Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “glass formulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

IMPACTS OF SMALL COLUMN ION EXCHANGE STREAMS ON DWPF GLASS FORMULATION: KT01, KT02, KT03, AND KT04-SERIES GLASS COMPOSITIONS

Four series of glass compositions were selected, fabricated, and characterized as part of a study to determine the impacts of the addition of Crystalline Silicotitanate (CST) and Monosodium Titanate (MST) from the Small Column Ion Exchange (SCIX) process on the Defense Waste Processing Facility (DWPF) glass waste form and the applicability of the DWPF process control models. The KT01 and KT02-series of glasses were chosen to allow for the identification of the influence of the concentrations of major components of the glass on the retention of TiO{sub 2}. The KT03 series of glasses was chosen to allow for the identification of these influences when higher Nb{sub 2}O{sub 5} and ZrO{sub 2} concentrations are included along with TiO2. The KT04 series of glasses was chosen to investigate the properties and performance of glasses based on the best available projections of actual compositions to be processed at the DWPF (i.e., future sludge batches including the SCIX streams).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Glass Formulation Development and Testing for DWPF High AI 2 O 3 HLW Sludges (Final report)

The principal objective of the work described in this Final Report is to develop and identify glass frit compositions for a specified DWPF high-aluminum based sludge waste stream that maximizes waste loading while maintaining high production rate for the waste composition provided by ORP/SRS. This was accomplished through a combination of crucible-scale, vertical gradient furnace, and confirmation tests on the DM100 melter system. The DM100-BL unit was selected for these tests. The DM100-BL was used for previous tests on HLW glass compositions that were used to support subsequent tests on the HLW Pilot Melter. It was also used to process compositions with waste loadings limited by aluminum, bismuth, and chromium, to investigate the volatility of cesium and technetium during the vitrification of an HLW AZ-102 composition, to process glass formulations at compositional and property extremes, and to investigate crystal settling on a composition that exhibited one percent crystals at 963°C (i.e., close to the WTP limit).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GLASS FORMULATION DEVELOPMENT AND TESTING FOR COLD CRUCIBLE INDUCTION MELTER (CCIM) ADVANCED REMEDIATION TECHNOLOGIES DEMONSTRATION PROJECT - 9208

Over the past few years, Cold Crucible Induction Melter (CCIM) demonstrations have been completed using SRS sludge batches 2, 3 and 4 (SB2, SB3 and SB4) simulant compositions. These campaigns demonstrated the ability of the CCIM to effectively produce quality glasses at high waste loadings. The current Advanced Remediation Technology (ART) Phase II-A Project is aimed at demonstrating the CCIM technology under representative DWPF flowsheet conditions and to demonstrate extended operations of the melter. A glass composition development effort was completed to identify and recommend a frit composition and sludge batch 4 (SB4) simulant waste loading target for subsequent ART-Phase II-A CCIM demonstration testing. Based on the results of the glass formulation testing, it was recommended that the Frit 503-R6 composition (B{sub 2}O{sub 3} = 14 wt %; Li{sub 2}O = 9 wt %; Na{sub 2}O = 3 wt %; and SiO{sub 2} = 74 wt %) be utilized for the demonstration. Furthermore, a waste loading of 46 wt % was recommended. The recommended frit and waste loading would produce a glass with acceptable durability with a liquidus temperature adequately below the 1250 C nominal CCIM operating temperature. This frit composition and waste loading was found to result in a glass that met CCIM processing requirements for viscosity, electrical conductivity and thermal conductivity. The recommended frit and waste loading level should also provide a buffer for sludge product compositional variation to support the Phase II-A CCIM demonstration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Waste Loading Glass Formulation Development for High-Zr HLW

This report describes work performed to develop and test new glass and feed formulations in order to increase waste loadings and glass melting rates for Hanford HLW with high concentrations of zirconium. Testing was designed to identify glass and melter feed formulations that optimize waste loading and waste processing rate while meeting all processing and product quality requirements. The work included preparation and characterization of crucible melts to evaluate the effects of waste loading on glass properties and the maximum waste loadings that can be achieved. The testing included an assessment of melt rate using a Vertical Gradient Furnace (VGF) system to develop new formulations with both high waste loadings and high melt rates. The results from crucible-scale testing supported subsequent DM100 tests designed to further assess the enhanced glass and feed formulations with respect to processing rate and product quality.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Waste Loading Glass Formulation Development for High-Cr HLW, VSL-14R3060-1 (April 2014)

