Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “instrumental resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Desmearing small-angle scattering data by central moment expansions

This article proposes a robust method for desmearing 1D small-angle scattering (SAS) intensity profiles. Using the central-moment-expansion technique, smearing in SAS intensity profiles is achieved in a model-free manner, eliminating the need for presumptive input during the desmearing. This innovative approach enables data analysis of SAS data without the resolution being convoluted with the structural model, thereby facilitating faster implementation and performance of fitting functions directly from the scattering models.

42 ENGINEERING↗

Converting existing optical detectors into fast x-ray detectors

Here, the very short burn time and small size of burning plasmas created at advanced laser-fusion facilities will require high-spatial-resolution imaging diagnostics with fast time resolution. These instruments will need to function in an environment of extremely large neutron fluxes that will cause conventional diagnostics to fail because of radiation damage and induced background levels. One solution to this challenge is to perform an ultrafast conversion of the x-ray signals into the optical regime before the neutrons are able to reach the detector and then to relay image the signal out of the chamber and into a shielded bunker, protected from the effects of these neutrons. With this goal in mind, the OMEGA laser was used to demonstrate high-temporal-resolution x-ray imaging by using an x-ray snout to image an imploding backlighter capsule onto a semiconductor. The semiconductor was simultaneously probed with the existing velocity interferometry system for any surface reflector (VISAR) diagnostic, which uses an optical streak camera and provided a one-dimensional image of the phase in the semiconductor as a function of time. The phase induced in the semiconductor was linearly proportional to the x-ray emission from the backlighter capsule. This approach would then allow a sacrificial semiconductor to be attached at the end of an optical train with the VISAR and optical streak camera placed in a shielded bunker to operate in a high neutron environment and obtain time-dependent one-dimensional x-ray images or time-dependent x-ray spectra from a burning plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Interactive Spectral Analysis Tool for Chemical Identification and Quantification of Gas-Phase Species in Complex Spectra

A spectral analysis tool has been developed to interactively identify and quantify individual gas-phase species from complex infrared absorbance spectra obtained from laboratory or field data. The SpecQuant program has an intuitive graphical interface that accommodates both reference and experimental data with varying resolution and instrumental lineshape, as well as algorithms to readily align the wavenumber axis of a sample spectrum with the raster of a reference spectrum. Using a classical least squares model in conjunction with reference spectra such as those from the Pacific Northwest National Laboratory (PNNL) gas-phase infrared database or simulated spectra derived from the HITRAN line-by-line database, the mixing ratio of each identified species is determined along with its associated estimation error. After correcting the wavelength and intensity of the field data, SpecQuant displays the calculated mixing ratio versus the experimental data for each analyte along with the residual spectrum with any or all analyte fits subtracted for visual inspection of the fit and residuals. The software performance for multianalyte quantification was demonstrated using moderate resolution (0.5 cm –1 ) infrared spectra that were collected during the time-resolved infrared photolysis of methyl iodide.

Thompson, Christopher J.↗

Design and construction of a compact, high-repetition-rate ultrafast electron diffraction instrument

We present the design and performance of a compact ultrafast electron diffraction instrument. The diffractometer provides a means of examining time-resolved ultrafast dynamical properties of solids. The system’s utilization is discussed in terms of instrument parameters and diffraction data from selected condensed matter samples. Here, the difractometer’s performance is highlighted in terms of detection sensitivity, instrumental temporal resolution, and the electron beam transverse coherence length. Following specific details of the construction, we present a practical discussion of parameters such as repetition rate and provide advice on general construction approaches for laboratory-based, keV ultrafast electron diffractometers. In addition, design guidance for constructing a compact electron gun source that is well-suited for studying diffraction from hard condensed matter is given. A unique data acquisition scheme, utilizing high laser repetition rates, is presented.

47 OTHER INSTRUMENTATION↗

Desmearing two-dimensional small-angle neutron scattering data by central moment expansions

Resolution smearing is a critical challenge in the quantitative analysis of two-dimensional small-angle neutron scattering (SANS) data, particularly in studies of soft-matter flow and deformation using SANS. Here, we present a central moment expansion technique to address smearing in anisotropic scattering spectra, offering a model-free desmearing methodology. By accounting for directional variations in resolution smearing and enhancing computational efficiency, this approach reconstructs desmeared intensity distributions from smeared experimental data. Computational benchmarks using interacting hard-sphere fluids and Gaussian chain models validate the accuracy of the method, while simulated noise analyses confirm its robustness under experimental conditions. Experimental validation using rheological SANS data from shear-induced micellar structures demonstrates the practicality and effectiveness of the proposed algorithm. The desmearing technique provides a powerful tool for advancing the quantitative analysis of anisotropic scattering patterns, enabling precise insights into the interplay between material microstructure and macroscopic flow behavior.

