Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ground loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Universal tritium transmitter

At the Savannah River Site and throughout the National Nuclear Security Agency (NNSA) tritium is measured using Ion or Kanne Chambers. Tritium flowing through an Ion Chamber emits beta particles generating current flow proportional to tritium radioactivity. Currents in the 1 x 10{sup -15} A to 1 x 10{sup -6} A are measured. The distance between the Ion Chamber and the electrometer in NNSA facilities can be over 100 feet. Currents greater than a few micro-amperes can be measured with a simple modification. Typical operating voltages of 500 to 1000 Volts and piping designs require that the Ion Chamber be connected to earth ground. This grounding combined with long cable lengths and low currents requires a very specialized preamplifier circuit. In addition, the electrometer must be able to supply 'fail safe' alarm signals which are used to alert personnel of a tritium leak, trigger divert systems preventing tritium releases to the environment and monitor stack emissions as required by the United States federal Government and state governments. Ideally the electrometer would be 'self monitoring'. Self monitoring would reduce the need for constant checks by maintenance personnel. For example at some DOE facilities monthly calibration and alarm checks must be performed to ensure operation. NNSA presently uses commercially available electrometers designed specifically for this critical application. The problems with these commercial units include: ground loops, high background currents, inflexibility and susceptibility to Electromagnetic Interference (EMI) which includes RF and Magnetic fields. Existing commercial electrometers lack the flexibility to accommodate different Ion Chamber designs required by the gas pressure, type of gas and range. Ideally the electrometer could be programmed for any expected gas, range and high voltage output. Commercially available units do not have 'fail safe' self monitoring capability. Electronics used to measure extremely low current must have sufficient time to thermally equilibrate. Amplifiers, transistors, resistors all need time to stabilize before the electrometer circuit will measure accurately in the 10{sup -15} and 10{sup -14} ampere range. Existing electrometers give the user no indication when the unit has stabilized and is acceptable for low level measurements. Savannah River National Laboratory (SRNL) funded through the NNSA Plant Directed Research and Development (PDRD) program, has developed a truly Universal Tritium Transmitter (UTT) capable of solving many known problems with existing commercial electrometers. This UTT pushes the state-of-the-art in electrometer design and incorporates solutions to deficiencies found in commercial electrometers. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recovery Act: Cedarville School District Retrofit of Heating and Cooling Systems with Geothermal Heat Pumps and Ground Source Water Loops

Cedarville School District retrofitted the heating and cooling systems in three campus areas (High School, Middle School, and Upper Elementary School) with geothermal heat pumps and ground source water loops, as a demonstration project for the effective implementation of geothermal heat pump systems and other energy efficiency and air quality improvements.

15 GEOTHERMAL ENERGY↗

Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season. Upon completion of the monitoring phase, measurements revealed that the initial TRNSYS simulated horizontal sub-slab ground loop heat exchanger fluid temperatures and heat transfer rates differed from the measured values. To determine the cause of this discrepancy, an updated model was developed utilizing a new TRNSYS subroutine for simulating sub-slab heat exchangers. Measurements of fluid temperature, soil temperature, and heat transfer were used to validate the updated model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Resilience of Residential Building with Thermally Anisotropic Building Envelope Connected to Geothermal Sources

Heat waves and cold snaps have become more frequent and more intense because of climate change. A heat wave and a cold snap are a period of excessively hot and cold weather, respectively, that poses severe risks to building occupants’ health, especially for vulnerable people. They increase electrical energy consumption and put high stress on the grid which leads to potential power outages. Therefore, it is critical to assess and actively improve the thermal resilience of buildings to cope with heat waves, cold snaps, and power outages. The thermally anisotropic building envelope (TABE) is a novel active building envelope that can save energy while maintaining thermal comfort in buildings by redirecting heat and coolness from building envelopes to hydronic loops. When connecting to a ground thermal loop (GL), TABE can utilize the relatively stable temperature of the ground to protect the indoor environment during heat waves and cold snaps. This study assesses the thermal resilience of residential buildings that installed TABE and used ground thermal energy to supply the hydronic loops, abbreviated as ground thermal loop or TABE+GL. The simulation and analysis are conducted for the US Department of Energy prototype single-family detached residential building in the hot climate of Miami, Florida and Tucson, Arizona, and the cold climate of Denver, Colorado, and Rochester, Minnesota. Heat waves and cold snaps were obtained from the historical weather data of 1998-2020 for the studied regions. Three thermal resilience metrics, including the standard effective temperature (SET) degree-hours, the Heat Index, and the Hours of Safety (HOS) were used to quantify the effect of TABE+GL. The results showed that buildings installed TABE+GL could significantly reduce the average SET degree-hours above 30°C, increase HOS, and greatly improve thermal resilience.

