Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hydrogen station”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Hydrogen Component Leak Rate Quantification for System Risk and Reliability Assessment through QRA and PHM Frameworks: Preprint

The National Renewable Energy Laboratory's (NREL) Hydrogen Safety Research and Development (HSR&D) program in collaboration with the University of Maryland's Systems Risk and Reliability Analysis Laboratory (SyRRA) are working to improve reliability and reduce risk in hydrogen systems. This approach strives to use quantitative data on component leaks and failures, together with Prognosis and Health Management (PHM), and Quantitative Risk Assessment (QRA) to identify at-risk components, reduce component failures and downtime, and predict when components require maintenance. Hydrogen component failures increase facility maintenance cost, facility downtime, and reduce public acceptance of hydrogen technologies, ultimately increasing facility size and cost because of potentially overly conservative requirements. Leaks are a predominant failure mode for hydrogen components. However, uncertainties in the amount of hydrogen emitted from leaking components and the frequency of those failure events limit the understanding of the risks that they present under real-world operational conditions. NREL has deployed a test fixture, the Leak Rate Quantification Apparatus (LRQA), to quantify the mass flow rate of leaking gases from medium and high-pressure components that have failed while in service. Quantitative hydrogen leak rate data from this system could ultimately be used to better inform risk assessment and Regulation Codes and Standards (RCS). Parallel activity explores the use of PHM and QRA techniques to assess and reduce risk, thereby improving safety and reliability of hydrogen systems. The results of QRAs could further provide a systematic and science-based foundation for the design and implementation of RCS, as in the latest versions of the NFPA 2 code for gaseous hydrogen stations. Alternatively, data-driven techniques of PHM could provide new damage diagnosis and health-state prognosis tools. This research will help end users, station owners and operators, and regulatory bodies move towards risk-informed preventative maintenance versus emergency corrective maintenance, reducing cost and improving reliability. Predictive modelling of failures could improve safety and affect RCS requirements such as setback distances at liquid refuelling sites. The combination of leak rate quantification research, PHM, and QRA can lead to better informed models enabling data-based decision to be made for hydrogen system safety improvements.

codes and standards↗

International Space Station Nickel-Hydrogen Battery Start-Up and Initial Performance

International Space Station (ISS) Electric Power System (EPS) utilizes Nickel-Hydrogen (Ni-H2) batteries as part of its power system to store electrical energy. The batteries are charged during insolation and discharged during eclipse. The batteries are designed to operate at a 35% depth of discharge (DOD) maximum during normal operation. Thirty eight individual pressure vessel (IPV) Ni-H2 battery cells are series-connected and packaged in an Orbital Replacement Unit (ORU). Two ORUs are series-connected utilizing a total of 76 cells, to form one battery. The ISS is the first application for low earth orbit (LEO) cycling of this quantity of series-connected cells. The P6 Integrated Equipment Assembly (IEA) containing the initial ISS high-power components was successfully launched on November 30, 2000. The IEA contains 12 Battery Subassembly ORUs (6 batteries) that provide station power during eclipse periods. This paper will describe the battery hardware configuration, operation, and role in providing power to the main power system of the ISS. We will also discuss initial battery start-up and performance data.

Cohen, Fred↗

International Space Station Nickel-Hydrogen Batteries Approached 3-Year On-Orbit Mark

The International Space Station's (ISS) electric power system (EPS) employs nickel-hydrogen (Ni-H2) batteries as part of its power system to store electrical energy. The batteries are charged during insolation and discharged, providing station power, during eclipse. The batteries are designed to operate at a maximum 35-percent depth of discharge during normal operation. Thirty-eight individual pressure vessel Ni-H2 battery cells are series-connected and packaged in an orbital replacement unit (ORU), and two ORUs are series-connected, using a total of 76 cells, to form one battery. When the ISS is in its assembly-complete form, the electrical power system will have a total of 24 batteries (48 ORUs) on-orbit. The ISS is the first application for low-Earth-orbit cycling of this quantity of series-connected cells.