anisotropic scattering spectra↗

Imaging Carrier Dynamics and Transport in Hybrid Perovskites with Transient Absorption Microscopy

In this review, the recent progress in using transient absorption microscopy to image charge transport and dynamics in semiconducting hybrid organic–inorganic perovskites is discussed. The basic principles, instrumentation, and resolution of transient absorption microscopy are outlined. With temporal resolution as high as 10 fs, sub-diffraction-limit spatial resolution, and excited-state structural resolution, these experiments have provided crucial details on charge transport mechanisms that have been previously obscured in conventional ultrafast spectroscopy measurements. Morphology-dependent mapping unveils spatial heterogeneity in carrier recombination and cooling dynamics. By spatially separating the pump and probe beams, carrier transport across grain boundaries has been directly visualized. Further, femtosecond temporal resolution allows for the examination of nonequilibrium transport directly, revealing extraordinarily long-range hot carrier migration. The application of transient absorption microscopy is not limited to hybrid perovskites but can also be useful for other polycrystalline materials in which morphology plays an important role in carrier transport.

36 MATERIALS SCIENCE↗

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4’ field of view (compared to 5’ before). Here, in this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

Peille, Philippe [Centre National d’Etudes Spatial↗

Deep learning based event reconstruction for cyclotron radiation emission spectroscopy

The objective of the cyclotron radiation emission spectroscopy (CRES) technology is to build precise particle energy spectra. This is achieved by identifying the start frequencies of charged particle trajectories which, when exposed to an external magnetic field, leave semi-linear profiles (called tracks) in the time–frequency plane. Due to the need for excellent instrumental energy resolution in application, highly efficient and accurate track reconstruction methods are desired. Deep learning convolutional neural networks (CNNs) - particularly suited to deal with information-sparse data and which offer precise foreground localization—may be utilized to extract track properties from measured CRES signals (called events) with relative computational ease. In this work, we develop a novel machine learning based model which operates a CNN and a support vector machine in tandem to perform this reconstruction. A primary application of our method is shown on simulated CRES signals which mimic those of the Project 8 experiment—a novel effort to extract the unknown absolute neutrino mass value from a precise measurement of tritium β - -decay energy spectrum. When compared to a point-clustering based technique used as a baseline, we show a relative gain of 24.1% in event reconstruction efficiency and comparable performance in accuracy of track parameter reconstruction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Super-resolution surface slope metrology of x-ray mirrors

We present experimental, analytical, and numerical methods developed for reconstruction (deconvolution) of one-dimensional (1D) surface slope profiles over the spatial frequency range where the raw data are significantly perturbed due to the limited resolution of the measurement instrument. We characterize the spatial resolution properties of a profiler with the instrument's transfer function (ITF). To precisely measure the ITF, we apply a recently developed method utilizing test surfaces with 1D linear chirped height profiles of constant slope amplitude. Based on the results of the ITF calibration, we determine parameters of an analytical model for the ITF that is used in the original reconstruction software. Here, we treat surface slope metrology data obtained with the Optical Surface Measuring System (OSMS), using as a sensor an electronic autocollimator (AC) ELCOMAT-3000. The spatial resolution of the OSMS is limited by the size of the AC light-beam-collimating aperture. For the purposes of this investigation, the OSMS is equipped with a circular aperture with a diameter of 2.5 mm. This is a typical arrangement of most AC-based slope profilers developed for surface slope metrology of state-of-the-art x-ray mirrors. Using the example of surface slope metrology of two state-of-the-art elliptically shaped x-ray focusing mirrors, we demonstrate that the developed data reconstruction procedure allows us to significantly improve the accuracy of surface slope metrology with the OSMS over the spatial wavelength range from ~1.6 mm to 7 mm. Thus, the amplitude of the quasi-periodic error characteristic of the deterministic polishing process used appears to be higher by a factor of~2 than is apparent from the rough metrology data. Underestimation of the surface slope errors in this spatial wavelength range can lead to serious errors in the expected performance of x-ray mirrors in synchrotron beamlines, especially at modern light sources utilizing coherent x rays, where the perturbations can lead to increased speckle-like intensity variation.

