Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “home performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Affordable Solid Panel "Perfect Wall" System

The SPS is an innovative interpretation of the “perfect wall” concept, in which environmental control layers are located on the exterior side of the structural components, as opposed to traditional cavity insulated, stud-framed walls. The primary objective of this study is to validate the SPS technology in terms of its constructability, cost, and performance. Specifically for this project, we partnered with two affordable housing nonprofits in Minnesota—Twin Cities Habitat for Humanity and Urban Homeworks—to build five new houses using SPS walls, as well as two high-performance stud-framed comparison homes. We also reviewed cost and performance data from 13 SPS homes built prior to this project by MonoPath and Spero Environmental Builders. Reviewing the outcomes of these 20 homes total, we find promising results in terms of constructability, cost, and performance, although more structural performance data are needed before this new technology can see widespread adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The role of above-code labeling programs in reducing CO 2 e emissions in residential buildings

Residential buildings account for 15 % of total U.S. carbon dioxide (CO 2 ) emissions. Voluntary, above-code labeling programs, such as the ENERGY STAR and Zero Energy Ready Home programs, can play a crucial role in reducing the carbon footprint of the new construction residential building sector by encouraging adoption of more energy-efficient and lower emissions building practices and technologies. It's important for the industry to understand the carbon dioxide equivalent (CO 2 e) and energy cost savings potential of these programs. Here, to estimate the potential CO 2 e emissions savings for homes built to above-code labeling program levels, it is imperative to have reliable and accurate tools for estimating emissions from buildings. The open-source OpenStudio-ERI workflow employs detailed physics-based building energy modeling (BEM) to estimate energy usage and operational CO 2 e emissions. In this study we use the OpenStudio-ERI workflow and regional, time-varying emissions factors from the Cambium database to compare the CO 2 e emissions and energy costs of homes built to performance levels required by these above-code labeling programs relative to homes built to model energy codes. We present the results of our analysis and provide a range of emissions and annual energy cost savings for the above-code labeling programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GHEP WIBT (Guidelines for Home Energy Professionals Weatherization Installer Badges Toolkit) [SWR-20-69]

The National Renewable Energy Laboratory (NREL) and the U.S. Department of Energy's (DOE) Weatherization Assistance Program (WAP) are collaborating with the home energy retrofit industry to support the development of skilled workers. The Installer Badges Toolkit provides a flexible, customizable, and voluntary approach to training and skills recognition for WAP implementers, utility programs, private-sector workers, and contractors. In Fiscal Year 2018, DOE, along with the Crew Leader scheme committee, determined the Retrofit Installer Technician (RIT) Job Task Analysis (JTA) could be eliminated and its tasks inserted in the Crew Leader JTA. The RIT tasks became the basis of the Installer Badges. The Badges Toolkit was updated in 2020 to add licensing and copyright agreements. Users must cite the copyright information when using or distributing copies of the Badges Toolkit in any way. The technical content has remained unchanged from previous versions of the Badges Toolkit. The Toolkit for home retrofits consists of 25 Badges, each representing different energy efficiency tasks that an installer could perform on a home. Each Badge defines the desired outcome, criteria to verify, applicable material requirements, and references to Standard Work Specifications (SWS) or other relevant standards. The Badges provide a consistent approach to training by ensuring that installers in different regions are learning the same skills nationwide. Organizations can also customize the Toolkit by choosing only those Badges that are relevant to their program. The Badges Toolkit includes five pieces: "How to Use the Badges Toolkit" provides a brief overview of how a Grantee, Subgrantee, or training provider may approach using the toolkit. The "Badges Toolkit: Worksheet" includes what to consider when determining whether and how to best incorporate the Badges into a weatherization assistance program. The "Crew Leader Job Task Analysis Spreadsheet" indicates how the Badges align with specific areas of the JTA. The "Installer Badges Passport" features separate pages for each Badge, which include places for the installer and the supervisor/trainer to record the number of times a task has been successfully completed. The "Installer Badges Verification Criteria" includes sample inspection checklists for each Badge. These can be modified as needed based on approved variance requests or more stringent requirements. They also provide a basis for consistent inspections and awarding of Badges. Note: All elements of the Badges Toolkit are designed for use by potential program implementers. They are not off-the-shelf products intended for immediate deployment. Program implementers must review and modify as needed, revise verification criteria to match local requirements, complete worksheets, and otherwise define the parameters of their own badging program.

