Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Experimental Investigation of a Phase Change Material Charged Serpentine Heat Exchanger with Louvered Fins

Phase change material heat exchangers (PCM-HX) can be used as a latent heat thermal energy storage (LHTES) component in heat pump applications to further enhance the efficiency of a heat pump as well as to yield financial savings by peak-load shifting. In this paper, a low-cost commercially available aluminum serpentine heat exchanger with louvered fins was experimentally investigated to check its thermal performance as a PCM-HX. A transparent rectangular box fabricated from acrylic plates served as a PCM container. Two cameras were used to capture the phase change process of the PCM on the front and top sides of the container during the experiment. A total of 88 installed temperature sensors throughout the test setup and a mass flow meter enabled a quantitative analysis of the PCM-HX as well. The energy balance deviation between the estimated theoretical and experimentally calculated PCM storage was ±14% considering the often-neglected heat loss and thermal mass of the PCM-HX. PCM temperature profiles, charge and discharge rates, and energy densities under different test conditions were also investigated.

42 ENGINEERING↗

Hydrogen, Methane, Brine Flow Behavior, and Saturation in Sandstone Cores During H 2 and CH 4 Injection and Displacement

Large-scale underground hydrogen storage (UHS) is a critical component in the emerging hydrogen economy. Knowledge of multiphase flow behavior involving hydrogen in storage reservoir formations is crucial to characterizing hydrogen transport properties and essential for the deliverability and storage operations of UHS. There are still many gaps in fully understanding hydrogen–methane–brine multiphase phase flow that require further investigation. In this work, H 2 and CH 4 were injected through brine-saturated sandstone cores using a tri-axial core holder system fitted with flow rate meters and pressure transducers, while the effluent gas concentrations were analyzed using an online micro gas chromatograph. Brine displacement, permeability, and gas breakthrough curves were measured. We studied the flow behavior of hydrogen and methane in sandstone cores through testing brine displacement by gas injection and comparing the hydrogen displacement of methane with the methane displacement of hydrogen. We also tested the differences between horizontal and vertical flow in brine displacement. The results showed that brine displacement was more efficient in a core with higher permeability and porosity, resulting in a higher initial gas saturation. A higher gas injection rate brought about faster gas breakthrough measured by pore volume and sharper concentration curves. Hydrogen did not exhibit abnormal flow in the sandstone when the flow was horizontal and downward vertical. Gas overriding was observed in brine displacements when the flow was horizontal, with hydrogen showing this behavior more profoundly compared to methane. Downward vertical gas injection induced higher efficiency brine displacement compared to horizontal displacement and resulted in a higher initial gas saturation in the sandstone cores. These findings address critical knowledge gaps regarding gas flow patterns and displacement behaviors during hydrogen injection and recovery phases in UHS facilities using methane as the cushion gas. The insights from this research offer valuable guidance for optimizing UHS systems, ensuring operational efficiency, and advancing sustainable energy solutions in alignment with decarbonization goals.

08 HYDROGEN↗

Experimental characterization and potential energy savings of insulated cladding for U.S. residential buildings

This study evaluates a novel insulated cladding composed of foamed cement and vinyl siding that is designed as a retrofit product to enhance thermal performance in U.S. residential buildings. Experimental measurements showed that foamed cement exhibits a thermal conductivity of 0.0334–0.0365 W/m-K (R-value of 4.0–4.3 °F⋅ft 2 ⋅h/BTU), which is significantly higher than that of conventional fiber cement boards. Although mechanical testing confirmed the material’s brittleness and low strength, it also indicated its suitability for nonstructural insulation applications. Water vapor permeability testing demonstrated effective moisture resistance with the polymer coating. To evaluate the insulated cladding’s energy performance, we used the U.S. Department of Energy’s prototype single-family building model and simulated across 50 locations spanning 16 International Energy Conservation Code climate zones. The R-7 (R-value of 7 °F⋅ft 2 ⋅h/BTU per inch) retrofit cladding resulted in heating energy savings up to 275 therms (Fairbanks, AK) and cooling energy savings up to 1,547 kWh (Phoenix, AZ). The energy cost savings varied by region, but the highest annual cost savings ($\$$434/year) were observed in Santa Maria, CA, and the highest annual cost savings percentage (37 %) were noted in Monterey, CA. On a national scale, the insulated retrofit provided an average annual energy cost reduction of 16 %, highlighting the cladding system’s broad applicability and financial viability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental investigation of unsteady flow dynamics in therminol-66 using edge tone-induced oscillations

