Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “inductive loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Use of vacuum tubes in test instrumentation for measuring characteristics of fast high-voltage semiconductor devices

Circuits are described that permit measurement of fast events occurring in power semiconductors. These circuits were developed for the dynamic characterization of transistors used in inductive-load switching applications. Fast voltage clamping using vacuum diodes is discussed, and reference is made to a unique circuit that was built for performing nondestructive, reverse-bias, second-breakdown tests on transistors.

Berning, D.↗

Pulsed thyristor trigger control circuit

A trigger control circuit is provided for producing firing pulses for the thyristor of a thyristor control system such as a power factor controller. The control circuit overcomes thyristor triggering problems involved with the current lag associated with controlling inductive loads and utilizes a phase difference signal, already present in the power factor controller, in deriving a signal for inhibiting generation of a firing pulse until no load current is flowing from the preceding half cycle and thereby ensuring that the thyristor is triggered on during each half cycle.

Nola, F. J.↗

Hybrid power semiconductor

The voltage rating of a bipolar transistor may be greatly extended while at the same time reducing its switching time by operating it in conjunction with FETs in a hybrid circuit. One FET is used to drive the bipolar transistor while the other FET is connected in series with the transistor and an inductive load. Both FETs are turned on or off by a single drive signal of load power, the second FET upon ceasing conductions, rendering one power electrode of the bipolar transistor open. Means are provided to dissipate currents which flow after the bipolar transistor is rendered nonconducting.

Chen, D. Y.↗

Observation of Single-Event Burnout During Inductive Switching

1A power MOSFET demonstrated destructive Single-Event Effect (SEE) during ion irradiation in a switching circuit. Further investigation showed that the inductive load causing a spike in the drain-to-source voltage (VDS) that exceeded the manufacturer’s rating for several nanoseconds was enough to allow SEB. These results indicate that SEB may occur in a very short window and flyback is critical for disciplined power supply design.

Menke, Rob↗

SEED BANKS FOR MAGNETIC FLUX COMPRESSION GENERATORS

In recent years the Lawrence Livermore National Laboratory (LLNL) has been conducting experiments that require pulsed high currents to be delivered into inductive loads. The loads fall into two categories (1) pulsed high field magnets and (2) the input stage of Magnetic Flux Compression Generators (MFCG). Three capacitor banks of increasing energy storage and controls sophistication have been designed and constructed to drive these loads. One bank was developed for the magnet driving application (20kV {approx} 30kJ maximum stored energy.) Two banks where constructed as MFCG seed banks (12kV {approx} 43kJ and 26kV {approx} 450kJ). This paper will describe the design of each bank including switching, controls, circuit protection and safety.

42 ENGINEERING↗

The Advanced Helical Generator

A high explosive pulsed power (HEPP) generator called the Advanced Helical Generator (AHG) has been designed, built, and successfully tested. The AHG incorporates design principles of voltage and current management to obtain a high current and energy gain. Its design was facilitated by the use of modern modeling tools as well as high precision manufacture. The result was a first-shot success. The AHG delivered 16 Mega-Amperes of current and 11 Mega-Joules of energy to a quasi-static 80 nH inductive load. A current gain of 154 times was obtained with a peak exponential rise time of 20 {micro}s. We will describe in detail the design and testing of the AHG.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of the inductance of imploding wire array Z-pinches using measurements of load voltage

The inductance of imploding cylindrical wire array z-pinches has been determined from measurements of load voltage and current. A thorough analysis method is presented that explains how the load voltage of interest is found from raw signals obtained using a resistive voltage divider. This method is applied to voltage data obtained during z-pinch experiments carried out on the MAGPIE facility (1.4 MA, 240 ns rise-time) in order to calculate the load inductance and thereafter the radial trajectory of the effective current sheath during the snowplough implosion. Voltage and current are monitored very close to the load, allowing these calculations to be carried out without the need for circuit modelling. Measurements give a convergence ratio for the current of between 3.1 and 5.7 at stagnation of the pinch.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Local Voltage Support from Distributed Energy Resources to Prevent Air Conditioner Motor Stalling

