Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “helicon source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Ion source development for various applications in Korea (invited) (abstract)

Ion source development in Korea has been related with various applications from accelerator to nanotechnology. Conventional ion sources such as Duoplasmatron and PIG ion sources were developed for high power proton accelerator and small cyclotron accelerators. To improve lifetime of the high current proton ion source, helicon plasma ion sources were developed with external rf antenna and applied for neutron generation in drive-in-target configuration. Negative hydrogen ion sources were also developed for tandem and cyclotron accelerators by using both rf and filament discharges. Large-area high-current ion sources for the KSTAR NBI system were developed and successfully tested for long-pulse operation of up to 300 s. Several broad beam ion sources for industrial applications such as ion implantation and surface treatment were also developed by using arc, rf, and microwave discharges. Recently, ion source applications become diversified to the area of nano- and biotechnologies. For example, C60 ion source was developed for the use of bioapplications in nanometer scale. For focused ion beam as a nanofabrication tool, liquid metal ion sources were improved and a novel plasma ion source was developed by utilizing localized sheath discharges. Research and development activities of these ion sources will be discussed with short description of appropriate applications.

43 PARTICLE ACCELERATORS↗

Direct measurements of classical and enhanced gradient-aligned cross-field ion flows in a helicon plasma source using laser-induced fluorescence

Direct laser induced fluorescence measurements are shown of cross-field ion flows normal to an absorbing boundary that is aligned parallel to the axial magnetic field in a helicon plasma. We show Langmuir and emissive probe measurements of local density and plasma potential in the same region, as well as floating probe spectra near the boundary. With these measurements, we investigate the influence of ion-neutral collisionality on radial ion transport by varying the ratio of the ion gyro-radius, ρ{sub i}, to the ion-neutral collision length, λ, over the range 0.34 ≤ ρ{sub i}λ{sup −1} ≤ 1.60. Classical drift-diffusion transport along density and potential gradients is sufficient to describe flow profiles for most cases. For two parameter regimes (ρ{sub i}λ{sup −1} = 0.65 and 0.44), low-frequency electrostatic fluctuations (f < 10 kHz) and enhanced cross-field bulk ion flow to the boundary are observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Negative hydrogen ion production in a helicon plasma source

In order to develop very high energy (>1 MeV) neutral beam injection systems for applications, such as plasma heating in fusion devices, it is necessary first to develop high throughput negative ion sources. For the ITER reference source, this will be realised using caesiated inductively coupled plasma devices, containing either hydrogen or deuterium discharges, operated with high rf input powers (up to 90 kW per driver). It has been suggested that due to their high power coupling efficiency, helicon devices may be able to reduce power requirements and potentially obviate the need for caesiation due to the high plasma densities achievable. Here, we present measurements of negative ion densities in a hydrogen discharge produced by a helicon device, with externally applied DC magnetic fields ranging from 0 to 8.5 mT at 5 and 10 mTorr fill pressures. These measurements were taken in the magnetised plasma interaction experiment at the Australian National University and were performed using the probe-based laser photodetachment technique, modified for the use in the afterglow of the plasma discharge. A peak in the electron density is observed at ∼3 mT and is correlated with changes in the rf power transfer efficiency. With increasing magnetic field, an increase in the negative ion fraction from 0.04 to 0.10 and negative ion densities from 8 × 10{sup 14 }m{sup −3} to 7 × 10{sup 15 }m{sup −3} is observed. It is also shown that the negative ion densities can be increased by a factor of 8 with the application of an external DC magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

rf power system for thrust measurements of a helicon plasma source

A rf power system has been developed, which allows the use of rf plasma devices in an electric propulsion test facility without excessive noise pollution in thruster diagnostics. Of particular importance are thrust stand measurements, which were previously impossible due to noise. Three major changes were made to the rf power system: first, the cable connection was changed from a balanced transmission line to an unbalanced coaxial line. Second, the rf power cabinet was placed remotely in order to reduce vibration-induced noise in the thrust stand. Finally, a relationship between transmission line length and rf was developed, which allows good transmission of rf power from the matching network to the helicon antenna. The modified system was tested on a thrust measurement stand and showed that rf power has no statistically significant contribution to the thrust stand measurement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of a Light Gas Helicon Plasma Source for the VASIMR Space Propulsion System

