Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “in-flight monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A high precision Solar Ultraviolet Spectral Irradiance Monitor for the wavelength region 120-400 nm

There exists a growing need to improve the accuracy of measurement of the absolute solar flux within the wavelength range 120-400 nm. Although full-disk solar fluxes and variations thereof in the 120-400 nm region are required to model the solar atmosphere, current increased interest in the measurements arises from their importance in modeling the terrestrial atmosphere. The Solar Ultraviolet Spectral Irradiance Monitor (SUSIM) experiment under development for flight aboard the Space Shuttle and the Upper Atmospheric Research Satellite is described. SUSIM will monitor the solar flux in the 120-144 nm region with high precision, using an in-flight calibration system to reduce absolute error to less than 10%, and error relative to the 400 nm continuum to less than 1%.

Vanhoosier, M. E.↗

Solar ultraviolet spectral irradiance monitor experiment on OSS-1

The need to improve the accuracy of measurement of the absolute solar flux within the wavelength range 120 nm to 400 nm requires an extensive effort in contamination control and in tracking the instruments' stability. The techniques used in the solar ultraviolet irradiance monitor are described. These methods resulted in very high calibration stability as proved by preflight and postflight calibration. In-flight calibrating and the pointing accuracy provided by the shuttle attitude control system are discussed.

Vanhossier, M. E.↗

Microelectronics bioinstrumentation systems

Microelectronic bioinstrumentation systems to be employed in the Cardiovascular Deconditioning Program were developed. Implantable telemetry systems for long-term monitoring of animals on earth were designed to collect physiological data necessary for the understanding of the mechanisms of cardiovascular deconditioning. In-flight instrumentation systems, microelectronic instruments, and RF powering techniques for other life science experiments in the NASA program were studied.

Ko, W. H.↗

Absolute radiometric calibration of advanced remote sensing systems

The distinction between the uses of relative and absolute spectroradiometric calibration of remote sensing systems is discussed. The advantages of detector-based absolute calibration are described, and the categories of relative and absolute system calibrations are listed. The limitations and problems associated with three common methods used for the absolute calibration of remote sensing systems are addressed. Two methods are proposed for the in-flight absolute calibration of advanced multispectral linear array systems. One makes use of a sun-illuminated panel in front of the sensor, the radiance of which is monitored by a spectrally flat pyroelectric radiometer. The other uses a large, uniform, high-radiance reference ground surface. The ground and atmospheric measurements required as input to a radiative transfer program to predict the radiance level at the entrance pupil of the orbital sensor are discussed, and the ground instrumentation is described.

Slater, P. N.↗

Absolute radiometric calibration of advanced remote sensing systems

The distinction between the uses of relative and absolute spectroradiometric calibration of remote sensing systems is discussed. The advantages of detector-based absolute calibration are described, and the categories of relative and absolute system calibrations are listed. The limitations and problems associated with three common methods used for the absolute calibration of remote sensing systems are addressed. Two methods are proposed for the in-flight absolute calibration of advanced multispectral linear array systems. One makes use of a sun-illuminated panel in front of the sensor, the radiance of which is monitored by a spectrally flat pyroelectric radiometer. The other uses a large, uniform, high-radiance reference ground surface. The ground and atmospheric measurements required as input to a radiative transfer program to predict the radiance level at the entrance pupil of the orbital sensor are discussed, and the ground instrumentation is described. Previously announced in STAR as N83-28544

Slater, P. N.↗

Flight test of 4-Hz and 30-Hz Omega receiver front-end

In-flight information was gathered on two Omega receiver analog modules, one having a 4-Hz bandwidth and the other a 30-Hz bandwidth. The Mini-O receiver was also monitored. An improved signal-to-noise characteristic of the narrower bandwidth front-end with negligible loss in dynamic range indicates that the 4-Hz front-end is the more desirable for the prototype Omega receivers. The Mini-O receiver was found to function quite satisfactorily on its second test flight, and has a very real potential for a low-cost, low-power, compact and light-weight Omega receiver.

Wright, L.↗

ATS-6 flight accelerometers

Five accelerometers mounted near the adapter base of the Titan 3-C launch vehicle and three on the hub of the ATS-F spacecraft provided (1) data for verifying basic spacecraft mode shapes and frequencies during powered flight while attached to the launch vehicle; (2) failure mode detection and diagnostic information on in-flight anomalies; and (3) data to be used in the design of future spacecraft to be flown on the Titan 3-C. Because data from the instruments mounted on the spacecraft hub passed through an in-flight disconnect at the separation plane between the transtage and ATS-F, the moment this connector was broken, the signal to the telemetry system showed a step function change. By monitoring these telemetry traces on the ground at appropriate times during flight sequences, a positive indication of spacecraft separation was obtained. Flight data showing dynamic response at spacecraft launch vehicle interface and at the top of ATS spacecraft during significant launch events are presented in tables.