47 OTHER INSTRUMENTATION↗

DiffLense: a conditional diffusion model for super-resolution of gravitational lensing data

Abstract Gravitational lensing data is frequently collected at low resolution due to instrumental limitations and observing conditions. Machine learning-based super-resolution techniques offer a method to enhance the resolution of these images, enabling more precise measurements of lensing effects and a better understanding of the matter distribution in the lensing system. This enhancement can significantly improve our knowledge of the distribution of mass within the lensing galaxy and its environment, as well as the properties of the background source being lensed. Traditional super-resolution techniques typically learn a mapping function from lower-resolution to higher-resolution samples. However, these methods are often constrained by their dependence on optimizing a fixed distance function, which can result in the loss of intricate details crucial for astrophysical analysis. In this work, we introduce DiffLense , a novel super-resolution pipeline based on a conditional diffusion model specifically designed to enhance the resolution of gravitational lensing images obtained from the Hyper Suprime-Cam Subaru Strategic Program (HSC-SSP). Our approach adopts a generative model, leveraging the detailed structural information present in Hubble space telescope (HST) counterparts. The diffusion model, trained to generate HST data, is conditioned on HSC data pre-processed with denoising techniques and thresholding to significantly reduce noise and background interference. This process leads to a more distinct and less overlapping conditional distribution during the model’s training phase. We demonstrate that DiffLense outperforms existing state-of-the-art single-image super-resolution techniques, particularly in retaining the fine details necessary for astrophysical analyses.

Computer Science↗

Towards performing high-resolution inelastic X-ray scattering measurements at hard X-ray free-electron lasers coupled with energetic laser drivers

High-resolution inelastic X-ray scattering is an established technique in the synchrotron community, used to investigate collective low-frequency responses of materials. When fielded at hard X-ray free-electron lasers (XFELs) and combined with high-intensity laser drivers, it becomes a promising technique for investigating matter at high temperatures and high pressures. This technique gives access to important thermodynamic properties of matter at extreme conditions, such as temperature, material sound speed, and viscosity. The successful realization of this method requires the acquisition of many identical laser-pump/X-ray-probe shots, allowing the collection of a sufficient number of photons necessary to perform quantitative analyses. Here, a 2.5-fold improvement in the energy resolution of the instrument relative to previous works at the Matter in Extreme Conditions (MEC) endstation, Linac Coherent Light Source (LCLS), and the High Energy Density (HED) instrument, European XFEL, is presented. Some aspects of the experimental design that are essential for improving the number of photons detected in each X-ray shot, making such measurements feasible, are discussed. A careful choice of the energy resolution, the X-ray beam mode provided by the XFEL, and the position of the analysers used in such experiments can provide a more than ten-fold improvement in the photometrics. The discussion is supported by experimental data on 10 µm-thick iron and 50 nm-thick gold samples collected at the MEC endstation at the LCLS, and by complementary ray-tracing simulations coupled with thermal diffuse scattering calculations.

36 MATERIALS SCIENCE↗

Rapid Fabrication of High Frame Rate Multichannel FTIR Spectrometers

Spectrally resolved signals in the short- to mid-wave infrared (SWIR/MWIR) bands at high-temporal resolution are critical for many national security remote sensing missions. Currently available off the shelf technology can achieve either high temporal resolution or high spectral resolution, but rugged instruments that can achieve both simultaneously remain mostly in the realm of one-off R&D projects. This report documents efforts to demonstrate a new technique for designing and building high resolution, high framerate multichannel FTIR (MC-FTIR) spectrometers that operate in the SWIR/MWIR bands. The core optical element in a MC-FTIR spectrometer is an array of statically-tuned lamellar grating interferometers (LGI). In the original MC-FTIR work these arrays were fabricated using a synchrotron x-ray lithography method. We proposed to instead fabricate these LGI arrays using multiphoton lithography (MPL), a 3D printing technique that can fabricate meso-scale structures with sub-micron precision. Although we were able to fabricate LGI arrays of sufficient size using MPL, the realized optical surfaces had unsuitably high optical form errors, precluding their use in a fieldable instrument. Further advancement in MPL technology may eventually enable fabrication of interferometer-grade LGI arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of plane wavefront Fizeau interferometers in power spectral density measurements with tilted plane optics

Binary pseudo-random array (BPRA) test samples are useful devices for calibrating the instrument transfer function (ITF) of Fizeau interferometers, interferometric microscopes, and other optical and non-optical surface and wavefront metrology instruments. The intrinsic white noise character of the power spectral density (PSD) function of the BPRA pattern simplifies the extraction of the ITF from the measured PSD. The ITF determined in a dedicated calibration experiment can be used to reconstruct the surface height profile from the measured data, effectively enhancing the instrument’s spatial resolution. For a high confidence reconstruction procedure, a reliable analytical model of the IFT is desirable. Usually, the model accounts for the contributions to the ITF related the imperfections of the instrument’s optical and detector systems. Here, we experimentally demonstrate that in the case of surface height metrology with Fizeau interferometers, the PSD measurements and, therefore, the efficacy of the ITF calibration of the tool, are strongly affected by the instrument data acquisition and processing procedures, as well as by the shape of the optic under test and its alignment with respect to the interferometer.

