Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Search for New Physics through a Long-Lived Di-Muon Resonance in the NuMI Beam with the ICARUS Detector

Many of the unexplained phenomena in particle physics and cosmology today, such as the microphysical nature of dark matter, the strong CP problem, and the origin of the neutrino masses, can be resolved by the existence of a light (~GeV), weakly-coupled hidden sector of new physics. Such hidden sectors often predict the existence of “long-lived” particles (LLPs) that travel a far distance from production before decaying into Standard Model particles. Neutrino oscillation experiments, which combine intense particle beams with precise imaging detectors, are well equipped to probe LLP models with new sensitivity. This thesis details a search for a long-lived particle decaying to two muons with the ICARUS liquid argon time projection chamber (LArTPC) neutrino detector in the Short-Baseline Neutrino program at Fermilab. The calibration of the ICARUS time projection chamber (TPC) which enables the search is also presented. Notably, the calibration measures an angular dependence in electron-ion recombination in argon, a novel effect in the detector physics of LArTPCs. The search is performed using data taken with the Neutrinos at the Main Injector (NuMI) beam, with an exposure of 2.41e20 protons on target. No significant excess over background is observed, and we set world-leading limits on two new physics models that predict this process: the Higgs portal scalar and a heavy axion model. We also present the sensitivity in a model-independent way applicable to any new physics model predicting the process K → π + S(→μμ), for a long-lived particle S.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Commission < 5 µm spatial resolution x-ray imager for High Resolution Turbulence experiments

This report presents the successful development, commissioning, and deployment of the Scintillation-Based X-ray Imager (SBXI) for the High-Resolution Turbulence (HRT) campaign at the National Ignition Facility (NIF). The SBXI system was designed to overcome the spatial resolution and efficiency limitations of conventional x-ray imaging detectors. Through careful system engineering, rigorous laboratory characterization, and experimental validation at NIF, the SBXI has demonstrated spatial resolution at the object plane of 5 μm (±0.5 μm) and a detective quantum efficiency (DQE) of 34% at 7.2 keV, both of which surpass the requirements set by the campaign, and meeting the L2 milestone. The system’s deployment enables high-fidelity imaging of fine-scale hydrodynamic instabilities, directly supporting advanced turbulence model validation and future high energy density physics research.

42 ENGINEERING↗

The imaging Time-of-Propagation detector at Belle II

Here, we report on the construction, operation, and performance of the Time-of-Propagation detector with imaging used for the Belle II experiment running at the Super-KEKB e + e - collider. This detector is located in the central barrel region and uses Cherenkov light to provide particle identification among hadrons. The Cherenkov light is radiated in highly polished bars of synthetic fused silica (quartz) and transported to the ends of the bars via total internal reflection. One bar end is instrumented with finely segmented micro-channel-plate photomultiplier tubes to record the light, while the other end has a mirror attached to reflect the photons back to the instrumented end. Both the propagation times and hit positions of the Cherenkov photons are measured; these depend on the Cherenkov angle and together provide good discrimination among charged pions, kaons, and protons with momenta up to around 4 GeV/ c . To date, the detector has been used to record and analyze almost 600 fb −1 of Belle II data.

43 PARTICLE ACCELERATORS↗

Advances in Autoradiography Systems for Nuclear Forensic Analysis

Nuclear forensic analysis techniques work to determine the contents of radiological samples with nondestructive and destructive analysis methods. Autoradiography is a nondestructive analysis method that creates an image of the distribution of radioactivity within the sample. These images allow the location of the radiological content within a sample to be ascertained, which can be used for further analysis. Autoradiography has been used since the discovery of radiation and has been continuously developed to better suit the needs of the medical, nuclear security, nuclear safeguards, and nuclear forensic communities. Recent developments in autoradiography have led to a higher spatial resolution down to a level of tens of microns, real-time capabilities that minimize the risk of overexposure, and the ability to discriminate particles. All of these developments in autoradiography would assist the nuclear forensics community in understanding the placement of radiological content within a sample and in understanding the locations of beta-particle interactions versus those for alpha-particle interactions. This article aims to discuss the history of autoradiography as well as multiple different autoradiographic technologies while focusing on imaging plates, the BeaQuant system, and the ionizing-radiation Quantum Imaging Detector system. This article reviews three autoradiographic techniques and detectors, discusses how they relate to nuclear forensics, and addresses the drawbacks and benefits of each detector.