Dalton, Penni J.↗

Techno-economic and environmental assessment of solar-based electrical vehicles charging stations integrated with hydrogen production

With the growing interest in adopting both commercial and residential electric vehicles (EVs) utilizing green renewable energy, the techno-economic assessment of EV charging stations with solar energy is a critical aspect of the transition to sustainable transportation. However, battery storage capacity for variable solar energy production is becoming increasingly less cost-effective due to the higher Lithium price. Complementing solar energy production and battery storage, the potential of combining green hydrogen fuel energy integration with solar energy for EV charging stations can provide a sustainable alternative to reach carbon-free transportation. This research aims to assess the technical and economic viability of grid-connected Photovoltaic (PV)-based EV charging stations across Kentucky based on existing EV load profiles. The study considers different PV system sizes, locations, orientations, and the impact of net metering policies and electricity tariffs on the profitability of the PV systems. Further, using excess PV energy, Lithium-Ion batteries will be charged, which will be assessed considering the techno-economic and environmental impacts of green EV charging stations. To further enhance green renewable energy production, we also investigated the feasibility of on-grid PV-based EV charging stations with Lithium-Ion batteries charged during low tariff periods. In comparison with these scenarios, we studied the potential benefits of integrating green hydrogen energy production using excess solar energy with and without governmental incentives. Furthermore, we assess the environmental impact of these green EV charging stations across Kentucky. Our study indicates that EV stations across Kentucky have similar techno-economic feasibility with insignificant deviation in the levelized cost of electricity, payback period, and PV energy fraction with/without Li-Ion batteries. However, with green hydrogen production, the marginal H 2 production cost indicates the first scenario (on-grid PV energy charging) is the most significant, roughly 10 USD/Kg, which is similar to 1.5 times higher than the second (charging during low-tariff periods) and the third scenarios (power grid to satisfy the demand deficit - approximately 6.5 USD/Kg). From the environmental perspective, the second scenario would be a good option for either hybrid EV/H 2 or EV charging stations in Kentucky, factoring in the hydrogen production cost and the carbon footprint.

08 HYDROGEN↗

Development of dispensing hardware for safe fueling of heavy duty vehicles

The development of safe dispensing equipment for the fueling of heavy duty (HD) vehicles is critical to the expansion of this newly and quickly expanding market. This paper discusses the development of a HD dispenser and nozzles assembly (nozzle, hose, breakaway) for these new, larger vehicles where flow rates are more than double compared to light duty (LD) vehicles. This equipment must operate at nominal pressures of 700 bar, -40o C gas temperature, and average flow rate of 5-10 kg/min at a high throughput commercial hydrogen fueling station without leaking hydrogen. The project surveyed HD vehicle manufacturers, station developers, and component suppliers to determine the basic specifications of the dispensing equipment and nozzle assembly. The team also examined existing codes and standards to determine necessary changes to accommodate HD components. From this information, the team developed a set of specifications which will be used to design the dispensing equipment. In order to meet these goals, the team performed computational fluid dynamic, pressure modelling, and temperature analysis in order to determine the necessary parameters to meet existing safety standards modified for HD fueling. The team also considered user, operational, and maintenance requirements, such as freeze lock which has been an issue which prevents the removal of the nozzle from LD vehicles. The team also performed a failure mode and effects analysis (FMEA) to identify the possible failures in the design. The dispenser and nozzle assembly will be tested separately, and then installed on an innovative, HD fueling station which will use a HD vehicle simulator to test the entire system.

08 HYDROGEN↗

Basic statistical analyses of candidate nickel-hydrogen cells for the Space Station Freedom

Nickel-Hydrogen (Ni/H2) secondary batteries will be implemented as a power source for the Space Station Freedom as well as for other NASA missions. Consequently, characterization tests of Ni/H2 cells from Eagle-Picher, Whittaker-Yardney, and Hughes were completed at the NASA Lewis Research Center. Watt-hour efficiencies of each Ni/H2 cell were measured for regulated charge and discharge cycles as a function of temperature, charge rate, discharge rate, and state of charge. Temperatures ranged from -5 C to 30 C, charge rates ranged from C/10 to 1C, discharge rates ranged from C/10 to 2C, and states of charge ranged from 20 percent to 100 percent. Results from regression analyses and analyses of mean watt-hour efficiencies demonstrated that overall performance was best at temperatures between 10 C and 20 C while the discharge rate correlated most strongly with watt-hour efficiency. In general, the cell with back-to-back electrode arrangement, single stack, 26 percent KOH, and serrated zircar separator and the cell with a recirculating electrode arrangement, unit stack, 31 percent KOH, zircar separators performed best.

