Engineering PapersSearch

SEARCH · Engineering Papers

Results for “information technology load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Hyperfine spectroscopy and laser cooling of the fermionic isotopes 47 Ti and 49 Ti

Here, we report on magneto-optical trapping of the two fermionic isotopes of atomic titanium, 47 Ti and 49 Ti . Unlike the even mass-number isotopes, which were recently laser cooled, 47 Ti and 49 Ti have nonzero nuclear spins and, consequently, their atomic levels are split by hyperfine structure. Combining and comparing theoretical calculations and atomic beam-spectroscopy measurements, we determine the hyperfine structures and isotope shifts of the 3⁢𝑑 2 ⁢4⁢𝑠 2 𝑎 3 ⁢𝐹 4 → 3⁢𝑑 2 ⁢( 3 𝑃)⁢4⁢𝑠⁢4⁢𝑝⁢( 3 𝑃 𝑜 ) 𝑦 5 ⁢𝐷$^o_4$ optical-pumping transition at optical wavelength 391 nm and the 3⁢𝑑 3 ⁢(4𝐹)⁢4⁢𝑠 𝑎 5 ⁢𝐹 5 → 3⁢𝑑 3 ⁢( 4 𝐹)⁢4⁢𝑝 𝑦 5 ⁢𝐺$^𝑜_6$ laser-cooling transition at wavelength 498 nm. With this information, we produce magneto-optical traps of both 47 Ti and 49 Ti by applying two additional tones of light to repump atoms to the maximum-spin states on the laser-cooling transition. Directly loading from the atomic flux of a titanium sublimation pump, we produce 47 Ti and 49 Ti traps with 731(190) and 1142(240) atoms, and with lifetimes of 330⁢(15) and 310⁢(8)⁢ ms, respectively.

atomic spectra

Small Nuclear Reactors for Maritime Ports

Maritime ports are entering a period of sharply rising electricity demand as operations are electrified, shore power adoption grows, and energy-intensive industries expand near ports. This report evaluates the feasibility of small nuclear reactors at U.S. ports, which could offer stable baseload power and reduced dependence on regional grids. The report describes the current state of advanced reactor technologies and other factors important for future deployment such as safety and operations, siting requirements, regulatory environments and policy, and other co-benefit considerations. A structured evaluation across a diverse group of U.S. ports highlights the wide variation in feasibility. Fifteen ports were analyzed through port interviews and data collection to assess the port-specific conditions that most impact advanced reactor deployment. The analysis found that the most feasible ports for deployment have favorable geotechnical stability, supportive regulatory environments, and substantial energy loads in a grid-constrained environment. Additionally, an initial reactor size matching was done for the ports based on their reported energy consumption across different modes of operation. However, further analysis and detailed data will be required in the future to determine the optimal reactor-port matching. The economic viability to adopt this technology will be dictated by competitive cost of nuclear-generated electricity compared to other alternatives. Overall, small nuclear reactors present a promising but highly site-dependent pathway for ports seeking resilient, high-capacity energy solutions that support future energy demands. This report identifies key areas for future research and highlights ports that warrant further evaluation to assess the viability of small nuclear reactor implementation. By establishing these priorities, the analysis provides support for the development of informed strategies for potential advanced nuclear technology deployment. The inclusion of ports in this report does not imply their endorsement of nuclear energy generation, and the authors are grateful for the information, expertise, and perspectives they contributed.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Estimation of General Area Dose Rates During Closure Weld Operations on the DOE Standard Canister Pacific Basin Nuclear Conference 2024

The Department of Energy (DOE) Spent Nuclear Fuel (SNF) Road Ready Demonstration Project is an effort to package DOE-managed SNF for road-ready dry storage. A key operation in this demonstration is performing the closure weld on the DOE Standard Canister after it has been loaded with the SNF. Planning the closure weld operations is ongoing and must consider what parts of the operations (if any) can be done manually and what parts must be done remotely. A key parameter to inform the evolving planning of these operations is the dose rate in the vicinity of the canister and the dose hazard posed to the closure weld operators and collocated workers. This study developed a Monte Carlo N-Particle (MCNP) model of the closure weld operation, which was used to estimate general area dose rates as well as dose rates to the welding location, weld operators, and collocated workers. These estimates provide some insight into the potential radiation exposure hazard for workers during the operations and are a factor to be considered in the ongoing development of designs, technology, processes, and administrative controls for packaging DOE-managed SNF for road-ready dry storage.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Direct Geologic Constraints on the Timing of Late Holocene Ice Thickening in the Amundsen Sea Embayment, Antarctica

