Geothermal Heat Pump System Showcase: Short-Term Validation of Borehole Heat Exchanger Performance from Field Data to Numerical Modeling: Preprint

Since 2011, a geothermal heat pump (GHP) system has been operating to provide space heating and cooling for the Solar Radiation and Research Laboratory building at the National Laboratory of the Rockies (NLR) in Golden, Colorado. The system consists of 23 vertical boreholes, each extending to a depth of 300 ft (91 m), connected to 11 water-to-air heat pump units and four circulation pumps. Between fiscal years 2023 and 2025, additional power meters and temperature sensors were retrofitted to support detailed system performance assessment and model development. This study presents preliminary monitoring results and the development of an initial numerical model of the borehole heat exchanger field. The model incorporated site-specific geometry, ground thermal properties derived from thermal response tests, and ambient temperatures, and simulated system behavior over a representative operating day in September. Model predictions of outlet temperatures were compared against corresponding field measurements. Results showed that modeling initialized with a simplified linear subsurface temperature gradient presents systematic discrepancies in outlet temperature, whereas incorporating depth-resolved borehole temperature measurements for initialization yields substantially improved agreement with observations. The findings highlight the sensitivity of short-term predictive modeling to the representation of initial subsurface thermal conditions and underscore the value of high-resolution field measurements for model calibration and validation. These preliminary results inform ongoing efforts to extend the modeling framework to longer time horizons and to refine monitoring and modeling strategies that support the design guidance and operational optimization of GHP systems in research and commercial buildings.

15 GEOTHERMAL ENERGY↗

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗

Flow dynamics and heat transfer in simplified battery energy storage systems with heated battery modules

Large-scale energy storage systems (ESSs) composed of batteries show promise in addressing current energy challenges, but dissipation of generated heat is important. Here, this paper focuses on buoyant convective flows in simplified ESS battery racks. Natural convection is not generally the primary cooling strategy but can be important in abnormal scenarios where there is module overheat or potentially thermal runaway. We use computational fluid dynamics to investigate the flow dynamics and heat transfer mechanisms in a simplified parameterized rack design. Despite its simplicity, this configuration produces many of the relevant features expected in real ESSs without details of module geometry or hardware, allowing broad conclusions independent of manufacture-specific designs. We start by providing visualizations of the flowfield and measurements of entrainment, heat flux, and pressure. To characterize the dependence on the system parameters, we develop an integral-scale analysis of the average temperature equation to highlight the dominant source terms. We use results from this analysis to derive a steady network model composed of simple algebraic expressions to provide first-order predictions of entrainment through the rack. The network model leads to a linear scaling of the Reynolds number based on convective mass flux with respect to the Grashof number based on the heat source. We deduce empirical relationships that relate the heat exchanged between modules using a surface-averaged Nusselt number as a function of the local Reynolds and Rayleigh numbers. Lastly, we investigate how space between the modules and rack in the spanwise direction creates flow bypass, resulting in different flow pathways.

Battery thermal management↗

Heat dissipation systems with hygroscopic working fluid

A heat dissipation system apparatus and method of operation using hygroscopic working fluid for use in a wide variety of environments for absorbed water in the hygroscopic working fluid to be released to minimize water consumption in the heat dissipation system apparatus for effective cooling in environments having little available water for use in cooling systems. The system comprises a low-volatility, hygroscopic working fluid to reject thermal energy directly to ambient air. The low-volatility and hygroscopic nature of the working fluid prevents complete evaporation of the fluid and a net consumption of water for cooling, and direct-contact heat exchange allows for the creation of large interfacial surface areas for effective heat transfer. Specific methods of operation prevent the crystallization of the desiccant from the hygrosopic working fluid under various environmental conditions.

