Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “installs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Installation and imaging of thousands of minirhizotrons to phenotype root systems of field-grown plants

Roots are vital to plant performance because they acquire resources from the soil and provide anchorage. However, it remains difficult to assess root system size and distribution because roots are inaccessible in the soil. Existing methods to phenotype entire root systems range from slow, often destructive, methods applied to relatively small numbers of plants in the field to rapid methods that can be applied to large numbers of plants in controlled environment conditions. Much has been learned recently by extensive sampling of the root crown portion of field-grown plants. But, information on large-scale genetic and environmental variation in the size and distribution of root systems in the field remains a key knowledge gap. Minirhizotrons are the only established, non-destructive technology that can address this need in a standard field trial. Prior experiments have used only modest numbers of minirhizotrons, which has limited testing to small numbers of genotypes or environmental conditions. This study addressed the need for methods to install and collect images from thousands of minirhizotrons and thereby help break the phenotyping bottleneck in the field. Over three growing seasons, methods were developed and refined to install and collect images from up to 3038 minirhizotrons per experiment. Modifications were made to four tractors and hydraulic soil corers mounted to them. High quality installation was achieved at an average rate of up to 84.4 minirhizotron tubes per tractor per day. A set of four commercially available minirhizotron camera systems were each transported by wheelbarrow to allow collection of images of mature maize root systems at an average rate of up to 65.3 tubes per day per camera. This resulted in over 300,000 images being collected in as little as 11 days for a single experiment. The scale of minirhizotron installation was increased by two orders of magnitude by simultaneously using four tractor-mounted, hydraulic soil corers with modifications to ensure high quality, rapid operation. Image collection can be achieved at the corresponding scale using commercially available minirhizotron camera systems. Along with recent advances in image analysis, these advances will allow use of minirhizotrons at unprecedented scale to address key knowledge gaps regarding genetic and environmental effects on root system size and distribution in the field.

54 ENVIRONMENTAL SCIENCES↗

Installation of Lysimeters Near Engineered Trench 3

Three new lysimeter stations were installed on the north rim of Engineered Trench 3 (Figure ES-1)at the E-Area Low Level Waste Facility (ELLWF). These stations were designated as ET3-VL-3, ET3-VL-4, and ET3-VL-5. The stations were installed in a line with the two existing stations (ET3-VL-1 and ET3-VL-2) and spaced approximately 100 ft apart. Two lysimeters were installed at each station at the depths shown in Table ES-1. Lysimeter placement was based on borehole lithology and was comparable to the existing lysimeter stations. The deepest lysimeter at each of the three new lysimeter stations was designated as the action-level lysimeter.Following installation, the lysimeters were purged and placed under vacuum for sampling. Sampling occurred in December 2020 with each lysimeter producing 1000 ml of water for tritium analysis. All lysimeters were below the administrative limit for ET3 (43.7 pCi/ml) with all but ET3-VL-5 (222) at background levels. ET3-VL-5 (222) had a tritium concentration of 27.5 pCi/ml.With the addition of the new lysimeters at ET3, the vadose zone monitoring system is now comprised of 309 active lysimeters at 102 lysimeter stations. There are 93 action-level lysimeters at 102 stations

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimizing Residential HVAC Systems: Evaluating How the Usage of Smart Diagnostic Tools for Quality Installation and Commissioning Impacts System Performance and HVAC Contractor Businesses

The adoption of digital quality installation and fault detection tools has the potential to transform the $14 billon residential heating, ventilating, and air conditioning (HVAC) service and installation industry. Increased market penetration can be accelerated by providing an increased understanding of the energy and economic value proposition of the usage of these tools. In tandem with energy and HVAC system performance impact research and analysis, the Southface Team investigated the economic business implications for HVAC service and installation contractors adopting the use of measureQuick (mQ), a smart diagnostic app that aids in quality installation and fault detection and works agnostically with Bluetooth-enabled HVAC technician tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of shading following installation of agrivoltaic systems on eco-physiological and biochemical attributes of “Howes” cranberry in Massachusetts