Yashchuk, V V↗

Mechanical Design Progress of the In Situ Nanoprobe Instrument for APS-U

The In Situ Nanoprobe (ISN, 19-ID) beamline will be a new best-in-class long beamline to be constructed as part of the Advanced Photon Source Upgrade (APS-U) project [1, 2]. To achieve long working distance at high spatial resolution, the ISN instrument will be positioned 210 m downstream of the x-ray source, in a dedicated satellite building, currently under construction [3]. The ISN instrument will use a nano-focusing Kirkpatrick-Baez (K-B) mirror system, which will focus hard x-rays to a focal spot as small as 20 nm, with a large working distance of 61 mm. The large working distance provides space for various in situ sample cells for x-ray fluorescence tomography and ptychographic 3D imaging, allows the use of a separate, independent vacuum chambers for the optics and sample, and provides the flexibility to run experiments in vacuum or at ambient pressure. A consequence of the small spot size and large working distance are stringent requirements for high angular stability of the K-B mirrors (5 nrad V-mirror and 16 nrad H-mirror) and high relative stability be-tween focus spot and sample (4 nmRMS). Additional features include fly-scanning up to 2 kg mass, sample plus in situ cell, at 1 mm/s in vertical and/or horizontal directions over an area of 10 mm x 10 mm. Environmental capabili-ties will include heating and cooling, flow of fluids and applied fields, as required for electrochemistry and flow of gases at high temperature for catalysis. To achieve these capabilities and precise requirements we have used precision engineering fundamentals to guide the design process.

Kearney, Steven P.↗

Holistic digital gamma-ray spectroscopy methods and instrumentation for high-throughput high-resolution applications

Method of real-time adaptive digital pulse signal processing for high count rate gamma-ray spectroscopy applications includes receiving a preamplifier signal at a pulse deconvolver, the preamplifier signal including resolution deterioration resulting from pulse pile-up. The method further includes generating a deconvoluted signal, by the pulse deconvolver, from the preamplifier signal, the deconvoluted signal having less resolution deterioration as compared to the received preamplifier signal. The method furthermore includes shaping of the deconvoluted signal by a trapezoid filter, the shaping comprising adjusting a shaping parameter of the trapezoid filter for an incoming signal based on a time separation from a subsequent incoming signal.

Hawari, Ayman I.↗

Calibration of the Falcon Solid-state Energetic Electron Detector (SEED)

The Falcon Solid-state Energetic Electron Detector (FalconSEED) is an energetic charged particle sensor that has been developed and tested at the United States Air Force Academy in an effort to monitor electron flux across the energy range of 14 to 145 keV in geosynchronous orbit. This sensor has been developed to complement ongoing efforts by the Air Force Research Laboratory to advance a comprehensive space environment sensor suite, Compact Environmental Anomaly Sensor (CEASE3), for anomaly resolution. In addition, FalconSEED is intended to demonstrate the ability to operate a radiation sensor based on predominantly commercial off the shelf components in the geosynchronous environment. This paper describes the design, development, and calibration of FalconSEED. The electron energy spectrum of interest for the FalconSEED sensor is 14 to 145 keV, and is intended to supplement data acquired from the CEASE3 instrument for anomaly resolution. The calibrations at the Space Atmospheric Research Center at the United States Air Force Academy and Kirtland Air Force Base were used to first establish the conversion between histogram bin number and deposited energy in the sensor, and second have been used to determine the geometric factor as a function of energy. The FalconSEED will be integrated as a science payload on the Space Test Program Satellite-6 which also includes the first flight of the CEASE3 instrument and is scheduled to launch in 2021.

47 OTHER INSTRUMENTATION↗

Development and characterization of a laser-gated, high resolution x-ray radiography platform for high energy density experiments using toroidally bent crystals

Bent crystal x-ray imagers are a well-established diagnostic tool to study high energy density (HED) objects by acquiring two-dimensional x-ray radiographs. Often, studying these HED objects requires very high spatial resolution, which is limited by astigmatism when using spherically bent crystals. By using toroidal-shaped crystals instead, astigmatism can be reduced and the overall spatial resolution of the instrument improved. Here, the development and characterization of a laser-gated x-ray radiography platform at the National Ignition Facility using a toroidal crystal is presented. This includes measurements of the spatial and temporal profile, which is determined by the x-ray source. In conclusion, to properly validate the reduced astigmatism, a new multi-plane grid approach was implemented, which, for the first time, allows a depth of field measurement, alignment verification and x-ray source size estimate in a single shot, demonstrating the current platform’s capability to provide sub-10 μm resolution over a 0.9 mm depth of field with a temporal resolution of 110 ps.

Crystal optics↗