Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Development of a PET/Cerenkov-light hybrid imaging system

Purpose: Cerenkov-light imaging is a new molecular imaging technology that detects visible photons from high-speed electrons using a high sensitivity optical camera. However, the merit of Cerenkov-light imaging remains unclear. If a PET/Cerenkov-light hybrid imaging system were developed, the merit of Cerenkov-light imaging would be clarified by directly comparing these two imaging modalities. Methods: The authors developed and tested a PET/Cerenkov-light hybrid imaging system that consists of a dual-head PET system, a reflection mirror located above the subject, and a high sensitivity charge coupled device (CCD) camera. The authors installed these systems inside a black box for imaging the Cerenkov-light. The dual-head PET system employed a 1.2 × 1.2 × 10 mm{sup 3} GSO arranged in a 33 × 33 matrix that was optically coupled to a position sensitive photomultiplier tube to form a GSO block detector. The authors arranged two GSO block detectors 10 cm apart and positioned the subject between them. The Cerenkov-light above the subject is reflected by the mirror and changes its direction to the side of the PET system and is imaged by the high sensitivity CCD camera. Results: The dual-head PET system had a spatial resolution of ∼1.2 mm FWHM and sensitivity of ∼0.31% at the center of the FOV. The Cerenkov-light imaging system's spatial resolution was ∼275μm for a {sup 22}Na point source. Using the combined PET/Cerenkov-light hybrid imaging system, the authors successfully obtained fused images from simultaneously acquired images. The image distributions are sometimes different due to the light transmission and absorption in the body of the subject in the Cerenkov-light images. In simultaneous imaging of rat, the authors found that {sup 18}F-FDG accumulation was observed mainly in the Harderian gland on the PET image, while the distribution of Cerenkov-light was observed in the eyes. Conclusions: The authors conclude that their developed PET/Cerenkov-light hybrid imaging system is useful to evaluate the merits and the limitations of Cerenkov-light imaging in molecular imaging research.

60 APPLIED LIFE SCIENCES↗

Stereoscopic wide field of view imaging system

A stereoscopic imaging system incorporates a plurality of imaging devices or cameras to generate a high resolution, wide field of view image database from which images can be combined in real time to provide wide field of view or panoramic or omni-directional still or video images.

Prechtl, Eric F.↗

Stereoscopic wide field of view imaging system

A stereoscopic imaging system incorporates a plurality of imaging devices or cameras to generate a high resolution, wide field of view image database from which images can be combined in real time to provide wide field of view or panoramic or omni-directional still or video images.

Prechtl, Eric F.↗

Developing a high-speed terahertz imaging system based on parametric upconversion imaging for penetrative sensing

Imaging using THz waves has been a promising option for penetrative measurements in environments that are opaque to visible wavelengths. However, available THz imaging systems have been limited to relatively low frame rates and cannot be applied to study fast dynamics. This work explores the use of upconversion imaging techniques based on nonlinear optics to enable wavelength-flexible high frame rate THz imaging. UpConversion Imaging (UCI) uses nonlinear conversion techniques to shift the THz wavelengths carrying a target image to shorter visible or near-IR wavelengths that can be detected by available high-speed cameras. This report describes the analysis methodology used to design a prototype high-rate THz UCI system and gives a detailed explanations of the design choices that were made. The design uses a high-rate pulse-burst laser system to pump both THz generation and THz upconversion detection, allowing for scaling to acquisition rates in excess of 10 kHz. The design of the prototype system described in this report has been completed and all necessary materials have been procured. Assembly and characterization testing is on-going at the submission of this report. This report proposes future directions for work on high-rate THz UCI and potential applications of future systems.

