Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground

We present limits on spin-independent dark matter-nucleon interactions using a 10.6 g silicon athermal phonon detector with a baseline energy resolution of 4.92 +/- 0.01 eV. This exclusion analysis sets the most stringent dark matter-nucleon cross-section limits for masses from 87--140 MeV/c^2 , with a raw exposure of 9.9 g d acquired at an above-ground facility. This work illustrates the scientic potential of athermal phonon sensors with eV-scale energy resolution for future dark matter searches.

Alkhatib, I↗

Mesoscale Convective Systems Represented in High Resolution E3SMv2 and Impact of New Cloud and Convection Parameterizations

Mesoscale convective systems (MCSs) play an important role in modulating the global hydrological cycle, general circulation, and radiative energy budget. In this study, we evaluate MCS simulations in the second version of U.S. Department of Energy (DOE) Energy Exascale Earth System Model (E3SMv2). E3SMv2 atmosphere model (EAMv2) is run at the uniform 0.25? horizontal resolution. We track MCSs consistently in the model and observations using the PyFLEXTRKR algorithm, which defines MCS based on both cloud-top brightness temperature (Tb) and surface precipitation. Results from using Tb only to define MCS, commonly used in previous studies, are also discussed. Furthermore, sensitivity experiments are performed to examine the impact of new cloud and convection parameterizations developed for EAMv3 on simulated MCSs. Our results show that EAMv2 simulated MCS precipitation is largely underestimated in the tropics and contiguous United States. This is mainly attributed to the underestimated precipitation intensity in EAMv2. In contrast, the simulated MCS frequency becomes more comparable to observations if MCSs are defined only based on cloud-top Tb. The Tb-based MCS tracking method, however, includes many cloud systems with very weak precipitation which conflicts with the MCS definition. This result illustrates the importance of accounting for precipitation in evaluating simulated MCSs. We also find that the new physics parameterizations help increase the relative contribution of convective precipitation to total precipitation in the tropics, but the simulated MCS properties are generally not improved. This suggests that simulating MCSs will remain a challenge for the next version of E3SM.

Zhang, Meng↗

A Dual-Gated Structures for Lossless Ion Manipulations-Ion Mobility Orbitrap Mass Spectrometry Platform for Combined Ultra-High-Resolution Molecular Analysis

High-resolution ion mobility spectrometry-mass spectrometry (HR-IMS-MS) instruments have enormously advanced the ability to characterize complex biological mixtures. Unfortunately, HR-IMS and HR-MS measurements are typically performed independently due to mismatches in analysis time scales. Here we overcome this limitation by using a dual-gated ion injection approach to couple an 11-meter path length structures for lossless ion manipulations (SLIM) module to a Q-Exactive Plus Orbitrap MS. The dual-gate setup was implemented by placing one ion gate before the SLIM module and a second ion gate after. The dual-gated ion injection approach allowed the new SLIM-Orbitrap platform to simultaneously perform an 11-meter SLIM separation, Orbitrap mass analysis using the highest selectable mass resolution setting (up to 140k), and high-energy collision induced dissociation (HCD) in ~25 minutes over an $m/z$ range of ~1500 amu. The SLIM-Orbitrap was initially characterized using a mixture of standard phosphazene cations and demonstrated an average SLIM CCS resolving power (Rp CCS ) of ~218 and SLIM peak capacity of ~156 while simultaneously obtaining high mass resolutions. SLIM-Orbitrap analysis with fragmentation was then performed on mixtures of standard peptides and two reverse peptides (SDGRG 1+ , GRGDS 1+ , Rp CCS = 305) to demonstrate the utility of combined HR-IMS-MS/MS measurements for peptide identification. Our new HR-IMS-MS/MS capability was further demonstrated by analyzing a complex lipid mixture and showcasing SLIM separations on isobaric lipids. In conclusion, this new SLIM-Orbitrap platform demonstrates a critical new capability for proteomics and lipidomics applications, and the high-resolution multimodal data obtainable with this system establishes the foundation for reference-free identification of unknown ion structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular Layer Deposited Aluminum‐Based Hybrid Resist for High‐Resolution Nanolithography and Direct Ultra‐High Aspect Ratio Pattern Transfer

Inorganic-containing hybrid photoresists are critical for next-generation extreme ultraviolet (EUV) lithography and angstrom-era semiconductor miniaturization. However, associated conventional solution processing struggles to achieve ultrathin, uniform films with high conformality and compositional control, limiting overall patterning performance. Here, this study reports the systematic lithographic patterning characterization of an Al-based hybrid resist synthesized via vapor-phase molecular layer deposition (MLD), using the trimethylaluminum (TMA) metal precursor and the hydroquinone (HQ) aromatic organic linker. The resist supports both sub-20 nm high-resolution nanolithography and virtually infinite silicon plasma etch selectivity. Lithographic performance studied using electron beam lithography (EBL) as a proxy for EUV shows that, under an optimized process adopting post-exposure bake, the resist achieves the best resolution of 15.4 nm linewidth under stringent 1:1 line-space high-density patterning—limited only by the minimum beam size of the EBL system. The resist also shows wide dose latitude and balanced performance in resolution, roughness, and sensitivity. The infinite silicon etch selectivity, stemming from spontaneous aluminum oxyfluoride passivation layer formation, enables fabrication of micrometer-tall, 40 nm-wide silicon nanofin structures using only a ≈30 nm-thick resist layer, without no hard mask. These results highlight the potential of MLD-based hybrid resists for developing next-generation resist materials for micro/nanoelectronics manufacturing.