Agrivoltaic (AV) systems, which integrate solar energy generation with crop production on the same piece of land, offer a sustainable solution for optimizing land-use efficiency. However, the impact of shading induced by solar panels on crop growth, physiology, and metabolic activities of cranberry is not known. Understanding these interactions is essential for assessing the feasibility of AV systems in cranberry production. In this study we evaluated eco-physiological and biochemical crop responses on a commercial ‘Howes’ cranberry bog grown under an agrivoltaics system using different row spacings in the year immediately following installation. Following installation of fixed tilt solar panels at a height of 3.0 m above the plant canopy, four shading treatments were evaluated: an uncovered control area and row spacings of 9.0 m, 7.0 m, and 5.0 m, corresponding to 30%, 35%, and 37% shading respectively. The shading effect was also evaluated at three different fruit developmental stages (green, blush, and full-red stage). Using microclimate sensors installed in the treatment areas, key eco-physiological and biochemical parameters, including leaf gas exchange, chlorophyll, anthocyanin, and antioxidant content, electrolyte leakage, proline and trehalose accumulation, were assessed. While moderate shading (30% and 35%) alleviated environmental stress, as reflected by improved leaf water status and reduced electrolyte leakage, these same treatments suppressed key physiological and metabolic functions, including photosynthetic activity, carbon reserve accumulation, and the biosynthesis of stress-related osmolytes and antioxidant compounds. Under higher shading (37%), these reductions were even more pronounced, indicating a potential threshold beyond which the benefits of shading are outweighed by declines in assimilate production and secondary metabolism. These findings highlight a trade-off between the stress-mitigating benefits of shading and the alterations in key physiological and metabolic processes under agrivoltaic systems. Minimizing these trade-offs by optimizing row spacing in agrivoltaics systems is critical to maintain cranberry physiological status. Since commercial cranberry is grown as a continuous plant canopy (no interrow spaces for equipment travel), damage caused by the installation process likely impacted crop response evaluated in the first year; multi-year studies are needed to fully understand the dynamics of a dual-use system. Notably, this work provides the first direct measurements of proline, trehalose content, and electrolyte leakage in cranberry grown under AV conditions, offering new insight into their physiological adjustments to shading.

14 SOLAR ENERGY↗

Energy Master Planning for Resilient Public Communities—Best Practices from U.S. Military Installations

Until recently, most planners at military installations addressed energy systems for new facilities on an individual facility basis without consideration of community-wide goals relevant to energy sources, renewables, storage, or future energy generation needs. Building retrofits of public buildings typically do not address energy needs beyond the minimum code requirements making it difficult, if not impossible, to achieve community-level targets on a building-by-building basis. Planning on the basis of cost and general reliability may also fail to deliver community-level resilience. For example, many building code requirements focus on hardening to specific threats, but in a multi-building community, only a few of these buildings may be mission-critical. Over the past two decades, the frequency and duration of regional power outages and water utility disruptions from weather, man-made events, and aging infrastructure have increased. Major disruptions of electric and thermal energy have degraded critical mission capabilities and caused significant economic impacts. In 2016, the U.S. Department of Defense issued guidance that each Service (Army, Navy, Air Force, Marines) complete comprehensive energy plans for the installations that consumed 75% of total building energy. Guidance was updated in 2017 to include metrics for energy resilience, and in some cases, water. This paper describes how community level quantitative and qualitative resilience analysis and metrics have been incorporated into community energy and water planning best practices for military installations in three geographically diverse locations. It is based on research performed under the International Energy Agency’s “Energy in Buildings and Communities Program Annex 73,” focusing on development of guidelines and tools that support the planning of Net Zero Energy Resilient Public Communities as well as research performed under the Department of Defense Environmental Security Technology Certification Program project EW18-D1- 5281, “Technologies Integration to Achieve Resilient, Low- Energy Military Installations.” The first case study reviews progress made on an energy and water planning study conducted at Fort Bliss, Texas. The second and third describes planning conducted at Fort Bragg, North Carolina and the Joint Region Marianas, Guam, respectively, under the updated guidance from 2017 regarding energy and water resilience. Analysis methods, key metrics, and key infrastructure and operational constraints are described, as well as technical, economic and business concepts used during the planning process.