An efficient plasma source producing a high-density (approx.10(exp 19/cu m) light gas (e.g. H, D, or He) flowing plasma with a high degree of ionization is a critical component of the Variable Specific Impulse Magnetoplasma Rocket (VASIMR) concept. We are developing an antenna to apply ICRF power near the fundamental ion cyclotron resonance to further accelerate the plasma ions to velocities appropriate for space propulsion applications. The high degree of ionization and a low vacuum background pressure are important to eliminate the problem of radial losses due to charge exchange. We have performed parametric (e.g. gas flow, power (0.5 - 3 kW), magnetic field , frequency (25 and 50 MHz)) studies of a helicon operating with gas (H2 D2, He, N2 and Ar) injected at one end with a high magnetic mirror downstream of the antenna. We have explored operation with a cusp and a mirror field upstream. Plasma flows into a low background vacuum (<10(exp -4) torr) at velocities higher than the ion sound speed. High densities (approx. 10(exp 19/cu m) have been achieved at the location where ICRF will be applied, just downstream of the magnetic mirror.

Squire, J. P.↗

Development of a Direct Neutral Density Diagnostic for Fusion Edge Plasmas

As magnetically confined plasmas progress towards ignition and long pulse experiments, measurement and control of the neutral density in the plasma edge has become a critical issue for stability, formation of transport barriers, and fueling. Recent experiments by our research group have demonstrated that is possible to use two-photon absorption laser induced fluorescence (TA-LIF) to directly measure the density of neutral hydrogen in helicon sources and in the HIT-SI3 spheromak. While those experiments validated key elements of a diagnostic system that would enable similar measurements in tokamak plasmas, they did not fully address the issue of performance optimization in the presence of intense background light at the fluorescence wavelength and they also identified a number of other issues that must be resolved before successful TALIF neutral density measurements in a tokamak are likely to be achieved. Additional specific concerns raised during design reviews with the leadership of the DIII-D tokamak facility included: the minimum detection threshold for this TALIF diagnostic (currently ~ 5 x 10 15 m -3 ) and the rate at which neutral density measurements could be obtained. Improving the system performance to reduce the minimum detection threshold and demonstrating a faster rate of density determination are required to advance this diagnostic to the level where it could be considered for implementation on a major tokamak facility in the USA. The key issues that will be addressed through additional technological development are: validation of a new, chromatic aberration-free, xenon calibration scheme; increasing the output power of the laser; and suppression of background emission at the fluorescence wavelength through optimization of the collection optics and gating of the photomultiplier detector with a goal of obtaining a minimum detection threshold of 5 x 10 14 m -3 . Another key technological development, so far only tested in helicon source experiments, is the validation of Doppler-free TALIF as a means of obtaining higher speed, calibrated, neutral density measurements in tokamak-like conditions at the full cadence of the pulsed TALIF laser. In this work, we propose to complete these technological advancements through installation and testing of our prototype TALIF system on the proto-MPEX experiment at Oak Ridge National Laboratory (ORNL). The proto-MPEX facility will provide plasma conditions similar to the edge plasma of a major tokamak experiment but with pulse lengths and pulse repetition rates ideally suited for extensive development of a TALIF neutral density diagnostic. Measurement of the absolute neutral density in the edge of a magnetically confined plasma is necessary for plasma density control; calculation of charge-exchange power losses; control of plasma-wall interactions; determination of the braking of plasma flow; determination of the fuel mixture in deuterium-tritium plasma; and understanding the dynamics of the divertor region in the plasma edge. In terms of potential impact on the worldwide fusion program, we note that in burning plasma experiments, such as ITER, a 100 mJ/pulse Doppler-free TALIF diagnostic should be capable of directly measuring the deuterium/tritium (D/T) isotope ratio in the outer 0.5 to 1.0 m of the plasma radius. The D/T ratio is a critically important parameter for the control and optimization of burning plasmas. Therefore, development of the diagnostic system proposed here is also relevant to long-term US participation in diagnostic development for large tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evidence for electron energization accompanying spontaneous formation of ion acceleration regions in expanding plasmas

