Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas time projection chambers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Operation and performance of a dual-phase crystalline/vapor xenon time projection chamber

We have built and operated a crystalline/vapor xenon TPC, with the goal of improving searches for dark matter. The motivation for this instrument is the fact that beta decays from the radon decay chain to the ground state presently limit the state-of-the-art liquid/vapor xenon experiments. In contrast, a crystalline xenon target has the potential to exclude, or tag and reject radon-chain backgrounds. As a preamble to demonstrating such capabilities, the present article makes a first demonstration of the operation of a crystalline/vapor xenon TPC with electroluminescence (gas gain) for the electron signal readout. It also shows that the scintillation yield in crystalline xenon appears to be identical to that in liquid xenon, in contrast to previous results.

47 OTHER INSTRUMENTATION↗

Neutron-upscattering enhancement of the triple-alpha process

Abstract The neutron inelastic scattering of carbon-12, populating the Hoyle state, is a reaction of interest for the triple-alpha process. The inverse process (neutron upscattering) can enhance the Hoyle state’s decay rate to the bound states of 12 C, effectively increasing the overall triple-alpha reaction rate. The cross section of this reaction is impossible to measure experimentally but has been determined here at astrophysically-relevant energies using detailed balance. Using a highly-collimated monoenergetic beam, here we measure neutrons incident on the Texas Active Target Time Projection Chamber (TexAT TPC) filled with CO 2 gas, we measure the 3 α -particles (arising from the decay of the Hoyle state following inelastic scattering) and a cross section is extracted. Here we show the neutron-upscattering enhancement is observed to be much smaller than previously expected. The importance of the neutron-upscattering enhancement may therefore not be significant aside from in very particular astrophysical sites (e.g. neutron star mergers).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scintillation light detection performance for the DUNE ND-LAr 2 × 2 modules

The Deep Underground Neutrino Experiment (DUNE) will be using a liquid argon time projection chamber (LAr TPC) with optically separated modules in the Near Detector (ND) complex. A prototype experiment, DUNE ND-LAr 2 × 2, is composed of four test modules. They detect ionization charge through a pixel-based readout and scintillation light through fibers in light collection modules and light traps called ArCLights. The light detection performance for two modules of DUNE ND-LAr 2 × 2 that took cosmic ray data at the University of Bern is shown. We present further the role of the 2 × 2 prototype in DUNE and how it is used to demonstrate the reconstruction capabilities of its light detectors in terms of energy thresholds and timing resolution.

47 OTHER INSTRUMENTATION↗

Design and implementation of the new scintillation light detection system of ICARUS T600

ICARUS T600 is the far detector of the Short Baseline Neutrino program at Fermilab (U.S.A.), which foresees three Liquid Argon Time Projection Chambers along the Booster Neutrino Beam line to search for LSND-like sterile neutrino signal. The T600 detector underwent a significant overhauling process at CERN, introducing new technological developments while maintaining the already achieved performances. The realization of a new liquid argon scintillation light detection system is a primary task of the detector overhaul. As the detector will be subject to a huge flux of cosmic rays, the light detection system should allow the 3D reconstruction of events contributing to the identification of neutrino interactions in the beam spill gate. The design and implementation of the new scintillation light detection system of ICARUS T600 is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kinematics reconstruction in solenoidal spectrometers operated in active target mode

Here, we discuss the reconstruction of low-energy nuclear reaction kinematics from charged-particle tracks in solenoidal spectrometers working in Active Target Time Projection Chamber mode. In this operation mode, reaction products are tracked within the active gas medium of the Active Target with a three dimensional space point cloud. We have inferred the reaction kinematics from the point cloud using an algorithm based on a linear quadratic estimator (Kalman filter). The performance of this algorithm has been evaluated using experimental data from nuclear reactions measured with the Active Target Time Projection Chamber (AT-TPC) detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gas electroluminescence in a dual phase xenon-doped argon detector

Noble element detectors using argon or xenon as the detection medium are widely used in the searches for rare neutrino and dark matter interactions. Xenon doping in liquid argon can preserve attractive properties of an argon target while enhancing the detectable signals with properties of xenon. Here, in this work, we deployed a dual-phase liquid argon detector with up to 4% xenon doping in the liquid and studied its gas electroluminescence properties as a function of xenon concentration. At ∼2% xenon doping in liquid argon, we measured ∼34 ppm of xenon in the gas and observed ∼2.5 times larger electroluminescence signals using vacuum ultraviolet silicon photomultipliers than those in pure argon. Analysis of signals of different wavelengths confirms that the argon gas electroluminescence process is strongly modified by the addition of xenon. We propose an analytical model to describe the underlying energy transfer mechanism in argon-xenon gas mixtures. Lastly, the implications of this measurement for low-energy ionization signal detection will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploiting the Photoelectric effect for X-ray Polarimetry using Time Projection Chamber

