Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “generation mix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Existing Methods for Grid Strength Assessment and Role of Hydropower in Future Grids

The power system is undergoing rapid evolution with increasing penetration of inverter-based resources (IBRs), large loads, microgrids, and power electronic devices. Ensuring reliable and stable operation of the modern power grid is a multi-faceted challenge that requires detailed understanding of this complex system. Dynamic stability is a major concern in maintaining the security of power grids as the generation mixes and large loads transitions to include high shares of power electronic devices. The operation of IBRs in regions with low system strength and higher grid impedances has been found to be the main reason behind many of the power system instabilities that manifest themselves in various types of oscillations and interactions that, if not properly addressed and damped, can jeopardize the reliable operation of the power system. Weak grid conditions compound such stability problems, particularly when many IBRs operate in proximity to and connect to weak power grids. Therefore, it is important to assess grid strength for planning, integration and operation of IBRs for a given power system. In this report, we aim to understand and classify existing methodologies for grid strength assessment, along with their limitations and future needs. Further, we aim to utilize the huge untapped potential in utilizing hydro energy resources in addressing some of the pertinent challenges of grid strength and reliable operation of modern power systems. Hydropower, historically valued for its flexibility and dispatchability, now faces new constraints due to reduced share of synchronous machines in the generation mix and seasonal variability of available water resources. Yet, these same plants present untapped potential beyond energy generation - notably, as providers of critical grid services. This report explores how hydropower plants, particularly through operation as synchronous condensers, can play a pivotal role in strengthening the grid amid evolving system dynamics.

13 HYDRO ENERGY↗

Evolving Electricity Supply and Demand to Achieve Net-Zero Emissions: Insights from the EMF-37 Study

This paper explores the role of electricity in achieving economy-wide net-zero CO2 emissions by 2050 in the United States based on results from 17 models as part of the 37th Stanford Energy Modeling Forum (EMF-37). In the study's Net-Zero scenario, the models use diverse pathways to achieve net-zero emissions by 2050, with gross energy-related residual emissions ranging from 17.2 to 66.6 % of 2020 levels. Electricity consistently emerges as central to achieving net-zero, with models projecting rapid electrification of end-uses and rapidly declining CO2 intensity of electricity. However, the extent of electrification and the technology mix to decarbonize the power sector vary considerably across models. In the Net-Zero scenario, electricity is projected to evolve from ~20 % of final energy in 2020 to 17-63 % in 2050 across the models driven by electrification in all sectors-buildings, industry, and transportation-and, to a lesser extent by direct air capture. By 2050, total electricity consumption increases by 24-176 % (relative to 2020), accompanied by significant expansion in renewable electricity production. Together, solar and wind generation grows by 175-834 %, supplying 45-90 % of total electricity in 2050, with wind achieving slightly higher shares than solar. Electricity storage technologies are deployed at scale to support wind and solar generation. The electricity generation mix varies across models: some project almost complete reliance on renewables, while others see a substantial role for natural gas, often with carbon capture and storage. This paper synthesizes the rich diversity of modeling approaches and results, highlighting differing views on how key drivers of electricity demand and supply might evolve.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Valuation of Electric Power System Services and Technologies

Accurate valuation of existing and new technologies and grid services has been recognized to be important to stimulate investment in grid modernization. Clear, transparent, and accepted methods for estimating the total value (i.e., total benefits minus cost) of grid technologies and services are necessary for decision makers to make informed decisions. This applies to home owners interested in distributed energy technologies, as well as to service providers offering new demand response services, and utility executives evaluating best investment strategies to meet their service obligation. However, current valuation methods lack consistency, methodological rigor, and often the capabilities to identify and quantify multiple benefits of grid assets or new and innovative services. Distributed grid assets often have multiple benefits that are difficult to quantify because of the locational context in which they operate. The value is temporally, operationally, and spatially specific. It varies widely by distribution systems, transmission network topology, and the composition of the generation mix. The Electric Power Research Institute (EPRI) recently established a benefit-cost framework that proposes a process for estimating multiple benefits of distributed energy resources (DERs) and the associated cost. This document proposes an extension of this endeavor that offers a generalizable framework for valuation that quantifies the broad set of values for a wide range of technologies (including energy efficiency options, distributed resources, transmission, and generation) as well as policy options that affect all aspects of the entire generation and delivery system of the electricity infrastructure. The extension includes a comprehensive valuation framework of monetizable and non-monetizable benefits of new technologies and services beyond the traditional reliability objectives. The benefits are characterized into the following categories: sustainability, affordability, and security, flexibility, and resilience. This document defines the elements of a generic valuation framework and process as well as system properties and metrics by which value streams can be derived. The valuation process can be applied to determine the value on the margin of incremental system changes. This process is typically performed when estimating the value of a particular project (e.g., value of a merchant generator, or a distributed photovoltaic (PV) rooftop installation). Alternatively, the framework can be used when a widespread change in the grid operation, generation mix, or transmission topology is to be valued. In this case a comprehensive system analysis is required.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WECC Wide-Area Oscillation Assessment and Trending Study Report

