Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid impact analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Benchmarking the PCMCI Causal Discovery Algorithm for Spatiotemporal Systems

Causal discovery algorithms construct hypothesized causal graphs that depict causal dependencies among variables in observational data. While powerful, the accuracy of these algorithms is highly sensitive to the underlying dynamics of the system in ways that have not been fully characterized in the literature. In this report, we benchmark the PCMCI causal discovery algorithm in its application to gridded spatiotemporal systems. Effectively computing grid-level causal graphs on large grids will enable analysis of the causal impacts of transient and mobile spatial phenomena in large systems, such as the Earth’s climate. We evaluate the performance of PCMCI with a set of structural causal models, using simulated spatial vector autoregressive processes in one- and two-dimensions. We develop computational and analytical tools for characterizing these processes and their associated causal graphs. Our findings suggest that direct application of PCMCI is not suitable for the analysis of dynamical spatiotemporal gridded systems, such as climatological data, without significant preprocessing and downscaling of the data. PCMCI requires unrealistic sample sizes to achieve acceptable performance on even modestly sized problems and suffers from a notable curse of dimensionality. This work suggests that, even under generous structural assumptions, significant additional algorithmic improvements are needed before causal discovery algorithms can be reliably applied to grid-level outputs of earth system models.

54 ENVIRONMENTAL SCIENCES↗

An Analysis of Post Attack Impacts and Effects of Learning Parameters on Vulnerability Assessment of Power Grid

Due to the increasing number of heterogeneous devices connected to electric power grid, the attack surface increases the threat actors. Game theory and machine learning are being used to study the power system failures caused by external manipulation. Most of existing works in the literature focus on one-shot process of attacks and fail to show the dynamic evolution of the defense strategy. In this paper, we focus on an adversarial multistage sequential game between the adversaries of the smart electric power transmission and distribution system. We study the impact of exploration rate and convergence of the attack strategies (sequences of action that creates large scale blackout based on the system capacity) based on the reinforcement learning approach. We also illustrate how the learned attack actions disrupt the normal operation of the grid by creating transmission line outages, bus voltage violations, and generation loss. This simulation studies are conducted on IEEE 9 and 39 bus systems. The results show the improvement of the defense strategy through the learning process. The results also prove the feasibility of the learned attack actions by replicating the disturbances created in simulated power system.

attack impacts↗

Equipment Assessment Guide: A Technical Inspection and Hardening Guide for Devices in Power Grid Operations

This Equipment Assessment Guide, developed by Idaho National Laboratory (INL), provides a comprehensive framework designed to enhance the security of operational technology (OT) devices within power grid operations. The guide outlines essential steps for asset owners to conduct technical inspections and harden vulnerable hardware and firmware components commonly found in embedded systems. It focuses on components frequently targeted by cyber threats, offering valuable identification techniques for locating and recognizing critical components on devices. Additionally, the guide presents recommended secure configurations aimed at minimizing exposure and reinforcing defenses, along with impact analysis that highlights the potential consequences for grid operations if components are compromised. By implementing the recommendations outlined in this guide, asset owners can significantly enhance their cybersecurity posture, reduce the attack surface of field-deployed devices, and improve the resilience of grid services against emerging cyber threats.

42 - ENGINEERING↗

(DG)2 (Distributed Generation for Distribution Grids) [SWR-18-63]

(DG)2 is an impact analysis tool for electrical utilities to perform spatio-temporal analysis with solar and battery energy storage systems. The purpose of the tool is to help distribution utilities with identifying impacts and costs associated with locating a MW-scale solar farm and energy storage system at a certain location over other choices. This tool also assists utilities to assess the amount of reverse power flow at the transmission lines.

