitoring of Insulated Gate Bipolar Transistors in Power Electronic Modules: Preprint

Insulated gate bipolar transistor (IGBT) power modules are devices commonly used for switching of high voltages and currents. Usage and environmental conditions can cause these power modules to degrade over time, and this gradual process may eventually lead to catastrophic failure of the device. This degradation process may cause some early performance symptoms related to the state of health of the power module, making it possible to detect reliability degradation of the IGBT module. Testing can be used to accelerate this process, permitting a rapid determination of whether specific declines in device reliability can be characterized. In this study, thermal cycling was conducted on multiple power modules simultaneously in order to assess the effect of thermal cycling on the degradation of the power module. In-situ monitoring of temperature was performed from inside each power module using high temperature thermocouples. Device imaging and characterization was performed along with temperature data analysis, to assess failure modes and mechanisms within the power modules. While the experiment was aimed to assess the potential damage effects of thermal cycling on die attach, results indicated that wirebond degradation was the life limiting failure mechanism.

33 ADVANCED PROPULSION SYSTEMS↗

PV backsheets survey protocol: A framework for geo-spatial field surveys for bulk material characterization and reliability analysis applied across 41 PV systems

As widespread adoption of photovoltaic (PV) technologies continues, understanding the lifetime of modules is paramount to the viability of the industry as an environmentally conscious alternative to traditional energy generation. Although power degradation can affect the total energy production of a module over its lifetime, module safety failures necessitate the removal of a module leading to a loss of not only the particular asset, but the earning potential of the device. Therefore, it is critical to ensure that the components that provide essential safety functions for PV module operate for their entire rated lifetime. PV backsheets provide necessary electrical insulation to the completed device and failure of this component is cause for a immediate removal of the module. Degradation of the PV module backsheet has led to module safety failures in large-scale installations, costing millions of dollars in damages and lost potential revenue. The spatio-temporal degradation of fielded PV modules is important to study in order to identify which modules within installations are experiencing the greatest exposure conditions and in turn have the highest chance of failure. This paper describes a comprehensive field survey protocol developed for monitoring PV module backsheet performance using solely non-destructive methods in commercial PV fields. The protocol establishes a field naming convention, sampling method, data handling requirements, and measurement procedures. By ensuring consistent data collection practices, the field survey protocol enables research groups to obtain data of uniform quality on backsheet performance over multiple years and locations. In this study, the developed protocol was implemented at forty-one PV sites. Eight different types of airside layer backsheet materials including poly(vinylidene fluoride) (PVDF), acrylic PVDF, poly(tetrafluoroethylene-co-hexafluoropropylene-co-vinylidene fluoride) (THV), poly(vinyl fluoride) (PVF), poly(ethylene terephthalate) (PET), fluoroethylene vinyl ether (FEVE), polyethylene naphthalate (PEN), and glass were identified using attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. The field survey results show that the spatial distribution of degradation indicators are non-uniform within a particular module, individual site, and across site locations. The degradation of PV modules increased in severity for modules mounted at the edge of rows (across a field) and near the junction box (within a module). This study demonstrates the sensitivity of material performance to exposure length across different materials and climates.

14 SOLAR ENERGY↗

Investigation of the Anisotropy of Y-Ba-Cu-O Thin Films With Photoemission Electron Microscopy

Understanding the anisotropy in the electrical properties of YBa2Cu3O7-δ (YBCO) is important for understanding the fundamental mechanism of superconductivity in unconventional superconductors. Additionally it is also essential for achieving uniform and controllable critical currents and resistances in YBCO Josephson junctions. Here, this study correlates work function measurements of different intrinsic regions on YBCO thin films, obtained through PhotoEmission Electron Microscopy (PEEM), with in plane tunneling data and helium ion imaging. YBCO thin films, 40 nm in thickness, were selectively irradiated with 300 keV helium using a Pelletron to investigate the effects of irradiation compared to unirradiated regions. Post-irradiation PEEM images revealed distinct contrasts between irradiated and non-irradiated regions, suggesting a metal-to-insulator transition. In non-irradiated areas, a domain pattern was detected, showing a 25 meV difference in work function, attributed to CuO and BaO rich surface regions. A similar domain structure was observed using high-resolution helium ion imaging; however, the helium ion beam can damage the YBCO, making PEEM a valuable non-destructive alternative. This work highlights the correlation between PEEM measurements and in-plane tunneling properties of YBCO, providing insights into material orientation and its impact on Josephson junction performance. Furthermore, it offers a non-destructive approach to understanding the anisotropy of cuprate materials, its superconducting properties, and the factors affecting Josephson junction performance.

