Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “instrumental resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

SDSS-IV MaNGA: calibration of astrophysical line-widths in the Hα region using HexPak observations

ABSTRACT We have re-observed $\rm \sim$40 low-inclination, star-forming galaxies from the MaNGA survey (σ ∼ 65 km s−1) at ∼6.5 times higher spectral resolution (σ ∼ 10 km s−1) using the HexPak integral field unit on the WIYN 3.5-m telescope. The aim of these observations is to calibrate MaNGA’s instrumental resolution and to characterize turbulence in the warm interstellar medium and ionized galactic outflows. Here we report the results for the Hα region observations as they pertain to the calibration of MaNGA’s spectral resolution. Remarkably, we find that the previously reported MaNGA line-spread-function (LSF) Gaussian width is systematically underestimated by only 1 per cent. The LSF increase modestly reduces the characteristic dispersion of H ii regions-dominated spectra sampled at 1–2 kpc spatial scales from 23 to 20 km s−1 in our sample, or a 25 per cent decrease in the random-motion kinetic energy. This commensurately lowers the dispersion zeropoint in the relation between line-width and star-formation rate surface-density in galaxies sampled on the same spatial scale. This modest zero-point shift does not appear to alter the power-law slope in the relation between line-width and star-formation rate surface-density. We also show that adopting a scheme whereby corrected line-widths are computed as the square root of the median of the difference in the squared measured line width and the squared LSF Gaussian avoids biases and allows for lower signal-to-noise data to be used reliably.

Chattopadhyay, Sabyasachi↗

Simulated cosmic microwave background maps at 0.5 deg resolution: Unresolved features

High-contrast peaks in the cosmic microwave background (CMB) anisotropy can appear as unresolved sources to observers. We fit simluated CMB maps generated with a cold dark matter model to a set of unresolved features at instrumental resolution 0.5 deg-1.5 deg to derive the integral number density per steradian n (greater than absolute value of T) of features brighter than threshold temperature absolute value of T and compare the results to recent experiments. A typical medium-scale experiment observing 0.001 sr at 0.5 deg resolution would expect to observe one feature brighter than 85 micro-K after convolution with the beam profile, with less than 5% probability to observe a source brighter than 150 micro-K. Increasing the power-law index of primordial density perturbations n from 1 to 1.5 raises these temperature limits absolute value of T by a factor of 2. The MSAM features are in agreement with standard cold dark matter models and are not necessarily evidence for processes beyond the standard model.

Kogut, A.↗

Circumnuclear ionized gas in starburst nuclei

In order to study kinematical properties of starburst nuclei (SBNs), researchers made high-resolution spectroscopy of fifteen SBNs in the H alpha region using an intensified Reticon system attached to the coude focus of the 188-cm reflector at the Okayama Astrophysical Observatory. The instrumental resolution is 21 km s(-1) Full Width Half Maximum (FWHM) at lambda sub H alpha. As for the archetypical SBN, Mrk 538 (=NGC 7714), researchers present high-resolution emission line profiles of several species of ions such as (OIII), (NII), (SII), and (OII). Main results and conclusions are summarized. It has been known that emission-line profiles of SBNs are symmetrical and narrow. However, this high-resolution spectroscopy shows that the observed emission-line profiles of the SBNs have the following asymmetrical patterns; blueward, redward, and double-peaked. It is known that such features have been observed for narrow line regions (NLRs) of active galactic nuclei (AGNs). There is no remarkable correlation between the asymmetry index and the reddening indicator such as a Balmer decrement. Thus the line asymmetry is not attributed to inhomogeneous obscuration in the emitting regions. The observed FWHMs of the H alpha emission lines cover a range from 85 km s(-1) to 318 km s(-1) and are slightly larger than those of (NII) lambda 6584A emission except for the double-peaked SBNs. The FWHMs of H alpha emission show a good correlation with sin i (i is an inclination angle of galaxy). This correlation means that the FWHMs of the SBNs suffer significantly from rotational broadening. Mrk 52 is an anomalous SBN because it has narrow emission line widths for its high inclination angle (cf. Taniguchi 1987). From the above correlation, it is estimated that the intrinsic (i.e., rotation free) FWHMs of H alpha emission are about 50 km s(-1).