We report experiments conducted in an expanding argon plasma generated in the inductive mode of a helicon source in the Hot hELIcon eXperiment–Large Experiment on Instabilities and Anisotropies facility. As the neutral gas pressure increases, the supersonic ion acceleration weakens. Increasing neutral pressure also alters the radial profile of electron temperature, density, and plasma potential upstream of the plasma expansion region. Langmuir probe measurements of the electron energy probability function (EEPF) show that heating of electrons at the plasma edge by RF fields diminishes with increasing gas pressure, yielding a plasma with a centrally peaked electron temperature, and flat potential profiles at higher neutral pressures. For neutral pressures at which ion acceleration regions develop in the expanding plasma plume, EEPFs reveal electrons with two temperature components.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physics-electrical hybrid model for real time impedance matching and remote plasma characterization in RF plasma sources

Plasma characterization and impedance matching are an integral part of any radio frequency (RF) based plasma source. In long pulse operation, particularly in high power operation where plasma load may vary due to different reasons (e.g. pressure and power), online tuning of impedance matching circuit and remote plasma density estimation are very useful. In some cases, due to remote interfaces, radio activation and, due to maintenance issues, power probes are not allowed to be incorporated in the ion source design for plasma characterization. Therefore, for characterization and impedance matching, more remote schemes are envisaged. Two such schemes by the same authors are suggested in these regards, which are based on air core transformer model of inductive coupled plasma (ICP) [M. Bandyopadhyay et al., Nucl. Fusion 55, 033017 (2015); D. Sudhir et al., Rev. Sci. Instrum. 85, 013510 (2014)]. However, the influence of the RF field interaction with the plasma to determine its impedance, a physics code HELIC [D. Arnush, Phys. Plasmas 7, 3042 (2000)] is coupled with the transformer model. This model can be useful for both types of RF sources, i.e., ICP and helicon sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of an Actively Cooled Window for High Power Helicon Plasma Source

The development of the next generation of magnetically confined fusion facilities towards commercial fusion power will depend on an increased understanding of plasma material interactions (PMI). Plasma facing components in future facilities such as a Fusion Nuclear Science Facility (FSNF) or DEMO will experience high heat fluxes, high energy neutron fluence, and helium and hydrogen isotope permeation. This combination of environmental effects is unique to the fusion environment, and research and development in the field of PMI will require integrated facilities that can provide prototypical conditions. Particularly, facilities are required that will simulate conditions in the first wall and divertor regions. One such proposed facility is Materials Plasma Exposure experiment (MPEX). (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Material Plasma Exposure eXperiment: Mission and conceptual design

Mastering Plasma Material Interactions (PMI) is key for obtaining a high performance, high duty-cycle and safe operating fusion reactor. Numerous gaps exist in PMI which have to be addressed before a reactor can be built. In particular the lack of data at high ion fluence, fusion reactor divertor relevant plasma conditions and neutron displacement damage requires new experimental devices to be able to develop plasma facing materials and components. This has been recognized in the community and the U.S. fusion program is addressing this need with a new linear plasma device—the Material Plasma Exposure eXperiment (MPEX). MPEX will be a superconducting linear plasma device with magnetic fields of up to 2.5 T. The plasma source is a high-power helicon source (200 kW, 13.56 MHz). The electrons will be heated via Electron Bernstein Waves with microwaves using multiple 70 GHz gyrotrons (up to 600 kW in total). Ions will be heated via ion cyclotron heating in the so-called “magnetic beach heating” scheme in the frequency range of 6–9 MHz (up to 400 kW in total). An overview of the conceptual design and the project/design requirements is given in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Helicon normal modes in Proto-MPEX