Martin, Christopher L.↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

Waste heat recovery system and control

A waste heat recovery (WHR) system that can be utilized in internal combustion engine systems includes at least two circuits, one having a low pressure working fluid and another having a high pressure working fluid. Each circuit can include heat exchangers to allow the working fluid to absorb heat form one or more heat source fluids associated with the engine. The system can also include an expander configured to receive the working fluid from the at least two circuits, and generating mechanical power. The system also can include a condenser, a sub cooler, and at least one working fluid pump to pump the working fluid in the at least two circuits. The cooling system also includes a controller that can receive temperature and pressure values from various locations in the WHR system and control at least the flow rates of the working fluids in the at least two circuits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Open-cycle thermochemical energy storage for building space heating: Practical system configurations and effective energy density

Salt-hydrate thermochemical materials (TCM) are promising candidates for energy storage systems for building space heating due to their high theoretical energy density and the need for low regeneration temperature. However, water vapor is required to drive the hydration process of the TCM reactor, which poses a challenge during winter when water vapor is typically scarce. Using indoor air directly lowers the building's humidity to an unconformable level in practice, while the cold outdoor air contains limited moisture. Here we consider different integration strategies for open-cycle TCM reactors in buildings and develop a model to simulate their thermal performance across diverse buildings and climates, specifically for building space heating. The potential energy densities and the levelized cost of storage of the TCM reactor are evaluated in practical scenarios to demonstrate the load-shifting potential of TCM systems for heating applications. We use a strontium chloride (SrCl 2 )-based composite as the baseline and explore the impact of various reactor and material changes to the energy density and levelized cost of storage.

25 ENERGY STORAGE↗

Identification of Important Phenomena for Light Water Reactors During Heat Transport System Failure Events in Integrated Energy Systems

This work adapts historical literature and existing phenomena identification and ranking tables (PIRT) to be applicable to a novel nuclear power plant (NPP) and chemical or thermal process integrated energy system (IES), particularly focusing on the process heat and heat transport system failure events that are not a concern during normal NPP operation but become vital when an IES is considered. Nuclear energy has been suggested to go beyond base-load applications and be used for hydrogen co-generation systems, amongst other IESs. Prior to the implementation of nuclear IESs, sufficient analysis must be performed on accident events to ensure public safety. The events considered were deemed important because of their potential to damage systems, structures, and components (SSCs). Process thermal events of concern include loss of heat load and temperature transient events. Loss of heat load events were characterized as having high importance and being well understood. Temperature transient events may be further categorized by the cyclic loading and harmonics phenomena. Cyclic loading issues were classified as medium to high importance with knowledge gaps existing regarding fatigue and low power operation, while harmonics phenomena were classified as low importance and are well understood. Heat transport system failure events of concern include intermediate and process heat exchanger failures, mass addition to reactor coolant, ingress of material from thermal manifold/energy storage, and loss of intermediate fluid. Furthermore, these events tended to be of high or medium importance, with some knowledge gaps needing to be filled for individual reactor systems due to unique designs.

Integrated Energy System (IES)↗

Improvements to Passive Heat Removal Systems in SAS4A/SASSYS-1

Safe operation of a sodium cooled fast reactor (SFR) can be significantly aided by heat removal systems that do not rely on active power, but function using passive means. Passive heat removal from such reactors can employ systems that extract heat directly from sodium coolant by utilizing heat exchangers submerged in the coolant and natural circulation of a metal fluid sodium (or sodium potassium eutectic) to heat exchangers (generally air cooled) externally located. These types of systems are generally called Direct Reactor Auxiliary Cooling Systems (DRACS). Another type of passive heat removal system particularly suitable for pool-type SFRs relies on indirect extraction of heat by utilizing air flow in an annular region surrounding the reactor guard vessel which discharges the heat via the chimney effects to the atmosphere. These systems are generally called Reactor Vessel Auxiliary Cooling Systems (RVACS).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimization of a Residential Air Source Heat Pump using Refrigerants with GWP <150 for Improved Performance and Reduced Emission