This project, Wide-area Oscillation Analysis and Trending Study, is sponsored by the Office of Electricity (OE) of the Department of Energy (DOE) who tasked Northwest National Laboratory (PNNL) to conduct this research. Staff of Federal Energy Regulatory Commission (FERC) have been involved in the project as observers and have provided advisory comments and suggestions. The primary objective of this study is to assess whether there are significant trends in the wide-area oscillatory behavior with respect to the significant generation-mix changes brought by the increased penetration of RES in the WECC system. The work performed in this project is considered to be complimentary to previous work by NERC/industry and covers the aspects that have not been studied or trended before. The trending analysis presented in this report can serve as reference for future grid planning and operation of the WECC system. In this report, how the changes in the generation mix can impact the frequency and damping ratio (DR) of WECC wide-area oscillation modes has been studied. Thorough data-based and model-based analyses have been carried out to analyze the current trends and then extended to evaluate the oscillation behaviors of the future WECC system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neutrino Masses and Mixings Dynamically Generated by a Light Dark Sector

Neutrinos may be the harbingers of new dark sectors, since the renormalizable neutrino portal allows for their interactions with hidden new physics. We propose here to use this fact to connect the generation of neutrino masses to a light dark sector, charged under a new U(1)D dark gauge symmetry. We introduce the minimal number of dark fields to obtain an anomaly free theory with spontaneous breaking of the dark symmetry, and obtain automatically the inverse seesaw Lagrangian. In addition, the so-called μ -term of the inverse seesaw is dynamically generated and technically natural in this framework. As a bonus, the new light dark gauge boson can provide a possible explanation to the MiniBooNE anomaly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Component analysis of a mixed beam generated by vacuum electrospray of an ionic liquid

Vacuum electrospray of a quaternary ammonium ionic liquid, N,N-diethyl-N-methyl-N-(2-methoxyethyl)ammonium bis(trifluoromethanesulfonyl) amide (DEME-TFSA), was investigated to develop a primary ion source for secondary ion mass spectrometry (SIMS). Since the ionic liquid contains many methyl and ethyl groups as well as protons, its beam is expected to efficiently produce protonated molecules for SIMS analysis of organic materials. Experimental results showed that the beam consisted of charged particles of m/z about 1000 and charged droplets of m/z > 10{sup 5}. The current components of both the charged particles and droplets changed with the applied voltage and the flow rate of the ionic liquid. With decreasing flow rate, the current component of the charged droplets increased, whereas that of the charged particles decreased. The m/z values of the charged droplets diminished with decreasing flow rate and increasing capillary voltage. In addition to masses and charge numbers, the numbers of the charged droplets and the charged particles were estimated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Eastern Interconnection Wide-Area Oscillation Assessment and Study Report