Desai, Jal↗

Analysis of precooling optimization for residential buildings

To reduce peak demand and/or energy cost for residential buildings, optimal precooling strategies are becoming important as an alternative to rule-based precooling strategies that are intuitive but may not be optimal. Since precooling optimization is heavily dependent on a variety of factors such as the home thermal properties, HVAC system, weather, thermal comfort criteria, and utility rate structure, the individual and collective impact of these factors on precooling performance needs to be analyzed. In addition, since the indoor air temperature is affected by heat transfer to and from the interior wall surface, performance analysis in view of the interior wall surface temperature is also essential. Therefore, in this paper, an optimal precooling strategy that accounts for the aforementioned factors and utilizes a second-order thermal network model, is proposed. With this strategy, the HVAC on/off control signal that minimizes 24-hour energy cost while maintaining thermal comfort, is determined. Through extensive simulations, it is found that the proposed optimal precooling strategy is able to adapt to changing conditions and that having a sufficiently low interior wall surface temperature during precooling is critical for avoiding expensive on-peak operation. Here, the reason for the latter is that such a temperature indicates that enough “cooling energy” has been stored. It is also found that weather has the most dominant impact on the precooling performance, followed by home thermal condition, with the rated cooling capacity and utility rate structure having the least impact.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Synthesis of Optimum Homing Missile Guidance Systems with Statistical Inputs

An analytical approach is presented which is applicable to the optimization of homing navigation guidance systems which are forced to operate in the presence of radar noise. The two primary objectives are to establish theoretical minimum miss distance performance and a method of synthesizing the optimum control system. The factors considered are: (1) target evasive maneuver, (2) radar glint noise, (3) missile maneuverability, and (4) the inherent time-varying character of the kinematics. Two aspects of the problem are considered. In the first, consideration is given only to minimization of the miss distance. The solution given cannot be achieved in practice because the required accelerations are too large. In the second, results are extended to the practical case where the limited acceleration capabilities of the missile are considered by placing a realistic restriction on the mean-square acceleration so that system operation is confined to the linear range. Although the exact analytical solution of the latter problem does not appear feasible, approximate solutions utilizing time-varying control systems can be found. One of these solutions - a range multiplication type control system - is studied in detail. It is shown that the minimum obtainable miss distance with a realistic restriction on acceleration is close to the absolute minimum for unlimited missile maneuverability. Furthermore, it is shown that there is an equivalence in performance between the homing and beam-rider type guidance systems. Consideration is given to the effect of changes in target acceleration, noise magnitude, and missile acceleration on the minimum miss distance.

Stewart, Elwood C.↗

Evaluation of Exterior Shades at PNNL Lab Homes and Occupied Field Sites (Final Report)

In residential applications, heat transfer through windows accounts for a significant portion of a home’s cooling load. Exterior shades are window attachments that can be applied on the exterior-side of windows in a home. Exterior shades can reduce solar heat gain, reduce glare through a window, and improve comfort in the home. To assess the performance of residential exterior shades, the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (BTO) commissioned a series of field studies for exterior fabric shades to be performed by Pacific Northwest National Laboratory (PNNL) during the cooling seasons of 2019 and 2020. This report describes the experimental setup and results of these exterior shade field studies. PNNL, in collaboration with Lawrence Berkeley National Laboratory (LBNL), evaluated exterior shades at the PNNL Lab Homes and three occupied field sites in Richland, Washington. At the Lab Homes, the energy performance of exterior shades was evaluated in a controlled side-by-side environment. At the occupied field sites, exterior shades were characterized by measuring shade usage, documenting installation practices, and surveying customer perspectives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Low-Cost Minisplit Heat Pump Connection System