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of heat pump systems. Heat exchangers and compressors are the key components and have a prominent impact on system performance, significant research is devoted to reducing the cost of the heat exchangers while achieving the same or better system performance with refrigerant charge reduction.To better understand the environmental impacts of optimized systems with low-GWP refrigerants, Life Cycle Climate Performance (LCCP) evaluation method was used to evaluate the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. The DOE/ORNL Heat Pump Design Model (HPDM) is used to evaluate the performance of heat pumps. Multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm are performed on a 3-ton R410A residential air source heat pump on market. Seven R410A alternatives, i.e., R32, R454B, R454C, R455A, R457A, R1234yf and R1234ze(E) are investigated. The last five fluids have GWP lower than 150.As a result, 5.5%-12.8% seasonal energy efficiency ratio 2 (SEER2) improvement is achieved, and the optimized systems reduce life cycle CO2 emission by 8.5%-28.6% with GWP lower than 150 refrigerants. The optimal heat exchangers can fit into the original R410A fan-coil units; therefore, the proposed design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗

Dynamic Life Cycle Assessment for Evaluating the Global Warming Potential of Geothermal Energy Production Using Inactive Oil and Gas Wells for District Heating in Tuttle, Oklahoma

Repurposing abandoned oil and gas infrastructure for geothermal energy production has great potential to reduce greenhouse gas (GHG) emissions. This study quantified the life cycle global warming potential of geothermal energy production using four inactive oil and gas wells repurposed for district heating in Tuttle, Oklahoma. A cradle-to-grave prospective life cycle assessment was performed to compare GHG emissions between the geothermal district heating system and conventional natural gas-fired heating system from 2020 to 2050. For initial implementation of the geothermal system, we investigated two approaches: 1) repurposing abandoned infrastructure from a nearby oil and gas well site, and 2) production and injection well drillings including new construction of a central heat exchange station. Environmental impacts from the geothermal system were estimated for five scenarios where a natural gas peaking boiler is incorporated to supply peak heat demand. The prospective results indicated that cumulative reduction in GHG emissions from transitioning to the geothermal district heating system increase over time as a function of future renewable resource penetration and technological advancements within electricity, fuel, and steel production. Over 30 years, the global warming potential associated with the district heating demand will have been reduced by up to 24 % with the repurposed system. These results imply that repurposing existing oil and gas infrastructure for geothermal energy systems of district heating will bring future climate benefits.

abandoned oil and gas wells↗

Overview of the first Wendelstein 7-X long pulse campaign with fully water-cooled plasma facing components

After a long device enhancement phase, scientific operation resumed in 2022. The main new device components are the water cooling of all plasma facing components and the new water-cooled high heat flux divertor units. Water cooling allowed for the first long-pulse operation campaign. A maximum discharge length of 8 min was achieved with a total heating energy of 1.3 GJ. Safe divertor operation was demonstrated in attached and detached mode. Stable detachment is readily achieved in some magnetic configurations but requires impurity seeding in configurations with small magnetic pitch angle within the edge islands. Progress was made in the characterization of transport mechanisms across edge magnetic islands: Measurement of the potential distribution and flow pattern reveals that the islands are associated with a strong poloidal drift, which leads to rapid convection of energy and particles from the last closed flux surface into the scrape-off layer. Using the upgraded plasma heating systems, advanced heating scenarios were developed, which provide improved energy confinement comparable to the scenario, in which the record triple product for stellarators was achieved in the previous operation campaign. However, a magnetic configuration-dependent critical heating power limit of the electron cyclotron resonance heating was observed. Exceeding the respective power limit leads to a degradation of the confinement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Equipment Procurement and Final Design for the MARVEL High-Grade Heat Extraction System (HGHES)

This summer I worked on the design of a high-grade heat extraction system (HGHES) of the MARVEL Project. The MARVEL project at INL is a first-of-a-kind terrestrial microreactor to help provide a test platform to demonstrate the use of a microreactor to end customers and enable technology developers to test enabling microreactor technologies with a functional nuclear reactor. One of the project's main requirements is the reactors’ ability to deliver high-grade thermal power to end users, both for industrial and commercial use. The project required communication with multiple vendors for custom-made equipment, working with a high-temperature and high-pressure helium coolant system, and research of a Thermal Storage Unit (TSU).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance evaluation of underground thermal storage integrated dual-source heat pump systems