Recent research has demonstrated that flow oscillations induced by a wedge positioned opposite the jet outlet in edge tones can be effectively utilized for flow measurement purposes. This highlights the necessity for developing advanced instrumentation capable of precise flow measurements in experimental setups exposed to radiation and in challenging fluids such as molten salts. Here, this study contributes to the existing body of knowledge by conducting experiments using Therminol-66, an effective surrogate for FLiBe under appropriate temperature conditions for nuclear applications, across a broad range of Reynolds numbers from 17,700 to 555,000. Experiments were conducted with Therminol-66 at approximately 368.8 K under atmospheric pressure, with varying flow rates. A reliable correlation was established between the generated frequencies, corresponding flow rates, and device geometry parameters. The data were subjected to non-dimensional analysis to reveal the interrelationships among flow rate, fluid properties, device geometry, and their impact on the acoustic tones produced by the edge tone device. These findings contribute to the development of precise flow measurement instrumentation for use in challenging environments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Sampling in Long-Screened Wells: Issues, Misconceptions, and Solutions

The issues associated with long-screened wells (LSWs) (and open boreholes) at contaminated sites are well documented in the groundwater literature but are still not fully appreciated in practice. As established in seminal and review papers going back over three decades, the interpretation of sampling results from LSWs is challenging in the presence of vertical hydraulic gradients and borehole flow; furthermore, LSWs allow for vertical redistribution of contamination between aquifer layers. Acknowledgment of these issues has led to the development of new technologies and well designs to enable discrete-zone monitoring (DZM), yet LSWs remain common for many reasons, for example, as multipurpose wells, for geophysical logging, and (or) as legacy installations. Despite the literature on LSWs and despite the adoption of DZM at many sites, the use of LSWs persists and the challenges of interpreting sampling results from LSWs remain. In this issue paper, we provide a conceptual overview of the problems posed by LSWs and review existing literature and past work to improve the interpretation of sampling in LSWs. We draw on experience from previous studies at the Hanford Site in eastern WA, USA, and use synthetic examples to illustrate key concepts and challenges for interpretation. A recently published analytical modeling framework is used to develop illustrative synthetic examples and demonstrate a workflow for building scientific intuition to understand issues around interpreting samples from LSWs, which is critical to effective characterization and groundwater remediation at sites with LSWs.

54 ENVIRONMENTAL SCIENCES↗

Development of an Advanced Hydrogen Energy Storage System using Aerogel in a Cryogenic Flux Capacitor

The Cryogenic Flux Capacitor (CFC) is a cold, dense fluid storage core with integrated design features that afford the designer flexibility and provide new possibilities for the storage and discharge of energy. The stored energy, in this case, is represented by hydrogen physically bonded within the nanoscale pores within the aerogel composite blanket material, and the process of bonding or debonding is governed by the principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m 2 /g) allows for storage densities close to, or in some cases exceeding, that of normal boiling point liquids. Its performance easily exceeds what can be achieved via ambient temperature and high-pressure gas storage for an equivalent volume. CFC storage is predicted to be easily scalable, constructed from readily available commercial materials, and lends itself to a range of pressure applications. The project team designed and manufactured the CFC, integrating it into a set of temperature-controlled flow loops. The CFC test setup was validated against existing data from previous NASA work. Tests used bottled hydrogen gas for test validation. A cryogenic fluid, nitrogen, flowed through a metered control system. Hydrogen temperature, pressure, and flow rates, as well as the temperature control targets, provided all necessary control targets. The team analyzed the recorded data and updated the Technology Maturation Plan based on the results of the test, making recommendations for a follow-up test, scale-up, and maturation pathway. For the engineering development and maturation of CFC hydrogen storage technology, a Techno-Economic Assessment (TEA) and Commercialization Plan for the integration of this technology with various power generation assets were produced. A companion analytical model was developed, experimentally validated, compared against performance metric, and used to tune the model and scale up the technology.