Shen, Zhenglai↗

Loop Antennas for Use On/Off Ground Planes

Many applications benefit from the ability of an RFID tag to operate both on and off a conducting ground plane. This paper presents an electrically small loop antenna at 433 MHz that passively maintains its free-space tune and match when located a certain distance away from a large conducting ground plane. The design achieves this using a single radiation mechanism (that of a loop) in both environments without the use of a ground plane or EBG/AMC structure. An equivalent circuit model is developed that explains the dual-environment behavior and shows that the geometry balances inductive and capacitive parasitics introduced by the ground plane such that the free-space loop reactance, and thus resonant frequency, does not change. A design equation for balancing the inductive and capacitive parasitic effects is derived. Finally, experimental data showing the design eliminates ground plane detuning in practice is presented. The design is suitable for active, “hard” RFID tag applications.

42 ENGINEERING↗

Recovery Act: Finite Volume Based Computer Program for Ground Source Heat Pump Systems

This report is a compilation of the work that has been done on the grant DE-EE0002805 entitled Finite Volume Based Computer Program for Ground Source Heat Pump Systems. The goal of this project was to develop a detailed computer simulation tool for GSHP (ground source heat pump) heating and cooling systems. Two such tools were developed as part of this DOE (Department of Energy) grant; the first is a two-dimensional computer program called GEO2D and the second is a three-dimensional computer program called GEO3D.

15 GEOTHERMAL ENERGY↗

Two-loop self-energy for the ground state of medium-Z hydrogenlike ions

The two-loop self-energy correction to the ground-state Lamb shift is calculated for hydrogenlike ions with the nuclear charge Z=10-30 without any expansion in the binding field of the nucleus. A calculational technique is reported for treatment of Feynman diagrams in the mixed coordinate-momentum representation, which yields significant improvement in numerical accuracy as compared to previous results. An extrapolation of the all-order numerical data yields a result for the higher-order remainder function for hydrogen. The previously reported disagreement between the all-order and the perturbative approaches is reduced to the marginal agreement.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measured Performance and Analysis of Ground Source Heat Pumps for Space Conditioning and for Water Heating in a Low-Energy Test House Operated under Simulated Occupancy Conditions

In this paper we present measured performance and efficiency metrics of Ground Source Heat Pumps (GSHPs) for space conditioning and for water heating connected to a horizontal ground heat exchanger (GHX) loop. The units were installed in a 345m2 (3700ft2) high-efficiency test house built with structural insulated panels (SIPs), operated under simulated occupancy conditions, and located in Oak Ridge, Tennessee (USA) in US Climate Zone 4 . The paper describes distinctive features of the building envelope, ground loop, and equipment, and provides detailed monthly performance of the GSHP system. Space conditioning needs of the house were completely satisfied by a nominal 2-ton (7.0 kW) water-to-air GSHP (WA-GSHP) unit with almost no auxiliary heat usage. Recommendations for further improvement through engineering design changes are identified. The comprehensive set of data and analyses demonstrate the feasibility and practicality of GSHPs in residential applications and their potential to help achieve source energy and greenhouse gas emission reduction targets set under the IECC 2012 Standard.

efficiency↗

Machine learning–assisted prediction of heat fluxes through thermally anisotropic building envelopes

Thermally anisotropic building envelope (TABE) is a novel active building envelope that can save energy use to maintain thermal comfort in buildings by redirecting heat and coolness from building envelopes to thermal loops. Finite element models (FEMs) can be used to compute the heat fluxes through TABEs, but the high computational cost of finite element simulations has prevented parametric studies and design optimizations. This paper proposes a domain knowledge–informed, finite element–based machine learning framework to reduce the computation cost for the energy management of buildings installed with TABE that uses a ground thermal loop. First, the training heat flux data set was generated by FEM simulations with different thermal loop schedules. Then, both shallow learning models (i.e., multivariate linear regression and eXtreme Gradient Boost, or XGBoost) and a deep learning model (i.e., deep neural network, or DNN) were trained to predict the heat fluxes. Domain knowledge was used for data preprocessing and feature selection. Finally, the suitability of the selected machine learning model was tested under different thermal loop schedules. Herein, the case study results showed that: (1) XGBoost can be as accurate as DNN (coefficient of determination equal to 0.81) with much less training time; (2) the annual energy cost savings for different thermal loop schedules obtained by the XGBoost-predicted and FEM-calculated heat fluxes are consistent, having a difference of only 4%; and (3) XGBoost can reduce the computation time for the annual energy analysis of the case study building with a given thermal loop schedule from around 12 h by using FEM to less than 1 min.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