To meet the government mandates such as Renewable Portfolio Standards (RPS), conventional synchronous generators with rotating mass are being displaced by inverter-based resources (IBRs), leading to high penetration of renewable energy sources (RES). As a result, the inherent properties and characteristics of the transformed generation mix may significantly impact the grid behaviour, and it is of paramount significance that the impact and the consequences of the resource mix change is thoroughly understood to adopt measures to maintain reliable grid operations. Of great concern is the inter-area low-frequency oscillation, which usually propagates through a large region and has a system-wide impact. Such oscillations may lead to unnecessary or inadvertent tripping of generators, that may be simply reacting to the oscillation originating from geographically remote sites. Such tripping of generators can lead to cascading outages, system split and load loss events. Over the years, several system-wide oscillation events have been observed across all three North American interconnections. This project titled Wide-area Oscillation Assessment and Trending Study, sponsored by the Office of Electricity (OE) of the Department of Energy (DOE), aims to conduct the required research to capture and investigate the potential changes in wide-area oscillatory performance of the system as a result of resource mix transition. The Pacific Northwest National Laboratory (PNNL) conducted this research and technical staff of Federal Energy Regulatory Commission (FERC) served as advisors to the project. The primary objective of this study is to assess whether there are significant trends in the power system wide-area oscillatory behaviours, as a result of the generation-mix changes due to the increased penetration of RES in the U.S. Eastern Interconnection (EI). The analysis presented in this report can serve as reference for future grid planning and operation of the EI system. This research conducted in this project evaluates the wide-area oscillatory behaviour of the EI, using a model-based approach for potential future resource mixes, and the measurement-based analysis with 21-month phasor measurement unit (PMU) time series. The oscillation modes in EI system along with the impact of the changes of the generation mix on the frequency and damping ratio (DR) of the oscillations have been studied.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Benefit Analysis of Long-Duration Energy Storage in Power Systems with High Renewable Energy Shares

The integration of high shares of variable renewable energy raises challenges for the reliability and cost-effectiveness of power systems. The value of long-duration energy storage, which helps address variability in renewable energy supply across days and seasons, is poised to grow significantly as power systems shift to larger shares of variable generation such as wind and solar. This study explores the system-level services and associated benefits of long-duration energy storage on the 2050 Western Interconnection (WI). The operation of the future WI system with 85% renewable penetration is simulated using a two-stage production cost model. The impact of long duration energy storage on systemwide operations is examined for the 2050 WI system, using a range of round-trip efficiencies corresponding to four different energy storage technologies. The analysis projects the energy storage dispatch profile, system-wide production cost savings (from both diurnal and seasonal operation), and impacts on generation mix, and change in renewable generation curtailment.

25 ENERGY STORAGE↗

Policy and Regulatory Environment for Utility-Scale Energy Storage: Bangladesh

Bangladesh has experienced significant economic growth and poverty reduction over the past several decades. Recognizing the central role electricity plays in economic development, the Government of Bangladesh (GOB) has established policies to accelerate the growth of the electric power sector. The Bangladesh power grid is transforming into one marked by declining reliance on domestic natural gas reserves and oil-based rental power plants, increasing renewable energy contribution, and shifting demand patterns. The GOB is now reconsidering its prior plans to increase the share of coal capacity in the generation mix to meet demand, shifting its focus instead to electricity imports from neighboring countries, nuclear generation, liquified natural gas imports, and domestic renewable resources such as wind and solar. However, investments in the transmission and distribution system, as well as ancillary services, have not kept pace with investments in generation resources over the past decade. Thus, Bangladesh electricity consumers still experience outages and poor power quality despite adequate installed capacity. On the demand side, population growth and industrialization have fueled steady growth in electricity consumption as efforts to expand access to electricity enabled near-universal electricity access by mid-2020. The combined changes in the mix of generation resources and patterns of electricity demand present new challenges and opportunities in operating and maintaining a reliable power system. Energy storage has the potential to help meet these challenges and accelerate Bangladesh’s energy transition. Declining costs for some energy storage technologies make them increasingly cost-effective solutions to provide a wide range of grid services. Previous analyses of energy storage in the region have identified several potential applications for storage at the bulk system level, including energy arbitrage, ancillary services, and transmission network support. The potential for storage to meet these needs depends on many factors, including physical characteristics of the power system and the policy and regulatory environments in which these energy storage assets would operate. This report applies an Energy Storage Readiness Assessment the National Renewable Energy Laboratory developed for policy makers and regulators to identify priority areas of focus as they continue to develop the appropriate suite of policies, programs, and regulations to enable storage deployment. This assessment uses a simple evaluation scheme to identify the barriers and opportunities for utility-scale energy storage within Bangladesh’s policy and regulatory environment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Capacity Adequacy and Revenue Sufficiency in Electricity Markets With Wind Power