Urban, Angela B.↗

Assessing the Impacts of Extreme Weather Events on Photovoltaic Installations Using Remote Sensing Imagery

In this study, we analyze poststorm satellite imagery to assess solar photovoltaic (PV) damage for over 11,300 systems following a catastrophic hailstorm in Austin, TX, in September 2023, which produced softball‐sized hail and for over 1500 systems across Puerto Rico and the US Virgin Islands after Hurricanes Irma and Maria in September 2017. Findings show that approximately 5.5% of identified PV sites were damaged in the hailstorm and approximately 17% of PV installations were damaged after the hurricanes. A weak correlation between hurricane wind gust speed and percent site damage was determined, with installation practices playing a heavy role in site resilience. Additionally, we show that newer module vintages are more susceptible to hail damage than older modules, possibly due to a convergence of larger size modules, decreased frame dimensions, and decreased front glass thickness but more research is needed. For hail sizes of 60 mm or greater, consistent hail damage is sustained by PV installations, regardless of system configuration.

14 SOLAR ENERGY↗

Installation protocol for charge transfer dissociation mass spectrometry on ion trapping mass spectrometers

Abstract Rationale Charge transfer dissociation (CTD) is a novel fragmentation technique that demonstrates enhanced structural characterization for a wide variety of molecules compared to standard fragmentation techniques like collision‐induced dissociation (CID). Alternative fragmentation techniques, such as electron transfer dissociation, electron capture dissociation, and ultraviolet photodissociation, also overcome many of the shortfalls of CID, but none of them are a silver bullet that can adequately characterize a wide variety of structures and charge states of target compounds. Given the diversity of structural classes and their occasional obstinance towards certain activation techniques, alternative fragmentation techniques are required that rely on novel or alternative modes of activation. Methods Herein, we present a step‐by‐step protocol for the installation of CTD on a quadrupole ion trap mass spectrometer and best practices for optimizing the signal‐to‐noise ratio and acquisition times for CTD mass spectra. Results In addition to two CTD installations in the Jackson laboratory, CTD has also been installed, and is currently in operation, on two 3D ion trap mass spectrometers in France: one in the laboratory of Dr. David Ropartz and Dr. Hélène Rogneaux at INRAE in Nantes, and the other in the laboratory of Dr. Jean‐Yves Salpin at Université d'Évry Val‐d'Essonne, part of the Paris‐Saclay University system. Conclusions Here, we provide a visual protocol to help others accomplish the instrument modification.

47 OTHER INSTRUMENTATION↗

Uplifting winds: The surprisingly positive community-wide impact of wind energy installations on property values

A primary concern of stakeholders when considering a new wind project is the potential negative effects wind turbines may have on home values. Yet, what has been surprisingly overlooked in the literature and general discourse around wind energy is that the well-researched positive economic development and fiscal and amenity benefits of wind energy (e.g., increased tax base, tax revenue, better public services and employment gains) might positively affect jurisdiction-wide housing values. With a focus on school districts in the United States, we compare home values in school districts with wind energy installations, before and after a wind energy installation becomes operational, to home values in other school districts located in the same county but without a wind energy installation to provide some of the first causal evidence on the relationship between wind energy projects and district-wide property values. We find that wind projects lead to economically meaningful increases in district-wide housing values of approximately 3 %, when those values are compared to similar homes located in school districts in same-county without wind energy. The effect is strongly correlated with wind project size. The mechanisms, our research suggests, are likely related to relatively large increases in school district per-pupil revenues and expenditures, which are also correlated with wind project size. We suggest other possible mechanisms for the increased values as well.