Latif, Aadil↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

A practical control strategy for demand flexibility with ensured occupant comfort in grid-interactive efficient buildings

This study proposes a practical and simplified demand response (DR) control strategy from the perspective of grid-interactive efficient buildings (GEBs), aiming to secure demand flexibility while ensuring occupant thermal comfort. Focusing on summer on-peak periods, a linear demand response (LDR) strategy that integrates cooling setpoint adjustment and lighting dimming was designed, and its performance was quantitatively evaluated. A case study was conducted using EnergyPlus-based simulations for a U.S. DOE small office prototype building under summer on-peak weather conditions. Compared with a conventional rapid demand response (RDR) strategy, the proposed LDR approach gradually reduced electrical loads while maintaining occupant thermal comfort indices, including predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), within acceptable comfort ranges. Quantitative analysis of demand flexibility using the grid-interactive impact index (GII) and the flexibility strength index (FSI) showed that the LDR strategy provided approximately 12.5% demand flexibility during DR periods and achieved an electricity cost reduction of about 8.8%. In addition, the results of the part-load ratio (PLR)-based cooling system performance analysis showed that, in the on-peak period, the LDR strategy exhibited improved cooling performance compared with the baseline. Overall, this study shows the potential of a practical DR control strategy that can simultaneously achieve occupant comfort and demand flexibility without relying on complex advanced control technologies.

Jung, Dong Eun↗

Virtual Dynamic Grid Impedance and Its Impacts on Harmonics and Stability of Inverter Based Resources Plant

Nowadays, a large number of inverter-based resources (IBRs) are integrated into the grid at a single connection point as an IBR plant. In this article, a virtual dynamic grid impedance concept is introduced to evaluate the harmonics and stability for grid integration of an IBR plant containing multiple IBRs. First, a detailed theoretical study is conducted to build a foundation of the virtual grid impedance concept, which is a dynamic impedance that changes with the number of IBRs added into an IBR plant. Then, based on the new virtual dynamic grid impedance concept, frequency spectrum analysis is performed to explore harmonic impact at the interconnection point for an IBR plant with IBRs having L, LC, and LCL filters, respectively. An electromagnetic transient (EMT) simulation model of a grid-connected IBR plant is developed to explore the harmonics and stability of the IBR plant connected to the grid as well as the reliable operation of IBRs within the plant from the novel virtual equivalent dynamic grid impedance point of view. Hardware experiments are conducted to validate the EMT simulation evaluation. The results show that the number of IBRs added into an IBR plant influences the grid impedance, i.e., grid strength, and the grid impedance variation has multiple impacts on the IBR plant and IBRs within the plant depending on the grid-connected filters of the IBRs.

grid impedance↗

Modeling Framework for Bulk Electric Grid Impacts from HEMP E1 and E3 Effects (Tasks 3.1 Final Report)

This report presents a framework to evaluate the impact of a high-altitude electromagnetic pulse (HEMP) event on a bulk electric power grid. This report limits itself to modeling the impact of EMP E1 and E3 components. The co-simulation of E1 and E3 is presented in detail, and the focus of the paper is on the framework rather than actual results. This approach is highly conservative as E1 and E3 are not maximized with the same event characteristics and may only slightly overlap. The actual results shown in this report are based on a synthetic grid with synthetic data and a limited exemplary EMP model. The framework presented can be leveraged and used to analyze the impact of other threat scenarios, both manmade and natural disasters. This report d escribes a Monte-Carlo based methodology to probabilistically quantify the transient response of the power grid to a HEMP event. The approach uses multiple fundamental steps to characterize the system response to HEMP events, focused on the E1 and E3 components of the event. 1) Obtain component failure data related to HEMP events testing of components and creating component failure models. Use the component failure model to create component failure conditional probability density function (PDF) that is a function of the HEMP induced terminal voltage. 2) Model HEMP scenarios and calculate the E1 coupled voltage profiles seen by all system components. Model the same HEMP scenarios and calculate the transformer reactive power consumption profiles due to E3. 3) Sample each component failure PDF to determine which grid components will fail, due to the E1 voltage spike, for each scenario. 4) Perform dynamic simulations that incorporate the predicted component failures from E1 and reactive power consumption at each transformer affected by E3. These simulations allow for secondary transients to affect the relays/protection remaining in service which can lead to cascading outages. 5) Identify the locations and amount of load lost for each scenario through grid dynamic simulation. This can be an indication of the immediate grid impacts from a HEMP event. In addition, perform more detailed analysis to determine critical nodes and system trends. 6) To help realize the longer-term impacts, a security constrained alternating current optimal power flow (ACOPF) is run to maximize critical load served. This report describes a modeling framework to assess the systemic grid impacts due to a HEMP event. This stochastic simulation framework generates a large amount of data for each Monte Carlo replication, including HEMP location and characteristics, relay and component failures, E3 GIC profiles, cascading dynamics including voltage and frequency over time, and final system state. This data can then be analyzed to identify trends, e.g., unique system behavior modes or critical components whose failure is more likely to cause serious systemic effects. The proposed analysis process is demonstrated on a representative system. In order to draw realistic conclusions of the impact of a HEMP event on the grid, a significant amount of work remains with respect to modeling the impact on various grid components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis and Technology Needs for Getting to 100% Renewable Energy: Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100) Example

