Engineering PapersSearch

SEARCH · Engineering Papers

Results for “gridded population”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

IM3 Data Center Driven Grid Stress Dataset for the U.S. Western Interconnection

This dataset provides projected grid stress and reliability results (including all model inputs and outputs from an open-source grid operations modeling framework - GO), for the Integrated Multisector, Multiscale Modeling (IM3) project, under varying levels of data center demand growth between 2025 and 2035 in the U.S. Western Interconnection. The scenarios and sensitivity experiments are combinations of different data center demand growth rates and energy, weather, population and economic pathways. Data center demand growth projections were sourced from the Electric Power Research Institute (EPRI). The data center demand growth projection names are: Low (3.71% annual data center demand growth) Moderate (5% annual data center demand growth) High (10% annual data center demand growth) Higher (15% annual data center demand growth) Energy, weather, population and economic pathways are informed by two Shared Socioeconomic Pathways (SSP3 and SSP5) and two Representative Concentration Pathways (RCP4.5 and RCP8.5) following the hotter general circulation model (GCM) forcing group from a set of perturbed thermodynamics simulations. The resulting pathway names are: rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 The main scenarios and sensitivity experiments are detailed below. Reference scenario: The projected grid stress and reliability results for the U.S. Western Interconnection from a previous study. This scenario does not consider data center demand growth explicitly. Data center scenario: Building on the reference scenario, this scenario considers various data center growth rates and how they impact the U.S. Western Interconnection. Data center loads are modeled as flat 8760-hr profiles. This scenario does not consider new generation and transmission capacities specifically designed to meet the new data center demands. The related folder is named "flat". Delayed generator retirements sensitivity experiment: Building on the data center scenario, this experiment explores the impact of different levels of natural gas and nuclear generator retirement delays. The resulting scenario names are: (1) postponing 100% nuclear retirements; (2) postponing 100% nuclear and 25% natural gas retirements; (3) postponing only 50% natural gas retirements; (4) postponing 100% nuclear and 50% natural gas retirements; (5) postponing 100% nuclear and 75% natural gas retirements; and (6) postponing 100% nuclear and 100% natural gas retirements. The related folder names are: no_gen_retire_0_gas, no_gen_retire_25_gas, no_gen_retire_50_gas, no_gen_retire_50_gas_only, no_gen_retire_75_gas, and no_gen_retire_100_gas. Demand response through curtailment sensitivity experiment: Building on the data center scenario, this experiment explores the impact of different participation and compensation levels of data center demand response. The resulting scenario names are: (1) 5% demand available for curtailment with 750 $/MWh compensation; (2) 5% demand available for curtailment with 500 $/MWh compensation; (3) 5% demand available for curtailment with 250 $/MWh compensation; (4) 15% demand available for curtailment with 750 $/MWh compensation; (5) 15% demand available for curtailment with 500 $/MWh compensation; and (6) 15% demand available for curtailment with 250 $/MWh compensation. The related folder names are: dr_cost_250_drup_0_drdown_5, dr_cost_250_drup_0_drdown_15, dr_cost_500_drup_0_drdown_5, dr_cost_500_drup_0_drdown_15, dr_cost_750_drup_0_drdown_5, and dr_cost_750_drup_0_drdown_15. Combination of delayed generator retirements and demand response through curtailment sensitivity experiment: The impact of combining postponing 100% nuclear and 25% natural gas retirements with 5% demand available for curtailment with 750 $/MWh compensation is simulated. The related folder is named "dr_cost_750_drup_0_drdown_5_nuc_100_gas_25". Please refer to the README file for a detailed description of the dataset including individual files and references.

Artificial Intelligence

A Physical Model Enhanced Data Driven Method for High-Resolution Residential Load Profile Generation

Residential buildings account for significant energy consumption, creating opportunities to offer grid services. As electric utilities seek to implement effective system operation strategies, understanding residential energy consumption patterns becomes essential; However, the time intervals of load profiles measured by utilities' smart meters are typically from 15 minutes to 60 minutes. The low-resolution data make it hard to extract appliance-level load information, which is critical for providing grid services. This paper presents a load profile generator designed to produce synthetic load profiles for residential buildings that emphasizes the importance of accurate representations of realistic energy consumption patterns. The generator takes realistic low-resolution residential load measurements and weather data as inputs, producing 1-minute interval profiles that match the characteristics of the original profiles. Further, this generator can be used to populate load profiles in areas where actual measurements are limited to improve the ability of utilities to analyze their distribution systems. By providing more high-resolution residential building load profiles, this tool supports electric utilities to enhance their residential building load control strategies and improve overall grid stability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