Here, the Proto-MPEX helicon source has been operating in a high electron density 'helicon-mode'. Establishing plasma densities and magnetic field strengths under the antenna that allow for the formation of normal modes of the fast-wave are believed to be responsible for the 'helicon-mode'. A 2D finite-element full-wave model of the helicon antenna on Proto-MPEX is used to identify the fast-wave normal modes responsible for the steady-state electron density profile produced by the source. We also show through the simulation that in the regions of operation in which core power deposition is maximum the slow-wave does not deposit significant power besides directly under the antenna. In the case of a simulation where a normal mode is not excited significant edge power is deposited in the mirror region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysing the effects of heating and gas puffing in Proto-MPEX helicon and auxiliary heated plasmas

The Material Plasma Exposure Experiment (MPEX) is being constructed at Oak Ridge National Laboratory to investigate critical fusion reactor issues, such as plasma–material interactions (PMIs) under reactor-relevant conditions and time scales. The linear device Proto-MPEX was used as a test bed to address anticipated research and development issues associated with heating scenarios and establish the physics basis for MPEX. The SOLPS-ITER code suite has been applied to understand plasma and neutral transport in Proto-MPEX and to increase confidence in predictive simulations for MPEX. Coupling between COMSOL and SOLPS is performed to implement a 2D electron heating profile of the helicon source. The simulations show reasonable agreement with the experimental data for plasma with helicon and auxiliary electron cyclotron heating (ECH). Both Bohm and constant diffusion (D$_\perp$: 0.5 m 2 s –1 and $\chi_\perp$: 1 m 2 s –1 ) simulations show similar levels of agreement with respect to the sparse experimental data available, assuming a few per cent impurity concentration. ECH significantly increases the target electron temperature, however, the target electron density is reduced compared to helicon-only heated plasmas due to an increase in flow velocity and radial losses. The simulations show that further increasing the ECH power results in an increase in the target electron density due to increased recycling flux and ionization. The results indicate that ECH significantly enhances the target heat flux, with ECH power of 50 kW increasing the target heat flux from 0.4 to 17 MW m –2 . It is found that a small amount of gas puffing (GP) near the target plate can further increase the target heat fluxes at the higher ECH power cases, but the target heat flux is reduced at higher GP conditions due to a significant reduction in electron temperature via radiation. ECH and GP scenarios can generate a higher target flux, facilitating improved PMI studies with more reactor-relevant plasma conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coherent mode and turbulence measurements with a fast camera

This study employs a fast camera with frame rates up to 900,000 fps to measure the transfer of energy across spatial scales in helicon source plasmas and during flux rope mergers and the measurement of azimuthal mode structures in helicon plasmas. By extracting pixel-scale dispersion relations and power spectral density (PSD) measurements, we measure the details of turbulent wave modes and energy distribution across a broad range of spatial scales within the plasma. We confirm the presence of drift waves in helicon plasmas, as well as the existence of strong dissipation regions in the PSD at electron skin depth scales for both helicon and flux rope merger experiments. This approach overcomes many limitations of conventional probes, providing high spatial and temporal resolution, without perturbing the plasma.

