Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow velocity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Skin cooling maintains cerebral blood flow velocity and orthostatic tolerance during tilting in heated humans

Orthostatic tolerance is reduced in the heat-stressed human. The purpose of this project was to identify whether skin-surface cooling improves orthostatic tolerance. Nine subjects were exposed to 10 min of 60 degrees head-up tilting in each of four conditions: normothermia (NT-tilt), heat stress (HT-tilt), normothermia plus skin-surface cooling 1 min before and throughout tilting (NT-tilt(cool)), and heat stress plus skin-surface cooling 1 min before and throughout tilting (HT-tilt(cool)). Heating and cooling were accomplished by perfusing 46 and 15 degrees C water, respectively, though a tube-lined suit worn by each subject. During HT-tilt, four of nine subjects developed presyncopal symptoms resulting in the termination of the tilt test. In contrast, no subject experienced presyncopal symptoms during NT-tilt, NT-tilt(cool), or HT-tilt(cool). During the HT-tilt procedure, mean arterial blood pressure (MAP) and cerebral blood flow velocity (CBFV) decreased. However, during HT-tilt(cool), MAP, total peripheral resistance, and CBFV were significantly greater relative to HT-tilt (all P < 0.01). No differences were observed in calculated cerebral vascular resistance between the four conditions. These data suggest that skin-surface cooling prevents the fall in CBFV during upright tilting and improves orthostatic tolerance, presumably via maintenance of MAP. Hence, skin-surface cooling may be a potent countermeasure to protect against orthostatic intolerance observed in heat-stressed humans.

Clinical Trial↗

Cerebral blood flow velocity and cranial fluid volume decrease during +Gz acceleration

Cerebral blood flow (CBF) velocity and cranial fluid volume, which is defined as the total volume of intra- and extracranial fluid, were measured using transcranial Doppler ultrasonography and rheoencephalography, respectively, in humans during graded increase of +Gz acceleration (onset rate: 0.1 G/s) without straining maneuvers. Gz acceleration was terminated when subjects' vision decreased to an angle of less than or equal to 60 degrees, which was defined as the physiological end point. In five subjects, mean CBF velocity decreased 48% from a baseline value of 59.4 +/- 11.2 cm/s to 31.0 +/- 5.6 cm/s (p<0.01) with initial loss of peripheral vision at 5.7 +/- 0.9 Gz. On the other hand, systolic CBF velocity did not change significantly during increasing +Gz acceleration. Cranial impedance, which is proportional to loss of cranial fluid volume, increased by 2.0 +/- 0.8% above the baseline value at the physiological end point (p<0.05). Both the decrease of CBF velocity and the increase of cranial impedance correlated significantly with Gz. These results suggest that +Gz acceleration without straining maneuvers decreases CBF velocity to half normal and probably causes a caudal fluid shift from both intra- and extracranial tissues.

NASA Discipline Cardiopulmonary↗

Development of a Rayleigh Scattering Diagnostic for Time-Resolved Gas Flow Velocity, Temperature, and Density Measurements in Aerodynamic Test Facilities

A molecular Rayleigh scattering technique is developed to measure time-resolved gas velocity, temperature, and density in unseeded turbulent flows at sampling rates up to 32 kHz. A high power continuous-wave laser beam is focused at a point in an air flow field and Rayleigh scattered light is collected and fiber-optically transmitted to the spectral analysis and detection equipment. The spectrum of the light, which contains information about the temperature and velocity of the flow, is analyzed using a Fabry-Perot interferometer. Photomultiplier tubes operated in the photon counting mode allow high frequency sampling of the circular interference pattern to provide time-resolved flow property measurements. An acoustically driven nozzle flow is studied to validate velocity fluctuation measurements, and an asymmetric oscillating counterflow with unequal enthalpies is studied to validate the measurement of temperature fluctuations. Velocity fluctuations are compared with constant temperature anemometry measurements and temperature fluctuations are compared with constant current anemometry measurements at the same locations. Time-series and power spectra of the temperature and velocity measurements are presented. A numerical simulation of the light scattering and detection process was developed and compared with experimental data for future use as an experiment design tool.

Mielke, Amy F.↗

Molecular Rayleigh Scattering Techniques Developed for Measuring Gas Flow Velocity, Density, Temperature, and Turbulence

Nonintrusive optical point-wise measurement techniques utilizing the principles of molecular Rayleigh scattering have been developed at the NASA Glenn Research Center to obtain time-averaged information about gas velocity, density, temperature, and turbulence, or dynamic information about gas velocity and density in unseeded flows. These techniques enable measurements that are necessary for validating computational fluid dynamics (CFD) and computational aeroacoustic (CAA) codes. Dynamic measurements allow the calculation of power spectra for the various flow properties. This type of information is currently being used in jet noise studies, correlating sound pressure fluctuations with velocity and density fluctuations to determine noise sources in jets. These nonintrusive techniques are particularly useful in supersonic flows, where seeding the flow with particles is not an option, and where the environment is too harsh for hot-wire measurements.