Taniguchi, Yoshiaki↗

Global O VI line emission from the Cygnus Loop supernova remnant and direct kinematic measurement of the associated shock

A far-ultraviolet spectrophotometric emission-line mapping of the Cygnus Loop supernova remnant is presented. These are results from the first flight of the rocket-borne, High Resolution Emission Line Spectrometer. The spatial distribution of the emission is that of a limb-brightened shell, and similar to soft X-ray maps. The emission-line profiles, which are broader than the instrument resolution, were consistent with uniformly expanding shell models. Best-fit values give a radial expansion velocity to the emissive region of 185(+/-19) km/s and a reddening-corrected average surface brightness of 8.8(+/-3.6) x 10 exp -6 ergs/sq cm s sr in the doublet. Comparison of the observed brightness with predictions of both radiative and nonradiative shock models provides constraints for the global blast wave ram pressure as well as a "covering factor" of the intermediate velocity shock.

Rasmussen, Andrew↗

Comparative assessment of different aluminum alloys for neutron beam window applications

The choice of an aluminum alloy window along a neutron beam requires careful consideration depending on the requirements of the instrument end station. The windows should generally be thin to minimize loss of neutrons from the beam due to scattering and absorption but still thick enough to be structurally sound for safety requirements. Further, the microstructure of the material is dependent on the alloy and the preparation method and may introduce scattering artifacts or smearing of the instrument resolution that are not desirable. In this manuscript, SANS and total cross section measurements of several different aluminum alloys will be presented and compared in order to provide some useful insight to engineers working on future neutron instrument design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of gamma-ray lines from the direction of the Crab Nebula

The Crab Nebula and its associated pulsar NP0531+21 were observed during a balloon flight of the Durham MK1 high resolution spectrometer on June 6, 1981. The data indicate two significant line features of energies of 404.7 and 1049.8 keV with intensities of (7.2 + or - 2.1) x 0.001 and (12.0 + or - 0.5) x 0.01/5. After subtracting instrumental resolution, the widths of these lines were determined to be (3.5 + or - 1.4) keV and (6.3 + or - 1.6) keV at 404.7 and 1049.8 keV respectively. A third line at 78.8 keV was detected as a transient event with a peak intensity of (1.1 + or - 0.3) x 0.01 photons sq cm/s and a width 1.5 keV. It is shown that all three line features are consistent with a point source located at the Crab.

Owens, A.↗

First Very Long Baseline Interferometry Detections at 870μm

The first very long baseline interferometry (VLBI) detections at 870$\mu$m wavelength (345$\,$GHz frequency) are reported, achieving the highest diffraction-limited angular resolution yet obtained from the surface of the Earth, and the highest-frequency example of the VLBI technique to date. These include strong detections for multiple sources observed on inter-continental baselines between telescopes in Chile, Hawaii, and Spain, obtained during observations in October 2018. The longest-baseline detections approach 11$\,$G$\lambda$ corresponding to an angular resolution, or fringe spacing, of 19$\mu$as. The Allan deviation of the visibility phase at 870$\mu$m is comparable to that at 1.3$\,$mm on the relevant integration time scales between 2 and 100$\,$s. The detections confirm that the sensitivity and signal chain stability of stations in the Event Horizon Telescope (EHT) array are suitable for VLBI observations at 870$\mu$m. Operation at this short wavelength, combined with anticipated enhancements of the EHT, will lead to a unique high angular resolution instrument for black hole studies, capable of resolving the event horizons of supermassive black holes in both space and time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lunar mass spectrometer test program

The procedures used and the results are described, which were obtained in a test program to demonstrate the performance of a candidate lunar mass spectrometer. The instrument was designed to sample and measure gases believed to exist in the lunar atmosphere at the surface. The instrument consists of a cold cathode ion source, a small quadrupole mass analyzer, and an off-axis electron multiplier ion-counting detector. Instrument resolution, sensitivity, and S/N ratio were demonstrated over the mass range 0-150 amu and over a partial pressure range from ntorr to ptorr. The subject analyzer was also prepared for extended testing, in conjunction with two other candidate instruments, in a large molecular beam vacuum facility.