Microgrid voltage collapse often happens when there is a high percentage of low inertia air-conditioning (AC) motors in the power systems. The stalling of the AC motors results in Fault Induced Delayed Voltage Recovery (FIDVR). A hybrid load model including typical building loads, AC motor loads, and other induction motor loads is built to simulate the motoring stalling phenomena. Furthermore, distributed energy resources (DE) with local voltage support capability are utilized to boost the local bus voltage during a fault, and prevent the motor stalling. The simulation results are presented. The analysis of the simulation results show that local voltage support from multiple DEs can effectively and economically solve the microgrid voltage collapse problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cross-Categorical Transfer Learning based Composite Load Protection Modeling

Protection equipment is used to prevent damage to induction motor loads by isolating them from power systems in the event of severe faults. Modeling the response of induction motor loads and their protection is vital for power system planning and operation, especially in understanding system's dynamic performance and stability after a fault occurs. Induction motors are usually equipped with several types of protection with different operation mechanisms, making it challenging to develop adequate yet not overly complex protection models and determine their parameters for aggregate induction motor models. This paper proposes a novel cross-categorical transfer learning based framework to determine protection model parameters for aggregate induction motor loads in commercial buildings. Introducing a mathematical abstraction, the task of determining a suitable set of parameters for the protection model in composite load models is formulated as a combination of feature extraction using transferable layers, followed by affine operations through non-transferable layers applied on the previous extracted features. Numerical results are provided to illustrate the application of the framework.

transfer learning, Stacked Autoencoder, Composite ↗

LANL studies of ESD spark energy discharge through September 2019

Two concentric-sphere apparatuses were used to measure the energies deposited by electric sparks through air to calibrated loads. Both sets of spheres had clean, uninsulated metal surfaces. The 127-mm diameter pair of spheres had a gap of 10 mm and a capacitance of 52 pF. The maximum energy stored on these spheres was 12 mJ and the maximum energy delivered to the 50-mΩ load was 11 µJ, with or without inductance. This load energy amounted to 0.09% of the available input energy; the remainder of the input energy was expended in forming the spark. The second set of spheres was 330 mm in diameter with a gap of 14 mm and a capacitance of 240 pF. The maximum energy stored on these spheres was 71 mJ and the maximum energy delivered to the 50-mΩ load was 150 µJ without added inductance. This load energy was 0.27% of the input energy; again, the remainder of the input energy was expended in forming the spark. The inclusion of 250 nH and 500 nH inductances in the discharge path of the smaller spheres caused the current discharges to resonate, but had little effect on the maximum energies deposited in the loads. At the time of writing, inductances had not yet been added to the larger spheres. The magnitudes of the observed spark discharges were stochastic, so more than 1200 tests were required to develop the statistical bounds of the spark behavior, i.e., to estimate the worst case (highest likely) energy depositions in the loads. The action integrals of the current discharges $∫ i^2dt$ were found to be approximately independent of the load resistances for loads of less than ~1 Ω. Hence the energy deposition scaled with resistance as 207 µJ/Ω and 2.93 mJ/Ω for the two apparatuses.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Operation of Grid Forming Converters as Self Excited Induction Generators Under Non-Ideal Loading Conditions

Self-excited induction generators offer a robust solution for power production for standalone as well as grid-connected systems. In general, self-excited induction generators require excitation capacitors which make use of the machine magnetization characteristics for voltage build up process as well as operation at a specific frequency. In this paper, a self-excited induction machine is modeled with both the electrical and mechanical dynamics. This modeled virtual machine's dynamics are utilized for voltage build up process for a standalone photovoltaic converter connected to a local load for a microgrid application. The modeled machine's parameters are used from the name plate rating from the manufacturer. However, in a microgrid the accommodation of unbalanced and/or nonlinear harmonic rich load is a necessity, therefore, in this work the virtual self-excitation capacitors of the modeled machine are varied based on the machine characteristics. With the objective of ensuring harmonic free point of common coupling voltage, the modeled virtual self-excitation capacitors are varied to accomplish change in terminal frequency and the virtual load torque is varied to obtain voltage magnitude change. To verify the efficacy, the overall system is modeled in MATLAB/Simulink and PLECS domain and most important case studies are presented.

grid forming converters (GFM)↗

Transient and Steady-state Tests of the Space Power Research Engine with Resistive and Motor Loads

The NASA Lewis Research Center (LeRC) has been testing free-piston Stirling engine/linear alternators (FPSE/LA) to develop advanced power convertors for space-based electrical power generation. Tests reported herein were performed to evaluate the interaction and transient behavior of FPSE/LA-based power systems with typical user loads. Both resistive and small induction motor loads were tested with the space power research engine (SPRE) power system. Tests showed that the control system could maintain constant long term voltage and stable periodic operation over a large range of engine operating parameters and loads. Modest resistive load changes were shown to cause relatively large voltage and, therefore, piston and displacer amplitude excursions. Starting a typical small induction motor was shown to cause large and, in some cases, deleterious voltage transients. The tests identified the need for more effective controls, if FPSE/LAs are to be used for stand-alone power systems. The tests also generated a large body of transient dynamic data useful for analysis code validation.