Mielke, Amy F.↗

Cerebral blood flow velocity in humans exposed to 24 h of head-down tilt

This study investigates cerebral blood flow (CBF) velocity in humans before, during, and after 24 h of 6 deg head-down tilt (HDT), which is a currently accepted experimental model to simulate microgravity. CBF velocity was measured by use of the transcranial Doppler technique in the right middle cerebral artery of eight healthy male subjects. Mean CBF velocity increased from the pre-HDT upright seated baseline value of 55.5 +/- 3.7 (SE) cm/s to 61.5 +/- 3.3 cm/s at 0.5 h of HDT, reached a peak value of 63.2 +/- 4.1 cm/s at 3 h of HDT, and remained significantly above the pre-HDT baseline for over 6 h of HDT. During upright seated recovery, mean CBF velocity decreased to 87 percent of the pre-HDT baseline value. Mean CBF velocity correlated well with calculated intracranial arterial pressure (IAP). As analyzed by linear regression, mean CBF velocity = 29.6 + 0.32IAP. These results suggest that HDT increases CBF velocity by increasing IAP during several hours after the onset of microgravity. Importantly, the decrease in CBF velocity after HDT may be responsible, in part, for the increased risk of syncope observed in subjects after prolonged bed rest and also in astronauts returning to Earth.

Kawai, Y.↗

New Sensors For Flow Velocity And Acoustics

Paper describes two sensor-development programs at Fluid Mechanics Laboratory at NASA Ames Research Center. One program for digital image velocimetry (DIV) sensors, and other program, for advanced acoustic sensors for wind tunnels. DIV measures, in real time, instantaneous velocity fields of time-varying flow or of collection of objects moving with varying velocities. Advanced acoustic sensors for wind tunnels being developed to reduce effects of interference from wind noise, noise from interactions between flows and sensors, flow-induced vibrations of sensors, deflections of accoustic waves by boundary layers induced by sensors, and reflections from walls and sensor supports.

Cho, Y. C.↗

Flow velocities and streamlines

Computer program calculates subsonic or transonic flow on hubshroud, midchannel, stream surface of single-blade row of turbomachine. Program uses finite-different and quasi-orthogonal (velocity-gradient) methods. Program is reported in two volumes: Part I is User's Manual, Part II is Programmer's Manual.

Katsanis, T.↗

Direct Measurement of Internal Flow Velocities in a Star-Slot Model

This paper presents the results of a cold flow experiment to make direct measurements of the velocity distribution in a model of a solid rocket motor star grain propellant slot. The experimental procedure utilizes a multi-component laser Doppler velocimeter (LDV) and an apparatus for seeding the flow with aluminum particles to determine the velocity components at various discrete locations within the star slot. The test article used in this investigation was a one-tenth scale, cold flow model based on the geometry of the Space Shuttle solid rocket motor head-end section. The results obtained for the direct measurements of velocity are compared to velocities calculated from measured pressure distributions to data obtained from oil smear experiments and flow visualization videos, and to heat transfer calorimeter data.

Foster, Winfred A., Jr.↗

Flow velocity measurements with stimulated Rayleigh-Brillouin-gain spectroscopy

Using stimulated Rayleigh-Brillouin-gain spectroscopy, velocity measurements in an atmospheric-pressure subsonic nitrogen flow with 10 percent uncertainty have been conducted. It is shown that the accuracy of the velocity measurements increases with gas pressure, making this spectroscopic technique ideal for measuring velocity and other parameters of high-pressure (greater than 1-atm) atomic or molecular flows.

Herring, G. C.↗

Very low velocity flow sensor uses fluidic techniques

Parallel-flow wind sensor provides differential pressure output which is nearly linear and relatively insensitive to supply pressure over a wide range of wind velocities. Cross-flow wind sensor outputs are input to a fluidic amplifier to obtain high pressure output for low wind velocities without changing output characteristics.

Turek, R. F.↗

A submerged singularity method for calculating potential flow velocities at arbitrary near-field points

A discrete singularity method has been developed for calculating the potential flow around two-dimensional airfoils. The objective was to calculate velocities at any arbitrary point in the flow field, including points that approach the airfoil surface. That objective was achieved and is demonstrated here on a Joukowski airfoil. The method used combined vortices and sources ''submerged'' a small distance below the airfoil surface and incorporated a near-field subvortex technique developed earlier. When a velocity calculation point approached the airfoil surface, the number of discrete singularities effectively increased (but only locally) to keep the point just outside the error region of the submerged singularity discretization. The method could be extended to three dimensions, and should improve nonlinear methods, which calculate interference effects between multiple wings, and which include the effects of force-free trailing vortex sheets. The capability demonstrated here would extend the scope of such calculations to allow the close approach of wings and vortex sheets (or vortices).

