Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid energy storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Grid regulation services for energy storage devices based on grid frequency

Disclosed herein are representative embodiments of methods, apparatus, and systems for charging and discharging an energy storage device connected to an electrical power distribution system. In one exemplary embodiment, a controller monitors electrical characteristics of an electrical power distribution system and provides an output to a bi-directional charger causing the charger to charge or discharge an energy storage device (e.g., a battery in a plug-in hybrid electric vehicle (PHEV)). The controller can help stabilize the electrical power distribution system by increasing the charging rate when there is excess power in the electrical power distribution system (e.g., when the frequency of an AC power grid exceeds an average value), or by discharging power from the energy storage device to stabilize the grid when there is a shortage of power in the electrical power distribution system (e.g., when the frequency of an AC power grid is below an average value).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Zinc batteries for grid-scale energy storage: Challenges, opportunities, and future directions

The global electricity sector is undergoing rapid transformation, increasing demand for reliable stationary energy storage and intensifying the need for safe, cost-effective, and scalable technologies for grid-scale applications. While lithium-ion batteries currently dominate the market, concerns over cost, safety, and resource availability motivate the exploration of alternative chemistries. Zinc-based batteries have emerged as a promising option due to the abundance, low cost, and wide geographic distribution of zinc, combined with the inherent safety of aqueous electrolytes. This perspective examines the potential of zinc batteries for stationary energy storage, with particular focus on rechargeable zinc-air systems. We discuss the evolution of zinc battery technologies and compare zinc-air, zinc-bromine, nickel-zinc, and aqueous zinc-ion chemistries, highlighting their advantages for grid applications. Key challenges limiting rechargeable zinc battery performance are analyzed, including dendrite formation and corrosion at the zinc anode, electrolyte degradation from carbonation and evaporation, and sluggish oxygen electrocatalysis at the air cathode. Emerging strategies to address these limitations are reviewed, including advanced electrode architectures, electrolyte engineering, catalyst development, and system-level design improvements. Lastly, we outline future research directions and opportunities for developing durable, efficient, and economically viable zinc-based energy storage systems for grid-scale applications.

Aqueous electrolytes↗

Modeling and Optimization Methods for Controlling and Sizing Grid-connected Energy Storage: A Review

Purpose of Review Energy storage is capable of providing a variety of services and solving a multitude of issues in today's rapidly evolving electric power grid. This paper reviews recent research on modeling and optimization methods for optimally controlling and sizing grid-connected battery energy storage systems (BESSs). Open issues and promising research directions are discussed. Recent Findings Recent studies on BESS dispatch, evaluation, and sizing focus on advanced modeling and optimization methods to maximize stacked value streams from multiple services. BESS models have been improved to better represent operational characteristics or capture degradation effects. Different solution methods and optimization techniques have been proposed to improve the benefits and cost-effectiveness of BESSs, using deterministic approaches prevalently but with impressive progress in capturing and addressing uncertainties. Summary Recent progress in BESS scheduling and sizing better supports planning and operational decision-making in different use cases, which is highly important to advance the deployment of BESSs. Additional research is required to properly model the trade-off between short-term benefits and service life with multiple degradation effects explicitly considered in the decision-making process. Advanced methods are to be developed for effectively determining optimal BESS sizes that maximize overall benefits within a varying lifetime considering diversified system, conditions as well as uncertainties at planning and operational stages.

Wu, Di↗

Lithium-Ion Battery Design for Grid-Scale Energy Storage App

A software that delivers parameters from energy storage system (ESS) to container, rack, module and single cell design, as well as data analysis on arbitrage energy and frequency regulation of ESS in different regions, has been developed. The Lithium-ion Battery Design for Grid-scale Energy Storage App V1.0 has the capability to output the system, module and cell design with the energy, power, capacity, group method, cost of single cell, and single cell test protocol which break down from input energy storage system data in different regions. The default chemistry of the battery is LiFePO4 and graphite. The energy density of the graphite/LiFePO 4 pouch cell ranges from 100 Wh/kg to 200 Wh/Kg in the software. Graphite/LiFePO 4 pouch cell (up to 1Ah in lab) manufacturing line is also built and can be used to evaluate the test protocol, moreover, for electrolyte evaluation in other ESMI seedling projects. The software enables rapid prototyping to accelerate energy storage research, development, and manufacturing.