LandScan Mosaic Time Series Version 1.0: 1975-2024

The LandScan Mosaic Annual Global Ambient Population Time Series, Version 1.0, provides annual high-resolution global ambient population estimates from 1975 to 2024. The dataset is distributed as one Cloud-Optimized GeoTIFF per year on a globally aligned 3 arc-second WGS 84 grid. The 2024 layer is the LandScan Mosaic benchmark reference year, while the 1975–2023 layers are historical estimates generated using the LandCast backcasting framework.

Zimmer, Andrew [ORNL] (ORCID:0000000176838713)

Tethys Water Demand Data

U.S. water demand varies sharply by sector and region as land use, population, weather patterns, and economic activity co-evolve. High-resolution water demand data is required to capture these dynamics, support integrated energy-water-land modeling, and local-to-regional water scarcity assessments. This dataset contains gridded (1/8 degree), monthly, multi-sector water demand dataset for the contiguous United States (CONUS) covering 1980-2100 across eight future scenarios of human-Earth system change. The dataset covers irrigation, thermoelectric, municipal (public-supply and domestic), livestock, manufacturing, and mining demands, separately for withdrawals and consumption, and includes per-cell renewable vs. non-renewable water source attributions. The dataset is validated against the latest USGS 2010-2020 water-use data for the three largest water demand sectors (Domestic, Electricity, and Irrigation), with correlations ranging from 0.73-0.95 at the HUC6 scale. The two datasets largely agree on an aggregate basis with per-sector bias falling within +/-7%, but they disagree on the spatial allocation of water with individual HUC6 basins having normalized RMSE from 68-171% and median absolute percent difference from 37-86%. This dataset advances prior global products by combining state-resolved sectoral demands from GCAM-USA, future power-plant siting from the CERF model, and scenario-consistent high-resolution climate and population forcing data across the eight scenarios.

GCAM-USA

Spatiotemporal predictions of toxic urban plumes using deep learning

Industrial accidents, chemical spills, and structural fires can release large amounts of harmful materials that disperse into urban atmospheres and impact populated areas. Computer models are typically used to predict the transport of toxic plumes by solving fluid dynamical equations. However, these models can be computationally expensive due to the need for many grid cells to simulate turbulent flow and resolve individual buildings and streets. In emergency response situations, alternative methods are needed that can run quickly and adequately capture important spatiotemporal features. Here, we present a novel deep learning model called ST-GasNet inspired by the mathematical equations that govern the behavior of plumes as they disperse through the atmosphere. ST-GasNet learns the spatiotemporal dependencies from a limited set of temporal sequences of ground-level toxic urban plumes generated by a high-resolution large eddy simulation model. On independent sequences, ST-GasNet accurately predicts the late-time spatiotemporal evolution, given the early-time behavior as an input, even when a building splits a large plume into smaller plumes. By incorporating large-scale wind boundary condition information, ST-GasNet achieves a prediction accuracy of at least 90% on test data for the entire prediction period.

Civil and Environmental Engineering

Ocean Wave Energy Harvester with Oak Ridge Converter

Oceans can provide great potential for the American energy dominance. There is significant potential to utilize marine energy resources. In the United States, the total amount of marine energy available is equivalent to about 57% of the country's total power generation in 2019. Even if a fraction of this technical potential is harnessed, marine energy technologies could play a crucial role in fulfilling the nation's energy requirements. Marine energy resources are spread out geographically, and because more than 50% of the United States' population resides within 50 miles of the coastline, they are well-positioned to power local communities. These resources are also very dependable, making them a viable option for contributing to a consistent, trustworthy energy grid. Due to their predictable daily and seasonal patterns, marine energy resources can be integrated into our energy generation portfolio. On the other hand, ocean environment presents many challenges for cost-effective renewable energy conversion, including optimal control of ocean wave energy. This report presents a novel cost-effective energy conversion technique for ocean wave energy harvesters. The proposed system is simulated by using the Oak Ridge Converter to directly interface ocean wave energy source with the utility grid. The system description and simulation results are presented in detail. The results show that the proposed system is a cost effective and promising technology to reduce the infrastructure cost for ocean wave energy harvesters.