This report describes work performed to develop and test new glass and feed formulations with both high waste loadings and high melting rates for Hanford high level waste (HLW) with high concentrations of chromium. The testing was designed to identify glass and melter feed formulations that optimize waste loading and waste processing rate while meeting all processing and product quality requirements. The work included preparation and characterization of crucible melts to assess melt rate using a vertical gradient furnace system and testing with respect to properties that determine processability and product quality. The results from crucible-scale testing supported subsequent DM100 tests designed to further assess the enhanced glass and feed formulations with respect to processing rate and product quality. The DM100-BL, which is one of two DM100 melter systems installed at VSL, was selected as the platform for these tests due to its extensive previous use in processing rate determination for various HLW streams and glass compositions. This work builds on previous work performed at VSL for DOE to increase waste loadings in HLW glass formulations and processing rates. The testing was performed according to the Test Plan that was developed for this work.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Waste Loading Glass Formulation Development for High-Sr HLW

This report describes work performed to develop and test new glass and feed formulations in order to increase waste loading and glass melting rates for Hanford HLW with high concentrations of strontium. Testing was designed to identify glass and melter feed formulations that optimize waste loading and waste processing rate while meeting all processing and product quality requirements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Glass formulation and composition optimization with property models: A review

Abstract Glass is a versatile material with a remarkable history and many practical applications. It plays a critical role in our everyday lives, the advancement of science, and the development of many technologies. The Edisonian type trial‐and‐error method was commonly used for conventional design of glass compositions, which was time‐consuming and costly. With the urgent need to develop new glass compositions for technology applications rapidly, it has become necessary to develop precise property models with predictive powers using large databases and efficient formulation approaches. This paper reviews the design of glass compositions using these analytical and numerical models of composition–structure–property relations of glasses, some based on large databases and machine learning approaches. Aspects of data collection, model fitting, feature extraction, model evaluation, and uncertainty quantification will be covered. Furthermore, advances in the glass optimization framework and available tools are summarized with examples. The outlook and perspective for further glass property model development and formulation approaches are discussed.

Lu, Xiaonan↗

Compilation and Management of ORP Glass Formulation Database

The present report describes the first steps in the development of a glass property-composition database for WTP LAW and HLW glasses that includes all of the data that were used in the development of the WTP baseline models and all of the data collected subsequently as part of WTP enhancement studies performed for ORP. The data were reviewed to identify some of the more significant gaps in the composition space that will need to be filled to support waste processing at Hanford. The WTP baseline models have been evaluated against the new data in terms of range of validity and prediction performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Melt Rate Enhancement for High Aluminum HLW Glass Formulation (Final Report)

The principal objective of the work reported here was to develop and identify HLW glass compositions that maximize waste processing rates for the aluminum limted waste composition specified by ORP while maintaining high waste loadings and acceptable glass properties. This was accomplished through a combination of crucible-scale tests, confirmation tests on the DM100 melter system, and demonstration at pilot scale (DM1200). The DM100-BL unit was selected for these tests since it was used previously with the HLW waste streams evaluated in this study, was used for tests on HLW glass compositions to support subsequent tests on the HLW Pilot Melter, conduct tests to determine the effect of various glass properties (viscosity and conductivity) and oxide concentrations on glass production rates with HLW feed streams, and to assess the volatility of cesium and technetium during the vitrification of an HLW AZ-102 composition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High waste loading glass formulation development for high-P HLW

The primary objective of the work described herein was to develop and identify HLW glass compositions and glass forming additive blends that achieve high waste loadings and processing rates for high phosphorus HLW streams while maintaining acceptable glass properties. This was accomplished through a combination of crucible-scale tests, vertical gradient furnace tests, and confirmation tests on the DM100 melter system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High waste loading glass formulation development for High-Mn HLW

One of the primary objectives of the work described herein was to develop and identify HLW glass compositions and glass forming additive blends that achieve high waste loadings and processing rates for high manganese HLW streams while maintaining acceptable glass properties. Another objective was to determine the effect of the form of manganese (MnO, MnO2, MnCO3) on feed processing properties, glass production rates, and product quality while vitrifying a high manganese HLW stream. This was accomplished through a combination of crucible-scale tests, vertical gradient furnace tests, and confirmation tests on a DM100 melter system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Glass Formulation Development for Al, Fe, and Na Phosphate HLW