Mattson, R.↗

A real-time computer for monitoring a rapid-scanning Fourier spectrometer

A real-time Fourier computer has been designed and tested as part of the Lunar and Planetary Laboratory's program of airborne infrared astronomy using Fourier spectroscopy. The value and versatility of this device are demonstrated with specific examples of laboratory and in-flight applications.

Michel, G.↗

Recommendations of the panels: Panel on in-flight measurements

The attenuation factor for aircraft other than the B-747 in reducing the ambient ozone concentrations which enter the cabin is obtained. The need to continue NASA Global Air Sampling Program measurements was expressed for three main purposes; testing new filters, correlation of complaints with ozone levels, and ambient ozone data. The need to continue cooperation between NASA and industry is indicated. Concern with regard to the correlation of ozone levels and complaints was given. The need to measure the variability of ozone within the aircraft cabin was investigated. The requirement for an onboard ozone monitor on all aircraft is discussed.

Rogers, J.↗

Autonomous failure detection and correction on Landsat-4

An integrated hardware/software fault tolerant system for an earth oriented, computer controlled spacecraft is described. The design philosophy as well as the rationale behind the chosen fault tolerant system is outlined. In-flight performance of the system is included for several different instances where the Failure Detection and Correction system acted autonomously to protect the spacecraft. This system exceeded the expectations of the designers by demonstrating the capability to provide a measure of safety to the spacecraft for inadvertent and undesirable ground commands as well as satisfying its primary function of monitoring the flight hardware and software for failures.

Welch, R. V.↗

Results of Skylab medical experiment M171: Metabolic activity

The experiment was conducted to establish whether man's ability to perform mechanical work would be progressively altered as a result of exposure to the weightless environment of space flight. The Skylab crewmen exercised on a bicycle ergometer at workloads approximating 25, 50, and 75 percent of their maximum aerobic capacity. The physiological parameters monitored were respiratory gas exchange, blood pressure, and vectorcardiogram/heart rate. The results of these tests indicate that the crewmen had no significant decrement in their responses to exercise during their exposure to zero gravity. The results of the third manned Skylab mission (Skylab 4) are presented and a comparison is made of the overall results obtained from the three successively longer Skylab manned missions. The Skylab 4 crewmembers' 84-day in-flight responses to exercise were no worse and were probably better than the responses of the crewmen on the first two Skylab missions. Indications that exercise was an important contributing factor in maintaining this response are discussed.

Michel, E. L.↗

In-orbit performance of the soft X-ray imaging telescope Xtend aboard XRISM

Here, we present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently operating X-ray observatories. XRISM/Xtend has a large field of view of ${38{^{\prime }_{.}}5}$ $\times$ ${38{^{\prime }_{.}}5}$, covering an energy range of 0.4–13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170–180 eV at 6 keV, which meets the mission requirement and enables us to resolve He-like and H-like Fe K$\alpha$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in the Soft X-ray Imager (SXI) onboard the previous Hitomi mission—light leakage and crosstalk events—are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C 273 results in an effective area measured to be $\sim$420 cm$^{2}$ at1.5 keV and $\sim$310 cm$^{2}$ at 6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations; the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared with other major X-ray instruments onboard satellites, combined with the largest grasp ($\Omega _{\rm eff}\sim 60$ cm$^2$ deg$^2$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near-future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

instrumentation: detectors: Xtend↗

NASA Scout ST-1 Flight-Test Results and Analyses, Launch Operations, and Test Vehicle Description