This project was funded by SCE's Emerging Technologies Program, and evaluates the feasibility of a connection system that can pave the path to accelerated, cost-effective adoption of high-efficiency Minisplit Heat Pump (MSHP) systems. This report details the characterization of this connection system and a heat pump enabled with this technology in a laboratory setting, and assesses the energy and cost impact applicable to residential buildings in SCE service territory. The energy and economic analysis leverages NREL's ResStock TM modeling approach based on the EnergyPlus ® hourly simulation platform. The connection system can be incorporated into existing MSHP architectures. This reduces installation time from 10 to 20 man hours to approximately one hour or less, dramatically lowering total installation costs without adversely impacting heat pump performance. This report characterizes the connection system's leakage performance while connected and disconnected, as well as leakage over several connection/disconnection cycles, commensurate with manufacturer specifications for the individual components. The connector was incorporated into an off-the-shelf MSHP. Performance was compared to an identical unmodified heat pump. The connector had no impact on performance. Large-scale hourly energy simulations were performed for 22,574 homes across 15 counties in SCE service territory. The analysis was performed using baseline assumptions about the penetrations of window air conditioners (~18%) and six upgrade scenarios for these air conditioners. All scenarios assumed 100% adoption of the Connector-Supported Heat Pump (CSHP) in place of window air conditioners: MSHPs at Seasonal Energy Efficiency Ratio (SEER) 17, 25, and 33, and CSHPs at SEER 17, 25, and 33. Results show the increased adoption of high-efficiency heat pumps can result in up to 29% air conditioning energy savings for homes with window air conditioners.

42 ENGINEERING↗

Grant Proposal for the Continuation of the Voyager Interstellar Mission: LECP Investigation

This proposal documents the plans of the Low Energy Charged Particle (LECP) investigation team for participation in NASA's Voyager Interstellar Mission (VIM) as the Voyager 1 and 2 spacecraft explore the outer reaches of the heliosphere and search for the termination shock and the heliopause. The proposal covers the four year period from 1 January 1997 to 31 December 2000. The LECP instruments on Voyager 1 and 2 measure in situ intensities of charged particles with energies from about 30 keV to 100 MeV for ions, and about 20 keV to greater than 10 MeV for electrons. The instruments provide detailed spectral, angular, and compositional information about the particles. Composition is available for greater than 200 keV/nuc using multi-parameter measurements. Angular information is obtained by a mechanically scanned platform that rotates at various commanded rates. Measurements of low energy ion and electron intensities versus time and spatial location within the heliosphere contain an abundance of information regarding various transport and acceleration processes on both local (approx. 1 hr, approx. 0.01 AU) and global (approx. 11 yrs, approx. 100 AU) scales. The LECP instruments provide unique observations of such dynamical processes, and we anticipate that it will return critical information regarding the boundaries of the heliosphere. Several recent and exciting discoveries based on LECP measurements emphasize the important role that low energy charged particle distributions play in physical processes in the interplanetary medium. Yet, at the same time, these discoveries also underscore the fact that our understanding of processes in the outer heliosphere is, in most cases, incomplete, and in others, only rudimentary at best. Among the discoveries referred to above are the following: (1) Shocks: Examination of greater than 30 keV ion intensities have revealed: (a) a total absence of acceleration beyond only -100-200 keV at a strong transient shock in May 1991 at 35 AU, despite an enhanced level of seed particles; (b) a large transient shock in September 1991 of global scale, with intensities of shock-accelerated ions greater than or equal to 30 keV to approx. 30 MeV showing complex, highly energy-dependent spatial evolution, and small-scale (approx. few gyroradii), often anisotropic, micro-structures; (c) recurrent intensity increases in greater than or equal to 30 keV to -few MeV ions, with structures that, in some cases, show no correlation with the associated corotating shock. (2) Superthermal ion pressure: A global merged interaction region with a leading shock, downstream of which the superthermal ion (greater than or equal to 30 keV to approx. 4 MeV) pressure is comparable to that of the thermal plasma, and the total particle pressure yields a plasma beta of order unity. (3) Pickup ions: Measurements of the C/O ratio within transient structures at 35-45 AU showing the first clear evidence that transient shocks can pre-accelerate interstellar pickup ions from approx. 1 keV/nuc to at least 1 MeV/nuc. (4) Seed particles: Injection of ions for acceleration to high energies at the termination shock is unlikely to be a problem, since interplanetary transient and recurrent shocks are continually accelerating ions, of solar wind or interstellar origin, to highly superthermal energies. (5) Precursor electrons: Ambient solar electrons (greater than or equal to few tens of keV) that exist in the outer heliosphere ca form a broad precursor, several days wide, that is upstream of the termination shock and potentially observable a few months prior to the shock crossing. (6) Solar wind velocity at Voyager 1: We can use LECP ion data to obtain the solar wind velocity at Voyager 1, enabling us to provide critical measurement of the plasma flow as we approach and encounter the termination shock and other regions (necessary due to the partial failure of the Voyager 1 PLS experiment). The work of the LECP investigator team during the VIM will include: (1) Continuing operations with regard to the receipt, processing, verification, cataloging, display, and distribution of the data from the LECP instruments on Voyager 1 and 2, (2) Monitoring the health and performance of the LECP instruments, and evaluating and characterizing the response of the LECP instruments to various energetic particle and plasma environments, (3) Participating in, and supporting Voyager Project planning exercises and other coordinated activities relevant to exploration of the outer heliosphere, (4) Developing analysis techniques and operational procedures suitable for searching for and characterizing the boundaries and unique regions of the outher heliosphere, (5) Continuing the preparation of data sets appropriate for submission to the National Space Sciences Data Center (NSSDC) and, where appropriate, the Planetary Data System (PDS), (6) Maintaining direct Web access to online LECP data through the JHU/APL Voyager LECP home page, (7) Performing scientific evaluations of the Voyager 1 and 2 LECP data sets in conjunction with other data sets and other investigators, with particular focus on the outer regions of the heliosphere, and (8) Publishing the results of these evaluations in the scientific literature and presenting the results in scientific conferences.