North Village Ground Source Heat Pump Demonstration Project

This project demonstrated the feasibility of converting from a traditional direct exchange system to a ground source heat pump system on a large scale, multiple building apartment complex on a university campus. A total of ten apartment buildings were converted using vertical well fields and a ground source loop that connected the 24 apartments in each building into a common system. The system has yielded significant operational savings in both energy and maintenance and transformed the living environments of these residential buildings for our students.

15 GEOTHERMAL ENERGY↗

Case Study for the ARRA-funded GSHP Demonstration at Furman University

With funding provided by the American Recovery and Reinvestment Act, 26 ground source heat pump (GSHP) projects were competitively selected in 2009 to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. One of the selected demonstration projects was proposed by Furman University for ten student housing buildings—the North Village located on the campus in Greeneville, South Carolina. All ten buildings are identical in floor plan and construction. Each building is conditioned by an identical GSHP system consisting of 25 water-to-air heat pump (WAHP) units, a closed-loop vertical ground heat exchanger (GHX) installed under an adjacent parking lot, and two redundant 7.5 hp variable-speed pumps to circulate water through the GHX and the WAHPs. The actual performance of the GSHP systems is analyzed with available measured data for 2014. The annual energy performance is compared with a baseline scenario in which the building is conditioned by air-source heat pumps (ASHPs) with the minimum allowed efficiencies specified in ASHRAE Standard 90.1-2013 (SEER 13 for cooling and 7.8 HSPF for heating) and supplemental electric heaters. The comparison is made in terms of energy savings, operating cost savings, cost-effectiveness, and environmental benefits. Finally, limitations in conducting this analysis are identified and recommendations for further improving the operational efficiency of the GSHP systems are made.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

NREL GHP [Geothermal Heat Pump] Showcase: GHP Installation and Intensive in situ and Performance Monitoring at NREL's Solar Radiation and Research Laboratory; Preprint

This document provides an overview of the geothermal heat pump (GHP) showcase at NREL and how it will help the SRRL site move forward with the goal of being a model of sustainability within the NREL campus, providing an effective demonstration of GHP systems and needed space conditioning for laboratory expansion.

15 GEOTHERMAL ENERGY↗

De-tuning tolerant loop antenna

A loop antenna is described herein that is suitable for operation in free space or in proximity to a ground plane. The loop antenna comprises a looped conductive element with a gap formed therein and a tab extending toward the gap. A length of the tab of the loop antenna is selected such that a detuning loss of the loop antenna from operation in free space to operation in proximity to a ground plane is low. In an exemplary embodiment, the length of the tab is selected such that a reactance of the loop antenna in free space is within a threshold level of a reactance of the loop antenna when the antenna is in proximity to a ground plane.

42 ENGINEERING↗

Open spin chains for giant gravitons and relativity

In this work, we study open spin chains for strings stretched between giant graviton states in the N=4 SYM field theory in the collective coordinate approach. We study the boundary conditions and the effective Hamiltonian of the corresponding spin chain to two loop order. The ground states of the spin chain have energies that match the relativistic dispersion relation characteristic of massive W boson particles on the worldvolume of the giant graviton configurations, up to second order in the limit where the momentum is much larger than the mass. We find evidence for a non-renormalization theorem for the ground state wave function of this spin chain system. We also conjecture a generalization of this result to all loop orders which makes it compatible with a fully relativistic dispersion relation. We show that the conjecture follows if one assumes that the spin chain admits a central charge extension that is sourced by the giant gravitons, generalizing the giant magnon dispersion relation for closed string excitations. This provides evidence for ten dimensional local physics mixing AdS directions and the five-sphere emerging from an N=4 SYM computation in the presence of a non-trivial background (made of D-branes) that break the conformal field theory of the system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