Liu, Dianying↗

Control co-design under uncertainty for offshore wind farms: Optimizing grid integration, energy storage, and market participation

Offshore wind farms (OWFs) are set to significantly contribute to global decarbonization efforts. Developers often use a sequential approach to optimize design variables and market participation for grid-integrated offshore wind farms. However, this method can lead to sub-optimal system performance, and uncertainties associated with renewable resources are often overlooked in decision-making. Here, this paper proposes a control co-design approach, optimizing design and control decisions for integrating OWFs into the power grid while considering energy market and primary frequency market participation. Additionally, we introduce optimal sizing solutions for energy storage systems deployed onshore to enhance revenue for OWF developers over time. This framework addresses uncertainties related to wind resources and energy prices. We analyze five U.S. west-coast offshore wind farm locations and potential interconnection points, as identified by the Bureau of Ocean Energy Management (BOEM). Results show that optimized control co-design solutions can increase market revenue by 3.2% and provide flexibility in managing wind resource uncertainties.

Control Co-design↗

USAID Grid-Scale Energy Storage Technologies Primer

This work provides an overview and compares key operating characteristics of select energy storage technologies. This work explores how these storage technologies may be used to improve the flexibility and reliability of power systems given their technical characteristics. The report covers various electrochemical (lithium-ion, lead-acid, flow, sodium-sulfur), chemical (hydrogen), mechanical (pumped hydro storage, compressed air energy storage, flywheels, gravity) and electrical (supercapacitors) storage mediums.

25 ENERGY STORAGE↗

Battery Performance, Thermal, and Life Modeling for Southern California Edison (Cooperative Research and Development Final Report)

The objective of this project is to develop battery performance models, thermal models and life models for SCE to use in simulation and analysis of grid services involving energy storage. NREL will fit the models to three separate chemistries using test data provided by SCE. The dataset for each chemistry will include electrical, thermal and aging response to different temperatures and cycling conditions, measured under a variety of cell-level and module-level experiments described in SCE test protocol documents. Once tuned to a test dataset, the battery system model software will provide predictions of battery energy and power loss, and thus cycle and calendar life, for any energy storage grid service power profile of interest to SCE. The automated battery life modeling and simulation tool can also be applied to any other grid battery systems as long as necessary input data is available to accelerate battery model development and battery lifetime analysis.

25 ENERGY STORAGE↗

Reaction heterogeneity in practical high-energy lithium–sulfur pouch cells

The lithium–sulfur (Li–S) battery is a promising next-generation energy storage technology because of its high theoretical energy and low cost. Extensive research efforts have been made on new materials and advanced characterization techniques for mechanistic studies. However, it is uncertain how discoveries made on the material level apply to realistic batteries due to limited analysis and characterization of real high-energy cells, such as pouch cells. Evaluation of pouch cells (>1 A h) (instead of coin cells) that are scalable to practical cells provides a critical understanding of current limitations which enables the proposal of strategies and solutions for further performance improvement. Herein, we design and fabricate pouch cells over 300 W h kg -1 , compare the cell parameters required for high-energy pouch cells, and investigate the reaction processes and their correlation to cell cycling behavior and failure mechanisms. Spatially resolved characterization techniques and fluid-flow simulation reveal the impacts of the liquid electrolyte diffusion within the pouch cells. We found that catastrophic failure of high-energy Li–S pouch cells results from uneven sulfur/polysulfide reactions and electrolyte depletion for the first tens of cycles, rather than sulfur dissolution as commonly reported in the literature. The uneven reaction stems from limited electrolyte diffusion through the porous channels into the central part of thick cathodes during cycling, which is amplified both across the sulfur electrodes and within the same electrode plane. A combination of strategies is suggested to increase sulfur utilization, improve nanoarchitectures for electrolyte diffusion and reduce consumption of the electrolytes and additives.