Maskew, B.↗

Flow velocity measurements by image processing of optically activated tracers

A computerized flow visualization technique capable of quantifying the flow field automatically has been developed. This technique uses afterglowing effect of optically activated phosphorescent particles to retrieve vectorial information on each trace. By using this information, in conjunction with computer image processing, the flow field of a free surface transient vortex was investigated.

Gharib, M.↗

Measurement accuracy of flow velocity via a digital-frequency-counter laser velocimeter processor

The laser velocimeter (LV) technique has so far been successfully applied to many flow situations to obtain mean velocity and turbulence level measurements. The paper deals with a unique LV system employing a digital frequency counter for measurements of turbulence spectra within the objectives of achieving higher accuracies and a wider range of velocities than were possible by previous analog systems. Systematic analysis of the effects of LV system errors in the accuracy of the turbulence power spectral measurements is performed and shown to agree reasonably with the experimental LV spectra results. Sufficient understanding of the accuracy and limitations of the digital frequency counter LV spectral measurement system is obtained. Among the major system errors encountered in a typical digital frequency counter LV processor, the truncation error is regarded as the most serious source of error. The quantizing step size defined as the ratio of Doppler frequency to processor clock frequency is an important parameter in determining the dynamic range of a turbulence power spectrum.

Wang, J. C. F.↗

Development of Hydroxyl Tagging Velocimetry for Low Velocity Flows

Hydroxyl tagging velocimetry (HTV) is a molecular tagging technique that relies on the photo-dissociation of water vapor into OH radicals and their subsequent tracking using laser induced fluorescence. Velocities are then obtained from time-of-flight calculations. At ambient temperature in air, the OH species lifetime is relatively short (<50 μs), making it suited for high speed flows. Lifetime and radicals formation increases with temperature, which allows HTV to also probe low-velocity, high-temperature flows or reacting flows such as flames. The present work aims at extending the domain of applicability of HTV, particularly towards low-speed (<10 m/s) and moderate (<500 K) temperature flows. Results are compared to particle image velocimetry (PIV) measurements recorded in identical conditions. Single shot and averaged velocity profiles are obtained in an air jet at room temperature. By modestly raising the temperature (100-200 degC) the OH production increases, resulting in an improvement of the signal-to-noise ratio (SNR). Use of nitrogen - a non-reactive gas with minimal collisional quenching - extends the OH species lifetime (to over 500 μs), which allows probing of slower flows or, alternately, increases the measurement precision at the expense of spatial resolution. Instantaneous velocity profiles are resolved in a 100degC nitrogen jet (maximum jet-center velocity of 6.5 m/s) with an uncertainty down to 0.10 m/s (1.5%) at 68% confidence level. MTV measurements are compared with particle image velocimetry and show agreement within 2%.

Andre, Matthieu A.↗

A holographic interferometer system for measuring density profiles in high-velocity flows

This paper describes a holographic interferometric technique for obtaining density measurements across a test gas that is traveling at a velocity of over 5500 m/sec in an expansion tube facility. Interferometric data describing the flow in the test section are obtained using a long coherence length CW argon laser in a holographic system and a rotating drum camera recorder. The object beam, which passes through the test section, intersects the reference beam at a small angle to form an interference pattern of about 170 lines/mm, and is recorded as a hologram. Before a test, this hologram is placed in its original position and rotated slightly so that an interference pattern is generated by the intersection of the reconstructed and real-time object beams.

Burner, A. W.↗

A Holographic Interferometer System for Measuring Density Profiles in High-Velocity Flows

This paper describes a holographic interferometric technique for obtaining density measurements across a test gas that is traveling at a velocity of over 5500 meters per second in an expansion tube facility. Interferometric data describing the flow in the test section are obtained using a long coherence length cw argon laser in a holographic system and a rotating drum camera recorder. The object beam, which passes through the test section, intersects the reference beam at a small angle (5 degrees) to form an interference pattern of about 170 lines per millimeter, and is recorded as a hologram. Before a test, this hologram is placed in its original position and rotated slightly so that an interference pattern is generated by the intersection of the reconstructed and real-time object beams. This interference pattern is adjusted to a series of bright, horizontal fringes having a spatial frequency of about 5 fringes per centimeter. During the few milliseconds it takes the test gas to pass through the test section, variations in the gas density across the 8.4-centimeter test section produce phase variations in the object beam and result in a varying interference pattern. A rotating drum camera with a 0.15-millimeter slit aligned perpendicular to the fringes is used to record the varying fringe shifts with a time resolution of about 3 microseconds. The average gas density across the test section is determined by measuring these fringe shifts.

Burner, Alpheus W.↗