Very high X-ray efficiency from a blazed grating

The efficiency of X-ray diffraction from reflection gratings has been investigated experimentally using a gold-coated plane grating of 25 x 120 mm with a nominal blaze angle of 21 deg in a conical diffraction mount. Results show that conical diffraction is capable of producing very high dispersion efficiencies. The peak of first order at 13.3 A is 40%; at 44 A, the peak is 34%. The most immediate application of this result is to X-ray astronomy where sources are weak.

Cash, W.↗

The experimental computer control of a two-dimensional hyperbolic system

The experimental computer control of a two-dimensional hyperbolic system is described. The system consists of a 5-foot gold-coated rubber membrane mounted on a circular cylindrical drum. Seven electrodes reside on a command surface located behind the membrane inside the drum. These electrodes served as capacitive sensors and electrostatic force actuators of transverse membrane deflection. The membrane was modelled as flat, isotropic and uniformly tensioned. Transverse membrane deflections were expanded in normal modes. Controllers regulating membrane deflection are designed using aggregation and design procedures based upon sensor and actuator influence functions. The resulting control laws are implemented on a minicomputer in two sets of experiments. The experimental study confirms the theoretically predicted behavior of the system, usefulness of the aggregation and design procedures, and the expectation that spillover can be made a beneficial source of damping in residual systems.

Yam, Y.↗

New techniques for fusion bonding and replication for large glass reflectors

Lightweight, space-deployable glass honeycomb telescope primary mirror structures are produced by a novel method which involves the heating to softening temperature of many borosilicate or silica glass tube sections that are packed to form a honeycomb matrix and filled with a high expansion coefficient refractory sand. The close packed tubes yield a hexagonal-cell honeycomb. Attention is given to the results of an experiment in which a highly refractory master was used to shape a honeycomb of less refractory glass, employing a 1-micron thick, vacuum-deposited gold coating as a parting layer between the two.

Angel, J. R. P.↗

The LAMAR telescope module for high throughput imaging and spectroscopy

Kirkpatrick-Baez mirror assemblies for the LAMAR experiment of the Space Shuttle are described. The aperture is 20 cm x 30 cm and the distance from the front of the mirror to the focal plane is 3.4 m. The reflectors are made from 1.8 mm gold coated float glass. A prototype brassboard mirror was constructed with only one-third of the plates. Its angular resolution is 35 arcsec (HPW) in visible light. X-ray tests over small areas indicate very little scattering. The fabrication technique is applicable to larger mirror systems such as those of XMM. The use of flatter material for the reflectors results in better angular resolution.

Gorenstein, P.↗

X-ray telescope module for the LAMAR Space Shuttle experiment

The first of eight X-ray telescopes is under construction for the LAMAR experiment. Each consists of two orthogonal sets of nested confocal one-dimensional parabolic plates of gold-coated float glass, selected for flatness from commercial stock. Each is initially bent to a cylinder by bonding a thin, highly curved titanium sheet to its inactive surface. The final parabolic figure is produced by an automated system which includes seven diode arrays that detect a visible-light line image. Eight precise motorized linear translators operating under the control of a computer, tune the plate to the optimum figure. The plate is then fixed in position by epoxy bonds. The precision of the system is several arcsec, but the intrinsic flatness of the glass is expected to limit the half-power diameter (HPD) of the telescope to about 25 arcsec.

Gorenstein, P.↗

Noncontact true temperature measurement

A laser pyrometer has been developed for acquiring the true temperature of a levitated sample. The laser beam is first expanded to cover the entire cross-sectional surface of the target. For calibration of such a system, the reflectivity signal of an ideal 0.95 cm diameter gold-coated sphere (reflectivity = 0.99) is used as the reference for any other real targets. The emissivity of the real target can then be calculated. The overall system constant is obtained by passively measuring the radiance of a blackbody furnace (emissivity = 1.0) at a known, arbitrary temperature. Since the photo sensor used is highly linear over the entire operating temperature range, the true temperature of the target can then be computed. Preliminary results indicate that true temperatures thus obtained are in excellent correlation with thermocouple measured temperatures.

Lee, Mark C.↗

Degradation and crosslinking of perfluoroalkyl polyethers under X-ray irradiation in ultrahigh vacuum

Degradation of three types of commercially available perfluoroalkyl polyethers (PFPE)-Demnum S200, Fomblin Z25, and Krytox 16256-by X-ray irradiation was studied by using X-ray photoemission spectroscopy (XPS) and a mass spectrometer under ultra-high-vacuum conditions. The carbons in the polymers were characterized by chemical shifts of Cls binding energies. Gaseous products containing COF2 and low-molecular-weight fluorocarbons were formed. From Fomblin Z25, which has acetal linkages (-OCF2O-), a large quantity of COF2 gas was evolved. Liquid products became tacky after a long irradiation time, and some did not dissolve in Freon. High-pressure liquid chromatography (HPLC) showed that molecular weight distribution became broader and that higher molecular weight polymers were formed from Demnum and Krytox. We concluded from these results that degradation and cross-linking took place simultaneously. Demnum crosslinked more easily than the other fluids. The time dependence of both XPS spectra of Cls and mass spectra showed that C-O-bonded carbons in PFPE'S were removed faster than other carbons. There was no substrate effect on the degradation reaction because the first-order rate constants calculated from the change of gaseous products were similar when stainless steel (440C) and gold-coated surfaces were used. Metal fluorides were formed on stainless steel during the reaction. A mechanism for the degradation of PFPE'S is discussed on the basis of their molecular structures.