The first of a series of flight tests for the development of the four-stage, solid-propellant Scout vehicle was conducted at the NASA Wallops Station under the direction of the Langley Research Center. Vehicle designation for the test was NASA Scout ST-1. Performance characteristics of the vehicle and components were recorded during a high-altitude probe mission. Flight-simulation studies are presented and show that the accuracy of the guidance system during the flight was within control-system design specifications. The control system functioned normally during the flight with the exception of an overpowering of the reaction-control roll jets near burnout of the third-stage rocket motor. The resulting roll displacement of the vehicle is shown to have caused the monitor tracking radar which had been erroneously tracking a radar beacon in the vehicle on a side lobe to reorient to the major lobe of the receiving antenna. This tracking switch falsely indicated a violent turning maneuver on the monitor plot board and resulted in a hold-fire decision for the fourth-stage rocket motor. Although data for the final thrusting and coast phase of the flight were not obtained, the majority of the test objectives were achieved. In-flight thrust misalignment angles for the second- and third-stage rocket motors derived from control-system error data and for the first-stage motor determined from flight-simulation studies are presented. All rocket-motor thrust misalignment angles were well within the tolerances used for control-system design. Rocket-motor flight performance is presented, and velocity increments attained from the first three stages substantiated the predicted nominal performance. Operation of the rocket motors was satisfactory with the exception of high-level vibrations which were encountered during third-stage motor burning. Rolling moments which overpowered the reaction-control jets are also attributed to the burning characteristics of the third-stage motor. A discussion of the premature loss of the third-stage heat shield is given and shows that the heat-shield latching mechanism failed from pressure loads as the vehicle entered the transonic speed range. Although venting was provided to relieve the high negative pressures known to exist on the heat shield at these speeds, a field modification of the wiring tunnel had the same effect as opening the inside of the heat shield to ambient pressures. Consequently, the latching mechanism failed from pressure loads which were of about the same magnitude as the latching-mechanism yield loads. Skin temperatures were recorded at several locations on the vehicle and were generally in good agreement with theoretical values. Aerodynamic heating presented no problem during the flight since the maximum temperatures recorded during the flight were only about half the design values because of the high-launch-angle trajectory. Environmental vibrations recorded in the vicinity of the guidance package showed that no significant continuous amplitude levels above the general instrumentation noise level were present during first- and second-stage burning. Large vibration amplitudes were recorded during third-stage burning which coincided with the large roll disturbance experienced by the vehicle near burnout of the third-stage motor.

Scout Launch Vehicle↗

Integrated Real Time Contamination Monitor IRTCM

Engineering and design work was performed on a monitoring device for particulate and gas contamination to be used in the space shuttle cargo area during launch at altitudes up to 50 km and during return phases of the flight. The gas sampling device consists of ampules filled with specific absorber materials which are opened and/or sealed at preprogrammed intervals. The design eliminates the use of valves which, according to experiments, are never sealing properly at hard vacuum. Methods of analysis including in-flight measuring possibilities are discussed.

Luttges, W. E.↗

Flight control experiences

A multidisciplinary medical-management team at mission control provided Skylab crew support by monitoring health, retrieving and compiling experimental data, assisting in the development of flight plans, and by contributing to in-flight procedures and checklists. Real time computers assisted the flight crews in performing medical and other experiments.

Musgrave, F. S.↗

Instrumentation for controlling and monitoring environmental control and life support systems

Advanced Instrumentation concepts for improving performance of manned spacecraft Environmental Control and Life Support Systems (EC/LSS) have been developed at Life Systems, Inc. The difference in specific EC/LSS instrumentation requirements and hardware during the transition from exploratory development to flight production stages are discussed. Details of prior control and monitor instrumentation designs are reviewed and an advanced design presented. The latter features a minicomputer-based approach having the flexibility to meet process hardware test programs and the capability to be refined to include the control dynamics and fault diagnostics needed in future flight systems where long duration, reliable operation requires in-flight hardware maintenance. The emphasis is on lower EC/LSS hardware life cycle costs by simplicity in instrumentation and using it to save crew time during flight operation.

Yang, P. Y.↗

ROLM computers in the flight testing of the Fokker F29 aircraft

The design, development, installation, and operation of the test equipment (MRVS) is discussed. The main feature of the MRVS is continuous recording on an instrumentation recorder data of up to 1500 parameters with a total sample rate of up to 10,000 samples per second. In order to compress the evaluation and calibration time period, the following additional requirements were set for two test systems: (1) recording of selected parameters, time tagged on computer compatible tape (CCT); (2) recording of selected high bandwidth signals and ad hoc parameters on analog tape; (3) onboard presentation of calibrated parameter data, in engineering units, in numerical as well as graphical form for: system checkout during pre-, in- and post-flight, and quick look analysis during in-flight; (4) real time presentation on the ground by telemetry for: flight monitoring, takeoff and landing measurements, and noise measurements; and (5) data processing on the ground on the Fokker-NLR computer network.

Manders, P. J.↗

In-flight testing of the space shuttle orbiter thermal control system

In-flight thermal control system testing of a complex manned spacecraft such as the space shuttle orbiter and the considerations attendant to the definition of the tests are described. Design concerns, design mission requirements, flight test objectives, crew vehicle and mission risk considerations, instrumentation, data requirements, and real-time mission monitoring are discussed. An overview of the tests results is presented.

Taylor, J. T.↗