Krimigis, Stamatios M.↗

Aerosol Envelope Sealing of Existing Residences

This report explores the best methods for aerosol envelope sealing of unoccupied, existing residences and documents typical leakage reductions. The project consisted of three distinct efforts: (1) scaled field demonstrations of the sealing process, tracking from setup to sealing and cleanup, (2) laboratory testing of new sealants that dry clear, making them more appropriate for retrofit applications, and (3) BEopt™ (Building Energy Optimization Tool) modeling of the energy implications of the measured reductions in leakage. Overall, aerosol sealing performance in existing homes was effective, with an average leakage reduction of 47% across all 34 sites. Conventional approaches typically only produce leakage reductions of 25%–30%. The aerosol sealing technology could provide a process for existing homes and multifamily units to gain the benefits of a well-sealed home at a reasonable cost with minimal disruption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Installer Badges Toolkit and Visualization Resources

NREL staff (Jal Desai and Cory Chovanec) will introduce the U.S. Department of Energy Weatherization Assistance Program (DOE WAP) Installer Badges Toolkit. The presentation will cover topics such as how this toolkit can be customized and implemented in a program, the potential benefits of using the Badges, and lessons learned from other implementers. This session will also engage participants to share their experiences regarding their existing training and how they are bringing their workforce up to speed in their building envelope-related programs. The Installer Badges Toolkit consists of 25 Badges, each representing different energy efficiency tasks that an installer could perform on a home. Each Badge defines the desired outcome, criteria to verify the work, applicable material requirements, and references to DOE's Standard Work Specifications (SWS) or other relevant standards. Workers earn Badges by completing each task and receiving approval from a qualified supervisor. The Badges provide a consistent approach to training by ensuring that installers are learning the same skills nationwide. Organizations can also customize the Toolkit by choosing only those Badges that are relevant to their program. NREL staff will also showcase new visualization resources like the Single-family and manufactured home job aids and the Single-family 3D house tool.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Measured Performance of Over the Range Microwave Range Hoods