Torney, F. L.↗

Analysis of Supergranule Sizes and Velocities Using Solar Dynamics Observatory (SDO)/Helioseismic Magnetic Imager (HMI) and Solar and Heliospheric Observatory (SOHO)/Michelson Doppler Imager (MDI) Dopplergrams

Co-temporal Doppler images from Solar and Heliospheric Observatory (SOHO)/ Michelson Doppler Imager (MDI) and Solar Dynamics Observatory (SDO)/Helioseismic Magnetic Imager (HMI) have been analyzed to extract quantitative information about global properties of the spatial and temporal characteristics of solar supergranulation. Preliminary comparisons show that supergranules appear to be smaller and have stronger horizontal velocity flows within HMI data than was measured with MDI. There appears to be no difference in their evolutionary timescales. Supergranule sizes and velocities were analyzed over a ten-day time period at a 15-minute cadence. While the averages of the time-series retain the aforementioned differences, fluctuations of these parameters first observed in MDI data were seen in both MDI and HMI time-series, exhibiting a strong cross-correlation. This verifies that these fluctuations are not instrumental, but are solar in origin. The observed discrepancies between the averaged values from the two sets of data are a consequence of instrument resolution. The lower spatial resolution of MDI results in larger observed structures with lower velocities than is seen in HMI. While these results offer a further constraint on the physical nature of supergranules, they also provide a level of calibration between the two instruments.

Dopplergrams↗

Optimization of neutron chopper and optics for CENTAUR, the SANS/WANS diffractometer at the spallation neutron source second target station

Herein this report presents the physics design and optimization of the neutron chopper and optics systems for the CENTAUR instrument, a multifunctional small-angle and wide-angle neutron scattering diffractometer for the Spallation Neutron Source Second Target Station. This instrument will offer a wide range of capabilities, including small-angle neutron scattering with wide Q coverage (e.g., 0.001–20 Å –1 ), providing a tool to investigate structures from atomic to mesoscopic scales simultaneously. To efficiently transport desired neutrons from the compact high-brightness cold source, several innovative designs are utilized: a time-zero chopper with a straight guide system for short-wavelength neutrons, octagonal guides for higher flux, and a correlation chopper to reduce inelastic scattering. The optimization process considers factors such as useable time-integrated flux, instrument resolution, brilliance transfer, divergence, and acceptance diagram uniformity. The overall design prioritizes flexibility to accommodate diverse user requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanoscale Photoexcited Carrier Dynamics in Perovskites

The optoelectronic properties of lead halide perovskite thin films can be tuned through compositional variations and strain, but the associated nanocrystalline structure makes it difficult to untangle the link between composition, processing conditions, and ultimately material properties and degradation. Here, we study the effect of processing conditions and degradation on the local photoconductivity dynamics in [(CsPbI 3 ) 0.05 (FAPbI 3 ) 0.85 (MAPbBr 3 ) 0.15 ] and (FA 0.7 Cs 0.3 PbI 3 ) perovskite thin films using temporally and spectrally resolved microwave near-field microscopy with a temporal resolution as high as 5 ns and a spatial resolution better than 50 nm. For the latter FACs formulation, we find a clear effect of the process annealing temperature on film morphology, stability, and spatial photoconductivity distribution. After exposure of samples to ambient conditions and illumination, we find spectral evidence of halide segregation-induced degradation below the instrument resolution limit for the mixed halide formulation, while we find a clear spatially inhomogeneous increase in the carrier lifetime for the FACs formulation annealed at 180 degrees C.