Abstract Constraining past West Antarctic Ice Sheet (WAIS) change helps validate numerical models simulating future ice sheet dynamics. Following rapid deglaciation during the mid‐Holocene, ice near Thwaites Glacier was ∼35 m thinner than present; however, the timing of ice regrowth to its present configuration remains unknown. To fill this knowledge gap, we present cosmogenic nuclide exposure ages of cobbles from the surface of a moraine situated between Thwaites and Pope glaciers. We infer that the moraine formed and stabilized in the Late Holocene (∼1.4 ka) when a small glacier thickened. We also present a novel reconstruction of WAIS volume constrained by sea‐level data, which demonstrates that moraine formation coincided with a large‐scale WAIS readvance. Our new geologic constraints will help inform models of the solid Earth response to surface mass loading, improving our understanding of ice sheet dynamics in a vulnerable part of WAIS.

Nichols, Keir A. [Imperial College London London U

Assessing Geospatial and Seasonal Influences on Energy and Cost-Efficiency of Drayage Trucks

The electrification of heavy-duty vehicles is a critical pathway toward improved energy efficiency in the freight sector. The current battery electric truck technology poses several challenges to commercial vehicle operations, such as limited driving range, sensitivity to climate conditions, and long recharging times. Estimating the energy consumption of heavy-duty electric trucks is crucial to assessing the feasibility of fleet electrification and its impact on the electric grid. This article focuses on developing a model-based simulation approach to predict and analyze the energy consumption of electric trucks by considering the impact of weather and geographical conditions on vehicle road load and auxiliary components power consumption, as well as the impact these factors have on driving range. Specifically, drayage trucks employed in logistics around maritime ports are used as a case study, with consideration of seasonal climate variations and geographical characteristics at different locations. The article includes results for three major container ports within the United States, providing region-specific insights into the energy requirements and driving range of the electric drayage trucks in these regions, which will inform decision-makers in integrating electric trucks into the existing drayage operations and plan investments for electric grid development.

Sujan, Vivek [ORNL] (ORCID:0000000269882342)

Fast, Controllable, and Modular Solid-State Circuit Breaker Design for Battery Management Systems

Electric power grid is experiencing a growing number of distributed and inertia-free generation resources. To facilitate the growing generation and load demands, and ensure stable operation, energy storage systems, especially behind-themeter-storage (BTMS), have emerged as a potential candidate. BTMS plays a vital role in the grid storage sector and supports high power charging for EVs. However, the potential of thermal runaway and associated safety concerns in the batteries can hamper their widespread adoption. In this work, we provide a solution for a fast and controllable discharge of a cell that was identified as a stressful/faulty, in the battery pack, and fast circuit breaking leveraging the Solid-State Circuit Breaker (SSCB) technology which provides active control over the cell connection as opposed to conventional passive solutions. Testing on the simulation platform successfully validated the concept, demonstrating its efficacy. Controlled discharge testing with 20Ah LiFePO4 Lithium Iron Phosphate (LFP) cells from 1C-10C current rate on the hardware prototype corroborated simulation results, demonstrating design feasibility and providing essential data for its performance and thermal characteristics, while also revealing limitations that inform areas for further optimization.

33 ADVANCED PROPULSION SYSTEMS

Probabilistic Deliverability Assessment of Distributed Energy Resources via Scenario-Based AC Optimal Power Flow

As electric grids decarbonize and distributed energy resources (DERs) become increasingly prevalent, interconnection assessments must evolve to reflect operational variability and control flexibility. This paper highlights key modeling limitations observed in practice and reviews approaches for modeling uncertainty. It then introduces a Probabilistic Deliverability Assessment (PDA) framework designed to complement and extend existing procedures. The framework integrates scenario-based AC optimal power flow (AC OPF), corrective dispatch, and optional multi-temporal constraints. Together, these form a structured methodology for quantifying DER utilization, deliverability, and reliability under uncertainty in load, generation, and topology. Outputs include interpretable metrics with confidence intervals that inform siting decisions and evaluate compliance with reliability thresholds across sampled operating conditions. A case study on Puerto Rico’s publicly available bulk power system model demonstrates the framework’s application using minimal input data, consistent with current interconnection practice. Across staged fossil generation retirements, the PDA identifies high-value DER sites and regions requiring additional reactive power support. Results are presented through mean dispatch signals, reliability metrics, and geospatial visualizations, demonstrating how the framework provides transparent, data-driven siting recommendations. The framework’s modular design supports incremental adoption within existing workflows, encouraging broader use of AC OPF in interconnection and planning contexts.