Maloney, Thomas M.↗

Renewable Hydrogen to Vehicle (RH2V) – Operation Verification and Risk Mitigation Studies: Original Agreement (Modification 0) (CRADA Final Report)

Toyota has announced plans for commercial fuel cell vehicle deployment in 2015. To fully realize the benefits of fuel cell vehicles (zero emission with no performance loss in terms of vehicle range and capability), hydrogen produced efficiently from renewable sources is necessary. Most of the hydrogen fueling stations today utilize hydrogen reformed from natural gas (produced onsite or delivered). This enables more stations to be deployed cost-effectively within a network. Producing and using cost-effective renewable hydrogen in fuel cell vehicles will enable realization of the full potential. A viable option of green hydrogen that reliably delivers on the full suite of benefits for Toyota fuel cell vehicle drivers is needed. NREL is in a unique position to analyze and optimize renewable hydrogen production scenarios using the Energy Systems Integration Facility (ESIF), a facility that is specifically designed to evaluate renewable energy integration technologies. As the U.S. Department of Energy's (DOE) primary national laboratory for renewable energy and energy efficiency research and development, NREL has extensive knowledge of photovoltaic systems as well as alternative renewable technologies for efficient and reliable production of green hydrogen.

08 HYDROGEN↗

A 25-LBF gaseous oxygen/gaseous hydrogen thruster for space station application

A prototype 25 lb sub f gaseous oxygen/gaseous hydrogen thruster for Space Station propulsion application was designed and fabricated by Rocketdyne and endurance tested at the NASA/Marshall space Flight Center. The thruster incorporates a regeneratively cooled thrust chamber with a nozzle exit area ratio of 30, a 12-element coaxial injector, a spark igniter, and close-coupled propellant valves. Test results indicate that all major technology issues for long-life gaseous oxygen/gaseous hydrogen thrusters for Space Station application have been resolved.

Heckert, B. J.↗

International Space Station Nickel-Hydrogen Battery Startup and Initial Performance

The Battery Orbital Replacement Unit (ORU) was designed to meet the following requirements: a 6.5-year design life, 38,000 charge/discharge Low Earth Orbit cycles, 81-Amp-hr nameplate capacity, 4 kWh nominal storage capacity, contingency orbit capability, an operating temperature of 5 +/- 5 C standard orbit and 5+5/-10 C contingency orbit, a non-operating temperature of -25 to +30 C, a five-year Mean Time between failure, an on-orbit replacement using ISS robotic interface, and one launch to orbit and one return to ground. The ISS electrical power system is successfully maintaining power for all on-board loads. ISS Eclipse power is currently supplied by six Ni-H2 batteries (12 ORUs), which are operating nominally.

Dalton, Penni↗

Efficient and Safe Hydrogen Refueling of Fuel Cell Vehicles from an Emergency Chemical Hydride Storage Source

Zero-emissions hydrogen fuel cell electrical vehicles (FCEVs) have become more popular in recent years. However, the limited availability of hydrogen fueling stations is considered a critical barrier to sustainable adoption of hydrogen FCEV. To enable the widespread deployment and commercialization of hydrogen FCEV, the availability of hydrogen refueling stations needs to improve. One of the consequences of the lack of hydrogen refueling infrastructure is that consumers can suffer from “range anxiety”, meaning consumers would get anxious of running out of fuel during long-distance trip [4]. A practical solution is to provide a compact emergency hydrogen refueler that can be used if the consumer runs out of hydrogen before reaching the nearest hydrogen refueling station. A safe, compact, and user-friendly hydrogen refueler would give consumers the flexibility they need to feel comfortable using their hydrogen FCEV when planning a long-distance trip. Offering this product would alleviate range anxiety, and it would make Hydrogen FCEV a more attractive alternative to gasoline vehicles. The emergency hydrogen refueler consists of a lithium hydride bed that reacts with liquid water to produce hydrogen gas and lithium hydroxide.

08 HYDROGEN↗

Measurements of stratospheric hydrogen cyanide at McMurdo Station, Antarctica - Further evidence of winter stratospheric subsidence?

Measurements of hydrogen cyanide in the springtime Antarctic stratosphere were made using ground-based millimeter wave spectroscopy. A steeper decrease in volume mixing ratio with altitude was found, than that found at tropical latitudes, from an assumed value of about 160 pptv in the troposphere to a value of 65 + or - 30 pptv at 40 km, which may be further evidence of substantial vertical subsidence of the Antarctic winter stratosphere.

