Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

High-resolution 3D-printed plastic scintillators with tertiary dye

Additive manufacturing offers efficient production of plastic scintillators with nontrivial geometries using vat polymerization, allowing fabrication of geometries which would be difficult or even impossible to produce using conventional subtractive manufacturing. This work presents a novel photocurable scintillator formula that includes coumarin 450 as a tertiary dye to enable high-resolution 3D printing via the manipulation of the 405 nm cure light. Bulk photocured and 3D printed (with and without tertiary dye) samples were compared through observational assessment and spectral response. All samples showed pulse shape discrimination between neutron and gamma events. Inclusion of the tertiary dye has minimal impact on emission spectrum and light output, but significant impact on print resolution as shown by comparison of printed high-complexity geometries and feature resolution test objects. With the use of a cure-limiting dye, unsupported features — such as freestanding pillars — were resolvable down to 0.7 mm. Even finer resolution at or below 0.1 mm was achieved in fully supported, integrated structures printed with off-the-shelf 405 nm desktop 3D printer. Scintillators demonstrated a light output up to 50% of EJ-200 with a PSD figure of merit up to 1.35 at 0.9–1.1 MeVee.

36 MATERIALS SCIENCE↗

PMT calibration for the JSNS^2-II far detector with an embedded LED system

The JSNS^2-II (the second phase of JSNS^2, J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment aimed at searching for sterile neutrinos. Here, this experiment has entered its second phase, employing two liquid scintillator detectors located at near and far positions from the neutrino source. Recently, the far detector of the experiment has been completed and is currently in the calibration phase. The following properties of all functioning Photo-Multiplier-Tubes (PMTs) to detect the neutrino events in the far detector have been calibrated: PMT gain, its dependence of supplied High Voltage (HV), Peak-to-Valley (PV), and signal timing. This paper presents a detailed description of the calibration process utilizing the LED system. The LED system of the far detector uses two Ultra-Violet (UV) LEDs, which are effective in calibrating all of the PMTs at once. The UV light is converted into the visible light wavelengths inside liquid scintillator via the wavelength shifters, providing pseudo-isotropic light. To achieve a good energy resolution for physics events, a relative gain adjustment of up to 10% is required for all functioning PMTs. This will be achieved using the HV curves measured and the results of the LED calibration. The Peak-to-Valley (PV) ratio values, which distinguish the single photo-electron signal from the pedestal, are similar to those from the production company. Additionally, the precision of the PMT signal timing is measured to be 2.1 ns. This meets the event reconstruction requirement of 10 ns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Muon tracking in a LiquidO opaque scintillator detector

LiquidO is an innovative radiation detector concept. The core idea is to exploit stochastic light confinement in a highly scattering medium to self-segment the detector volume. In this paper, we demonstrate event-by-event muon tracking in a LiquidO opaque scintillator detector prototype. The detector consists of a 30 mm cubic scintillator volume instrumented with 64 wavelength-shifting fibres arranged in an 8 × 8 grid with a 3.2 mm pitch and read out by silicon photomultipliers. A wax-based opaque scintillator with a scattering length of approximately 0.5 mm is used. The tracking performance of this LiquidO detector is characterised with cosmic-ray muons and the position resolution is demonstrated to be 450 μm per row of fibres. These results highlight the potential of LiquidO opaque scintillator detectors to achieve fine spatial resolution, enabling precise particle tracking and imaging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling light signals using data from the first pulsed neutron source program at the DUNE vertical drift ColdBox test facility at the CERN Neutrino Platform

In this paper, we present a first quantitative test of detected light signals produced in a pulsed neutron source run in a small vertical drift LArTPC at the CERN Neutrino Platform ColdBox test facility. The ColdBox cryostat, detectors, neutron sources, and particle interactions are modeled and simulated using Fluka. We demonstrate the ability to identify the contribution from neutron interactions using X-ARAPUCA photodetectors, and show first comparisons of data to simulation, which indicate reasonable agreement. A time constant is also fitted from the neutron-beam-off light signal spectrum and found consistent between data and simulation. Several important systematic effects are discussed and serve as guides for future runs at larger LArTPCs.

Detector modelling and simulations I (interaction ↗

Demonstrating Safeguards Applications of DRiFT Gas Detector Capabilities [Slides]

DRiFT, a Detector Response Function Toolkit, post-processes MCNP output to model detector response. Three primary components: scintillator (focus of FY 21 TED work), gas detectors (focus of this FY), and semiconductor detectors. Capability to model scintillator detectors has previously been demonstrated.