The presentation outlines the energy sector impacts of Hurricane's Irma and Maria in Puerto Rico, followed by the analysis and technology needs for getting to 100% renewable energy with an overview of the Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (i.e., PR 100 Study).

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

A Methodology for Evaluating Operator Usage of Machine Learning Recommendations for Power Grid Contingency Analysis

This work presents the application of a methodology to measure domain expert trust and workload, elicit feedback, and understand the technological usability and impact when a machine learning assistant is introduced into contingency analysis for real-time power grid simulation. The goal of this framework is to rapidly collect and analyze a broad variety of human factors data in order to accelerate the development and evaluation loop for deploying machine learning applications. We describe our methodology and analysis, and we discuss insights gained from a pilot participant about the current usability state of an early technology readiness level (TRL) artificial neural network (ANN) recommender.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of a Disturbance Event with Inverter-Based Resources Using EMT Simulations

Increasing penetration of inverter-based resources (IBRs) necessitates newer methods of planning and analysis of disturbances. The existing phasor-domain transient stability (TS) analysis may not capture the dynamics of IBRs during fault events. Here, in this paper, electromagnetic transient (EMT) simulations using high-fidelity detailed model of power grid and one of the affected photovoltaic (PV) plants during the Angeles Forest disturbance in 2018 are performed. In these simulations, the processes to develop EMT models of power grid from traditional phasor-domain TS data and PV plant from collected data are described. Thereafter, using these simulations, the response of the PV plant during the fault event in 2018 is replicated and a sensitivity analysis is performed. The sensitivity analysis consists of making changes to the components within the PV plant and in the power grid to evaluate the impact they have on the response observed by the PV plant during the fault event. This analysis provides an understanding of the components that impact the operation of a PV plant during fault events and provide guidance to system planners on the studies that need to be performed to maintain a reliable power grid as new IBR plants are integrated.

42 ENGINEERING↗

Scaled Implementation of Smart Charge Management for Electric Vehicles

Smart charge management (SCM) has become a critical strategy for mitigating potential grid impacts and reducing electricity costs for all customers. This study will evaluate the economics of implementing light-duty EV SCM at scale across the United States. This work will enhance distribution system analysis by estimating SCM implementation costs, exploring viable business cases, and developing a framework for national-level applications. The primary methodology involves leveraging detailed grid modeling from a specific service territory and using spatial extrapolation techniques to generalize findings to other regions. The analysis will develop key metrics to quantify the costs and benefits of SCM, including implementation costs relative to strategy and scale, the cost of distribution system upgrades with and without SCM, and the percentage of peak-load reduction. The objective is to produce a comprehensive report and a parameterized framework that enables utilities to self-assess the value of SCM in their own service territories. This will support the development of cost-effective charging strategies, accelerate the energization of new EV chargers, and facilitate the seamless integration of EVs into the nation's power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Analysis of Data-Driven and Transactive Approaches for Resilience Enhancement