08 HYDROGEN↗

Polymer-based microfluidic device for on-chip counter-diffusive crystallization and in situ X-ray crystallography at room temperature

Proteins are long chains of amino acid residues that perform a myriad of functions in living organisms, including enzymatic reactions, signalling, and maintaining structural integrity. Protein function is determined directly by the protein structure. X-ray crystallography is the primary technique for determining the 3D structure of proteins, and facilitates understanding the effects of protein structure on function. The first step towards structure determination is crystallizing the protein of interest. We have developed a centrifugally-actuated microfluidic device that incorporates the fluid handling and metering necessary for protein crystallization. Liquid handling takes advantage of surface forces to control fluid flow and enable metering, without the need for any fluidic or pump connections. Our approach requires only the simple steps of pipetting the crystallization reagents into the device followed by either spinning or shaking to set up counter-diffusive protein crystallization trials. The use of thin, UV-curable polymers with a high level of X-ray transparency allows for in situ X-ray crystallography, eliminating the manual handling of fragile protein crystals and streamlining the process of protein structure analysis. We demonstrate the utility of our device using hen egg white lysozyme as a model system, followed by the crystallization and in situ, room temperature structural analysis of the hub domain of calcium–calmodulin dependent kinase II (CaMKIIβ).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of sequential stimulation practices on geochemical alteration of shale

Water-based hydraulic fracturing fluids (HFFs) can chemically interact with formation shale, resulting in altered porosity and permeability of the host rock. Experimental investigations of spatial and temporal shale-HFF interactions are helpful in interpreting chemical compositions of the injectate, as well as predicting alteration of hydraulic properties in the reservoir due to mineral dissolution and precipitation. Most bench-top experiments designed to study shale-HFF chemical interactions, either using batch reactors or flow-through setups, are carried out assuming that the acid spearhead has already become mixed with neutral HFFs. During operations, however, HFFs are typically injected according to a sequenced pumping schedule, starting with a concentrated acid spearhead, followed by multiple additions of near-neutral pH HFFs containing chemical amendments and proppant. In this study, we use geochemical modeling to consider whether this pre-mixed experimental protocol provides results directly comparable to a sequential discrete fluid-shale interaction protocol. Our results show that for the batch system, the transient evolution in major ion concentrations is faster with the sequential procedure. After 2 h of reaction time, the two protocols converge to the same aqueous concentrations. In a flow-through geometry, the pre-mixed model predicts extensive chemical alteration close to the injection point but negligible alteration downstream. In contrast, the sequential model predicts mineral reactions over hundreds of meters along the flow path. The extent of shale alteration in the sequential model at a given location depends on shale mineralogy and where the acid spearhead resides during the shut-in period. The predictive model developed in this study can help experimentalists to design bench-top tests and operators to better translate the results of laboratory experiments into practical applications.

Li, Qingyun↗

Scale-Up and Modeling Efforts Using an Omniphobic Surface Treatment for Mitigating Solids Deposition

Abstract Gas hydrates, waxes and asphaltenes represent some of the most significant flow assurance challenges, especially in subsea lines, where treatment options can be limited. Currently, complete avoidance is the primary strategy for hydrate management, while chemical or mechanical flushing/pigging may be utilized for other solids. Each system must also be treated with individualized solutions, as there have been no proved one-size-fits-all technologies demonstrated to date. As an alternative to constant chemical injection or thermodynamic controls such as insulation or heating, a robust omniphobic surface treatment material has been developed which has been shown in previous studies to significantly reduce the adhesion of flow assurance solids, resulting in lower risk for deposition and plugging of gas hydrates, waxes, and asphaltenes. As part of a Department of Energy study, laboratory scale tests were performed on a variety of apparatuses ranging from micromechanical force (micron scale) to laboratory flow loop testing (meter scale). While the results from these tests have been promising, there can be some disconnects between lab-scale observations and field-scale testing. Several factors can result in discrepancies between small-scale bench-top studies and deployment-scale efforts. These include flow conditions (Reynolds number, flow regime), chemistry (synthetic vs. crude oils, gas composition, and additives), physical differences (pipeline material, size, and geometry), etc. This work will describe the actions taken to better understand the deployment and performance of a material such as this omniphobic surface treatment in field scenarios, and to build confidence for deployment in a production scenario. These efforts include modeling field production scenarios using models developed from lab observations, application of the material to field-scale equipment to better understand application challenges, and expanded survivability and longevity testing. Understanding the bridge between laboratory testing and full-scale deployment allows for better technique and risk mitigation for field scale testing.