The primary objective of the work described herein was to develop and identify HLW glass compositions and glass forming additive blends that achieve high waste loadings and processing rates for high phosphorus HLW streams while maintaining acceptable glass properties. Another objective was to determine the effect of phosphate form (aluminum, iron, sodium) on feed processing properties, glass production rates, and product quality while vitrifying a high phosphorus HLW stream. This was accomplished through a combination of crucible-scale tests, vertical gradient furnace tests, and confirmation tests on a DM100 melter system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Glass Formulation Testing to Increase Sulfate Volatilization from Melter (Final Report)

The principal objectives of the DM100 and DM10 tests were to determine the impact of four different organics and one inorganic feed additive on sulfate volatilization and to determine the sulfur partitioning between the glass and the off-gas system. The tests provided information on melter processing characteristics and off-gas data including sulfur incorporation and partitioning. A series of DM10 and DM100 melter tests were conducted using a LAW Envelope A feed. The testing was divided into three parts. The first part involved a series of DM10 melter tests with four different organic feed additives: sugar, polyethylene glycol (PEG), starch, and urea.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Novel Glass Formulations for Post Operational Clean Out of Highly Active Storage Tanks - 17596

The UK has a successful history of reprocessing nuclear fuel from both UK nuclear reactors and for overseas customers. Highly Active Liquor (HAL), a waste product from reprocessing, is stored in stainless steel tanks before being incorporated into a stable glass matrix in one of three vitrification lines at Sellafield. Over the next 4 years Sellafield Ltd will cease reprocessing nuclear fuel, and the reprocessing plants and storage tanks will enter a Post Operational Clean Out (POCO) phase to remove the radioactive inventory and prepare for future decommissioning. POCO feeds are expected to differ greatly from current HAL, and will contain high levels of molybdenum solids. This paper, and subsequent poster presentation, introduces the vitrification challenges expected with processing POCO waste-streams. The main challenge is the transfer and processing of high molybdenum containing solids. Details of the application of new glasses onto the active vitrification plant will also be included. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Product Quality Assessment of Glass Formulations for High Sodium Nuclear Waste Streams - 18198

Sodium carbonate is currently being considered as a wash-out reagent for the removal of the settled solids in the unagitated Highly Active Liquor (HAL) storage tanks at Sellafield. As the settled solids are expected to comprise mainly zirconium molybdate (ZM), this will result in a feed to the Waste Vitrification Plant (WVP) containing high concentrations of both molybdenum and sodium. This feed is expected to be challenging for WVP due to solubility limitations in existing base glass compositions and the operating temperature. In particular, depending on the wash-out strategy employed, there is the potential to produce high volumes of sodium-containing waste, which will result in large quantities of vitrified HLW containers. Hence, new glass compositions are being investigated as part of a 3-year Innovate UK-funded collaborative project in order to maximise the sodium content of the vitrified product and minimise the number of containers produced. This paper describes the product quality assessment of several sodium titanosilicate (NaTiSi) compositions that can potentially contain up to ∼15 wt% waste Na{sub 2}O, more than double what is possible using the current UK HLW glass borosilicate composition. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Glass Formulation Testing to Increase Sulfate Incorporation

About 50 million gallons of high-level mixed waste is currently in storage in underground tanks at The United States Department of Energy's (DOE's) Hanford site in the State of Washington. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will provide DOE's Office of River Protection (ORP) with a means of treating this waste by vitrification for subsequent disposal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IMPACT OF SMALL COLUMN ION EXCHANGE STREAMS ON DWPF GLASS FORMULATION MELT RATE STUDIES