Instruments & Instrumentation↗

Latest Results from Proto-MPEX and the Future Plans for MPEX

The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is being used to qualify the plasma source and heating systems for the Material Plasma Exposure eXperiment (MPEX). The MPEX will address important and urgent research needs on plasma material interactions for future fusion reactors. In MPEX, plasma-facing components (nonirradiated and a priori neutron irradiated) will be exposed to plasma conditions as they are expected in future fusion reactors. The MPEX, a steady-state device enabled by superconducting magnets, will be able to break into new ground by assessing plasma-facing materials and components at an ion fluence level in the range of 10 30 to 10 31 m -2 . To achieve the relevant plasma conditions, high-density plasmas (>4 × 10 19 m -3 ) are produced with a high-power helicon source. The so-produced low-temperature helicon plasma is then additionally heated with waves in the ion cyclotron resonance frequency and electron cyclotron resonance frequency domains. Proto-MPEX has achieved all key parameters (source n e , source T e , source T i , target T e , target T i , target ion flux, and target heat flux) within a factor of 2 of the design requirements of MPEX, albeit not simultaneously. These parameters were achieved with a total installed heating power of 330 kW, which is less than half of the planned heating power in the MPEX (800 kW). An overview of the latest results from Proto-MPEX is given. These results are shown in relationship to the MPEX system goals. Remaining necessary research and development tasks are discussed. The MPEX is currently in the conceptual design phase. Lastly, the status of the design and an overview of the system requirements are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operational domain of Proto-MPEX

The Prototype-Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device to test the plasma source concepts for the future Material Plasma Exposure eXperiment (MPEX). MPEX is planned to address plasma material interactions under fusion reactor divertor conditions as will occur in devices like DEMO, including the plasma exposure of a-priori neutron irradiated materials. This requires a novel linear plasma device with a plasma source that can produce high electron densities along with heating systems to obtain high electron and ion temperatures. In Proto-MPEX a high-power helicon source was tested together with electron heating (28 GHz microwaves) and ion cyclotron heating (8.5-12 MHz). Electron densities in excess of 1 × 1020 m-3 were produced with the helicon antenna. Electron temperatures can reach 20 eV and are typically below 6 eV at high densities (>5 × 1019 m-3). Ion heating has been demonstrated at low electron densities (<2 × 1019 m-3) with ion temperatures of up to 13 eV. Maximum heat fluxes of 14 MW/m2 have been obtained in low density discharges (~5 × 1018 m-3), while heat fluxes are typically only 2–3 MW/m2 in high density discharges (>2 × 1019 m-3).

Rapp, Juergen↗

Evidence of electron heating at different radial locations on Proto-MPEX

This paper reports on the observation of controlled underdense electron heating for high heat flux applications in the Prototype Material Plasma Exposure eXperiment. The goal of this experiment is to demonstrate the source and heating concepts to create a high intensity plasma at material targets to study plasma-material interactions in similar plasma conditions to magnetic fusion divertors. A 80 kW helicon source at 13.56 MHz is used for the plasma density production and a 15 kW microwave source at 28 GHz is used for electron heating. Moreover, for electron densities ~5 × 10 18 m -3 , the electron temperature at the target location increases from 2 eV to 5 eV and the core heat flux increases by a factor of 5. It is shown that the radial profile of the heat flux delivered at the target can be controlled by either the background plasma density or the magnetic field. In conclustion, analysis suggests that the electron heating is due to heating near the upper-hybrid resonance layer and that this heating scenario may scale up to divertor-relevant electron densities ~5 × 10 19 m -3 by increasing the microwave driving frequency to 105 GHz.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ways to improve the efficiency and reliability of radio frequency driven negative ion sources for fusion

Large RF driven negative hydrogen ion sources are being developed at IPP Garching for the future neutral beam injection system of ITER. The overall power efficiency of these sources is low, because for the RF power supply self-excited generators are utilized and the plasma is generated in small cylindrical sources (“drivers”) and expands into the source main volume. At IPP experiments to reduce the primary power and the RF power required for the plasma production are performed in two ways: The oscillator generator of the prototype source has been replaced by a transistorized RF transmitter and two alternative driver concepts, a spiral coil, in which the field is concentrated by ferrites, which omits the losses by plasma expansion and a helicon source are being tested.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