03 NATURAL GAS↗

Performance of cross-flow turbines with varying blade materials and unsupported blade span

Cross-flow turbines could play a larger role in the diversification of the global energy supply if the impact of more cost-competitive design choices on performance and rotor dynamics was better understood. This study focuses on rotor performance and blade strain measurements while varying the following parameters: blade materials and blade free end length by changing strut support position. Towing tank experiments were performed with a modular 1-meter diameter cross-flow turbine consisting of three NACA 0018 blades with two support struts. One strut was fixed at the lower end of the turbine, while the second strut was adjustable, thereby changing the length of the free end. The blade materials tested were carbon, E-glass, and hollow E-glass fiber composites, in decreasing order of stiffness and cost. High-resolution distributed fiber optic sensors were embedded in two of the three rotor blades for each material and provided hundreds of strain measurements per blade. Turbine performance and blade strain were measured while varying tow speed and tip speed ratio. Performance tests were conducted at towing speeds sufficiently high for the performance to be independent of Reynolds number. E-glass blades and carbon blades performed similarly for the most rigid strut configurations. Higher strain was measured on the E-glass blades, and their performance was reduced for less rigid configurations compared to the carbon fiber blades. The performance of the highly deflective hollow E-glass blades was lower overall and became even more degraded for longer unsupported blade span. Furthermore, the results provide insight into the use of various blade materials in cross-flow turbines and guidance on allowable free end length for each material type.

16 TIDAL AND WAVE POWER↗

Performance of three hydrophone flow shields in a tidal channel

Pseudosound caused by turbulent pressure fluctuations in fluid flow past a hydrophone, referred to as flow noise, can mask propagating sounds of interest. Flow shields can mitigate flow noise by reducing non-acoustic pressure fluctuations sensed by a hydrophone. We evaluate the performance of three hydrophone flow shields (two nylon fabrics and an oil-filled enclosure) in a tidal channel with peak current speed of 1.3 m s−1. All three flow shields reduced flow noise without attenuating propagating sound below 20 kHz. The oil-filled enclosure performed best, reducing flow noise by over 30 dB at frequencies below 40 Hz.

47 OTHER INSTRUMENTATION↗

Integration and Demonstration of Monitoring, Modeling, and Prediction of DV-1 Amendment Performance at the Bench Scale: DV-1 Amendment Demonstration

During fiscal years 2024 and 2025, the U.S. Department of Energy’s Hanford Field Office commissioned Pacific Northwest National Laboratory to conduct applied research aimed at reducing the cost, time, and uncertainty associated with in situ treatment of vadose zone contaminants at the Hanford Site. This report outlines the integration of three key research efforts into a meso-scale demonstration designed to advance field-scale solutions that aim to (1) optimize the delivery of chemical amendments to contaminated soils, (2) reduce uncertainty in amendment delivery performance assessment using advanced monitoring techniques, and (3) provide real-time insights into when and where amendment-induced precipitation reactions occur in the subsurface. To achieve these objectives, the tank-scale (~ 1 cubic meter) Geophysical Imaging of Flow and Transport (GIFT) system was developed. GIFT enables experimental testing of amendment delivery while incorporating automated multi-modal monitoring approaches, including pressure measurements, direct fluid sampling, and remote time-lapse geophysical imaging. The data generated from these monitoring techniques will serve as inputs for a generative artificial-intelligence-driven digital twin – a numerical simulation model designed to honor observed data while quantifying uncertainty in simulation accuracy. Using this simulator, researchers will refine an amendment injection strategy to maximize delivery efficiency within a low-permeability soil zone. Monitoring data will be interpreted through simulated outputs to enhance understanding of the injection process. The efficacy of this integrated approach will be evaluated through direct sampling at the conclusion of the experiment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

Impact of Janssen effect on thermal transport in granular flow

Using a modulated photothermal radiometry (MPR) technique capable of measuring thermal transport in particle beds, we find asymptotically increasing effective thermal conductivity and decreasing near-wall thermal resistance along gravity-driven downward granular flows through a 1-meter-long narrow vertical channel owing to the Janssen effect. The Janssen effect is confirmed by similar asymptotic trends from particle bed apparent mass measurements as well as separate MPR heat transfer measurements on stationary particle beds under compression at different heights of the channel with and without pressure screening. Furthermore, local heat transfer coefficient along the 1-meter-long channel was modeled based on measured spatially resolved thermal conductivity and near-wall thermal resistance due to the Janssen effect. This work reveals for the first time the impact of the over century-old Janssen effect on heat transfer in granular media. Furthermore, the results from this work can lead to a better understanding of heat transfer in granular flow.

14 SOLAR ENERGY↗