25 ENERGY STORAGE↗

Cyber-Resilient Frequency Control of Power Grids with Energy Storage Systems

The integration of synchronous generators and energy storage systems operated through communication networks introduces new challenges and vulnerabilities to the electric grid, where cyber attacks can corrupt sensor measurements or control inputs and interrupt functions such as frequency regulation. This paper proposes a defense methodology for the design of resilient operating constraints imposed on each generation and storage unit in order to prevent any attack sequence from driving the system's frequency to unsafe conditions. The resilient operating constraints are found by using ellipsoidal approximations of the reachable set of the power system, leading to a convex optimization problem with linear matrix inequalities. Numerical results in a single-area power system with synchronous generation and energy storage demonstrate how the resilient constraints provide security guarantees against any type of attack affecting frequency measurements or controller setpoints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rechargeable alkaline zinc–manganese oxide batteries for grid storage: Mechanisms, challenges and developments

Rechargeable alkaline Zn–MnO 2 (RAM) batteries are a promising candidate for grid-scale energy storage owing to their high theoretical energy density rivaling lithium-ion systems (~400 Wh/L), relatively safe aqueous electrolyte, established supply chain, and projected costs below $100/kWh at scale. In practice, however, many fundamental chemical and physical processes at both electrodes make it difficult to achieve commercially competitive energy density and cycle life. In this paper, we present a detailed and timely analysis of the constituent materials, current commercial status, electrode processes, and performance-limiting factors of RAM batteries. We also examine recently reported strategies in RAM and related systems to address these issues through additives and modifications to the electrode materials and electrolyte, special ion-selective separators and/or coatings, and unconventional cycling protocols. We conclude with a critical summary of these developments and discussion of how future studies should be focused toward the goal of energy-dense, scalable, and cost-effective RAM systems.

25 ENERGY STORAGE↗

Grid-scale Energy Storage Hazard Analysis & Design Objectives for System Safety

Battery based energy storage systems are becoming a critical part of a modernized, resilient power system. However, batteries have a unique combination of hazards that can make design and engineering of battery systems difficult. This report presents a systematic hazard analysis of a hypothetical, grid scale lithium-ion battery powerplant to produce sociotechnical "design objectives" for system safety. We applied system's theoretic process analysis (STPA) for the hazard analysis which is broken into four steps: purpose definition, modeling the safety control structure, identifying unsafe control actions, and identifying loss scenarios. The purpose of the analysis was defined as to prevent event outcomes that can result in loss of battery assets due to fires and explosions, loss of health or life due to battery fires and explosions, and loss of energy storage services due to non- operational battery assets. The STPA analysis resulted in identification of six loss scenarios, and their constituent unsafe control actions, which were used to define a series of design objectives that can be applied to reduce the likelihood and severity of thermal events in battery systems. These design objectives, in all or any subset, can be utilized by utilities and other industry stakeholders as "design requirements" in their storage request for proposals (RFPs) and for evaluation of proposals. Further, these design objectives can help to protect firefighters and bring a system back to full functionality after a thermal event. We also comment on the hazards of flow battery technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Emerging Soluble Organic Redox Materials for Next-Generation Grid Energy-Storage Applications

Soluble organic redox molecules have emerged as promising candidate active materials for multiple energy storage systems due to their structural versatility, fast redox process, high capacity storage, sustainability, and environmental friendliness. This review examines recent progress in developing such materials in green and sustainable batteries for grid applications and points out directions for future research.

Zhan, Xiaowen↗

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

Convex Relaxation of Grid-Connected Energy Storage System Models With Complementarity Constraints in DC OPF

Including complementarity constraints in energy storage system (ESS) models in optimization problems ensure an optimal solution will not produce a physically unrealizable control strategy where there is simultaneous charging and discharging. However, the current approaches to impose complementarity constraints require the use of non-convex optimization methods. Here, we propose a convex relaxation for a common ESS model that has terms for both charging and discharging based on a penalty reformulation for use in a model predictive control (MPC) based optimal power flow (DC OPF) problem. In this approach, the complementarity constraints are omitted and a penalty term is added to the optimization objective function. For the DC OPF problem, we provide analysis for the conditions under which the convex relaxation of the complementarity constraint ensures that a solution with simultaneous ESS charging and discharging operation is suboptimal. Simulation results demonstrating ESS behavior with and without the penalty reformulation are provided for an MPC-based DC OPF problem on multiple IEEE test systems.

25 ENERGY STORAGE↗