Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency scans”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Real-time dynamic calibration of a tunable frequency laser source using a Fabry-Pérot interferometer

We report on a method for real-time dynamic calibration of a tunable external cavity diode laser by using a partially mode-matched plano-concave Fabry-Pérot interferometer in reflection geometry. Wide range laser frequency scanning is carried out by piezo-driven tilting of a diffractive grating playing the role of a frequency selective mirror in the laser cavity. The grating tilting system has a considerable mechanical inertness, so static laser frequency calibration leads to false results. The proposed real-time dynamic calibration based on the identification of primary- and Gouy-effect type secondary interference peaks with known frequency and temporal history can be used for a wide scanning range (from 0.2 GHz to more than 1 GHz). A concave spherical mirror with a radius of R = 100 cm and a plain 1% transmitting mirror was used as a Fabry-Pérot interferometer with various resonator lengths to investigate and demonstrate real-time calibration procedures for two kinds of laser frequency scanning functions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AVIRIS scan drive design and performance

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) images the ground with an instantaneous field of view (IFOV) of 1 mrad. The IFOV is scanned 30 deg from left to right to provide the cross-track dimension of the image, while the aircraft's motion provides the along-track dimension. The scanning frequency is 12 Hz, with a scan efficiency of 70 percent. The scan mirror has an effective diameter of 5.7 in, and its positional accuracy is a small fraction of a milliradian of the nominal position-time profile. Described are the design and performance of the scan drive mechanism. Tradeoffs among various approaches are discussed, and the reasons given for the selection of the cam drive.

Miller, D. C.↗

AVIRIS scan drive design and performance

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) images the ground with an instantaneous field of view (IFOV) of 1 mrad. The IFOV is scanned 30 deg from left to right to provide the cross-track dimension of the image, while the aircraft's motion provides the along-track dimension. The scanning frequency is 12 Hz, with a scan efficiency of 70 percent. The scan mirror has an effective diameter of 5.7 in, and its positional accuracy is a small fraction of a milliradian of the nominal position-time profile. Described are the design and performance of the scan drive mechanism. Tradeoffs among various approaches are discussed, and the reasons given for the selection of the cam drive.

Miller, D. C.↗

Developing a narrow-line laser spectrometer based on a tunable continuous-wave dye laser

We present the development of a dye-laser-based spectrometer operating at 550–600 nm. The spectrometer will be used to detect an ultra-narrow clock transition ({sup 1}S{sub 0}-{sup 3}P{sub 0}) in an Ytterbium optical lattice clock and perform high-resolution spectroscopy of iodine molecules trapped in the sub-nanometer channels of zeolite crystal (AlPO{sub 4}-11). Two-stage Pound-Drever-Hall frequency stabilization is implemented on the tunable continuous-wave dye laser to obtain a reliable operation and provide stable laser radiations with two different spectral linewidths. In the first-stage frequency locking, a compact home-built intracavity electro-optic modulator is adopted for suppressing fast frequency noise. With an acquisition time of 0.1 s the 670-kHz linewidth of the free-running dye laser is reduced to 2 kHz when locked to a pre-stabilization optical cavity with a finesse of 1170. When the pre-stabilized laser is locked to a high-finesse optical cavity, a linewidth of 1.4 Hz (2 s) is observed and the frequency stability is 3.7 × 10{sup −15} (3 s). We also measure and analyze the individual noise contributions such as those from residual amplitude modulation and electronic noise. The ongoing upgrades include improving long-term frequency stability at time scales from 10 to 100 s and implementing continuous frequency scan across 10 GHz with radio-frequency precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Testing Framework for Grid-Forming Resources: Preprint

This paper presents a testing framework for grid-forming (GFM) resources. It first analytically derives in frequency domain the active and reactive power response of an ideal voltage source with a reactor. These transfer functions are then used to quantify the voltage source behavior expected from a GFM inverter within subtransient time scales (5-10 cycles) following a grid disturbance. The paper also shows that the testing of a GFM inverter might require a reactor of an appropriate size between the inverter and the grid simulator used for the inverter testing. Finally, the paper presents a systematic approach for developing specifications for GFM resources using active and reactive power response frequency scans. The testing framework and results presented in this paper are demonstrated using EMT simulations of a 1-MW GFM inverter.