47 OTHER INSTRUMENTATION↗

Visible wide angle view imaging system of KTM tokamak based on multielement image fiber bundle

In the paper, new visible wide angle view imaging system of KTM tokamak is described. The system has been designed to observe processes inside of plasma and the processes occurring due to plasma-wall interactions through the long equatorial port. Imaging system is designed based on special image fiber bundle and entrance wide angle lens, which provide image of large section of the vacuum chamber, both poloidal half-section and divertor through the sufficiently long equatorial port. The system also consists of two video cameras: slow and fast with image intensifier. Commercial equipment had been used in design of the system that allowed reducing the cost and time for research and development. The paper also discusses advantages and disadvantages of the system in comparison with conventional endoscopes based on a lens system and considers its promising utilization in future tokamaks and future steady state fusion reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution, continuous field-of-view (FOV), non-rotating imaging system

A high resolution CMOS imaging system especially suitable for use in a periscope head. The imaging system includes a sensor head for scene acquisition, and a control apparatus inclusive of distributed processors and software for device-control, data handling, and display. The sensor head encloses a combination of wide field-of-view CMOS imagers and narrow field-of-view CMOS imagers. Each bank of imagers is controlled by a dedicated processing module in order to handle information flow and image analysis of the outputs of the camera system. The imaging system also includes automated or manually controlled display system and software for providing an interactive graphical user interface (GUI) that displays a full 360-degree field of view and allows the user or automated ATR system to select regions for higher resolution inspection.

Huntsberger, Terrance L.↗

Flame Imaging System

A system for imaging a flame and the background scene is discussed. The flame imaging system consists of two charge-coupled-device (CCD) cameras. One camera uses a 800 nm long pass filter which during overcast conditions blocks sufficient background light so the hydrogen flame is brighter than the background light, and the second CCD camera uses a 1100 nm long pass filter, which blocks the solar background in full sunshine conditions such that the hydrogen flame is brighter than the solar background. Two electronic viewfinders convert the signal from the cameras into a visible image. The operator can select the appropriate filtered camera to use depending on the current light conditions. In addition, a narrow band pass filtered InGaAs sensor at 1360 nm triggers an audible alarm and a flashing LED if the sensor detects a flame, providing additional flame detection so the operator does not overlook a small flame.

Barnes, Heidi L.↗

Occupational and patient exposure as well as image quality for full spine examinations with the EOS imaging system

Purpose: EOS (EOS imaging S.A, Paris, France) is an x-ray imaging system that uses slot-scanning technology in order to optimize the trade-off between image quality and dose. The goal of this study was to characterize the EOS system in terms of occupational exposure, organ doses to patients as well as image quality for full spine examinations. Methods: Occupational exposure was determined by measuring the ambient dose equivalents in the radiological room during a standard full spine examination. The patient dosimetry was performed using anthropomorphic phantoms representing an adolescent and a five-year-old child. The organ doses were measured with thermoluminescent detectors and then used to calculate effective doses. Patient exposure with EOS was then compared to dose levels reported for conventional radiological systems. Image quality was assessed in terms of spatial resolution and different noise contributions to evaluate the detector's performances of the system. The spatial-frequency signal transfer efficiency of the imaging system was quantified by the detective quantum efficiency (DQE). Results: The use of a protective apron when the medical staff or parents have to stand near to the cubicle in the radiological room is recommended. The estimated effective dose to patients undergoing a full spine examination with the EOS system was 290μSv for an adult and 200 μSv for a child. MTF and NPS are nonisotropic, with higher values in the scanning direction; they are in addition energy-dependent, but scanning speed independent. The system was shown to be quantum-limited, with a maximum DQE of 13%. The relevance of the DQE for slot-scanning system has been addressed. Conclusions: As a summary, the estimated effective dose was 290μSv for an adult; the image quality remains comparable to conventional systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Up Periscope! Designing a New Perceptual Metric for Imaging System Performance