The California residential building code requires kitchen exhaust ventilation to protect indoor air quality. The requirement can be met with a kitchen exhaust fan or a range hood that conforms to airflow and sound specifications based on certified, standard test results. Appliances that integrate an exhaust fan with an over the range microwave (OTRs) are popular for their space saving utility; but for years there were none with the certified performance data required for building code compliance. This project, initiated during that period, aimed to evaluate OTR models found in new California homes and compare their performance to range hoods that minimally met code requirements. The study aimed to expand on limited information available about OTR performance with a particular focus on measuring the fraction of cooktop-generated air pollutants that are captured and removed by the exhaust devices, a parameter called “capture efficiency”. Airflow and capture efficiency (CE) were measured in a simulated kitchen in Berkeley Lab’s FLEXLAB facility. Airflows were measured using several variations of a balanced-pressure flow method (Walker et al. 2001) including a protocol that had been used in the California Healthy Efficient New Gas Homes (HENGH) field study. Measurements were made for six OTRs observed in the field study, including three with certified test results (published after the start of this project) for airflow and sound. Measurements were also made on two standard range hoods with comparable airflows and costs to the OTRs, when accounting for the microwave functionality. CE was measured using the CO 2 emitted from burners while heating pots of water (POW) as a tracer and calculating the ratio of added CO 2 in the exhaust flow over the total CO 2 generated from burning fuel. Results show that OTRs generally met the California code requirements for airflow, which are the same as those of the residential ventilation standard of ASHRAE. It was determined that the field protocol used in HENGH study homes was biased low by ~14% on average. The CE performance of OTRs tested in this study were consistent with those tested under controlled conditions in prior studies, showing CE increasing with airflow and being higher for emissions occurring at the back cooktop burner(s) compared with front burner emissions. The measured CE covered a range of 40% to 85% for the front burners and 60% to 100% for the back burners. The relationship of CE to airflow for OTRs was within the range of those found for standard range hoods in this study and prior studies, with the key caveat that OTRs appear to have more consistent CE performance for emissions on the front burner.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effectiveness of supervised exercise, home-based exercise, or walk advice strategies on walking performance and muscle endurance in patients with intermittent claudication (SUNFIT trial): a randomized clinical trial

Abstract Aims Supervised exercise is a guideline-recommended treatment in intermittent claudication (IC). Hospital-based supervised exercise programmes (SEPs) are underutilized, while home-based structured exercise programmes (HSEPs) have attracted interest. The results from HSEP in IC are inconsistent and may confer no benefit over walk advice (WA) and be less effective than SEP. The aim of the study was to compare the effectiveness of best medical treatment, including Nordic pole WA alone, or WA + SEP or WA + HSEP for patients with IC. Methods and results This three-armed, multicentre randomized clinical trial enrolled patients with IC; all patients received best medical treatment including walking poles and the advice of regular Nordic pole walking (WA). For HSEP and SEP, additional exercise programmes were provided. The primarily investigated hypothesis was a non-inferiority analysis of SEP vs. HSEP regarding the 6-min walk test (6MWT) maximum distance, with a pre-defined non-inferiority margin of 50 m. Supporting outcomes included muscle endurance tests and the walking impairment questionnaire. Outcomes were assessed at baseline, 3, 6, and 12 months by a blinded evaluator. Altogether 166 patients (mean age 72 years; 59% males) were randomized. In HSEP and SEP, 24 and 26% patients, respectively, were fully exercise adherent. All three groups improved pain-free walking distance over time, but there were no significant intergroup differences. The intergroup 6MWT difference between SEP and HSEP from 0 to 12 months was –11.6 m, 95% confidence interval: –36.4 to 13.0 m (i.e. within the pre-specified non-inferiority margin). Conclusion The HSEP was non-inferior to SEP in patients with IC. There were no significant differences observed between the three groups at 1 year. Registration ClinicialTrials.gov: NCT02341716.

Sandberg, Anna (ORCID:0000000258432784)↗

Zero Energy Ready Out of the Box

In this conference paper for the ASHRAE Buildings XV conference, December 2022, PNNL staff share key metrics for companies who are combining off site construction with certification to the U.S. Department of Energy’s Zero Energy Ready Home program to create homes that are both cost effective to construct and high performance to live in. Key performance metrics and measures for modular, panelized, and SIP homes are compared against all homes in the DOE Zero Energy Ready Home program and against new homes built to code. These metrics show that off-site construction homes got similar or better energy performance to site-built homes, and in the case of modular and panelized, at considerably lower average cost than site-built homes. The paper also highlights the experiences of two DOE Zero Energy Ready Home builders who employ offsite construction methods. One builder constructs production homes using pre-assembled panels. The other builder designs and ships kit homes all over the United States. The paper will focus on the optimum value engineering aspects of the panelized construction processes used by each builder to identify management and production practices employed by the builders to operate profitably while meeting high energy performance goals, despite a year marked by skyrocketing materials costs and supply chain and labor shortages. Cost and labor savings methods will be discussed in the context of these two unique business models.