Jaramillo, M.↗

A Renewably Powered Hydrogen Generation and Fueling Station Community Project

The proposed project goal is to encourage the use of renewable energy and clean fuel technologies for transportation and other applications while generating economic development. This can be done by creating an incubator for collaborators, and creating a manufacturing hub for the energy economy of the future by training both white- and blue-collar workers for the new energy economy. Hydrogen electrolyzer fueling stations could be mass-produced, shipped and installed in collaboration with renewable energy power stations, or installed connected to the grid with renewable power added later.

Lyons, Valerie J.↗

The Port of Los Angeles Zero- and Near-Zero-Emission Freight Facilities Shore to Store Project

The City of Los Angeles Harbor Department (Harbor Department, Port of Los Angeles) partnered with Equilon Enterprises LLC (d/b/a Shell Oil Products US) (Shell), Toyota Motor North America (Toyota), and Kenworth Truck Company (Kenworth) partnered with the Port of Hueneme, United Parcel Service, Total Transportation Services Inc., Southern Counties Express, Toyota Logistics Services, Air Liquide, National Renewable Energy Laboratory, Coalition For A Safe Environment, and the South Coast Air Quality Management District to introduce hydrogen fuel into the Southern California drayage truck market by demonstrating near-commercial heavy-duty hydrogen fuel cell electric trucks at and between freight facilities throughout the region, while continuing to lay the groundwork for battery-electric operations. The Shore to Store project built on project team experience to help realize our vision of zero-emission freight operations in the future. Ten Kenworth zero-emission Class 8 fuel cell electric trucks, integrated with Toyota’s fuel cell drive technology, were operated by United Parcel Service, Total Transportation Services Inc., Southern Counties Express, and Toyota Logistics Services in commercial service. The demonstration fleet fueled at the Shore to Store hydrogen fueling stations that were built in Ontario, California, and Wilmington, California. An additional station at the Port of Long Beach (Portal Station) was available for fueling the fleet. Portal Station was supported by grants from the California Energy Commission and South Coast Air Quality Management District and used as match funding for the Shore to Store project. The Port of Hueneme demonstrated two battery-electric yard tractors, and Toyota Logistics Services demonstrated two zero-emission forklifts at their warehouse facility, showcasing elements of the entire supply chain operating with zero emissions. This project showcased a snapshot of the zero-emission supply chain of the future, providing a model by which freight facilities can support zero-emission operations. The Shore to Store project: Demonstrated the technical feasibility of zero-emission hydrogen fueled Class 8 heavy-duty trucks and electric cargo handling equipment in rigorous goods movement operation throughout the Southern California region. Cumulatively completed 59,212 miles of zero-emission operation, with 21,650 miles driven in-service with the fleets, using hydrogen fuel cell electric Class 8 heavy-duty trucks. Operated zero-emission yard tractors for a total of 2,749.6 hours. Created direct localized emission reductions in designated disadvantaged communities, including those in zip codes 90220, 90247, 90248, 90731, 90744, 90802, and 91761. For the 59,212 miles of zero-emission operation, reduced emissions by an estimated total of 15.5 kg NOX (0.163 g/km), 1.01 kg SOX (0.0106 g/km), and 304.8 metric tonnes of CO2e (3.2 kg/km) compared to diesel baseline vehicles including both tailpipe emissions and the emissions from producing the fuel sources.

08 HYDROGEN↗

Populating the Hydrogen Component Reliability Database (HYCRED) with Incident Data from Hydrogen Dispensing

Safety, risk, and reliability issues are vital to ensure the continuous and profitable operation of hydrogen technologies. Quantitative risk assessment (QRA) has been used to enable the safe deployment of engineering systems, especially hydrogen fueling stations. However, QRA studies require reliability data which are essential to collect to make the studies as realistic and relevant as possible. These data are currently lacking and data from other industries, such as oil and gas, are used in hydrogen system QRAs. This may lead to inaccurate results since hydrogen fueling stations have differences in physical properties, system design, and operational parameters when compared to other fueling stations, thus necessitating new data sources are necessary to capture the effects of these differences. To address this gap, we developed a structure for a hydrogen component reliability database, (HyCReD) [1], which could be used to generate reliability data to be used in QRA studies. In this paper, we demonstrate populating the HyCReD database with information extracted from new narrative reports on hydrogen fueling station incidents, specifically focused on the dispensing processes. We analyze five new events and demonstrate the feasibility of populating the database and types of meaningful insights that can be obtained at this stage.

component reliability↗

Reference Station Risk Assessment for Refueling Heavy-Duty Vehicles Using HyRAM+

The deployment of heavy-duty (HD) hydrogen fuel cell vehicles that are entering the market now is driving the need for expanded HD hydrogen refueling station infrastructure to meet demand. This expansion must prioritize safety and reliability, necessitating careful consideration of the associated risks. In this study, we use a light-duty (LD) hydrogen refueling station as a comparative tool to quantify the risks for a HD station, which is essentially a scaled-up version of a LD station.