The increasing demand for electricity stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Integrating thermal energy storage (TES) in building heating/cooling systems, which consume considerable electricity, can mitigate the challenges to electric grids. Here, this study reports on a novel thermal energy storage device integrated heat pump system to reshape the building electricity demand profile while maintaining thermal comfort. The annual performance of the proposed system has been evaluated through a dynamic system simulation with high fidelity in the Modelica platform. The dynamic model of the novel hybrid component named ‘dual purpose underground thermal battery’ was developed and validated. It was then incorporated into the system model. Given a time-of-use tariff, a rule-based control strategy was designed to shift the electric demand and switch the heat pump source for a typical single-family house in different climate zones of the United States. The system performance of the new TES-integrated dual-source heat pump was compared with that of a conventional air-source heat pump system. The results indicate that the proposed system can reduce the annual HVAC electricity cost by up to 52% while saving 45.2% on electricity consumption. In the Northern areas, the annual peak load of the HVAC system can be reduced by 64.9%. However, this reduction is less in the Southern areas as the system’s higher efficiency in winter dominates the overall energy-saving potential.

25 ENERGY STORAGE↗

Primary Heat Transport System Design Considerations for Xcimer Energy’s Athena Fusion Pilot Plant

Fusion energy promises a reliable, carbon-free source of power; however, significant challenges remain before it can be deployed as an economical energy source. In addition to achieving fusion conditions, power plants must operate under extreme temperatures, radiation, and mechanical loads while maintaining high efficiency and availability. These requirements place strong demands on engineering design and plant operation. This work focuses on the engineering challenges associated with balance of plant analysis for inertial fusion energy systems. In particular, this paper examines the design considerations for primary heat transfer systems in fusion pilot plants employing molten fluoride salt coolants, with particular emphasis on system layout optimization and the balance between competing design objectives using the Xcimer Energy Athena inertial pilot plant design as a case study. Through systematic analysis of candidate system configurations and parametric sensitivity studies, we identify key engineering trade-offs governing salt inventory, pumping power requirements, and operational flexibility. The analysis employs system-level modeling tools to explore the design space and establish relationships between geometric parameters and system performance metrics.

Greenwood, Scott [ORNL] (ORCID:0000000333480736)↗

SPC-71145 Rev 0 MARVEL Process Heat Extraction System Conceptual Design

The Microreactor Applications Research Validation and Evaluation (MARVEL) reactor will offer experimental capabilities that are not currently available at DOE’s national laboratories. The MARVEL reactor is a microreactor which uses eutectic sodium-potassium alloy (NaK) as a primary coolant. The primary coolant is circulated through four primary loops by natural convection of the coolant. In each loop is a closed well which will accommodate an intermediate heat exchanger (IHX) for extracting heat from the loop. These wells will be referred to in this specification as the “IHX wells”. It is intended for the IHX containment to also be filled with NaK. The MARVEL design team is currently looking for alternative means of extracting heat from these wells to be utilized in downstream applications. This Heat Utilization System (HUS) will enable MARVEL operations including the ability to test, demonstrate, and address issues related to installation, startup, and operations. In addition, it will allow down-stream utilization of process heat for various uses. Depending on the methodology used, the interface between the secondary coolant and the HUS is the Process Heat Extraction System (PHES) and is the subject of this specification.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Validation of a Co-Optimized, Smart Hybrid Heat Pump Control

This study examines a residential dual fuel (DF) heating system that integrates heat pump and gas furnace technology with a home’s forced-air distribution ducts. Specifically, it explores a retrofit where an “add-on” heat pump replaces the air conditioning (A/C) system and is combined with the home’s existing furnace and air handler. The research team developed and validated an innovative control scheme for this integrated DF system that selected the more economical heating source (furnace or heat pump) while maintaining comfort in the home. The project’s field study and subsequent modeling analysis show that this control scheme can decrease energy use, cost, and emissions compared to a furnace-only system. As homes in mixed and cold climates transition to more electric space heating, furnace-to-dual fuel system retrofits offer a solution that can alleviate the retrofit costs, energy cost concerns, and peak load impacts of full electrification.