14 SOLAR ENERGY↗

An instrument for rapidly measuring plasma distribution functions with high resolution

An instrument which can rapidly measure plasma particle distribution functions has been developed based upon recent innovations in electrostatic analyzer design and position sensitive particle detection. The new analyzer uses a quadrispherical geometry, but has a completely uniform 360 deg fan-shaped field of view. The polar angular distribution of entering particles is spatially imaged onto a position sensitive detector at the annular exit aperture after a deflection through 90 deg. Several methods of position sensitive detection have been successfully used in conjunction with this analyzer. The simplest is individual channel multipliers spaced around the annular exit. Microchannel plate electron multipliers permit greater position resolution to be obtained, and a detector using microchannel plates followed by a resistive anode image converter obtains angular resolution of about one degree, i.e., 360 individual angle pixels. Instruments of this type were flown on a sounding rocket in early 1982 and will be included on the Giotto comet mission and the AMPTE ion release module (IRM).

Carlson, C. W.↗

Overview of LBTI: A Multipurpose Facility for High Spatial Resolution Observations

The Large Binocular Telescope Interferometer (LBTI) is a high spatial resolution instrument developed for coherent imaging and nulling interferometry using the 14.4 m baseline of the 2x8.4 m LBT. The unique telescope design, comprising of the dual apertures on a common elevation-azimuth mount, enables a broad use of observing modes. The full system is comprised of dual adaptive optics systems, a near-infrared phasing camera, a 1-5 micrometer camera (called LMIRCam), and an 8-13 micrometer camera (called NOMIC). The key program for LBTI is the Hunt for Observable Signatures of Terrestrial planetary Systems (HOSTS), a survey using nulling interferometry to constrain the typical brightness from exozodiacal dust around nearby stars. Additional observations focus on the detection and characterization of giant planets in the thermal infrared, high spatial resolution imaging of complex scenes such as Jupiter's moon, Io, planets forming in transition disks, and the structure of active Galactic Nuclei (AGN). Several instrumental upgrades are currently underway to improve and expand the capabilities of LBTI. These include: Improving the performance and limiting magnitude of the parallel adaptive optics systems; quadrupling the field of view of LMIRcam (increasing to 20"x20"); adding an integral field spectrometry mode; and implementing a new algorithm for path length correction that accounts for dispersion due to atmospheric water vapor. We present the current architecture and performance of LBTI, as well as an overview of the upgrades.

The Large Binocular Telescope Interferometer (LBTI↗

Mass resolution optimization in a large isotopic composition experiment

A range-energy experiment was built to measure the isotopic composition of galactic cosmic rays. An enrichment of neutron rich isotopes, 22Ne and (25Mg + 26Mg) in particular, when compared to the solar composition is shown. A rich statistics measurement of these and other neutron-rich isotopes in the galactic flux yields information to the source of these particles. A computer simulation of the experiment was used to estimate the instrument resolution. The Cherenkov detector light collection efficiency, was calculated. Absorption of light in the radiator was considered to determine the optimum Cherenkov medium thickness. The experiment will determine the isotopic composition for the elements neon through argon in the energy range 300 to 800 MeV per nucleon.

Esposito, J. A.↗

Magnetic field observations on DE-A and -B

Magnetic field observations are conducted on each of the DE-A and -B satellites by a triaxial fluxgate magnetometer. In the basic mode the instrumental resolution is + or - 1.5 nT; in addition, the DE-A magnetometer has two modes of higher resolution: + or - 0.25 nT and + or - 20 pT. The sampling rate is 16 vector samples per second in all modes. The experiment objectives include observations of field-aligned currents, magnetospheric equatorial currents, and ULF waves. These observations, taking full advantage of the specifically selected orbits of the two spacecraft and of the unique combination of instruments, are performed to achieve a better understanding of the electrodynamic coupling within the atmosphere-ionosphere-magnetosphere system and of wave-particle interactions which contribute to the coupling processes.