As extreme weather events lead to more frequent power outages, understanding and enhancing grid resilience is critical to mitigating economic losses and non-energy impacts from service disruptions. Here, this study introduces a novel techno-economic analysis framework for evaluating resilience enhancement mechanisms. The framework combines grid response modeling with a co-simulation approach and valuation methodology to provide a comprehensive assessment. We apply this framework to a realistic case study of the Texas grid during Winter Storm Uri in February 2021. Two advanced resilience strategies are analyzed: a data-driven rolling outage mechanism and a transactive energy (TE) based allocation scheme. The rolling outage scheme selectively serves customers based on real-time curtailment needs, while the TE scheme allows customers to trade energy allocations according to their preferences. Our findings show that both the rolling outage and TE schemes significantly outperform conventional methods (i.e. controlled outages) by reducing the amount of energy not supplied to customers by 41% and 64%, respectively. These approaches also enhance flexibility and customer satisfaction, while improving energy utilization for greater resilience. Additionally, they maintain thermal comfort about 3.5 times better and substantially lower customer risk exposure. A key contribution of this study is addressing both utility and customer perspectives while considering both energy and non-energy impacts. The techno-economic analysis indicates that implementing these resilience enhancement strategies would incur an additional 1.1Bto1.6B in utility costs but has the potential to avoid 17.3Bto18B of customer losses as compared to existing solutions, thereby underscoring the value of investing in advanced resilience, as it provides significant societal benefits to customers.

42 ENGINEERING↗

Location Selection of Fast-Charging Station for Heavy-Duty EVs Using GIS and Grid Analysis: Preprint

This work presents a systematic methodology for the location selection of fast-charging stations for heavy-duty Electric Vehicles (EVs) based on both geospatial and electrical grid analysis. The geo-spatial analysis is based on real-world geographic information system (GIS) data of road networks and existing supportive infrastructures. The grid analysis is implemented based on node level analysis of potential impacts on voltages and power losses in distribution system. A case study using realistic three-phase unbalanced distribution feeder from California and extracted real-world GIS data is used to demonstrate the intuitiveness and effectiveness of the proposed methodology for the location selection of fast charging station for heavy duty EVs.

47 OTHER INSTRUMENTATION↗

Leading Energy Analysis: Data-Driven Insights That Power Our Energy Future

Energy analysts at the National Renewable Energy Laboratory (NREL) use a broad set of expertise and cutting-edge tools to capture the complexities of our interconnected energy system. Decision-makers rely on these insights to drive cost savings, enhance grid reliability, support long-term innovation, and bolster America's energy workforce and global competitiveness. This fact sheet highlights some of NREL's high-impact analyses, data, and tools, largely focusing on power grid analysis.

data↗

CEC Quest: Long Duration Energy Storage Impact Analysis Tool

SAND2025-14389O CEC Quest is a Python tool with a user interface designed to analyze the greenhouse gas impacts of long-duration energy storage projects in California. The tool automates data collection from public sources and uses an Application Programming Interface (API) to enable users to download photovoltaic resource availability, marginal operating emissions rate, and utility rate data. It guides users in inputting parameters for a battery energy storage model and uploading site electrical load data, while also prompting for relevant analysis parameters like timestep and grid limits. CEC Quest performs monthly optimization of one year of data to assess impacts on the site’s electrical bill and the grid’s greenhouse gas emissions. Finally, it conducts a lifecycle analysis to evaluate changes over a defined quantification period, with results aggregated through automated report generation. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Rosewater, David [Sandia National Lab. (SNL-CA), L↗

Grid Modeling and Hosting Capacity Analysis

An interface with the OpenDSS distribution grid simulator, facilitating users in calibrating and validating models. Additionally, three distinct tools have been developed: PV Hosting Capacity: This tool allows users to determine the additional amount of photovoltaic (PV) generation that can be integrated into the system without breaching operational constraints. EV Hosting Capacity: This tool focuses on identifying the capacity for incorporating extra electric vehicle (EV) load into the system without surpassing operational limitations. Project Impact Analysis Tool: This tool is designed to assess and report all potential grid violations associated with a specific project, providing valuable insights into its impact on the distribution grid.

Poudel, Shiva↗