Mori, Shigeyuki↗

A Near-Infrared Mapping Spectrometer for investigation of Jupiter and its satellites

The Near-Infrared-Mapping Spectrometer (NIMS) is one of the science instruments in the Galileo mission, which will explore Jupiter and its satellites in the mid-1990's. The NIMS experiment will map geological units on the surfaces of the Jovian satellites and characterize their mineral content; and, for the atmosphere of Jupiter, investigate cloud properties and the spatial and temporal variability of molecular abundances. The optics are gold-coated reflective and consist of a telescope and a grating spectrometer. The balance of the instrument includes a 17-detector (silicon and indium antimonide) focal plane array, a tuning fork chopper, microprocessor-controlled electronics, and a passive radiative cooler. A wobbling secondary mirror in the telescope provides 20 pixels in one dimension of spatial scanning in a pushbroom mode with 0.5 mr x 0.5 mr instantaneous field of view. The spectral range is 0.7-5.2 microns; resolution is 0.025 micron. NIMS is the first infrared experiment to combine both spatial and spectral mapping capability in one instrument.

Aptaker, Irving M.↗

FIRAS wire grid characterization techniques

Characterization techniques used to verify the quality and spectral performance of the large freestanding wire grid polarizing beamsplitters and input/output polarizers used in the Far Infrared Absolute Spectrophotometer (FIRAS) are presented. The clear aperture of these grids is lined with 20.8 micron diameter gold coated tungsten wire, spaced 33 microns apart. The grid characteristics measured throughout fabrication and space flight qualification are the center to center wire spacing and wire plane flatness. Ideally, the wire grids should produce coherent wavefronts with equal reflectance and transmittance properties. When the spacing is inconsistent, these wavefront intensities are unequal, thus decreasing the efficiency of the grids and reducing the output signal of the FIRAS. The magnitude of the output interferogram is also reduced by incoherence in the interfering wave fronts caused by uneven flatness.

Barney, Richard D.↗

Hydrocarbon-fuel/copper combustion chamber liner compatibility, corrosion prevention, and refurbishment

An evaluation is made of combustion product/combustion chamber compatibility in the case of a LOX/liquid hydrocarbon booster engine based on copper-alloy thrust chamber which is regeneratively cooled by the fuel. It is found that sulfur impurities in the fuel are the primary causes of copper corrosion, through formation of Cu2S; sulfur levels as low as 1 ppm can result in sufficiently severe copper corrosion to degrade cooling channel performance. This corrosion can be completely eliminated, however, through the incorporation of an electrodeposited gold coating on the copper cooling-channel walls.

Rosenberg, S. D.↗

Scalable diode array pumped Nd rod laser

Experiments were carried out on a five-array pump head which utilizes gold-coated reflective cones to couple the pump energy to Nd:YAG and Nd:YLF rod lasers, demonstrating high efficiency and uniform energy deposition. Because the cones function as optical diodes to light outside their acceptance angle (typically 10-15 deg), much of the diode energy not absorbed on the first pass can be returned to the rod.

Zenzie, H. H.↗

Cryogenic far-infrared Fabry-Perot etalon

A small cryogenic Fabry-Perot etalon was fabricated for the far-infrared region. The design used freestanding metal meshes for the reflecting elements. Using a combination of gold-coated copper mesh on stainless steel. The spacing is reproduced to 1 part in 10 exp 6 with repeated cooling. The properties and methods used for alignment and calibration are presented.

Peterson, D. B.↗

Recording Rapidly Changing Cylinder-wall Temperatures

The present report deals with the design and testing of a measuring plug suggested by H. Pfriem for recording quasi-stationary cylinder wall temperatures. The new device is a resistance thermometer, the temperature-susceptible part of which consists of a gold coating applied by evaporation under high vacuum and electrolytically strengthened. After overcoming initial difficulties, calibration of plugs up to and beyond 400 degrees C was possible. The measurements were made on high-speed internal combustion engines. The increasing effect of carbon deposit at the wall surface with increasing operating period is indicated by means of charts.

Meier, Adolph↗

Low velocity nucleate flow boiling at various orientations

Subcooled forced convection nucleate boiling experiments with R-113 were conducted at low velocities using both thin film semi-transparent gold on quartz and gold coated cooper substrate flat heaters at varying orientations. The results are intended to assist in understanding effects of buoyancy in forced convection boiling and in better defining requirements for studying flow boiling in the microgravity environment of space. Measurements of the heat flux and the surface superheat were made at three levels of subcooling from 2.2 C to 11.1 C, four bulk velocities from 4.1 cm/s to 32.4 cm/s and various orientations spanning 360 deg. The experiments demonstrate that if buoyancy is significant reative to bulk liquid momentum, then a decrease in the buoyant force normal and away from the heater surface enhances the heat transfer, with the effect being most prominent at low values of heat flux. Furthermore, the effect of velocity is shown to be dependent on the surface orientation.