Modern electronic imaging systems include optics, sensors, sampling, noise, processing, compression, transmission and display elements, and are viewed by the human eye. Many of these elements cannot be assessed by traditional imaging system metrics such as the MTF. More complex metrics such as NVTherm do address these elements, but do so largely through parametric adjustment of an MTF-like metric. The parameters are adjusted through subjective testing of human observers identifying specific targets in a set of standard images. We have designed a new metric that is based on a model of human visual pattern classification. In contrast to previous metrics, ours simulates the human observer identifying the standard targets. One application of this metric is to quantify performance of modern electronic periscope systems on submarines.

imaging↗

Scanning Terahertz Heterodyne Imaging Systems

Scanning terahertz heterodyne imaging systems are now at an early stage of development. In a basic scanning terahertz heterodyne imaging system, (see Figure 1) two far-infrared lasers generate beams denoted the local-oscillator (LO) and signal that differ in frequency by an amount, denoted the intermediate frequency (IF), chosen to suit the application. The LO beam is sent directly to a mixer as one of two inputs. The signal beam is focused to a spot on or in the specimen. After transmission through or reflection from the specimen, the beams are focused to a spot on a terahertz mixer, which extracts the IF outputs. The specimen is mounted on a translation stage, by means of which the focal spot is scanned across the specimen to build up an image.

Siegel, Peter↗

Radiation imaging system

A radiation imaging system includes a casing and a camera disposed inside the casing. A first field of view through the casing exposes the camera to light from outside of the casing. An image plate is disposed inside the casing, and a second field of view through the casing to the image plate exposes the image plate to high-energy particles produced by a radioisotope outside of the casing. An optical reflector that is substantially transparent to the high-energy particles produced by the radioisotope is disposed with respect to the camera and the image plate to reflect light to the camera and to allow the high-energy particles produced by the radioisotope to pass through the optical reflector to the image plate.

47 OTHER INSTRUMENTATION↗

Radiation imaging system

A radiation imaging system includes a casing and a camera disposed inside the casing. A first field of view through the casing exposes the camera to light from outside of the casing. An image plate is disposed inside the casing, and a second field of view through the casing to the image plate exposes the image plate to high-energy particles produced by a radioisotope outside of the casing. An optical reflector that is substantially transparent to the high-energy particles produced by the radioisotope is disposed with respect to the camera and the image plate to reflect light to the camera and to allow the high-energy particles produced by the radioisotope to pass through the optical reflector to the image plate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gimbaled multispectral imaging system and method

A gimbaled multispectral imaging system and method is described herein. In an general embodiment, the gimbaled multispectral imaging system has a cross support that defines a first gimbal axis and a second gimbal axis, wherein the cross support is rotatable about the first gimbal axis. The gimbaled multispectral imaging system comprises a telescope that fixed to an upper end of the cross support, such that rotation of the cross support about the first gimbal axis causes the tilt of the telescope to alter. The gimbaled multispectral imaging system includes optics that facilitate on-gimbal detection of visible light and off-gimbal detection of infrared light.

47 OTHER INSTRUMENTATION↗

Weekly Update -- Scintillators and Mobile Imaging System

The Neutron Imaging (NI) project is developing innovative tools that will allow multimodal imaging and high-quality CT imaging of dense objects. To realize these goals a Flat Panel Detector (FPD) has been procured and novel scintillating materials are being investigated. A compact, mobile neutron imaging system is being designed and components procured

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A time-resolved imaging system for the diagnosis of x-ray self-emission in high energy density physics experiments

A diagnostic capable of recording spatially and temporally resolved x-ray self-emission data was developed to characterize experiments on the MAGPIE pulsed-power generator. The diagnostic used two separate imaging systems: a pinhole imaging system with two-dimensional spatial resolution and a slit imaging system with one-dimensional spatial resolution. The two-dimensional imaging system imaged light onto the image plate. The one-dimensional imaging system imaged light onto the same piece of image plate and a linear array of silicon photodiodes. This design allowed the cross-comparison of different images, allowing a picture of the spatial and temporal distribution of x-ray self-emission to be established. The design was tested in a series of pulsed-power-driven magnetic-reconnection experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