Sutton, Elizabeth [ORNL] (ORCID:0009000078885935)

Energy Technology Innovation Partnership Project Strategic Energy Plan for Washington County, Maine

This Strategic Energy Plan (SEP) for Washington County, Maine was developed through the U.S. Department of Energy's Energy Technology Innovation Partnership Project (ETIPP) to address local challenges related to electricity reliability, affordability, and safety. Grounded in a "relational infrastructure" approach, the plan recognizes that improved energy outcomes depend not only on physical grid investments but also on strengthened coordination and trust between utilities and communities. Using utility-provided reliability data, public datasets, and community input, the plan identifies key risks, including vegetation-related outages, high energy burden, and vulnerability among elderly and medically dependent populations. The SEP establishes three priority areas: hazard mitigation for energy infrastructure, outage safety and emergency readiness, and energy assistance and thermal safety. It outlines community-driven actions designed to complement utility-led system improvements, including targeted outreach, municipal coordination, and expanded access to energy programs. The plan also situates local conditions within broader state policy, market dynamics, and funding opportunities. Intended as a living document, this SEP provides a scalable framework for collaborative action to improve resilience, safety, and affordability in rural energy systems.

24 POWER TRANSMISSION AND DISTRIBUTION

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)

Hourly Electricity Demand Profiles for Each County in the Contiguous United States

This dataset provides estimated hourly electricity demand for each county in the contiguous United States from 2016-2023. The demand profiles represent the sum of two components: (1) Weighted averages of reported hourly demand profiles for North American Electric Reliability Corporation balancing authority (BA) regions and subregions, scaled to match annual estimates of county-level retail sales and direct use of electricity and weighted by the estimated percentage of county load served by each BA region or subregion. (2) Weighted averages of modeled hourly, county- and sector-level distributed photovoltaic (DPV) capacity factor profiles, scaled to match annual estimates of on-site consumption of DPV-generated electricity for each county and weighted by the percentage of consumption attributable to each sector Annual county-level retail sales are estimated by aggregating utility-reported sales to the state level and allocating the results to counties according to each county's share of state population. Annual county-level direct use is calculated by aggregating power plant-reported direct use values. Annual county-level on-site consumption of DPV-generated electricity is estimated by aggregating utility-reported net metering data to determine the amount of DPV-generated electricity sold back to the grid for each state, subtracting those values from modeled state-level DPV generation estimates, and allocating the results to counties according to each county's share of statewide modeled DPV generation. The open-source Python code used to develop this dataset is available at "Historical Load Data Repository" link below.

14 SOLAR ENERGY

Hydropower and environmental flow management: System-level trade-offs at Glen Canyon Dam

The research focuses on the Colorado River Basin, specifically examining the Glen Canyon Dam (GCD) and its influence on surrounding aquatic ecosystems. This area is crucial due to its role in hydropower production and its impact on downstream environments, including the Grand Canyon National Park. This study explores the integration of environmental factors into hydro dispatch modeling at GCD to tackle ecological challenges posed by the invasive smallmouth bass (SMB). Utilizing the GTMax SL and SERM models, the research assesses the effects of SMB control experiments on hydropower generation, economic value, and grid stability. The study examines the financial and economic impacts of bypass flows designed to release colder water to prevent SMB spawning, which can significantly reduce hydropower output and increase costs. The research identifies that declining reservoir levels and rising water temperatures in Lake Powell have facilitated SMB spawning, posing a threat to native fish populations like the endangered humpback chub. The findings highlight the importance of adaptive management strategies to balance ecological preservation with hydropower generation amid long-term weather-related challenges. The study underscores the need for comprehensive assessments of flow options to prevent SMB establishment below GCD, considering the broader implications for sediment dynamics and ecological interactions.

Ecological impact assessment

Typical Use Cases for Energy Storage in Rural Areas

Public power utilities and cooperatives play a crucial role in delivering reliable and affordable electricity to remote and sparsely populated regions. Unlike their urban counterparts, these utilities often face a unique set of challenges that can complicate their operations and service delivery. One of the primary challenges is the vast geographical area they must cover, which often results in higher transmission and distribution costs per customer. Additionally, public power utilities in rural areas often cannot afford the investments required to maintain and upgrade aging grid infrastructure to provide reliable and resilient power or withstand the impacts of recurring, severe weather events, which can cause extended outages and disrupt service delivery. Energy storage has emerged as a promising tool to help public power utilities meet these challenges. By enabling the storage of excess energy during low demand periods and providing a source of backup electricity during outages, energy storage systems can help utilities balance supply and demand more effectively. Additionally, they can help integrate a portfolio of various energy sources, reduce the need for expensive peak power purchases and provide ancillary services that stabilize the grid. This white paper describes potential use cases for energy storage in rural areas as well as documents a set of relevant example projects by project types.