Autoradiography↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Specimen-displacement correction for powder X-ray diffraction in Debye–Scherrer geometry with a flat area detector

The effect of small changes in the specimen-to-detector distance on the unit-cell parameters is examined for synchrotron powder diffraction in Debye–Scherrer (transmission) geometry with a flat area detector. An analytical correction equation is proposed to fix the shift in 2θ values due to specimen capillary displacement. This equation does not require the use of an internal reference material, is applied during the Rietveld refinement step, and is analogous to the specimen-displacement correction equations for Bragg–Brentano and curved-detector Debye–Scherrer geometry experiments, but has a different functional form. The 2θ correction equation is compared with another specimen-displacement correction based on the use of an internal reference material in which new integration and calibration parameters of area-detector images are determined. Example data sets showing the effect of a 3.3 mm specimen displacement on the unit-cell parameters for 25°C CeO 2 , including both types of displacement correction, are described. These experiments were performed at powder X-ray diffraction beamlines at the National Synchrotron Light Source II at Brookhaven National Laboratory and the Advanced Photon Source at Argonne National Laboratory.

36 MATERIALS SCIENCE↗

SpeckleNN: a unified embedding for real-time speckle pattern classification in X-ray single-particle imaging with limited labeled examples

With X-ray free-electron lasers (XFELs), it is possible to determine the three-dimensional structure of noncrystalline nanoscale particles using X-ray single-particle imaging (SPI) techniques at room temperature. Classifying SPI scattering patterns, or `speckles', to extract single-hits that are needed for real-time vetoing and three-dimensional reconstruction poses a challenge for high-data-rate facilities like the European XFEL and LCLS-II-HE. Here, we introduce SpeckleNN, a unified embedding model for real-time speckle pattern classification with limited labeled examples that can scale linearly with dataset size. Trained with twin neural networks, SpeckleNN maps speckle patterns to a unified embedding vector space, where similarity is measured by Euclidean distance. We highlight its few-shot classification capability on new never-seen samples and its robust performance despite having only tens of labels per classification category even in the presence of substantial missing detector areas. Without the need for excessive manual labeling or even a full detector image, our classification method offers a great solution for real-time high-throughput SPI experiments.

47 OTHER INSTRUMENTATION↗

28nm front end ASIC and 12” LGADs for 3D integration

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (≈10 μm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present the design and results from a 28 nm CMOS ASIC prototype, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. We also report on the co-design and characterization of reticle-scale LGAD sensors with 50 μm and 100 μm pixels and introduce the next 10k-pixel ASIC designed for full 3D integration. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

47 OTHER INSTRUMENTATION↗

Pixelated plastic scintillator array manufacturing using fast-, photo-curable resin

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This article presents a fabrication method based on additive manufacturing for two-dimensional plastic organic scintillator arrays using a custom-built automated assembly machine and a custom photocurable resin that has significant non-aromatic acrylate oligomer content. The process involves two main stages: fully autonomous production of one-dimensional layered arrays, followed by semi-autonomous cutting and stacking to form two-dimensional pixel arrays. One-dimensional arrays were manufactured at a rate of around 4 layers per hour with minimal defects and tight dimensional tolerances, while two-dimensional arrays up to 7 x 7 pixels and 70 mm in length were completed in approximately 3.5 hours. Final arrays exhibited dimensional deviations of less than 0.5 mm. Two-dimensional arrays read out by a multi-anode photomultiplier tube demonstrated per-pixel position resolution and pulse-shape discrimination, enabling gamma–neutron interaction separation in mixed radiation environments.