frequency scans↗

A Testing Framework for Grid-Forming Resources

This paper presents a testing framework for grid-forming (GFM) resources. First, it analytically derives in the frequency domain the active and reactive power response of an ideal voltage source with a reactor. These transfer functions are then used to quantify the voltage source behavior expected from a GFM inverter within subtransient timescales (5-15 cycles) following a grid disturbance. The paper also shows that the testing of a GFM inverter might require a reactor of an appropriate size between the inverter and the grid simulator used for the inverter testing. Finally, the paper presents a systematic approach for developing specifications for GFM resources using active and reactive power response frequency scans. The testing framework and results presented in this paper are demonstrated using EMT-PSCAD simulations of a 1-MW GFM inverter.

frequency scans↗

DQ Admittance Extraction for Inverter-Based Resources

The power grid industry is pushing for electromagnetic transient (EMT)-based studies for generation interconnection and planning process due to high penetrations of inverter-based resource (IBRs). Vendor-specific and site-specific black-box IBR models are preferred in those simulation studies. For small-signal analysis, measurement-based admittance models are necessary. In this paper, we demonstrate the extraction of frequency-domain dq frame IBR models. These linear models are specific to operating conditions. We demonstrate two extraction methods: frequency scan and a step response-based method. The latter relies on converting time-domain responses to Laplace-domain expressions via eigensystem realization analysis (ERA). Both can lead to dq admittance representation and the latter is time saving.

admittance model↗

DQ Admittance Extraction for Inverter-Based Resources: Preprint

The power grid industry is pushing for electro-magnetic transient (EMT)-based studies for generation interconnection and planning process due to high penetrations of inverter-based resource (IBRs). Vendor-specific and site-specific black-box IBR models are preferred in those simulation studies. For small-signal analysis, measurement-based admittance models are necessary. In this paper, we demonstrate the extraction of frequency-domain dq frame IBR models. These linear models are specific to operating conditions. We demonstrate two extraction methods: frequency scan and a step response-based method. The latter relies on converting time-domain responses to Laplace-domain expressions via eigensystem realization analysis (ERA). Both can lead to dq admittance representation and the latter is time saving.

admittance model↗

Compositing Ground Penetrating Radar Scans of Differing Frequencies for Better Depth Perception

Methods developed to reduce interference in a noisy environment, be it radar target responses or effective communications in the presence of noise for mobile phone users, are vital in delivering a clear usable signal. The methods used to render a cleaner signal can also be used to combine signals of various frequencies. Ground Penetrating Radar (GPR) scans over the same area are no exception. This paper explores using an optimization problem solver, the Expectation Maximization (EM) Algorithm, to define the weights to use to combine multiple GPR scans at different frequencies over the same target area. This approach exploits the Gaussian Mixture Model (GMM) feature of the EM algorithm to produce a cleaner image at depth. Our method demonstrates a measured improvement toward producing a cleaner image.

97 MATHEMATICS AND COMPUTING↗

On the possibility of designing a high-resolution heterodyne spectrometer for near-IR range on the basis of a tunable diode laser

The results of heterodyning of broadband radiation in the near-IR range are presented. A stabilised DFB laser was used as a local oscillator, while the role of a broadband radiation source was played by another DFB laser, excited by the pump current below its threshold value. A fibre-optical Y-coupler based on the single-mode silica fibre served as a diplexer. The radiation mixed in the singlemode fibre was incident on the photodetector, the role of which was played by a p - i - n photodiode. The signal from the photodiode was amplified by the preamplifier with the feedback resistance 240 k{Omega} and the bandwidth {approx}1 MHz and then digitised using a 16-digit ADC. The frequency scanning was implemented via the variation of the local oscillator frequency. The developed registration system provides the sensitivity {approx}1.4 % of the shot noise value at the acquisition time {approx}40 min.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Flaw detection by mechanical resonant measurement

Testing technique is based on analysis of varying frequency scan applied to measured samples. Any changes in resonant-frequency harmonics detected in samples are used to indicate size of fault. Testing apparatus uses drive mechanism to apply vibrating force to sample. Force is applied longitudinally along axis to eliminate directionality on flexural vibrations.