Rauch, Jeffrey S.↗

Inrush Current Mitigation for Grid-Forming Inverters in Islanded Microgrids

Virtual-inertia and droop control methods are commonly used for grid-forming inverters. While the virtual inertia is used to emulate the equation of motion/frequency, if the inverter output voltage is emulated as in synchronous generators, then the method is known as the virtual synchronous generator. An inductive pulse-load, e.g., a relatively large induction motor, connection to a microgrid fed only by grid-forming inverters may lead to blackout due to high inrush currents. This article presents virtual reactance techniques to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. This article also compares the virtual inertia and droop control methods under switching inductive-dynamic loads while the proposed techniques are implemented. Experimental tests are performed considering the linear and nonlinear virtual reactance techniques, and the findings are discussed. The mitigation significantly suppresses the inrush currents while the inverters can perform a normal operation. Furthermore, the frequency and power response of the virtual inertia control with different inertia settings to a sudden change in the load is analyzed. The virtual reactance technique is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented in this article.

Gursoy, Mehmetcan↗

A Dual-Active-Bridge Converter Employing a Variable Inductor Without an Auxiliary Circuit

This paper proposes a dual active bridge (DAB) converter employing a variable inductor (VI) without an auxiliary circuit. Unlike conventional VI-based designs that require an external DC bias circuit, the proposed DAB utilizes the input DC current itself as the bias source, enabling automatic inductance variation with load conditions. The inductance naturally increases at low power and decreases at high power, effectively extending the zero voltage switching (ZVS) range and reducing circulating current, respectively. The VI was experimentally implemented and characterized to obtain its inductance-current profile, which was then integrated into a PLECS model of the DAB converter for circuit and thermal simulations. Simulation results confirm that the proposed auxiliary-free VI-DAB converter achieves a wider ZVS range and lower circulating current compared with a conventional fixed-inductor DAB converter. By realizing a variable inductor without any auxiliary bias circuitry, the proposed approach maintains soft switching and reduces reactive current losses across a wide load range, leading to improved efficiency and simplified implementation.

Jo, Cheolhui [ORNL] (ORCID:0000000322692434)↗

Analysis of ICRH antenna loading data in TEXTOR obtained during gas injection experiments

The possibility of increasing the coupling of ICRH power to plasmas on TEXTOR by gas injection was investigated, for a given voltage applied at the input of an antenna pair. The antenna pair was operated in the conjugated T mode, D(H) heating was used. Modeling of the antenna by transmission line theory shows that load resilience is maintained in a broad range of independent resistance variation for each strap. It is found that the absolute value of the reflection coefficient can be maintained below 0.2 for typical values of resistance measured in plasma shots (2-10 {Omega}/m) in good matching conditions. During gas injection, the loading resistance showed a clear increase with increasing line average electron density measured close to the plasma edge. Evidence of fast wave eigenmodes was also found, as characteristic resonant behavior of loading resistance and antenna self-inductance, due to poor absorption in the plasma caused by high H minority concentration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Aggregate Protection Response of Motor Loads in Commercial Buildings

Protection plays a critical role in determining the dynamic response of the induction motor loads and the overall performance of composite load models when subjected to voltage sags or disturbances. Up to date, due to lack of understanding of the aggregate performance of the protection of motors, protection modeling of the motors becomes one of the least accurate parts in dynamic (composite) load models. This paper fills this gap by providing detailed analysis of the motor loads and their associated protection in commercial buildings and deriving the aggregate protection response based on integrated transmission and distribution dynamic co-simulation. The results showed that the aggregate protection response of motor loads varies significantly among different classes, which indicates the protection modeling that has been developed based on the assumption of similar or even identical responses and used in some composite load models need to be updated.

Huang, Qiuhua↗