36 MATERIALS SCIENCE↗

Shape- and Orientation-Dependent Scattering of Isolated Gold Nanostructures Using Polarized Dark-Field Microscopy

In this work, we demonstrate a simple and robust method for measuring the shape- and orientation-dependent optical scattering of various plasmonic nanostructures adsorbed onto a solid surface using polarized dark-field microscopy. By analyzing the dark-field scattering images of gold nanostructures using grazing incidence polarized light with a bench-top microscope, we are able to correlate optical scattering from the individual nanostructures with their shape and orientation. Depending on the size, shape, and orientation of the plasmonic nanostructures, they exhibit characteristic angle- and polarization-dependent scattering signals. Extracting the red, green, and blue channels of the scattering signals from a color-imaging detector as a function of azimuthal angle provides a polar plot of color intensity values that is characteristic of the underlying nanostructure. Examples are presented for various nanostructures, including spherical nanoparticles, nanotriangles, and nanorods. Experimental results are complemented by numerical calculations of the scattering spectra of representative model nanostructures. We demonstrate that the polarization- and orientation-dependent scattering behavior is a consequence of various localized surface plasmon modes existing in the nanostructures and can be used to verify the shape of individual objects as well as quickly identify the orientation of numerous objects on a densely populated substrate. We anticipate that this method will provide a rapid and efficient complement to the typical structural analysis of nanoparticles that is achieved by electron microscopy as well as providing a simple method for generating detailed information of the optical scattering of various types of individual plasmonic nanostructures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of a mock up nuclear waste package using energy resolved MeV neutron analysis

Reliable radiographic methods for characterizing nuclear waste packages non-destructively (without the need to open containers) have the potential to significantly contribute to safe handling and future disposal options, particularly for legacy waste of unknown content. Due to required shielding of waste containers and the need to characterize materials consisting of light elements, X-ray methods are not suitable. Here, energy-resolved MeV neutron radiography is demonstrated as a first-of-its-kind application for non-destructive and remote examination of mock up nuclear waste packages from a safe position using time-of-flight techniques enabled by a novel event-mode imaging detector system. Energy-resolved neutron transmission spectra were measured spatially, permitting the detection of analogue materials to actual nuclear waste such as water, melamine, and ion exchange resin within a 2.54 cm wall thickness steel pipe. The results demonstrate the capability to locate the materials through this wall thickness by radiography and tomographic reconstruction, revealing detailed 3D distributions and structural anomalies. The method effectively detects residual water in ion exchange resin, highlighting its sensitivity to moisture content, a crucial parameter for nuclear waste characterization. Monte Carlo simulations are in agreement with the experimental findings, providing a pathway to simulate waste forms more difficult to tackle experimentally. This work paves the way to apply sub-nanosecond intense MeV neutron sources, such as laser-driven neutron sources under development, to nuclear waste characterization.

36 MATERIALS SCIENCE↗

Slicing Newton spheres with a two-camera 3D imaging system

We demonstrate a simple approach to achieve three-dimensional ion momentum imaging. The method employs two complementary metal–oxide–semiconductor cameras in addition to a standard microchannel plates/phosphor screen imaging detector. The two cameras are timed to measure the decay of luminescence excited by ion hits to extract the time of flight. The achieved time resolution is better than 10 ns, which is mainly limited by camera jitters. A better than 5 ns resolution can be achieved when the jitter is suppressed.

Chemistry↗

Molecular-Resolution Electron Imaging of Defects and Dynamics at the Ice-Water Interface