24 POWER TRANSMISSION AND DISTRIBUTION

Changing windstorm characteristics over the US Northeast in a single model large ensemble

Abstract Extreme windstorms pose a significant hazard to infrastructure and public safety, particularly in the highly populated US Northeast (NE). However, the influence climate change and changing land use will have on these events remains unclear. A large ensemble generated using the Max-Planck Institute (MPI) Earth system model is used to generate projections of NE windstorms under different shared socioeconomic pathways (SSPs) and to attribute changes to projected land use land cover (LULC) change, externally forced changes and internal climate variability. To reduce the influence of coarse grid cell resolution and uncertainties in surface roughness lengths, windstorms are identified using simultaneous widespread exceedance of local 99th percentile 10 m wind speeds (U 99 ). Projected declines in forest cover in the NE and the resulting reductions in surface roughness length under SSP3-7.0 lead to projections of large increases in U 99 and derived windstorm intensity and scale. However, these projected changes in regional LULC under SSP3-7.0 are unprecedented in a historical context and may not be realistic. After corrections are applied to remove the influence of LULC on wind speeds, regionally averaged U 99 exhibit declines for most of the single model initial-condition large ensemble (SMILE) members which are broadly proportional to the radiative forcing and global air temperature increase in the SSPs, with a median value of −0.15 ms −1 °C −1 . While weak cyclones are projected to decline in frequency in the NE, intense cyclones and the resulting windstorms and indices of socioeconomic loss do not. Where present, significant trends in these loss indices are positive, and some MPI SMILE members generate future windstorms that are unprecedented in the historical period.

Coburn, Jacob (ORCID:0000000309538117)

Evaluation of Autoconversion Representation in E3SMv2 Using an Ensemble of Large-Eddy Simulations of Low-Level Warm Clouds

In numerical atmospheric models that treat cloud and rain droplet populations as separate condensate categories, precipitation initiation in warm clouds is often represented by an autoconversion rate (Au), which is the rate of formation of new rain droplets through the collisions of cloud droplets. Being a function of the cloud droplet size distribution (DSD), the local Au is commonly parameterized as a function of DSD moments: cloud droplet number (n c ) and mass (q c ) concentrations. When applied in a large-scale model, the grid-mean Au must also include a correction, or enhancement factor, to account for the horizontal variability of the cloud properties across the model grid. In this study, we evaluate the Au representation in the Energy Exascale Earth System Model version 2 (E3SMv2) climate model using large-eddy simulations (LES), which explicitly resolve cloud droplet spectra, and therefore the local Au, as well as its spatial variability. The analysis of an ensemble of warm low-level cloud cases shows that the E3SMv2 formulation represents the Au reasonably well compared to the horizontally averaged explicitly computed rate from LES. The agreement, however, comes from a combination of an underestimated E3SM-tuned local Au rate and an overestimated subgrid cloud variability enhancement factor. The latter bias is traced to neglecting the horizontal variability of n c and its co-variability with q c in parameterizing the grid-mean Au.

54 ENVIRONMENTAL SCIENCES

High-resolution modeling of indoor radon exposure with uncertainty quantification in Utah

Indoor radon accounts for 37% of population-level exposure to ionizing radiation in the United States. However, radon metrics are typically reported at coarse spatial scales, potentially obscuring meaningful local variation. We developed a high-resolution modeling framework to estimate indoor radon concentrations across Utah while explicitly quantifying predictive uncertainty. A total of 19,497 residential radon measurements collected between 2006 and 2017 were combined with environmental and housing characteristics and analyzed using a geospatial neural network that accommodates spatial dependence and nonlinear associations. Predictions were generated on a uniform hexagonal grid at 0.73 km2 resolution (H3 level 8). Out-of-sample predictions aggregated to the H3 level 8 grid showed good agreement with observed concentrations (Pearson r=0.64), while household-level predictions exhibited more moderate agreement (r=0.45). The model produced well-calibrated uncertainty estimates, with 24.1% of held-out observations exceeding the predicted 75th-percentile threshold. Maps of predicted radon concentrations and the probability of exceeding the U.S. EPA action level of 148 Bq/m3 (4 pCi/L) revealed substantial fine-scale spatial heterogeneity that was not apparent in conventional coarse-resolution summaries, with greater local variability observed in densely monitored urban counties than in sparsely sampled regions. High-resolution radon models that explicitly quantify uncertainty provide a useful framework for characterizing the spatial distribution of indoor radon and identifying areas of elevated exceedance risk. These findings highlight the value of fine-scale monitoring data and uncertainty-aware modeling approaches for radon exposure assessment, environmental risk characterization, and radon-related health research.