Buck, O.↗

On Utilization of NEXRAD Scan Strategy Information to Infer Discrepancies Associated With Radar and Rain Gauge Surface Volumetric Rainfall Accumulations

To evaluate the Tropical Rainfall Measuring Mission (TRMM) monthly Ground Validation (GV) rain map, 42 quality controlled tipping bucket rain gauge data (1 minute interpolated rain rates) were utilized. We have compared the gauge data to the surface volumetric rainfall accumulation of NEXRAD reflectivity field, (converting to rain rates using a 0.5 dB resolution smooth Z-R table). The comparison was carried out from data collected at Melbourne, Florida during the month of July 98. GV operational level 3 (L3 monthly) accumulation algorithm was used to obtain surface volumetric accumulations for the radar. The gauge records were accumulated using the 1 minute interpolated rain rates while the radar Volume Scan (VOS) intervals remain less than or equal to 75 minutes. The correlation coefficient for the radar and gauge totals for the monthly time-scale remain at 0.93, however, a large difference was noted between the gauge and radar derived rain accumulation when the radar data interval is either 9 minute, or 10 minute. This difference in radar and gauge accumulation is being explained in terms of the radar scan strategy information. The discrepancy in terms of the Volume Coverage Pattern (VCP) of the NEXRAD is being reported where VCP mode is ascertained using the radar tilt angle information. Hourly radar and gauge accumulations have been computed using the present operational L3 method supplemented with a threshold period of +/- 5 minutes (based on a sensitivity analysis). These radar and gauge accumulations are subsequently improved using a radar hourly scan weighting factor (taking ratio of the radar scan frequency within a time bin to the 7436 total radar scans for the month). This GV procedure is further being improved by introducing a spatial smoothing method to yield reasonable bulk radar to gauge ratio for the hourly and daily scales.

Roy, Biswadev↗

Thrust Measurement of Dielectric Barrier Discharge (DBD) Plasma Actuators: New Anti-Thrust Hypothesis, Frequency Sweeps Methodology, Humidity and Enclosure Effects

We discuss thrust measurements of Dielectric Barrier Discharge (DBD) plasma actuators devices used for aerodynamic active flow control. After a review of our experience with conventional thrust measurement and significant non-repeatability of the results, we devised a suspended actuator test setup, and now present a methodology of thrust measurements with decreased uncertainty. The methodology consists of frequency scans at constant voltages. The procedure consists of increasing the frequency in a step-wise fashion from several Hz to the maximum frequency of several kHz, followed by frequency decrease back down to the start frequency of several Hz. This sequence is performed first at the highest voltage of interest, then repeated at lower voltages. The data in the descending frequency direction is more consistent and selected for reporting. Sample results show strong dependence of thrust on humidity which also affects the consistency and fluctuations of the measurements. We also observed negative values of thrust, or "anti-thrust", at low frequencies between 4 Hz and up to 64 Hz. The anti-thrust is proportional to the mean-squared voltage and is frequency independent. Departures from the parabolic anti-thrust curve are correlated with appearance of visible plasma discharges. We propose the anti-thrust hypothesis. It states that the measured thrust is a sum of plasma thrust and anti-thrust, and assumes that the anti-thrust exists at all frequencies and voltages. The anti-thrust depends on actuator geometry and materials and on the test installation. It enables the separation of the plasma thrust from the measured total thrust. This approach enables more meaningful comparisons between actuators at different installations and laboratories. The dependence on test installation was validated by surrounding the actuator with a grounded large-diameter metal sleeve. Strong dependence on humidity is also shown; the thrust significantly increased with decreasing humidity, e.g., 44 percent increase as relative humidity changed from 18 percent and dew point 33 degF to 50 percent and dew point of 57 degF.

Ashpis, David E.↗

Dielectric Barrier Discharge (DBD) Plasma Actuators Thrust-Measurement Methodology Incorporating New Anti-Thrust Hypothesis

We discuss thrust measurements of Dielectric Barrier Discharge (DBD) plasma actuators devices used for aerodynamic active flow control. After a review of our experience with conventional thrust measurement and significant non-repeatability of the results, we devised a suspended actuator test setup, and now present a methodology of thrust measurements with decreased uncertainty. The methodology consists of frequency scans at constant voltages. The procedure consists of increasing the frequency in a step-wise fashion from several Hz to the maximum frequency of several kHz, followed by frequency decrease back down to the start frequency of several Hz. This sequence is performed first at the highest voltage of interest, then repeated at lower voltages. The data in the descending frequency direction is more consistent and selected for reporting. Sample results show strong dependence of thrust on humidity which also affects the consistency and fluctuations of the measurements. We also observed negative values of thrust or "anti-thrust", at low frequencies between 4 Hz and up to 64 Hz. The anti-thrust is proportional to the mean-squared voltage and is frequency independent. Departures from the parabolic anti-thrust curve are correlated with appearance of visible plasma discharges. We propose the anti-thrust hypothesis. It states that the measured thrust is a sum of plasma thrust and anti-thrust, and assumes that the anti-thrust exists at all frequencies and voltages. The anti-thrust depends on actuator geometry and materials and on the test installation. It enables the separation of the plasma thrust from the measured total thrust. This approach enables more meaningful comparisons between actuators at different installations and laboratories. The dependence on test installation was validated by surrounding the actuator with a large diameter, grounded, metal sleeve.