Water crystallization into hexagonal ice (type I h ) is one of the most critical processes relevant to the Earth’s environment and human activities. However, despite recent breakthroughs in imaging non-equilibrium condensed ice structures, the ice-water interface has never been imaged at a molecular resolution. This is primarily due to the low stability of the hydrogen bonds in ice under high-resolution microscopy conditions and a lack of methods to prepare compatible samples. Here, this presentation describes the first molecular-resolution imaging of ice crystallized from liquid water and the ice-water interface using high-resolution transmission electron microscopy (HRTEM). By encapsulating deionized (DI) water between two amorphous carbon (a-C) TEM grids and subsequently freezing it with liquid N 2 on a cryo sample stage, we generated two types of ice: non-equilibrium, condensed ice from the atmosphere and encapsulated ice from the DI water (Fig. 1A). Condensed ice usually shows irregular, spherulitic shapes (Fig. 1B). Selected area electron diffraction (SAED) shows that they are a mixture of cubic and hexagonal crystals (Fig. 1C). On the contrary, encapsulated ice forms thin films that contain large-area single-crystalline regions of hexagonal ice oriented along the [0001] zone axis (Fig. 1D). Differential electron energy-loss spectroscopy (EELS) confirmed the high purity of the encapsulated ice free from organic contaminations that are common in other encapsulation methods for HRTEM such as graphene liquid cells. These single-crystalline areas are robust under the electron beam up to ~100 e/Å 2 s. Aberration-corrected HRTEM imaging in these areas achieved a line resolution of ~1.3 Å (Fig. 1E and F). This platform allows us to study near-equilibrium ice structures and dynamics at an unprecedented spatial resolution (Fig. 2). For example, we discovered subdomain-rich regions near the defective crystal edges despite the structure appearing single-crystalline according to diffraction criteria. These subdomains connect via low-angle grain boundaries with flat energy landscapes as a function of tilt angles (according to simulations), showing the high tolerance of ice to defect structures. When we tuned the sample temperature and electron flux rate, we observed radiolysis-controlled bubble generation and dissolution in ice single crystals near a steady state of bubble dynamics. Furthermore, rich beam-induced melting and recrystallization dynamics were observed at the ice-water interface with lattice resolution. These data represent the first observation of the ice-water phase transformation at the sub-nanometer level. In summary, the methods developed in this work enabled molecular-resolution observations of ice and the ice-water interface and shed light on the microstructures and phase transformation pathways. Finer control on the temperature, electron irradiation profile, and imaging detector could eventually lead to real-time observation of ice nucleation in water and address long-standing questions in the nucleation pathways.

74 ATOMIC AND MOLECULAR PHYSICS↗

PvaPy streaming framework for real-time data processing

User facility upgrades, new measurement techniques, advances in data analysis algorithms as well as advances in detector capabilities result in an increasing amount of data collected at X-ray beamlines. Some of these data must be analyzed and reconstructed on demand to help execute experiments dynamically and modify them in real time. In turn, this requires a computing framework for real-time processing capable of moving data quickly from the detector to local or remote computing resources, processing data, and returning results to users. In this paper, we discuss the streaming framework built on top of PvaPy, a Python API for the EPICS pvAccess protocol. We describe the framework architecture and capabilities, and discuss scientific use cases and applications that benefit from streaming workflows implemented on top of this framework. We also illustrate the framework's performance in terms of achievable data-processing rates for various detector image sizes.

EPICS pvAccess↗

Distinguishing isotropic and anisotropic signals for X-ray total scattering using machine learning

Understanding structure–property relationships is essential for advancing technologies based on thin films. X-ray pair distribution function (PDF) analysis can access relevant atomic structure details spanning local-, mid- and long-range structure. While X-ray PDF has been adapted for thin films on amorphous substrates, measurements on single-crystal substrates are necessary to accurately determine structure origins for some thin film materials, especially those for which the substrate changes the accessible structure and properties. However, when measuring films on single-crystal substrates, high-intensity anisotropic Bragg spots saturate 2D detector images, overshadowing the thin films' isotropic scattering signal. This renders previous data processing methods for films on amorphous substrates unsuitable for films on single-crystal substrates. To address this measurement need, we developed IsoDAT2D, an innovative data processing approach using unsupervised machine learning algorithms. The program combines dimensionality reduction and clustering algorithms to separate thin film and single-crystal substrate X-ray scattering signals. We use SimDAT2D , a program we developed to generate simulated thin film data, to validate IsoDAT2D . Here we also use IsoDAT2D to isolate X-ray total scattering signal from a thin film on a single-crystal substrate. The resulting PDF data are compared with similar data processed using previous methods, especially substrate subtraction for single-crystal and amorphous substrates. PDF data from IsoDAT2D -identified X-ray total scattering data are significantly better than from single-crystal substrate subtraction, but not as reliable as PDF data from amorphous substrate subtraction. With IsoDAT2D , there are new opportunities to expand PDF to a wider variety of thin films, including those on single-crystal substrates, with which new structure–property relationships can be elucidated to enable fundamental understanding and technological advances.

36 MATERIALS SCIENCE↗