08 HYDROGEN↗

Oxygen-hydrogen thrusters for Space Station auxiliary propulsion systems

The feasibility and technology requirements of a low-thrust, high-performance, long-life, gaseous oxygen (GO2)/gaseous hydrogen (GH2) thruster were examined. Candidate engine concepts for auxiliary propulsion systems for space station applications were identified. The low-thrust engine (5 to 100 lb sub f) requires significant departure from current applications of oxygen/hydrogen propulsion technology. Selection of the thrust chamber material and cooling method needed or long life poses a major challenge. The use of a chamber material requiring a minimum amount of cooling or the incorporation of regenerative cooling were the only choices available with the potential of achieving very high performance. The design selection for the injector/igniter, the design and fabrication of a regeneratively cooled copper chamber, and the design of a high-temperature rhenium chamber were documented and the performance and heat transfer results obtained from the test program conducted at JPL using the above engine components presented. Approximately 115 engine firings were conducted in the JPL vacuum test facility, using 100:1 expansion ratio nozzles. Engine mixture ratio and fuel-film cooling percentages were parametrically investigated for each test configuration.

Berkman, D. K.↗

Roundtable on Foundational Science for Carbon-Neutral Hydrogen Technologies (Technology Status Document)

This document summarizes the status of carbon-neutral hydrogen production, storage and transport, and utilization. The state of the art in the implementation, limitations, and challenges of these technologies are summarized. Sources of hydrogen are broadly categorized as hydrcoarbons or water and the processes used to convert these sources to hydrogen as catalytic, thermochemical, or electrochemical. Catalytic steam methane reforming of methane is the dominant process today. Other processes have smaller production volumes and the technology is less mature, but are being deployed at increasing rates, most notably water electrolyzers for hydrogen fueling stations. Efficient transport and storage of hydrogen is one of the major challenges facing a hydrogen-based energy economy. This arises in part from its low volumetric energy density necessitating very high pressures or cryogenic temperatures to store sufficient amounts for practical applications. High-pressure compressed hydrogen cylinders are the incumbent hydrogen storage technology for applications such as light-duty fuel cell electric vehicles, for example. The storage of hydrogen in materials or in chemicals is being pursued to address the issues associated with compression, such as parasitic energy loss and weight, size, and cost of storage containers. The complex nature of the chemical and physical processes involved in the uptake, storage, and release of hydrogen has slowed the discovery of suitable hydrogen storage materials. Both small and large-scale storage face the challenge of embrittlement of the storage media by hydrogen. There is a myriad of uses of hydrogen offering the promises of improving the efficiency of various applications and reducing or eliminating CO 2 emissions. These range from direct electrochemical conversion to electricity to power vehicles and grid-level stationary applications to combustion to production of chemicals and commodities. One of the most impactful applications in terms of reduction of CO 2 emissions is fuel cell passenger vehicles and heavy-duty vehicles such as class 8 trucks. The challenges facing widespread deployment of fuel cells, beyond the major hurdle of the lack of a hydrogen distribution infrastructure, are cost and durability, primarily related to the precious metal cathode catalyst and its durability. The other uses of hydrogen from conversion to hydrocarbons, polymer upcycling, and upgrading of bio-oils are at varying stages of maturity and also face fundamental challenges associated with catalytic processes and materials.

08 HYDROGEN↗

H2@Scale CRADA: CA Research Consort. (Ref. Station, Fueling Perf. Test Device, Station Cap Model)

In support of DOE's H2@Scale initiative, this project leverages with national lab capabilities at SNL, NREL, and ANL with collaboration and funding cost share from California agencies (CEC, South Coast AQMD, and GO-Biz) to enable the build-out of heavy-duty (HD) hydrogen fueling stations with large dispensing capacity and high flow rates by providing tools and information that lead to more efficient design, acceptance, and commissioning. In this presentation, we describe the progress as related to the subtasks of: HD Reference Station Design, HD Station Test Device Design, and the Station Capacity Model.

AMR↗