Attitudes↗

First STAX detector installation at the National Institute for Radioelements (IRE)

The Source Term Analysis of Xenon (STAX) project has been installing stack detectors at medical isotope production facilities to measure radioxenon emissions to investigate the effect of radioxenon releases on nuclear explosion monitoring. This paper outlines the installation of the first STAX detection system at the National Institute for Radioelements (IRE) in Fleurus, Belgium which has been operating for over three years and transferring collected data to the STAX repository. Information about the equipment installed, the data flow established, and calculations for determination of radioxenon releases from the facility are presented. Further. data quality was investigated to confirm values reported by STAX automated data processing and in a comparison of collected STAX data with data collected by IRE for regulatory reporting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrogen Mitigation Process Installation at Nevada Solar One

The National Renewable Energy Laboratory (NREL) and Acciona Solar Power (ASP) have developed and are implementing a process that addresses the issue of hydrogen buildup in parabolic trough power plants. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). During previous work, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. We demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure—from 1.33 mbar down to 0.003 mbar. More recently, we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. We demonstrated the performance of a laboratory-scale version of this module. Testing showed that the module performed as expected: the accuracy of the sensing function was ±7%, and the hydrogen extraction rate for the separating mode was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. Most recently, NREL and ASP planned, specified, and designed a mitigation process that is based on the integrated module. We are currently completing installation of this process at ASP's Nevada Solar One power plant in Boulder City, Nevada, USA. The mitigation process is being installed at ground level below the HTF expansion tanks, where it draws headspace gas from the tanks, removes hydrogen, and returns the treated gas back to the tanks. In this paper, we report progress on the installation and describe some of the many design details and challenges that we addressed during the past year. We will generate initial performance data from the Nevada Solar One mitigation process in early 2020.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Design, characterization and installation of the NEXT-100 cathode and electroluminescence regions

NEXT-100 is currently being constructed at the Laboratorio Subterráneo de Canfranc in the Spanish Pyrenees and will search for neutrinoless double beta decay using a high-pressure gaseous time projection chamber (TPC) with 100 kg of xenon. Charge amplification is carried out via electroluminescence (EL) which is the process of accelerating electrons in a high electric field region causing secondary scintillation of the medium proportional to the initial charge. The NEXT-100 EL and cathode regions are made from tensioned hexagonal meshes of 1 m diameter. This paper describes the design, characterization, and installation of these parts for NEXT-100. Simulations of the electric field are performed to model the drift and amplification of ionization electrons produced in the detector under various EL region alignments and rotations. Measurements of the electrostatic breakdown voltage in air characterize performance under high voltage conditions and identify breakdown points. Furthermore, the electrostatic deflection of the mesh is quantified and fit to a first-principles mechanical model. Measurements were performed with both a standalone test EL region and with the NEXT-100 EL region before its installation in the detector. Finally, we describe the parts as installed in NEXT-100, following their deployment in Summer 2023.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Power Generation and Oxygen Transfer Analyses for Micro Hydro-Turbine Installed in Wastewater Treatment Aeration Tank

This study targets one of the major energy consumers in the U.S. It suggests a new mechanical system that can recover a portion of the energy in Wastewater Treatment Plants (WWTPs). The proposed system entails a hydro-turbine installed above the air diffuser in the aeration tank to extract the water-bubble current’s kinetic energy and converts it to electricity. Observing the optimum location of the turbine required multiple experiments where turbine height varies between 35% and 95% (water height percentages above the diffuser), while varying the airflow between 1.42 L/s (3 CFM) and 2.12 L/s (4.5 CFM) with a 0.24 L/s (0.5 CFM) increment. Additionally, three water heights of 38.1 cm (15*), 53.4 cm (21*), and 68.6 cm (27*) were considered to study the influence of the water height. It was noticed that the presence of the system has an adverse effect on the standard oxygen transfer efficiency (SOTE). Therefore, a small dual-blade propeller was installed right above the diffuser to directly mix the water in the bottom of the tank with the incoming air to enhance the SOTE. The results showed that the maximum reclaimed power was obtained where the hydro-turbine is installed at 65–80% above the diffuser. A reduction of up to 7.32% in SOTE was observed when the setup was placed inside the tank compared to the tank alone. The addition of the dual-blade propeller showed an increase in SOTE of 7.27% with a power loss of 6.21%, ensuring the aeration process was at its standards.