14 SOLAR ENERGY

ARPA-E Grid Optimization (GO) Competition Challenge 2

The ARPA-E Grid Optimization (GO) Competition Challenge 2, from 2020 to 2021, expanded upon the problem posed in Challenge 1 by adding adjustable transformer tap ratios, phase shifting transformers, switchable shunts, price-responsive demand, ramp rate constrained generators and loads, and fast-start unit commitment. Furthermore, Challenge 2 was a maximization problem while Challenge 1 was a minimization problem. Specifically, the economic surplus, defined as the benefit of serving load minus the cost of generation, is being maximized. It was expected that the objective value of a given solution should be positive, representing economic gain, but negative objectives from poor solutions were possible. The two code submission feature of Challenge 1 was maintained. Additionally, Divisions 3 and 4 within the competition permitted on/off switching of transmission lines (Divisions 1 and 2 did not). After the initial release of the Problem Formulation on 7/20/2020, ARPA-E Director Lane Genatowski announced Challenge 2 on 9/12/2020. The final May 31, 2021, version of the Problem Formulation was 97 pages long with 299 equations. The Challenge proceeded with 2 non-prize Events and 2 prize Events. Teams receiving Challenge 1 FOA awards and prize money were required to use the prize money to fund their Challenge 2 efforts (Georgia Institute of Technology, Global Optimal Technology, Inc., Lawrence Livermore National Laboratory, Lehigh University, Northwestern University, Artelys, Columbia, Pearl Street Technologies, Pennsylvania State University, and University of Colorado Boulder). For more information on the competition and challenge 2 see the "GO Competition Challenge 2 Information" resource below. Challenge 1 and Challenge 3 information can be found in the resources linked below.

ACOPF

OC7 Phase I Definition Document

The Offshore Code Comparison Collaboration 7 (OC7) project is organized under the International Energy Agency Wind Technology Collaboration Programme Task 56 with an objective to evaluate and enhance the predictive accuracy of engineering-level modeling tools used in the design of offshore wind energy systems. Phase I of OC7 is focused on improving the models and modeling practices of hydrodynamic viscous loads on floating offshore wind turbine platforms. In alignment with this goal, Work Package 1.1 of OC7 Phase I is formulated to investigate the modeling of hydrodynamic viscous loads on several different geometric components commonly encountered with floating offshore wind platform designs, including cylindrical columns, heave plates, and rectangular pontoons. Work Package 1.1 also explores the dependence of hydrodynamic coefficients on the sea state to drive toward practical guidance on how these coefficients can be selected or adjusted for different conditions. This report outlines the motivation and objectives behind each subphase of OC7 Phase I, along with the necessary technical specifications and load case definitions to guide the project participants. It also serves as an important part of the project documentation for future modelers who would like to reproduce this work or make use of the data and information generated from the OC7 project.

17 WIND ENERGY

Developing Smart Building Technology Modules to Enhance Workforce Preparedness: A Case for AI-Driven Academic and Professional Education