We present a computationally efficient mixed-integer program (MIP) that determines optimal generator expansion decisions, as well as periodic unit commitment and dispatch. The model is applied to analyze the impact of increasing wind power capacity on the optimal generation mix and the profitability of thermal generators. In a case study, we find that increasing wind penetration reduces energy prices while the prices for operating reserves increase. Moreover, scarcity pricing for operating reserves through reserve shortfall penalties significantly impacts the prices and profitability of thermal generators. Without scarcity pricing, no thermal units are profitable, however scarcity pricing can ensure profitability for peaking units at high wind penetration levels. Capacity payments can also ensure profitability, but the payments required for baseload units to break even increase with the amount of wind power. The results indicate that baseload units are most likely to experience revenue sufficiency problems when wind penetration increases and new baseload units are only developed when natural gas prices are high and wind penetration is low.

capacity adequacy↗

Regional Emissions Analysis of Light-Duty Battery Electric Vehicles

Light-duty battery electric vehicles (BEVs) can reduce both greenhouse gas (GHG) and criteria air pollutant (CAPs) emissions, when compared to gasoline vehicles. However, research has found that while today’s BEVs typically reduce GHGs, they can increase certain CAPs, though with significant regional variability based on the electric grid mix. In addition, the environmental performance of electric and gasoline vehicles is not static, as key factors driving emissions have undergone significant changes recently and are expected to continue to evolve. In this study, we perform a cradle-to-grave life cycle analysis using state-level generation mix and vehicle operation emission data. We generated state-level emission factors using a projection from 2020 to 2050 for three light-duty vehicle types. We found that BEVs currently provide GHG benefits in nearly every state, with the median state’s benefit being between approximately 50% to 60% lower than gasoline counterparts. However, gasoline vehicles currently have lower total NOx, urban NOx, total PM 2.5 , and urban PM 2.5 in 33%; 15%; 70%; and 10% of states, respectively. BEV emissions will decrease in 2050 due to a cleaner grid, but the relative benefits when compared to gasoline vehicles do not change significantly, as gasoline vehicles are also improving over this time.

33 ADVANCED PROPULSION SYSTEMS↗

Entropy generation from hydrodynamic mixing in inertial confinement fusion indirect-drive targets

The increase in entropy from the physical mixing of two adjacent materials in inertial confinement fusion (ICF) implosions and gas-filled hohlraums is analytically assessed. An idealized model of entropy generation from the mixing of identical ideal-gas particles across a material interface in the presence of pressure and temperature gradients is applied. Physically, mix-driven entropy generation refers to the work done by the gases in expanding into a larger common volume from atomic mixing under the condition of no internal energy change, or work needed to restore the initial unmixed state. Furthermore, the effect of a mix-generated entropy increase is analytically shown to lead to less compression of the composite ICF fluid under adiabatic conditions. The amount of entropy generation is estimated to be ~10 J for a Rayleigh–Taylor-induced micrometer-scale annular mixing layer between the solid deuterium–tritium fuel and (undoped) high-density carbon pusher of an imploding capsule at the National Ignition Facility (NIF). This level of entropy generation is consistent with lower-than-expected fuel compressions measured on the NIF [Hurricane et al., Phys. Plasmas 26, 052704 (2019)]. The degree of entropy increase from mixing of high-Z hohlraum wall material and low-Z, moderate- to high-density gas fills is estimated to lead to ~100 kJ of heat generation for NIF-scale experiments [Moody et al., Phys. Plasmas 21, 056317 (2014)]. This value represents a significant fraction of the inferred missing x-ray drive energy based on observed delays in capsule implosion times compared with mainline simulations [Jones et al., Phys. Plasmas 19, 056315 (2012)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic Equivalence of Large-Scale Power Systems Based on Boundary Measurements

Parallel computing helped speed up many tasks that can be done independently. The advance in gaming industry did not produce a technology that helps the power industry to reduce the computation time for dynamic simulation in individual cases. To perform faster than real-time simulation for the purpose of predicting power system dynamic trajectory, power industry continues to struggle to reduce the system size and simulation time of large-scale power systems while keeping its dynamic behavior under various disturbances. There is also an acute need for real-time dynamic model reduction as more renewables enter the generation mix with dramatic changes in the generation outputs. All existing model reduction solutions are based on having access to a detailed dynamic model of the system. The system changes by the minutes, dynamic models are only updated annually. To solve this problem, wide-area measurements obtained by the phasor measurement unit (PMU) at the boundaries between the reduced system and the study system is used to represent the external area. An artificial neuro-fuzzy inference system (ANFIS) is established to perform the mapping of the measurement to the external equivalent model. Here the external area is regarded as a black-box. Model reduction studies are conducted on the Northeast Power Coordinating Council (NPCC) under various types of contingencies, by using a co-simulation approach between PSS/E and MATLAB. The results look very promising and will be discussed in this paper.