The promise of photoelectric X-ray polarimetry has now been realized in laboratory demonstrations and may soon be used for astrophysical observations. Photoelectric polarimetry in gas filled proportional counters achieves high sensitivity through a combination of broad band width and good modulation. The band can be tuned by careful choice of gas composition and pressure. The measurements rely on imaging the tracks of photoelectrons. The initial direction of each track carries information about the electric field of the X-ray photon, and an ensemble of such measurements thus measures the net polarization of the source. A novel readout geometry using time projection chambers (TPC) allows deep (i.e. high efficiency) detectors, albeit without the ability to image the sky. Polarimeters which exploit the TPC geometry can be optimized for use behind telescopes, to study faint persistent sources, or as wide field of view instruments, designed to study bright transient events such as gamma-ray bursts or solar flares. We present the conceptual design of both types of TPC polarimeter. Recent laboratory results demonstrate that these polarimeters can achieve substantial gains in the polarization sensitivity achievable in experiments of modest size.

Jahoda, Keith↗

Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffusion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe-He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the scintillation region, the EL yield is lowered by ~ 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of radon mitigation in MicroBooNE by a liquid argon filtration system

We report the MicroBooNE liquid argon time projection chamber (LArTPC) maintains a high level of liquid argon purity through the use of a filtration system that removes electronegative contaminants in continuously-circulated liquid, recondensed boil off, and externally supplied argon gas. We use the MicroBooNE LArTPC to reconstruct MeV-scale radiological decays. Using this technique we measure the liquid argon filtration system's efficacy at removing radon. This is studied by placing a 500 kBq 222 Rn source upstream of the filters and searching for a time-dependent increase in the number of radiological decays in the LArTPC. In the context of two models for radon mitigation via a liquid argon filtration system, a slowing mechanism and a trapping mechanism, MicroBooNE data supports a radon reduction factor of greater than 97% or 99.999%, respectively. Furthermore, a radiological survey of the filters found that the copper-based filter material was the primary medium that removed the 222 Rn. This is the first observation of radon mitigation in liquid argon with a large-scale copper-based filter and could offer a radon mitigation solution for future large LArTPCs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correcting beam space charge effects in Active-Target Time Projection Chamber

By providing a large gaseous volume for nuclear interactions while simultaneously recording the tracks of resulting reaction products, an active target serves as both a thick target and a detector. Once a reaction occurs, the emitted charged fragments strip electrons from the target gas along their path as they transverse the detector. Collection of these stripped electrons allow for detection of the product tracks. As beam intensity increases, the resulting ionization in the active target can significantly distort this collection of electrons. If left uncorrected, the resulting measurements could be wrong. In this paper, we investigate the impact of the space charge produced by heavy radioactive beams within the Active Target - Time Projection Chamber at Michigan State University. The beams are injected parallel to the electric field of the time projection chamber which is operated without a magnetic field for this experiment. Furthermore, we analyze the rate dependence of the space charge effects and demonstrate that they can be modeled and effectively corrected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ALICE-USA Barrel Tracking Upgrade (Project Final Report)

The ALICE-USA Barrel Tracking Upgrade (BTU) project began in 2015 to participate in a major upgrade of the Time Projection Chamber (TPC) and the Inner Tracking System (ITS) of the ALICE Experiment at CERN in Geneva, Switzerland. This upgrade increased the maximum readout rate of the ALICE detector to accommodate the increased heavy ion interaction rates following Long Shutdown 2 of the Large Hadron Collider, and greatly improved the vertexing performance of the detector. The original scope was completed and reviewed in November 2019. The BTU project document BTU.19.v1 "ALICE Barrel Tracking Upgrade Project Closeout / Transition to Operations (2019)" from November 2019 describes the status in detail and is attached as Appendix 1 below. At that point, all delivery milestones had been met on time, all Key Performance Parameters (KPPs) of the project had been satisfied, and the project was under budget. Several subsequent No Cost Extensions (NCEs) supported integration and pre-commissioning of the BTU project deliverables at CERN, as well as study and assessment of performance with Pb-Pb collisions at 50 kHz. The BTU project was successfully completed on 30 September 2024.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50

DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV=c 2 mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows us to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionization yield of electronic recoils down to ~180 eV er , exploiting 37 Ar and 39 Ar decays, and extrapolated to a few ionization electrons with the Thomas-Imel box model. Further, we present a model-dependent determination of the ionization response to nuclear recoils down to ~500 eV nr , the lowest ever achieved in liquid argon, using in situ neutron calibration sources and external datasets from neutron beam experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhancing Neutrino Event Reconstruction with Pixel-Based 3D Readout for Liquid Argon Time Projection Chambers