Smart building technologies are resources that improve building energy efficiency and resilience, reduce carbon emissions, and provide load flexibility to the grid. However, in both academic curricula and building professionals’ continuing education, there is a lack of systematic instruction on methods to integrate multiple energy systems including distributed energy resources (DER), smart building technologies, AI (Artificial Intelligence) tools and key concepts, components, and controls, including “Internet of Things” (IoT) devices. In today’s dynamic workforce, this major gap in smart building technology education prevents stakeholders from being able to attract talent with an understanding and preparation to adopt smart building technologies in building design and operations. A federally funded project included a partnership between Slipstream and Texas A&M University (TAMU) to develop a semester-long smart building curriculum for engineering college students with the ability to adapt the contents for workforce development of professionals in building services. The final product consists of 16 training videos adapted for building professionals and the public. The educational content and training materials cover the benefits of building energy systems, the latest sensor technologies and IoT devices, all with a focus on smart building technologies. The key drivers are on topics related to smart building controls (i.e., energy management information systems), smart building control platforms, cybersecurity, grid-interactive-efficient buildings (GEBs), smart building control methods, and occupant-centric control. Although not explicitly included the technologies nod to the need for AI driven technologies to prepare engineers and industry professionals to be future ready. This paper describes the project approach, provides outlines of the training materials, and identifies lessons learned in creating the content for this course. The authors suggest ways to scale the instruction of smart building concepts to empower the workforce to accelerate the adoption of smart building technologies and AI-based teaching and learning in higher education and building sector.

99 GENERAL AND MISCELLANEOUS

Mechanical Solutions Scan Report

Power lines, poles, and towers are the backbone of the United States (U.S.) electric-power grid. These transmission and distribution networks route electricity from generator to loads. The characteristics of these routes are rapidly changing -- trending towards decentralized renewable generation, electric heating, vehicle charging, and large data-center loads. Coupled with aging infrastructure and the increased frequency of extreme weather events, there is concern about the future reliability and transmission capacity of conductors and adjacent components. This scan report seeks to provide an overview of mechanical solutions to challenges caused by extreme weather events associated with components of transmission and distribution infrastructure, including conductor heat sag, ice accumulation, wind, and wildfire. Many options could increase transmission capacity or reliability, and these are at various stages of technological readiness. Some have only been lab tested, while some have been widely deployed in the U.S. or overseas for decades. The solution categories and providers featured in this report are intended to be comprehensive at the time of publication and to serve as a reference for decision-makers concerned about transmission and distribution reliability. There are two other categories of large, complex solutions, which are not covered in this report: replacing existing conductors with advanced conductors and implementing digital grid enhancing technologies. A separate scan report titled “Advanced Conductor Scan Report,” which discusses advanced carbon-core conductors, was published by the Idaho National Laboratory (INL) in 2023. Information on digital technologies, such as dynamic line ratings, power-flow controllers, and other power electronics and communications-based devices, can be found on the Grid- Enhancing Technologies landing page. Mechanical grid-enhancing technologies, or solutions covered in this report, often do not require full equipment replacement and do not rely on digital components. Mechanical technologies are overlooked because they may be older, simpler, or seemingly “more obvious” than digital or carbon-core technologies. However, it is wise to consider mechanical solutions in a thorough evaluation of grid enhancing technology solutions.

24 - POWER TRANSMISSION AND DISTRIBUTION

Van de Graaff Irradiation Studies of Oxygen Sensor and Hydrated Zirconia Sorbent

Commercial-scale production of Mo-99 demands a facility-wide assessment of radiation-induced degradation across process equipment, instrumentation, and purification media. Key factors— total ionizing dose, dose rate, radiolysis-driven chemistry, thermal loads, activation, and any neutron-related effects—should inform material selection, shielding, and component layout. Purification materials (sorbents, resins, filters, seals, housing) require particular attention to ensure that irradiation does not alter selectivity or capacity, generate fines, or introduce leachables that could compromise Mo-99 purity or downstream Tc-99m generator performance. Dose mapping, accelerated irradiation testing, and studies of extractables/leachables together provide the basis for setting maintenance, calibration, and replacement intervals and for qualifying materials that retain mechanical integrity, chemical compatibility, and radiopurity over their service life.

36 MATERIALS SCIENCE

ARC disruption physics and strategy

Commonwealth Fusion Systems (CFS) plans to operate a tokamak power plant called ARC in the early 2030s. Tokamak plasmas have stability limits that, if crossed, lead to a rapid termination of the plasma, referred to as a disruption. Disruptions pose a melt risk to the first wall resulting from thermal and non-thermal particle heat fluxes, and an electromagnetic loading risk on all metal components within the equilibrium coils. A comprehensive set of models is used herein to provide an assessment of both mitigated and unmitigated ARC disruption loads. A preliminary massive gas injection system is baselined and a runaway electron mitigation coil option is proposed to close possible gaps in the baseline. It is predicted that all ARC disruption loads are within a factor of 2 of the disruption loads in SPARC, a tokamak presently under construction by CFS, and therefore SPARC provides an opportunity to calibrate models, test solutions and inform the design of ARC. The goal for ARC is disruption-free operation, however, the pragmatic design target is to withstand one mitigated disruption per day, and to restart the plasma following mitigation in tens of seconds without interrupting the power output. Unmitigated disruptions must be rare, and experience with unmitigated disruption impacts in SPARC will better define what rare means. The implications of this strategy for plasma disruptivity and disruption prediction are discussed, and operating the ARC scenario on SPARC is expected to refine the ARC final design and operational plan.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION

Neural correspondence to spectrum of environmental uncertainty in multiple-cue probability judgment system with time delay

Despite state-of-the-art technologies like artificial intelligence, human judgment is critically essential in cooperative systems, such as the multi-agent system (MAS), which collect information among agents based on multiple-cue judgment. Human agents can prevent impaired situational awareness of automated agents by confirming situations under environmental uncertainty. System error caused by uncertainty can result in an unreliable system environment, and this environment affects the human agent, resulting in non-optimal decision-making in MAS. Thus, it is necessary to know how human behavior is changed to capture system reliability under uncertainty. Another issue affecting MAS is time delay, which can delay agent information transfer, resulting in low performance and instability. However, it is difficult to find studies on the influence of time delay on human agents. This study is about understanding the human decision-making process under a specific system reliability environment by uncertainty with time delay. We used concepts of expected and unexpected uncertainty to implement reliability of the system usage environment with three types of time delay conditions: no time delay, regular time delay, and irregular time delay conditions. We used electroencephalogram (EEG) for human cognitive neural mechanisms in multiple-cue judgment systems to understand human decision-making. In the reliability of system usage environment, the unreliable system environment significantly creates less memory load by less utilization of system rules for decision-making. In terms of time delay, delayed information delivery does not significantly affect memory load for decision-making.

cognitive process

Systematic Catalyst Variation for Improved Stereoselective Epoxide Polymerization: Subtle Modifications Resulting in Superior Efficiency

Isotactic poly(propylene oxide) (iPPO) is a semicrystalline polyether that has emerged as a high-strength, photodegradable material for marine applications. To improve the accessibility of i PPO, catalysts with higher activity and selectivity are required. Using rational catalyst design informed by computational insights, we developed a flexibly tethered, bimetallic chromium catalyst exhibiting high enantioselectivity ( k rel ∼ 100) and unprecedented activity (TOF ∼ 50,000 h −1 ) for propylene oxide (PO) polymerization. Mechanistic studies reveal that high enantioselectivity originates from increased steric bulk at the ortho position of the salicylimine moiety, which increases steric repulsion between the alkoxide chain end and the ligand in the disfavored transition state. Furthermore, introducing geminal dimethyl groups that rigidify the flexible tether between the two ligand moieties significantly enhances catalyst activity by destabilizing the resting state during polymerization. The catalyst remains active at loadings as low as 0.5 ppm, enabling the synthesis of colorless, tough i PPO.

Ren, Bai-Hao [Cornell Univ., Ithaca, NY (United St

U-net architected deep material network training with microstructure local field information

The Deep Material Network (DMN) has recently emerged as a powerful reduced-order modeling framework for simulating the mechanical response of heterogeneous materials such as composites. Unlike most data-driven approaches that directly learn a material’s response under prescribed loading, the DMN acts as a homogenization operator, learning the kinematic constraints and mechanical interactions of the underlying microstructure. However, traditional DMN training relies exclusively on homogenized effective properties derived from Direct Numerical Simulations (DNS), discarding the rich local field data that govern microstructural interactions. In this work, we extend the DMN framework to incorporate such local field information into the offline training process. Utilizing a U-Net architecture, we augment the DMN training objective to include the first and second statistical moments of the local stress fields obtained from linear DNS. This ensures that the learned network topology not only fits the effective stiffness but also accurately reflects the internal local stress and strain partitioning of the microstructure. The results confirm that supervising the localization process during training yields a superior surrogate model, reducing local prediction errors by an order of magnitude and significantly improving generalization to unseen nonlinear constitutive behaviors compared to traditional DMNs.

36 MATERIALS SCIENCE

HDG-1 Experiment Irradiation Monitoring Data Qualification Final Report

SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS