Optical properties of thermal control coating contaminated by MMH/N2O4 5-pound thruster in a vacuum environment with solar simulation

Cat-a-lac Black, and S13G thermal control coatings were exposed to the exhaust of a thruster in a simulated space environment. Vacuum was maintained at less than 10 to the minus 5th power torr during thruster firing in the liquid helium cooled facility. The thruster was fired in a 50-millisecond pulse mode and the accumulated firing time was 224 seconds. Solar absorptance (alpha sub s) and thermal emittance (sigma) of the coatings were measured in-situ at intervals of 300 pulses. A calorimetric technique was used to measure alpha sub s and sigma. The tests, technique, and test results are presented. The Cat-a-lac Black coatings showed no change in alpha sub s or sigma. The S13G showed up to 25 percent increase in alpha sub s but no change in sigma.

Sommers, R. D.↗

Optical properties of thermal control coatings contaminated by MMH/N2O4 5-pound thruster in a vacuum environment with solar simulation.

Cat-a-lac Black and S13G thermal control coatings were exposed to the exhaust of a thrustor in a simulated space environment. Vacuum was maintained at less than 10 microtorr during thrustor firing in the liquid helium cooled facility. The thrustor was fired in a 50-millisecond pulse mode, and the accumulated firing time was 224 seconds. Solar absorptance and thermal emittance of the coatings were measured in-situ at intervals of 300 pulses, using a calorimetric technique. The Cat-a-lac Black coatings showed no change in solar absorptance or thermal emittance. The S13G showed up to 25% increase in solar absorptance but no change in thermal emittance.

Sommers, R. D.↗

A study of density measurements in hypersonic helium tunnels using an electron beam fluorescence technique

A series of experiments have been conducted at Langley Research Center to determine the feasibility of using electron-beam fluorescence to measure the free-stream static density of gaseous helium flow over a wide range of conditions. These experiments were conducted in the Langley hypersonic helium tunnel facility and its 3-inch prototype. Measurements were made for a range of stagnation pressures and temperatures and produced free-stream number densities of 1.53 x 10 to the 23rd to 1.25 x 10 to the 24th molecules/cu m and static temperatures from 2 K to 80 K. The results showed the collision quenching cross section to be 4.4 x 10 to the -15th sq cm at 1 K and to have a weak temperature dependence of T to the 1/6. With knowledge of these two values, the free-stream number density can be measured quite accurately.

Honaker, W. C.↗

Exploratory investigation of the aerodynamic characteristics of a biwing vehicle at Mach 20.3

Longitudinal and lateral-directional characteristics of a simple biwing configuration were determined over an angle-of-attack range from -3 deg to 50 deg. The body was comprised of a cylindrical section with an ogival forebody having an overall fineness ratio of 6.67. The delta wings had a 38.3 deg sweep angle and were geometrically similar in planform. The upper wing was located slightly forward relative to the lower wing. The model was tested in upright and inverted orientations including component buildups. This investigation was conducted in the 22-inch aerodynamics leg of the Langley Hypersonic Helium Tunnel Facility.

Bernot, P. T.↗

Hypersonic characteristics of an advanced aerospace plane at Mach 20.3

Wind-tunnel studies have been performed in the Langley Hypersonic Helium Tunnel Facility to obtain static longitudinal and lateral-directional aerodynamic characteristics of an advanced aerospace plane concept. The nominal test conditions are a Mach number of 20.3 and a Reynolds number of 6.8 x 10 to the 6th power per foot at angles of attack from 0 to 25 deg and angles of sideslip of -3 and 0 deg. Stability and control characteristics are obtained for several deflections of the elevators, elevons, and rudder. In addition, a modified canopy is examined. The results indicate that this vehicle is longitudinally stable at angles of attack near the maximum lift-drag ratio. Also, the vehicle is shown to be directionally unstable with positive dihedral effect.

Mccandless, R. S.↗

Ames Research Center cryogenics program

Viewgraphs describe the Ames Research Center's cryogenics program. Diagrams are given of a fluid management system, a centrifugal pump, a flow meter, a liquid helium test facility, an extra-vehicular activity coupler concept, a dewar support with passive orbital disconnect, a pulse tube refrigerator, a dilution refrigerator, and an adiabatic demagnetization cooler.