In this paper we explore the potential improvements in neutrino event reconstruction that a 3D pixelated readout could offer over a 2D projective wire readout for liquid argon time projection chambers. We simulate and study events in two generic, idealized detector configurations for these two designs, classifying events in each sample with deep convolutional neural networks to compare the best 2D results to the best 3D results. In almost all cases we find that the 3D readout provides better reconstruction efficiency and purity than the 2D projective wire readout, with the advantages of 3D being particularly evident in more complex topologies, such as electron neutrino charged current events. We conclude that the use of a 3D pixelated detector could significantly enhance the reach and impact of future liquid argon TPC experiments physics program, such as DUNE.

Adams, C↗

Investigation of background electron emission in the LUX detector

Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of signals from electron emission processes in the low energy region. While this background negatively impacts detector performance in various ways, its origins have only been partially studied. In this paper, we report a systematic investigation of the electron pathologies observed in the LUX dark matter experiment. We characterize different electron populations based on their emission intensities and their correlations with preceding energy depositions in the detector. By studying these electron backgrounds under different experimental conditions, we identified the possible mechanisms that may contribute to the electron emission. We report the observed electron event rate in LUX after background rejection, and discuss how such backgrounds can be further mitigated in ongoing and future xenon-based dark matter experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast spark-detection system for GEM detectors

The sPHENIX experiment is currently under commissioning at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Lab (BNL). The Time Projection Chamber (TPC) serves as a tracking detector for the experiment. The sPHENIX TPC uses a stack of four Gas Electron Multipliers (GEMs) as a gain stage in a reduced ion back-flow configuration. To mitigate the damaging effects of sparks in the GEMs, an online spark monitoring system was created. Once the system detects a spark in a GEM stack, the voltages across the GEMs in that stack can be lowered to prevent further sparking without affecting the gain and efficiency of the other modules. Spark signals are coupled out of the GEM stack by a pick-off capacitor attached to the bottom of the bottom GEM. Custom PCBs convert the oscillatory spark signal into a mono-polar pulse that is then digitized. The software then saves the waveform in a server and uses experimentally derived thresholds to determine how to react. As a result, the system has so far proven to be effective at improving the stability of the TPC and preventing damaging events while collecting cosmic ray data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Elimination LArTPC Simulation Uncertainty

Liquid Argon Time Projection Chambers (LArTPC) are crucial for measuring muons and neutrinos by capturing the paths of fast-moving particles through argon gas. However, these detectors face challenges such as electron-ion recombination, diffusion, and attenuation, which introduce uncertainties in simulation models. This study, conducted by Ka ren Mkrtchyan at FERMILAB, aims to reduce these uncertainties by adjusting the amplitude and width of signals detected by the TPC wires. Initial findings indicate that the current modification algorithm requires further refinement to better align simulations with observed data. Ongoing work focuses on correcting computational bugs and enhancing the simulation model for improved accuracy and statistical confidence.

Mkrtchyan, Ka'ren↗

Machine learning methods for fission product identification from Bragg curves

A fission time projection chamber (fission-TPC) was developed to provide precise neutron-induced fission measurements for several major actinides. As fission fragments lose energy in one of the gas volumes of the fission-TPC, energy loss information is captured and may be used to determine fission product yields as the stopping power of an ion is dependent on the atomic number. The work presented here demonstrates the ability to apply machine learning techniques for Bragg curve classification. A set of one million energy loss curves for 24 different fission-fragment elements was generated using common stopping power software. A ResNet architecture optimized for 1D data was used to train, test, and validate a model for light and heavy fission fragments using the simulated data. The resultant classification accuracy for the light and heavy fragments indicates that this could be a viable method for elemental classification of data from the fission-TPC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development and Performance Verification of a TPC Polarimeter for High Energy X-rays

We present the first application of a time projection chamber polarimeter to measure high energy X-ray polarization above 10 keV. The polarimeter is designed based on the PRAXyS soft X-ray polarimeter. The sealed gas is changed to a gas mixture of 60% argon and 40% dimethyl ether at 1 atm to be sensitive to high energy X-rays. The polarimeter performance is verified with linearly polarized, monochromatic X-rays at a synchrotron radiation facility, KEK Photon Factory BL-14A. The measured modulation factors are 42.4±0.6%, 50.4±0.6%,and 55.0±0.6% at 12, 14, and 16 keV, respectively, and the measured polarization angles are consistent with the expected values at all energies.

Tomoshi Takeda↗