Wu, Yunhan [ORNL] (ORCID:0000000178842994)

Future Spatially Explicit Patterns of Land Transitions in the United States With Multiple Stressors

Climate change, income and population growth, and changing diets are major drivers of the global food system with implications for land use change. Land use in the U.S. will be affected directly by local and regional forces and indirectly through international trade. In order to investigate the effects of several potential forces on land use changes in the U.S., we advanced capabilities in representing the interactions between natural and human systems by linking a multisectoral and multiregional socio-economic model of the world economy to a model that downscales land use to a 0.5°grid scale. This enables us to translate regional projections of future land use into higher-resolution representations of time-evolving land cover (effectively spatially explicit land use transitions). We applied the framework over the U.S., with a particular interest in the Mississippi River Basin and its four sub-basins, to consider how a range of global drivers affect land use and cover in the target regions. Our results show that under scenarios of high pressure on the world food system a comparative advantage in livestock production amplifies the recent trend toward less cropland and more pastures in the U.S. Under low pressures on the world food system agricultural land is used less intensively. However, there can be key differences among the various land-use transitions at the sub- basin scale. Overall, these results highlighted the need for high resolution details to explicitly understand the implications of land use change on environmental impacts such as carbon storage, soil erosion, chemical use, hydrology, and water quality.

54 ENVIRONMENTAL SCIENCES

Solar and battery can reduce energy costs and provide affordable outage backup for US households

Distributed energy resources are promising solutions for household energy affordability and resilience as weather extremes and aging infrastructure intensify grid reliability risks. This study presents a comprehensive nationwide assessment of over 500,000 U.S. households, evaluating economic and backup viability of solar-battery systems. We find that 60% of households could reduce electricity costs with average savings of 15%, while 63% of households could achieve affordable backup power during power outages covering an average of 51% of their essential energy needs. However, these benefits show limited alignment with areas of greatest need, particularly in regions facing high outage risks. We also identify significant disparities in access to solar and battery, with less-populated and disadvantaged communities showing consistently lower viability. Furthermore, these findings demonstrate the need for targeted policy interventions to ensure equitable access to solar-battery benefits, especially as states transition from net energy metering to other electricity tariff policies.

14 SOLAR ENERGY

Cool rooms for indoor heat resilience: Evaluating affordable cooling strategies in heat-stressed California homes

Extreme heat conditions pose significant indoor survivability challenges for resource-constrained communities, which often lack access to cooling, have poorly insulated homes, and face compounding socioeconomic vulnerabilities. Moreover, concurrent power outages worsen health risks and heat-related illnesses. It is therefore crucial to develop innovative and affordable cooling approaches to protect vulnerable populations. This study assesses the efficacy of “cool rooms”– a designated space within a home equipped with passive and low-power active cooling measures to maintain safe indoor temperatures during extreme heat events and power disruptions. Using a physics-based building energy modeling approach, we evaluate the efficacy of various retrofit packages in maintaining thermal safety within the cool room under recent extreme heat conditions. The results indicate that passive measures can reduce 64% of hours with unmet standard effective temperatures, while the combination of passive and low-power active measures with built-in batteries further cuts this to 86%. Nevertheless, these strategies remain insufficient to maintain indoor thermal safety during extended outages. In contrast, integrating a solar-powered mini-split heat pump, whose technical potential was evaluated in this study, reduces indoor air temperatures below the 28 °C overheating threshold and significantly improves indoor habitability. The localized cool room strategy also offers potential for grid resilience by reducing peak electricity demand by up to 70% compared to whole house cooling during heat waves. The findings can inform the development of actionable heat mitigation plans and retrofit policies for residential communities with relatively low adoption of air conditioning such as warm marine climates.

Cool room