U.S. Department of Energy Building Technologies Pr↗

Draft Impacts: Modeling and Lab Validation (CRADA Final Report)

Chimney draft is a significant source of variability in real-world wood heater performance, yet laboratory tests conducted for certification do not capture this variability. Because draft varies with climate, chimney height, and home conditions, a heater that performs well in the lab can perform quite differently when installed in a home. Until now, wood heater manufacturers and installers have lacked the tools needed to anticipate how draft will vary across real installations or to advise on corrective measures when draft is too low or too high. The goal of this project was to develop and validate an open-source draft prediction tool for cordwood heater chimney systems. Over 18 months, Lawrence Berkeley National Laboratory (LBNL) and the Hearth, Patio & Barbecue Association (HPBA) collaborated to build a physics-based, Python tool that predicts how chimney draft evolves during operation, from ignition through steady burning. HPBA convened a stakeholder group of manufacturers and venting experts who provided feedback throughout development. LBNL validated the tool against laboratory measurements from a catalytic and a non-catalytic cordwood heater operated across a range of chimney heights and room-pressure conditions.

42 ENGINEERING↗

Transformative Efficiency and Automation in Modular Homes (TEAMH)

This report documents the Transformative Efficiency and Automation in Modular Homes (TEAMH) project, which evaluates the integration of advanced building envelope technologies and automation-assisted modular construction to improve residential energy performance and construction efficiency. The study investigates high-performance insulation systems, including vacuum insulation panels (VIPs), combined with light gauge steel (LGS) modular construction and factory automation. Laboratory testing, whole-building energy modeling across multiple climate zones, and factory demonstrations were conducted to assess thermal performance, energy savings, and production efficiency. Results indicate that upgraded envelope assemblies can achieve up to ~50% heating and ~34% cooling energy savings relative to IECC 2018 code-compliant homes, while automation-assisted construction can reduce wall assembly time by 24%–46% compared to conventional wood framing. The findings demonstrate the potential for scalable, high-performance modular homes that deliver significant energy savings with competitive projected costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aerosol-Based Method Seals the Deal for Tighter New Homes

What if an aerosol-based sealing method could tighten new home envelopes more quickly and effectively than traditional sealing methods? The method involves pressurizing an entire building while dispersing an aerosol sealant "fog" to the building interior. As air escapes the building through leaks in the envelope, sealant particles are carried to the leaks where they make contact and stick, sealing the leaks. A standard blower door and connected laptop facilitate the sealing process and provide real-time feedback and a permanent record of the sealing. The technology is thus capable of simultaneously measuring, locating, and automatically sealing leaks in a building. In fact, hundreds of linear feet of narrow leaks can be sealed simultaneously, reducing the time needed for manual inspection and sealing. To investigate the use of this method in new homes, the Center for Energy and Environment and partners worked with builders who performed the technique on 11 homes in California and 15 homes in Minnesota.

30 DIRECT ENERGY CONVERSION↗

Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes: Measured Data From Select Southeastern States

Little data is available that quantifies IAQ or associates contaminant levels with air exchange in U.S. homes. To address this gap, the U.S. Department of Energy (DOE) Building America Program conducted a study to characterize IAQ in U.S. homes constructed since 2013, along with presence, functionality, and occupant use of control measures. Specific objectives of this study effort included: Measuring time-integrated concentrations and temporal profiles of established contaminants of concern; monitoring the use of ventilation equipment; and tracking activities that impact air pollutant emissions and removal processes in typical homes in various climate zones; Characterizing the prevalence, type, and installed performance of mechanical ventilation equipment in new homes; exploring regional variations in system designs and performance; Investigating associations between contaminant levels and the presence of control measures including whole-house mechanical ventilation (WHMV). The study engaged research teams to collect data at a regional level. This report introduces the study protocol and presents and discusses high-level results obtained from Florida Solar Energy Center (FSEC) data collection efforts in the southeastern U.S. states of Florida, Georgia, and South Carolina.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-performance windows improve thermal survivability of occupants during cold snaps

Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.

Krelling, Amanda F↗