Tong, Ning↗

Mixing of the Connecticut River Plume During Ambient Flood Tides: Spatial Heterogeneity and Contributions of Bottom–Generated and Interfacial Mixing

The Connecticut River plume is influenced by energetic ambient tides in the Long Island Sound receiving waters. The objectives of this modeling study are (a) characterizing the spatial heterogeneity of turbulent buoyancy fluxes, (b) partitioning turbulent buoyancy fluxes into bottom-generated and interfacial shear contributions, and (c) quantifying contributions to plume-integrated mixing within the tidal plume. The plume formed during ambient flood tides under low river discharge, spring tides, and no winds is analyzed. Turbulent buoyancy fluxes (B) and depth-integrated B through the plume (Bd) are characterized by pronounced spatial heterogeneity. Strong mixing (Bd ~ 10 –5 -10 –4 m 3 /s 3 ) occurs near the mouth, in the nearfield plume turning region, over shoals, and nearshore shallow areas. Low to moderate mixing (Bd ~ 10 –8 -10 –6 m 3 /s 3 ) occupies half the plume. Buoyancy fluxes are first partitioned based on the depth of the shear stress minimum between plume-generated and bottom-generated shear maxima. Four other tested partitioning methods are based on open channel flow and stratified shear flow parameterizations. Interfacial and bottom-generated shear contribute to different areas of intense and moderate mixing. All methods indicate a significant plume mixing role for bottom-generated mixing, but interfacial mixing is a bigger contributor. Plume-integrated total and interfacial mixing peak at max ambient flood and the timing of peak bottom-generated mixing varies among partitioning methods. Two-thirds of the mixing occurs in concentrated intense mixing areas. A parameter space with the ambient tidal Froude number and plume thickness to depth ratio as axes indicates many tidally modulated plumes are moderately to dominantly influenced by bottom-generated tidal mixing.

54 ENVIRONMENTAL SCIENCES↗

GREENHOUSE GAS REDUCTION POTENTIAL WITH COMBINED HEAT AND POWER WITH DISTRIBUTED GENERATION PRIME MOVERS - ASME 2012

Pending or recently enacted greenhouse gas regulations and mandates are leading to the need for current and feasible GHG reduction solutions including combined heat and power (CHP). Distributed generation using advanced reciprocating engines, gas turbines, microturbines and fuel cells has been shown to reduce greenhouse gases (GHG) compared to the U.S. electrical generation mix due to the use of natural gas and high electrical generation efficiencies of these prime movers. Many of these prime movers are also well suited for use in CHP systems which recover heat generated during combustion or energy conversion. CHP increases the total efficiency of the prime mover by recovering waste heat for generating electricity, replacing process steam, hot water for buildings or even cooling via absorption chilling. The increased efficiency of CHP systems further reduces GHG emissions compared to systems which do not recover waste thermal energy. Current GHG mandates within the U.S Federal sector and looming GHG legislation for states puts an emphasis on understanding the GHG reduction potential of such systems. This study compares the GHG savings from various state-of-the- art prime movers. GHG reductions from commercially available prime movers in the 1-5 MW class including, various industrial fuel cells, large and small gas turbines, micro turbines and reciprocating gas engines with and without CHP are compared to centralized electricity generation including the U.S. mix and the best available technology with natural gas combined cycle power plants. The findings show significant GHG saving potential with the use of CHP. Also provided is an exploration of the accounting methodology for GHG reductions with CHP and the sensitivity of such analyses to electrical generation efficiency, emissions factors and most importantly recoverable heat and thermal recovery efficiency from the CHP system.

03 NATURAL GAS↗