47 OTHER INSTRUMENTATION↗

Secondary scintillation properties of multi-layer THGEMs operated in low-pressure CF 4 and Ar/5%Xe

We present a measurement of the secondary scintillation yield produced by two-layer Thick Gas Electron Multipliers (M-THGEMs) in pure Tetrafluoromethane (CF 4 ) gas and in Ar mixed with 5% Xe in low-pressures down to 20 Torr. The detector was irradiated with 5.49 MeV alpha particles from a low-rate 241-Am source. The secondary scintillation light generated during the gas avalanche process was read out by a Hamamatsu photomultiplier tube (model R8520-406), sensitive to a broad wavelength range (160–650 nm). The avalanche charge was collected on the bottom electrode of M-THGEM and correlated to the scintillation light on an event-by-event basis. We observed that, for both gas types, the value of the photon to electron production ratio (0.4 ph/el in CF 4 and 0.1 ph/el in Ar/5%Xe) increases with the thickness of the M-THGEM electrodes and varies significantly with the pressure, being higher at lower values. The decrease in electroluminescence yield at higher pressures is much more pronounced in the Ar/Xe mixture. In addition, because of a larger gas avalanche volume, the electroluminescence light yield is larger in thicker M-THGEM structures. Presented results are particularly useful for designing the next generation of Optical-readout Time Projection Chambers (O-TPCs) operated at low-pressure CF 4 ; applications include experimental nuclear physics with rare isotope beams, dark matter detection with directional sensitivity and observation of the Migdal effect in a low-pressure Optical TPC.

47 OTHER INSTRUMENTATION↗

Operation and performance of a dual-phase crystalline/vapor xenon time projection chamber

We have built and operated a crystalline/vapor xenon TPC, with the goal of improving searches for dark matter. The motivation for this instrument is the fact that beta decays from the radon decay chain to the ground state presently limit the state-of-the-art liquid/vapor xenon experiments. In contrast, a crystalline xenon target has the potential to exclude, or tag and reject radon-chain backgrounds. As a preamble to demonstrating such capabilities, the present article makes a first demonstration of the operation of a crystalline/vapor xenon TPC with electroluminescence (gas gain) for the electron signal readout. It also shows that the scintillation yield in crystalline xenon appears to be identical to that in liquid xenon, in contrast to previous results.

47 OTHER INSTRUMENTATION↗

Investigating Gadolinium-Lined Sodium-Iodide Neutron Detectors for Mobile Applications

For enhancing the effectiveness of nonproliferation efforts in neutron detection, most portable instruments rely on 6 Li scintillators, 10 B-based detectors, or gas-filled 3 He proportional counters. Additionally, gamma-ray detectors based on scintillators and semiconductors are often employed for search applications to find radioactive material in the field. These systems typically include dedicated detectors along with separate high voltage supplies and processing electronics for the gamma-ray and neutron detectors. Ideally, a portable radiation detection system should be lightweight, compact, and cost-effective. In the field, scintillators can serve a dual purpose: (1) detecting gamma-rays and (2) detecting neutrons. Gamma-ray detection with scintillators is based on the interaction of gamma-rays within the scintillating material, whereas neutron detection depends indirectly on neutron capture events. These capture events generate conversion electrons and gamma-rays, which can interact with the scintillator. For enhancing neutron capture, the scintillator can be surrounded by neutron absorber materials with a high neutron cross section. The resulting secondary electrons and gamma-rays from neutron interactions, depending on the absorber material used, can then be analyzed to detect the presence of neutron sources. Similarly, semiconductor-based detectors can be employed along with neutron absorbers as liners for neutron detection. 158 Gd has a significantly larger neutron cross section than 3 He, commonly used in gas-filled proportional counters, as shown in Figure 1. For thermal (0.025 eV) neutrons, the absorption cross section of 158 Gd is 10,000 times greater than that of 3 He (refer to Figure 1). This feature makes naturally occurring gadolinium, which consists of 24.8% 158 Gd, a promising neutron absorber material for use in combination with gamma-ray detectors–yielding a hybrid detector–for neutron detection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Mitigation of backgrounds from cosmogenic 137 Xe in xenon gas experiments using 3 He neutron capture

136 Xe is used as the target medium for many experiments searching for 0νββ. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of 137 Xe created by the capture of neutrons on 136 Xe. This isotope decays via beta decay with a half-life of 3.8 minutes and a Q β of ~4.16 MeV. This work proposes and explores the concept of adding a small percentage of 3 He to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from 137 Xe activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct thermal neutron detection by the 2D semiconductor 6 LiInP 2 Se 6

Highly efficient neutron detectors are critical in many sectors, including national security, medicine, crystallography and astronomy. The main neutron detection technologies currently used involve 3 He-gas-filled proportional counters and light scintillators for thermalized neutrons. Semiconductors could provide the next generation of neutron detectors because their advantages could make them competitive with or superior to existing detectors. In particular, solids with a high concentration of high-neutron-capture nuclides (such as 6 Li, 10 B) could be used to develop smaller detectors with high intrinsic efficiencies. However, no promising materials have been reported so far for the construction of direct-conversion semiconductor detectors. Here we report on the semiconductor LiInP 2 Se 6 and demonstrate its potential as a candidate material for the direct detection of thermal neutrons at room temperature. This compound has a good thermal-neutron-capture cross-section, a suitable bandgap (2.06 electronvolts) and a favourable electronic band structure for efficient electron charge transport. We used α particles from an 241 Am source as a proxy for the neutron-capture reaction and determined that the compact two-dimensional (2D) LiInP 2 Se 6 detectors resolved the full-energy peak with an energy resolution of 13.9 per cent. Direct neutron detection from a moderated Pu–Be source was achieved using 6 Li-enriched (95 per cent) LiInP 2 Se 6 detectors with full-peak resolution. Here, we anticipate that these results will spark interest in this field and enable the replacement of 3 He counters by semiconductor-based neutron detectors.