Kirk, Kevin M.↗

Micro-Mechanical Voltage Tunable Fabry-Perot Filters Formed in (111) Silicon

The MEMS (Micro-Electro-Mechanical-Systems) technology is quickly evolving as a viable means to combine micro-mechanical and micro-optical elements on the same chip. One MEMS technology that has recently gained attention by the research community is the micro-mechanical Fabry-Perot optical filter. A MEMS based Fabry-Perot consists of a vertically integrated structure composed of two mirrors separated by an air gap. Wavelength tuning is achieved by applying a bias between the two mirrors resulting in an attractive electrostatic force which pulls the mirrors closer. In this work, we present a new micro-mechanical Fabry-Perot structure which is simple to fabricate and is integratable with low cost silicon photodetectors and transistors. The structure consists of a movable gold coated oxide cantilever for the top mirror and a stationary Au/Ni plated silicon bottom mirror. The fabrication process is single mask level, self aligned, and requires only one grown or deposited layer. Undercutting of the oxide cantilever is carried out by a combination of RIE and anisotropic KOH etching of the (111) silicon substrate. Metallization of the mirrors is provided by thermal evaporation and electroplating. The optical and electrical characteristics of the fabricated devices were studied and show promissing results. A wavelength shift of 120nm with 53V applied bias was demonstrated by one device geometry using 6.27 micrometer air gap. The finesse of the structure was 2.4. Modulation bandwidths ranging from 91KHz to greater than 920KHz were also observed. Theoretical calculations show that if mirror reflectivity, smoothness, and parallelism are improved, a finesse of 30 is attainable. The predictions also suggest that a reduction of the air gap to 1 micrometer results in an increased wavelength tuning range of 175 nm with a CMOS compatible 4.75V.

Patterson, James D.↗

Cryogenic Optical Performance of the Cassini Composite InfraRed Spectrometer (CIRS) Flight Telescope

The CIRS half-meter diameter beryllium flight telescope's optical performance was tested at the instrument operating temperature of 170 Kelvin. The telescope components were designed at Goddard Space Flight Center (GSFC) but fabricated out of house and then assembled, aligned and tested upon receipt at GSFC. A 24 inch aperture cryogenic test facility utilizing a 1024 x 1024 CCD array was developed at GSFC specifically for this test. The telescope,s image quality (measured as encircled energy), boresight stability and focus stability were measured. The gold coated beryllium design exceeded the cold image performance requirement of 80% encircled energy within a 460 micron diameter circle.

Losch, Patricia↗

MEMS Louvers for Thermal Control

Mechanical louvers have frequently been used for spacecraft and instrument thermal control purposes. These devices typically consist of parallel or radial vanes, which can be opened or closed to vary the effective emissivity of the underlying surface. This project demonstrates the feasibility of using Micro-Electromechanical Systems (MEMS) technology to miniaturize louvers for such purposes. This concept offers the possibility of substituting the smaller, lighter weight, more rugged, and less costly MEMS devices for such mechanical louvers. In effect, a smart skin that self adjusts in response to environmental influences could be developed composed of arrays of thousands of miniaturized louvers. Several orders of magnitude size, weight, and volume decreases are potentially achieved using micro-electromechanical techniques. The use of this technology offers substantial benefits in spacecraft/instrument design, integration and testing, and flight operations. It will be particularly beneficial for the emerging smaller spacecraft and instruments of the future. In addition, this MEMS thermal louver technology can form the basis for related spacecraft instrument applications. The specific goal of this effort was to develop a preliminary MEMS device capable of modulating the effective emissivity of radiators on spacecraft. The concept pursued uses hinged panels, or louvers, in a manner such that heat emitted from the radiators is a function of louver angle. An electrostatic comb drive or other such actuator can control the louver position. The initial design calls for the louvers to be gold coated while the underlying surface is of high emissivity. Since, the base MEMS material, silicon, is transparent in the InfraRed (IR) spectrum, the device has a minimum emissivity when closed and a maximum emissivity when open. An initial set of polysilicon louver devices was designed at the Johns Hopkins Applied Physics Laboratory in conjunction with the Thermal Engineering Branch at NASA's Goddard Space Flight Center.

Champion, J. L.↗

Cryogenic Optical Performance of the Cassini Composite Infrared Spectrometer (CIRS) Flight Telescope

The CIRS half-meter diameter beryllium flight telescope's optical performance was tested at the instrument operating temperature of 170 Kelvin. The telescope components were designed at Goddard Space Flight Center (GSFC) but fabricated out of house and then assembled, aligned and tested upon receipt at GSFC. A 24 inch aperture cryogenic test facility utilizing a 1024 x 1024 CCD array was developed at GSFC specifically for this test. The telescope's image quality (measured as encircled energy), boresight stability and focus stability were measured. The gold coated beryllium design exceeded the image performance requirement of 80% encircled energy within a 432 microns diameter circle.