Kittel, Peter↗

Pressure drop in the SHOOT superfluid helium acquisition system

Central to the upcoming Superfield Helium On-Orbit Transfer (SHOOT) demonstration is the fluid acquisition system. The main component of the system is a rectangular cross-section gallery area with one side fabricated from a fine mesh screen. He II enters through the screen and is delivered to a fountain effect pump. A model is proposed to predict the pressure drop as fluid flows through the screen and an expression is derived for the required gallery arm length as a function of flow rate demand. The model is compared with measurement of pressure drop in a full scale SHOOT gallery arm operated with flow rates of up to 850 cu dm/hr. The tests were conducted in the University of Wisconsin horizontal liquid helium flow facility to minimize gravitational effects.

Nissen, J. A.↗

Recent aerodynamic measurements with Magnetic Suspension Systems

This paper reviews recent aerodynamic tests of a family of slanted-base ogive-cylinders using the NASA Langley 13-inch Magnetic Suspension and Balance System. Results include drag, lift, pitching moment, support interference and base pressure measurements. Mach numbers were in the range 0.04 to 0.2. Drag results are shown to be in satisfactory agreement with previous measurements. Significant support interferences were found at all test conditions. Comparison is made between interference free base pressures, obtained using remote telemetry, and sting cavity pressures. Test results and procedures are briefly discussed in the context of the proposed helium flow facility.

Britcher, Colin P.↗

Experimental investigations of He II flows at high Reynolds number

Fluid dynamics studies of He II at high Reynolds number (Re(d) greater than 10 exp 6) reveal characteristics which are best interpreted in terms of classical scaling relationships. In particular, the smooth tube friction factor is seen to correlate with the Von Karman-Nikuradse formulation. Also, the performance of a centrifugal pump is unchanged whether being used with He I or He II. These effects are expected to result provided the He II possesses a viscous sublayer and that the drag is determined by laminar flow within this layer. On the other hand, heat transfer in He II is substantially different from that of He I because of the unique internal convection mechanism present in this quantum fluid. These experiments are performed in the University of Wisconsin liquid helium flow facility which has unique capabilities of He II temperature, pressure and flow.

Van Sciver, Steve W.↗

Inductance studies for the Quench Protection system of the Mu2e TS solenoids

This is a preliminary study on the solenoids for the Mu2e experiment. An overview of the Mu2e solenoids is first provided. Then the two solenoid prototypes were tested in the Fermilab Central Helium Liquefying facility. My analysis is focused on measuring and modeling the inductance (self and mutual) of the magnets. This aspect is crucial for Quench Detection Systems and for the control parameters of the power supply driving the magnets. During the first part of my experience at Fermilab, I worked on mathematical mod- els for the magnets to understand their expected behavior. A geometric model based on the Neumann formula was developed and implemented for inductance calculations. This model estimates the inductance (self and mu- tual) of all the Mu2e solenoids. A finite element magnetic model for the two prototype magnets was developed to compare to the results of the geometric model. In the second part of my study I collected measurements on the real Transport Solenoid prototypes. T he solenoids were powered in different configurations in order to identify the circuit model and its parameters. These experiments were first carried on the warm magnets and then on the magnets at a cryo- genic temperature. This allows for a comparison between room temperature and superconducting state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of the High Temperature Test Facility PG-26 Transient Using RELAP-7

The High Temperature Test Facility (HTTF) is an electrically heated, helium cooled, experimental facility located at Oregon State University (OSU). Modeling of the HTTF PG-26 transient using a multi-app approach utilizing MOOSE and RELAP-7 was conducted. A 3-D model of the HTTF core, reflector, core barrel, and RPV was generated, and 3-D heat conduction throughout the structure was coupled to 1-D fluid flow results from RELAP-7. The model was able to accurately predict peak ceramic core temperatures experienced during the transient which helps validate the capability of RELAP-7 to model advanced gas-cooled nuclear reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

IB3A Helium Recovery System

An evaluation of the Fermilab's helium cryogenics test facilities has identified a pressing need for a helium recovery system in the Technical Division's Industrial Building 3a (IB3A). The IB3A facility, which plays a crucial role in testing components for various research projects, including the High-Luminosity LHC Accelerator Upgrade and Mu2e, currently vents helium into the air. Implementing recovery practices is essential due to helium's non-renewable nature and the goal of sustaining the Fermilab's scientific operations long-term. This poster covers benefits helium recovery for Fermilab and highlights the most important aspects of current helium recovery effort.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Superfluid helium on orbit transfer (SHOOT)

A number of space flight experiments and entire facilities require superfluid helium as a coolant. Among these are the Space Infrared Telescope Facility (SIRTF), the Large Deployable Reflector (LDR), the Advanced X-ray Astrophysics Facility (AXAF), the Particle Astrophysics Magnet Facility (PAMF or Astromag), and perhaps even a future Hubble Space Telescope (HST) instrument. Because these systems are required to have long operational lifetimes, a means to replenish the liquid helium, which is exhausted in the cooling process, is required. The most efficient method of replenishment is to refill the helium dewars on orbit with superfluid helium (liquid helium below 2.17 Kelvin). To develop and prove the technology required for this liquid helium refill, a program of ground and flight testing was begun. The flight demonstration is baselined as a two flight program. The first, described in this paper, will prove the concepts involved at both the component and system level. The second flight will demonstrate active astronaut involvement and semi-automated operation. The current target date for the first launch is early 1991.

Dipirro, Michael J.↗

Heating rate measurements over 30 deg and 40 deg (half angle) blunt cones in air and helium in the Langley expansion tube facility

Convective heat transfer measurements, made on the conical portion of spherically blunted cones (30 deg and 40 deg half angle) in an expansion tube are discussed. The test gases used were helium and air; flow velocities were about 6.8 km/sec for helium and about 5.1 km/sec for air. The measured heating rates are compared with calculated results using a viscous shock layer computer code. For air, various techniques to determine flow velocity yielded identical results, but for helium, the flow velocity varied by as much as eight percent depending on which technique was used. The measured heating rates are in satisfactory agreement with calculation for helium, assuming the lower flow velocity, the measurements are significantly greater than theory and the discrepancy increased with increasing distance along the cone.

Reddy, N. M.↗

Providing Experimental Infrastructure for Accelerating Advanced Reactor Demonstrations through the National Reactor Innovation Center

A suite of experimental infrastructure projects has been developed by the National Reactor Innovation Center to accelerate advanced reactor demonstrations and facilitate their development, addressing crucial gaps in data, materials characterization, and modeling. First, the Molten Salt Thermophysical Examination Capability (MSTEC) provides a specialized platform for post-irradiation characterization of molten salt reactor fuel, coolant salts, and structural materials, essential for supporting the design and operation of advanced reactors and future commercial molten salt reactor development and licensing. The Virtual Test Bed (VTB) complements these efforts by leveraging advanced modeling and simulation tools to evaluate reactor performance and safety. Serving as a library of reference models, the VTB offers a database of multiphysics reactor models, facilitating rapid safety evaluations and includes continuous software quality assurance, crucial for accelerating deployment while maintaining reliability. Additionally, the Helium Component Test Facility (HeCTF) addresses the need for high-temperature helium-cooled reactor component testing. As the first-of-its-kind facility in the United States, HeCTF emulates high-temperature gas reactor conditions, reducing time and cost associated with component validation, thereby accelerating reactor development. Finally, In-cell Thermal Creep Frames provide a unique solution for obtaining thermal creep data from irradiated materials, critical for materials qualification and licensing. Developed by the National Reactor Innovation Center, these compact frames enable the examination of previously irradiated materials, overcoming traditional limitations and enhancing the understanding of mechanical properties crucial for reactor development. Collectively, these experimental infrastructure projects form a comprehensive framework aimed at expediting advanced reactor demonstrations, fostering innovation, and ensuring the viability of next-generation nuclear energy solutions.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling of the High Temperature Test Facility Using RELAP-7

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is an electrically heated, helium cooled, experimental facility. The HTTF was modeled using RELAP-7 in both 1-D and 3-D for validation. Due to core symmetry, 1/6th of the HTTF core was modeled in 3-D using the coupled heat conduction and forced convection capabilities of RELAP-7. This served as a validation case for RELAP-7 and its capabilities to model advanced nuclear technologies such as high temperature gas-cooled reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