36 MATERIALS SCIENCE↗

Observation of d(t,n) α Neutrons Following d(d,p)t Reactions in a Deuterium Gas Cell: An Attempt to Repeat Ruhlig’s 1938 Observation of Secondary Reactions

In order to benchmark methods used to calculate reaction-in-flight fusion reactions in inertial confinement fusion and address issues related to the first claimed observation of d(t,n)α reactions in 1938, secondary d(t,n)α reactions have been observed following d(d,p)t reactions in deuterium gas. A pulsed 200-nA, 2.2-MeV deuterium beam from the Triangle Universities Nuclear Laboratory FN tandem accelerator was injected into a cylindrical multiatmosphere deuterium gas target. The incident beam traversed along the target cylinder’s 3-cm symmetry axis after its passage through a Havar entrance foil. Two different Havar foil thicknesses were used to obtain 1.5- and 0.6-MeV deuteron beams entering the deuterium cell. The cylinder’s radius was 2 cm to allow for d(d,p)t tritons emitted perpendicular to the beam to range out in the deuterium gas. The neutron emission from the cell was observed via its time of flight to a liquid scintillator placed at various angles to the beam direction, at a distance of 243 cm. Pulse-shape-discrimination techniques were used to separate neutron and gamma-ray signals seen in the liquid scintillator. The observed probability of ~2 × 10 –4 for inducing secondary d(t,n)α fusion in the gas cell per d(d,p)t reaction is consistent with theoretical expectations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The MIGDAL experiment: Measuring a rare atomic process to aid the search for dark matter

We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to detect the predicted atomic electron emission which is thought to accompany nuclear scattering with low, but calculable, probability, by deploying an Optical Time Projection Chamber filled with a low-pressure gas based on CF 4 . Initially, pure CF 4 will be used, and then in mixtures containing other elements employed by leading dark matter search technologies — including noble species, plus Si and Ge. High resolution track images generated by a Gas Electron Multiplier stack, together with timing information from scintillation and ionisation readout, will be used for 3D reconstruction of the characteristic event topology expected for this process — an arrangement of two tracks sharing a common vertex, with one belonging to a Migdal electron and the other to a nuclear recoil. Different energy-loss rate distributions along both tracks will be used as a powerful discrimination tool against background events. In this article we present the design of the experiment, informed by extensive particle and track simulations and detailed estimations of signal and background rates. In pure CF 4 we expect to observe 8.9 (29.3) Migdal events per calendar day of exposure to an intense D–D (D–T) neutron generator beam at the NILE facility located at the Rutherford Appleton Laboratory (UK). With our nominal assumptions, 5σ median discovery significance can be achieved in under one day with either generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

Analysis of 83m Kr prompt scintillation signals in the PIXeY detector

Prompt scintillation signals from 83m Kr calibration sources are a useful metric to calibrate the spatial variation of light collection efficiency and electric field magnitude of a two phase liquid-gas xenon time projection chamber. Because 83m Kr decays in two steps, there are two prompt scintillation pulses for each calibration event, denoted S1a and S1b. We study the ratio of S1b to S1a signal sizes in the Particle Identification in Xenon at Yale (PIXeY) experiment and its dependence on the time separation between the two signals (Δ t), notably its increase at low Δ t. Finally, in PIXeY data, the Δ t dependence of S1b/S1a is observed to exhibit two exponential components: one with a time constant of 0.05 ± 0.02 μ s, which can be attributed to processing effects and pulse overlap and one with a time constant of 10.2 ± 2.2 μs that increases in amplitude with electric drift field, the origin of which is not yet understood.

47 OTHER INSTRUMENTATION↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Reduction of detection limit and quantification uncertainty due to interferent by neural classification with abstention

Many measurements in the physical sciences can be cast as counting experiments, where the number of occurrences of a physical phenomenon informs the prevalence of the phenomenon's source. Often, detection of the physical phenomenon (termed signal) is difficult to distinguish from naturally occurring phenomena (termed background). In this case, the discrimination of signal events from background can be performed using classifiers, and they may range from simple, threshold-based classifiers to sophisticated neural networks. These classifiers are often trained and validated to obtain optimal accuracy, however we show that the optimal accuracy classifier does not generally coincide with a classifier that provides the lowest detection limit, nor the lowest quantification uncertainty. Here, we present a derivation of the detection limit and quantification uncertainty in the classifier-based counting experiment case. We also present a novel abstention mechanism to minimize the detection limit or quantification uncertainty a posteriori. We illustrate the method on two data sets from the physical sciences, discriminating Ar-37 and Ar-39 radioactive decay from non-radioactive events in a gas proportional counter, and discriminating neutrons from gammas in an inorganic scintillator and report results therefrom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