36 MATERIALS SCIENCE↗

High-dimensional and high-resolution x-ray tomography for energy materials science

At the forefront of developments in synchrotron x-ray microscopy, we report nanoscale-resolution high-dimensional spectrotomography under controlled sample environments has been demonstrated. Such cutting-edge experimental capability has been broadly applied to scientific studies in the field of energy materials science, where the dynamically evolving structural and chemical defects play a vital role in the functionality. In this article, we review novel developments of this technique from both experimental and data/information mining perspectives. Using studies on lithium-ion battery electrode materials as examples, we highlight the rich information in the high-dimensional and high-resolution x-ray tomographic data, which can be used to interpret the complicated thermal-electro-chemo-mechanical interplay that occurs under the operating conditions and collectively determines battery performance. We also discuss the frontier challenges in this field and our perspectives of the future directions in the context of projected major developments in the landscape of largescale x-ray facilities across the globe.

36 MATERIALS SCIENCE↗

Deep learning-driven super-resolution in Raman hyperspectral imaging: Efficient high-resolution reconstruction from low-resolution data

Deep learning (DL) has become an indispensable tool in hyperspectral data analysis, automatically extracting valuable features from complex, high-dimensional datasets. Super-resolution reconstruction, an essential aspect of hyperspectral data, involves enhancing spatial resolution, particularly relevant to low-resolution hyperspectral data. Yet, the pursuit of super-resolution in hyperspectral analysis is fraught with challenges, including acquiring ground truth high-resolution data for training, generalization, and scalability. The pressing issue of extended spectral acquisition times, notably for high-resolution scans, is a significant roadblock in hyperspectral imaging. Super-resolution methods offer a promising solution by providing higher spatial resolution data to expedite data collection and yield more efficient outcomes. This paper delves into a practical application of these concepts using Raman imaging, where spectral acquisition times can be prohibitively long. In this context, DL-based super-resolution models demonstrate their efficacy by predicting and reconstructing high-resolution Raman data from low-resolution input, eliminating the need for resource-intensive high-resolution scans. While previous work often relied on substantial high-resolution datasets, this study showcases the ability to achieve similar outcomes even with limited data, presenting a more practical and cost-effective approach. In conclusion, the results offer a glimpse into the transformative potential of this technology to streamline hyperspectral imaging applications by saving valuable time and resources through the successful generation of high-resolution data from low-resolution inputs.

42 ENGINEERING↗

Commission < 5 µm spatial resolution x-ray imager for High Resolution Turbulence experiments

This report presents the successful development, commissioning, and deployment of the Scintillation-Based X-ray Imager (SBXI) for the High-Resolution Turbulence (HRT) campaign at the National Ignition Facility (NIF). The SBXI system was designed to overcome the spatial resolution and efficiency limitations of conventional x-ray imaging detectors. Through careful system engineering, rigorous laboratory characterization, and experimental validation at NIF, the SBXI has demonstrated spatial resolution at the object plane of 5 μm (±0.5 μm) and a detective quantum efficiency (DQE) of 34% at 7.2 keV, both of which surpass the requirements set by the campaign, and meeting the L2 milestone. The system’s deployment enables high-fidelity imaging of fine-scale hydrodynamic instabilities, directly supporting advanced turbulence model validation and future high energy density physics research.

42 ENGINEERING↗

XRISM high-resolution X-ray spectroscopy of Cygnus X-1: Highly ionized iron absorption structures

We present the first high-resolution X-ray spectral analysis of Cygnus X-1 using XRISM. The observation wa3s carried out from 2024 April 7 to 10, covering the orbital phase range 0.65–0.17 during its low/hard state. Taking advantage of the exceptional energy resolution of the Resolve instrument, we examined highly ionized iron absorption lines and characterized the ionization states, column densities, and line-of-sight velocities of the absorbing plasma. Spectral analysis revealed an ionization parameter of $\xi \sim 3$, column densities of a few $\times 10^{21}$ cm$^{-2}$, and a blueshifted velocity of $\sim$100 km s$^{-1}$. The observation was divided into two phases: before and after orbital phase $\phi _{\rm {orb}} = 0.9$, corresponding to non-dipping and dipping intervals. While only weak absorption features were present before $\phi _{\rm {orb}} = 0.9$, strong absorption by He-like and H-like Fe appeared during the dipping phase. We measured equivalent widths of 2.3, 0.4, and 1.2 eV for He-like Fe K$\alpha$ and H-like Ly$\alpha _1$ and Ly$\alpha _2$, respectively—demonstrating the capability of XRISM Resolve to securely detect narrow absorption features of only a few eV. These measurements trace the motion of the absorbing material and offer insight into the kinematics and spatial distribution of the wind in the vicinity of the black hole. These findings enhance our understanding of wind-fed accretion in Cygnus X-1 and highlight the importance of continued high-resolution X-ray observations to further constrain the physical properties of winds and accretion flows in high-mass X-ray binaries.

Astronomy and AstroPhysics↗

Cryo-EM sample preparation for high-resolution structure studies

High-resolution structures of biomolecules can be obtained using single-particle cryo-electron microscopy (SPA cryo-EM), and the rapidly growing number of structures solved by this method is encouraging more researchers to utilize this technique. As with other structural biology methods, sample preparation for an SPA cryo-EM data collection requires some expertise and an understanding of the strengths and limitations of the technique in order to make sensible decisions in the sample-preparation process. Here, in this article, common strategies and pitfalls are described and practical advice is given to increase the chances of success when starting an SPA cryo-EM project.

36 MATERIALS SCIENCE↗