Farthing, W. H.↗

Interferometric Characterization of the Earth's Atmosphere from Lagrange Point 2

Part of the NASA plans for future Earth Science missions calls for observations using novel vantage points that can produce science products otherwise unobtainable. Observations of the Earth from the Lagrange-2 point, L-2, (1.5 million km behind the Earth on the Earth-Sun line) affords a unique vantage point for atmospheric science. Spectral observation of the Earth's atmosphere using solar occultation techniques in the near infrared (1 to 4 microns) provides one of the most accurate methods of passively sensing attitude profiles of the major species (CO2, O3, O2, CH4, H2O N2O). While traditional polar orbiting occultation measurements can obtain about 14 measurements per day (2 per orbit), solar occultation observations from the Lagrange-2 point will yield hourly profile measurements at all latitudes. The expected spatial resolution is 2 km in altitude, 0.5 degrees in latitude, and 2 degrees in longitude. The result from 24 hours of observations will be a three-dimensional map of atmospheric composition. To accomplish this task from L-2 requires the development of a large moderate spectral resolution instrument whose entrance aperture is about 10 meters. Use of a standard telescope design with a 10-meter circular mirror or a 10-meter strip mirror would be prohibitively expensive and excessively massive. Instead, we are proposing the development of a 10-meter linear interferometer coupled to a Fourier transform imaging spectrometer. The result will be a highly efficient design with sufficient sensitivity, while having both spatial and spectral resolution to produce the desired results. Preliminary calculations show that seven species (CO2, O3, O2, CH4, H2O N2O) have clearly separated spectral features in the I to 4 microns range with sufficient absorption to produce profile information from near the Earth's surface to the middle stratosphere. For CO2 the estimated sensitivity to change is 0.33% or 1 part in 330. This should be sufficient to detect changes that are significant for the carbon cycle studies. Initial instrument design studies are underway to determine the optimum optical design for the interferometer-spectrometer as well as the necessary highly stable mechanical designs. Separate design studies are being conducted for the spacecraft. shuttle launch facility, low-light solar power design, thermal control, and unique navigation requirements to reach and maintain the tight halo orbit about L-2.

Herman, Jay R.↗

Start-to-end self-consistent simulation of the UEM beamline

Addressing the preliminary design review report of the ultrafast electron microscope (UEM), start-to-end self-consistent simulations were carried out to explore fundamental aspects affecting the resolution (space-charge effects, energy spread, shot-to-shot energy jitter, contrast formation, etc.). The electron beam energy spread in the single-shot mode and the effective energy spread in the accumulation mode, equivalent to the convolution of the single-shot energy spread and shot-to-shot energy jitter, have been identified as the ultimate limits of the instrument resolution. A full self-consistent simulation from the photocathode to the detector is being performed using the GPT code to find out what resolution can be achieved. Preliminary results of the start-to-end simulations are reported in this note and the plan of further simulations is presented.

43 PARTICLE ACCELERATORS↗

Nondestructive ultrasonic measurement of bolt preload using the pulsed-phase locked-loop interferometer

Achieving accurate preload in threaded fasteners is an important and often critical problem which is encountered in nearly all sectors of government and industry. Conventional tensioning methods which rely on torque carry with them the disadvantage of requiring constant friction in the fastener in order to accurately correlate torque to preload. Since most of the applied torque typically overcomes friction rather than tensioning the fastener, small variations in friction can cause large variations in preload. An instrument called a pulsed phase locked loop interferometer, which was recently developed at NASA Langley, has found widespread use for measurement of stress as well as material properties. When used to measure bolt preload, this system detects changes in the fastener length and sound velocity which are independent of friction. The system is therefore capable of accurately establishing the correct change in bolt tension. This high resolution instrument has been used for precision measurement of preload in critical fasteners for numerous applications such as the space shuttle landing gear and helicopter main rotors.

Allison, S. G.↗