This study was undertaken to evaluate the potential impacts of the Small Column Ion Exchange (SCIX) streams - particularly the addition of Monosodium Titanate (MST) and Crystalline Silicotitanate (CST) - on the melt rate of simulated feed for the Defense Waste Processing Facility (DWPF). Additional MST was added to account for contributions from the Salt Waste Processing Facility (SWPF). The Savannah River National Laboratory (SRNL) Melt Rate Furnace (MRF) was used to evaluate four melter feed compositions: two with simulated SCIX and SWPF material and two without. The Slurry-fed Melt Rate Furnace (SMRF) was then used to compare two different feeds: one with and one without bounding concentrations of simulated SCIX and SWPF material. Analyses of the melter feed materials confirmed that they met their targeted compositions. Four feeds were tested in triplicate in the MRF. The linear melt rates were determined by using X-ray computed tomography to measure the height of the glass formed along the bottom of the beakers. The addition of the SCIX and SWPF material reduced the average measured melt rate by about 10% in MRF testing, although there was significant scatter in the data. Two feeds were tested in the SMRF. It was noted that the ground CST alone (ground CST with liquid in a bucket) was extremely difficult to resuspend during preparation of the feed with material from SCIX and SWPF. This feed was also more difficult to pump than the material without MST and CST due to settling occurring in the melter feed line, although the yield stress of both feeds was high relative to the DWPF design basis. Steady state feeding conditions were maintained for about five hours for each feed. There was a reduction in the feed and pour rates of approximately 15% when CST and MST were added to the feed, although there was significant scatter in the data. Analysis of samples collected from the SMRF pour stream showed that the composition of the glass changed as expected when MST and CST were added to the feed. These reductions in melt rate are consistent with previous studies that showed a negative impact of increased TiO{sub 2} concentrations on the rate of melting. The impact of agitating the melt pool via bubbling was not studied as part of this work, but may be of interest for further testing. It is recommended that additional melt rate testing be performed should a potential reduction in melt rate of 10-15% be considered an issue of concern, or should the anticipated composition of the glass with the addition of material from salt waste processing be modified significantly from the current projections, either due to changes in sludge batch preparation or changes in the composition or volume of SCIX and SWPF material.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TECHNOLOGY DEMONSTRATION OF SLUDGE MASS REDUCTION VIA ALUMINUM DISSOLUTION: GLASS FORMULATION PROCESSING WINDOW PREDICTIONS FOR SB5

Composition projections for Sludge Batch 5 (SB5) were developed, based on a modeling approach at the Savannah River National Laboratory (SRNL), to evaluate possible impacts of the Al-dissolution process on the availability of viable frit compositions for vitrification at the Defense Waste Processing Facility (DWPF). The study included two projected SB5 compositions that bound potential outcomes (or degrees of effectiveness) of the Al-dissolution process, as well as a nominal SB5 composition projection based on the results of the recent Al-dissolution demonstration at SRNL. The three SB5 projections were the focus of a two-stage paper study assessment. A Nominal Stage assessment combined each of the SB5 composition projections with an array of 19,305 frit compositions over a wide range of waste loading (WL) values and evaluated them against the DWPF process control models. The Nominal Stage results allowed for the down-selection of a small number of frits that provided reasonable projected operating windows (typically 27 to 42 wt% WL). The frit/sludge systems were mostly limited by process related constraints, with only one system being limited by predictions of nepheline crystallization, a waste form affecting constraint. The criteria applied in selecting the frit compositions somewhat restricted the compositional flexibility of the candidate frits for each individual SB5 composition projection, which may limit the ability to further tailor the frit for improved melt rate. Variation Stage assessments were then performed using the down-selected frits and the three SB5 composition projections with variation applied to each sludge component. The Variation Stage results showed that the operating windows were reduced in width, as expected when variation in the sludge composition is applied. However, several of the down-selected frits exhibited a relatively high degree of robustness to the applied sludge variation, providing WL windows of approximately 30 to 39 wt%. The maximum WLs were limited by processing constraints, liquidus temperature and low viscosity, rather than a waste form affecting constraint (e.g., nepheline crystallization) in the Variation Stage assessments. These paper study assessments have identified candidate frits which, when combined with the SRNL projected SB5 compositions after Al-dissolution, have projected operating windows that should be reasonable for DWPF processing. As more information is obtained on the SB5 composition to be processed in DWPF, including the actual Al removed and Tank 7 mass transferred, additional paper study assessments will be performed as well as experimental frit development studies. The frits identified in this study provide insight into potential processing windows but are not the recommended frits for SB5. No information regarding melt rate can be inferred from the paper study results. Experimental studies to evaluate this critical factor in DWPF processing must be performed on the best SB5 projection before a frit recommendation could be made for any projected sludge composition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