Qu, Rochelle Y. [Univ. of California, Riverside, C↗

MAGNETICALLY SUSPENDED CANNED ROTOR PUMPS FOR THE INTEGRAL MOLTEN SALT REACTOR

This project developed a molten salt pump design for small modular reactors, concentrated solar, and Gen IV nuclear reactors with a magnetically levitated rotor that can operate at temperatures of up to 700 °C. This eliminates the need for rotating seals and roller element bearings which require maintenance and are prone to failure. The pump design is also more compact than existing molten salt pump designs which require long shafts to thermally isolate the electric motor. The aims of the project are to: 1) design and test the molten salt pump, 2) develop and test a high temperature position sensor needed for magnetic bearing control, and 3) develop and test high temperature coil fabrication methods for electric motor and magnetic bearing fabrication. To develop the high temperature coils, conductor materials were analyzed for oxidation, diffusion, cladding, and resistivity. Of the candidate conductor materials that met the requirements, silver was chosen. The long-term impact of radiation on silver resistivity was analyzed by developing a model of a generic molten salt fast reactor to model the conductor irradiation in worst case scenarios. The analysis showed that increased resistivity due to transmutation of silver decreases exponentially with the reactor reflector thickness. Different electrical insulation materials were tested and the final high temperature coils developed were able to withstand conductor to ground voltages up to 1800 V before insulation breakdown. Magnetic bearings require high-precision high-speed measurements of the rotor position to operate. Current commercial position sensors can only operate up to 550 °C so a novel position sensor was developed that can operate up to 800 °C. These sensors were also designed to measure the position of the metallic rotor through a thin metallic corrosion barrier that protects that coils, insulation, and magnetic cores so that the salt containment barrier does not have any penetrations. The high-temperature sensor was tested and had comparable performance to commercially available inductive position sensors. The sensor design and signal processing has led to several invention disclosures. The magnetically levitated molten salt pump design was completed and analyzed. The chloride salt test loop at Oak Ridge National Laboratory was chosen to test the pump and the pump hydraulics and power were designed for the test loop flow and pressure requirements. Classes of motor designs that do not utilize permanent magnetic were considered for the high-temperature motor. After extensive analysis of their performance, a synchronous reluctance motor was chosen for the pump. The design was refined and analyzed to optimize performance. The magnetic bearings were designed to meet the force and frequency requirements necessary to levitate the rotor and reject disturbances from rotor imbalance, motor forces, and hydraulic forces. Compliant mounts for the position sensors were designed that would not damage the ceramic sensor components and maintain sensor alignment over a wide temperature range. A thermal hydraulic analysis of the molten salt coolant flow used to cool the rotor and stator was performed to ensure that the maximum temperature in the rotor and stator will not exceed 725 °C. The corrosion barrier and casing were designed to maintain the salt fluid boundary by using compliant features to absorb large expansion mismatches due to different coefficients of thermal expansion (CTE). Finally, the salt drain and fill systems were designed along with the pump support structure, integration with the test loop, and thermal insulation and heating. Corrosion barrier fabrication experiments were performed to assess using laser cladding to apply a sub-millimeter corrosion barrier to the surface of a Fe-Co-V magnetic core material. The cladding method showed minimal mixing between materials at their interface and withstood temperature cycling without damage to the cladding. The technology commercialization is focused on the high-temperature position sensors and there has been significant interest from the nuclear industry in utilizing these sensors along with some interest from the aerospace industry. The project also led to a research collaboration with a fusion energy industrial partner to study barriers to scaling the pump design from the kW size to the MW size. This research collaboration will also study methods to create high-temperature coils that have conductor to ground breakdown voltages above 5 kV. The successful development of high-temperature electromagnetic coils and high-temperature position sensors greatly increases the temperature limits for electromagnetic devices that don’t rely on permanent magnets. This includes electric motors, magnetic bearings, linear actuators, rotary position and velocity sensing, actuated valves, and generators to name a few. This will fill a current need in molten salt reactors, concentrated solar, and fusion energy for these critical peripheral devices needed for practical reactor designs that do not currently have commercial solutions.

Hines, J Wesley↗