Energy & Fuels↗

Emergency Diesel Generator Reliability and Installation Energy Security

The U.S. Department of Defense’s (DoD’s) fixed installations - or military bases - are a critical element of national security. Military bases support the maintenance and deployment of weapons systems, training and mobilization of combat forces, and provide direct support to combat operations. Fixed installations do not operate without energy and they rely largely on electricity to support critical missions and functions. Installations are dependent on a commercial grid that is vulnerable to disruption due to severe weather, physical attacks, and cyberattacks. This report looks at the impact on the highest priority critical loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

VERA Installation Guide

This guide describes the structure and setup of the standard VERA development environment (VERA Dev Env) and standard VERA Third Party Libraries (TPLs) that need to be in place before installing many of the VERA simulation components. It describes everything from the initial setup on a new machine to the final build, testing, and installation of VERA components. The goal of this document is to describe how to create the directories and contents outlined in 'Standard VERA Dev Env Directory Structure' and then obtain the remaining VERA source and build, test, and install any of the necessary VERA components on a given system. This document describes the process both for a development version of VERA and for a released tarball of the VERA sources.

97 MATHEMATICS AND COMPUTING↗

Options For Large-Scale Installation of Individual Heat Substations Based on International Best Practices

The purpose of this report is to provide recommendations for actions Ukraine could take to implement large-scale installation of IHSs as part of comprehensive district heating reform. The report discusses the importance of IHS in the district heating sector, then presents several case studies of approaches that European countries have taken to facilitate large-scale IHS installation in multi-apartment buildings. These case studies focus on the ownership and financing of IHS, as there are different models for how this can be done (the DH company can make the investments and recover the costs through the tariff, or building residents can make the investments themselves). They also include details on the approval process and technical specifications, as these can add additional barriers and time to the installation process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Installing MCNP6.2 on Microsoft Windows

This video shows how to install the MCNP code, version 6.2, on a Microsoft Windows 10 computer. After installation, the Xming software is installed, a quick calculation is performed, and geometry is plotted. At this point, this setup is ready for use in an MCNP classroom setting and/or for performing calculations of the viewer’s own creation.

97 MATHEMATICS AND COMPUTING↗

FAST-1.0.1 User Installation and Verification Guide

The purpose of this document is to provide the user information about the installation of FAST-1.0.1 on their computers or servers. General information about the code and supported operating systems is described in Section 1.0.1. Self-service oriented FAST-1.0.1 software licensing steps are described in Section 2.0. An installation verification test suite is provided with FAST-1.0.1 and described in Section 3.0. A convenience script for converting FRAPCON to FAST inputs is discussed in Section 4.0. FAST-1.0.1 was developed and released under a software quality assurance program based upon NQA-1-2017. FAST-1.0.1 is the latest baseline code and the result of a bug fixes to FAST-1.0 with other software and methodology developments. The installation verification test suite contains both steady state and transient Anticipated Operation Occurrences (AOOs). Capability to model accident conditions, such as Reactivity Initiated Accidents (RIAs) and Loss Of Coolant Accidents (LOCAs), are targeted for a later release of FAST. FRAPTRAN-2.0 will continue to be used for accident conditions until the release of FAST with accident condition modeling capabilities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FAST-1.2 User Installation and Verification Guide: Developed Under NQA-1-2017

The purpose of this document is to provide the user information about the installation of Fuel Analysis for Steady state and Transient (FAST)-1.2 on their computers or servers. General information about the code and supported operating systems is described in Section 1.0. Self-service oriented FAST-1.2 software licensing steps are described in Section 2.0. An installation verification test suite is provided with FAST-1.2 and described in Section 3.0. A convenience script for converting Fuel Rod Analysis Program – Constant (FRAPCON) to FAST inputs is discussed in Section 4.0. FAST-1.2 was developed and released under a software quality assurance program based upon NQA-1-2017 at Pacific Northwest National Laboratory (PNNL). FAST-1.2 is the latest baseline code. The installation verification test suite contains both steady state and transient Anticipated Operation Occurrences (AOOs), accident conditions, such as Reactivity Initiated Accidents (RIAs) and Loss of Coolant Accidents (LOCAs).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