Ashpis, David E.↗

Switched steerable multiple beam antenna system

A steerable multibeam five element cross-feed cluster antenna system is described. The feed power is divided into five branches. Each branch includes a switching network comprised of a plurality of time delay elements each individually controlled by a respective electromagnetic latching switch. Frequency independent individual two-dimensional beam steering at intermediate (IF) scanning frequencies is thereby provided wherein discrete incremental time delays are introduced by the switching networks into each branch and the signals recombined thereafter to form each beam. The electromagnetic latched switching reduces power consumption and permits higher power switching and reciprocal coincident tranmsit and receive operation. Frequency independence due to incremental time delay switching permits coincident reciprocal operation and steering for transmit-receive signal paths carrying different transmit-receive frequencies. Diagonal quarter wave plates in the waveguides alter polarization from the circular to orthogonal linear to provide transmitter-receiver isolation.

Richard S Iwasaki↗

Application of a neural network as a potential aid in predicting NTF pump failure

The National Transonic Facility has three centrifugal multi-stage pumps to supply liquid nitrogen to the wind tunnel. Pump reliability is critical to facility operation and test capability. A highly desirable goal is to be able to detect a pump rotating component problem as early as possible during normal operation and avoid serious damage to other pump components. If a problem is detected before serious damage occurs, the repair cost and downtime could be reduced significantly. A neural network-based tool was developed for monitoring pump performance and aiding in predicting pump failure. Once trained, neural networks can rapidly process many combinations of input values other than those used for training to approximate previously unknown output values. This neural network was applied to establish relationships among the critical frequencies and aid in predicting failures. Training pairs were developed from frequency scans from typical tunnel operations. After training, various combinations of critical pump frequencies were propagated through the neural network. The approximated output was used to create a contour plot depicting the relationships of the input frequencies to the output pump frequency.

Rogers, James L.↗

Interpreting the behavior of a quarter-wave transmission line resonator in a magnetized plasma

The quarter wave resonator immersed in a strongly magnetized plasma displays two possible resonances occurring either below or above its resonance frequency in vacuum, f{sub o}. This fact was demonstrated in our recent articles [G. S. Gogna and S. K. Karkari, Appl. Phys. Lett. 96, 151503 (2010); S. K. Karkari, G. S. Gogna, D. Boilson, M. M. Turner, and A. Simonin, Contrib. Plasma Phys. 50(9), 903 (2010)], where the experiments were carried out over a limited range of magnetic fields at a constant electron density, n{sub e}. In this paper, we present the observation of dual resonances occurring over the frequency scan and find that n{sub e} calculated by considering the lower resonance frequency is 25%–30% smaller than that calculated using the upper resonance frequency with respect to f{sub o}. At a given magnetic field strength, the resonances tend to shift away from f{sub o} as the background density is increased. The lower resonance tends to saturate when its value approaches electron cyclotron frequency, f{sub ce}. Interpretation of these resonance conditions are revisited by examining the behavior of the resonance frequency response as a function of n{sub e}. A qualitative discussion is presented which highlights the practical application of the hairpin resonator for interpreting n{sub e} in a strongly magnetized plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Voltage scanning and technical upgrades at the Collinear Resonance Ionization Spectroscopy experiment

To optimize the performance of the Collinear Resonance Ionization Spectroscopy (CRIS) experiment at CERN-ISOLDE, technical upgrades are continuously introduced, aiming to enhance its sensitivity, precision, stability, and efficiency. Recently, a voltage-scanning setup was developed and commissioned at CRIS, which improved the scanning speed by a factor of three as compared to the current laser-frequency scanning approach. This leads to faster measurements of the hyperfine structure for systems with high yields (more than a few thousand ions per second). Additionally, several beamline sections have been redesigned and manufactured, including a new field-ionization unit, an electrostatic bend with a larger deflection angle, and improved ion optics. The beamline upgrades are expected to yield an improvement of at least a factor of 5 in the signal-to-noise ratio by avoiding the use of high-power lasers (which yield non-resonantly produced ions) and providing time-of-flight separation between the resonant ions and the collisional background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