Development and Application of Weld Track Thermal Analysis for the Exploration Extravehicular Mobility Unit

NASA is studying the next generation of space suit for safe operations in space, from the International Space Station to the lunar surface as part of the Exploration Extravehicular Mobility Unit project. The backplate structure of the portable life support system (PLSS) serves as the attachment point for assembly of the PLSS and contains embedded cooling channels. The thermal loop plumbing assembly and backplate are combined into a single component such that the fluid lines run through the midplane of the backplate. The manufacturing of the Ti-6Al-4V backplate consists of machining channels into a plate, welding cover plates on each channel using an electron beam, and additional machining for excess material removal and final detail. Careful control of the electron beam weld process is necessary to completely seal cover plates, produce consistent weld tracks, and produce channels with uniform cross sections free of debris and defects. The backplate contains multiple weld channels with unique geometries. The weld process parameters include choosing the beam current and focus, accelerating voltage, travel speed, pause times between weld tracks, and sequence of weld tracks. A transient finite element thermal analysis was developed to provide support for choosing and controlling the weld process parameters to maintain a consistent melt pool along each of the weld tracks. A moving distributed heat source is modeled to represent the heat input generated by the electron beam. The heat source model is a critical input to the analysis for accurate temperature predictions during the weld process. A modified conical heat source was developed to account for the change in working distance between the backplate and cover plates. The geometry of the material being welded must be accounted for by the heat source model to define the correct energy input. The weld process control is designed according to the predicted thermal history and melt pool dimensions for each of the weld channels. The analysis model, modified heat source, temperature and melt pool predictions, application of the thermal data to the weld parameters, and comparison with micrograph cross-sections from weld trials will be discussed in this presentation.

Electron Beam Welding↗

In-Space Radiator Shape Optimization using Genetic Algorithms

Future space exploration missions will require the development of more advanced in-space radiators. These radiators should be highly efficient and lightweight, deployable heat rejection systems. Typical radiators for in-space heat mitigation commonly comprise a substantial portion of the total vehicle mass. A small mass savings of even 5-10% can greatly improve vehicle performance. The objective of this paper is to present the development of detailed tools for the analysis and design of in-space radiators using evolutionary computation techniques. The optimality criterion is defined as a two-dimensional radiator with a shape demonstrating the smallest mass for the greatest overall heat transfer, thus the end result is a set of highly functional radiator designs. This cross-disciplinary work combines topology optimization and thermal analysis design by means of a genetic algorithm The proposed design tool consists of the following steps; design parameterization based on the exterior boundary of the radiator, objective function definition (mass minimization and heat loss maximization), objective function evaluation via finite element analysis (thermal radiation analysis) and optimization based on evolutionary algorithms. The radiator design problem is defined as follows: the input force is a driving temperature and the output reaction is heat loss. Appropriate modeling of the space environment is added to capture its effect on the radiator. The design parameters chosen for this radiator shape optimization problem fall into two classes, variable height along the width of the radiator and a spline curve defining the -material boundary of the radiator. The implementation of multiple design parameter schemes allows the user to have more confidence in the radiator optimization tool upon demonstration of convergence between the two design parameter schemes. This tool easily allows the user to manipulate the driving temperature regions thus permitting detailed design of in-space radiators for unique situations. Preliminary results indicate an optimized shape following that of the temperature distribution regions in the "cooler" portions of the radiator. The results closely follow the expected radiator shape.

Hull, Patrick V.↗

Detailed Uncertainty Analysis of the ZEM-3 Measurement System

The measurement of Seebeck coefficient and electrical resistivity are critical to the investigation of all thermoelectric systems. Therefore, it stands that the measurement uncertainty must be well understood to report ZT values which are accurate and trustworthy. A detailed uncertainty analysis of the ZEM-3 measurement system has been performed. The uncertainty analysis calculates error in the electrical resistivity measurement as a result of sample geometry tolerance, probe geometry tolerance, statistical error, and multi-meter uncertainty. The uncertainty on Seebeck coefficient includes probe wire correction factors, statistical error, multi-meter uncertainty, and most importantly the cold-finger effect. The cold-finger effect plagues all potentiometric (four-probe) Seebeck measurement systems, as heat parasitically transfers through thermocouple probes. The effect leads to an asymmetric over-estimation of the Seebeck coefficient. A thermal finite element analysis allows for quantification of the phenomenon, and provides an estimate on the uncertainty of the Seebeck coefficient. The thermoelectric power factor has been found to have an uncertainty of +9-14 at high temperature and 9 near room temperature.

Seebeck effect↗

Uncertainty Analysis of Slug Calorimeters in the HyMETS Arc-Jet Facility

The objective of this work is to perform an uncertainty analysis of the deduced stagnation heat flux environment on a slug calorimeter for conditions that span the performance envelope of the Hypersonic Materials Environmental Test System arc-jet facility located at NASA Langley Research Center. Analytical solutions are developed for boundary-value problems on the slug element accounting for non-ideal effects, including spatial variation in the slug heat flux, multi-dimensional thermal conduction, and back-face losses, which departs from the state-of-the-art method derived from the American Society of Testing and Materials. Boundary-value problem definitions are informed by preliminary finite element thermal analysis of the slug calorimeter assembly (including both slug and housing) and just the slug element. The analytical solutions are presented in a general sense and in a truncated form from error analysis. Results are shown in optimizing and validating the analytical models against available slug back-face thermal data. The optimization results indicate that the appropriate epistemic uncertainty of the deduced stagnation heat flux on the slug calorimeter is at most±2.5% for both a high-and low-enthalpy test condition. In addition, a numerical approach is used to determine the aleatory (probabilistic) uncertainty component in the slug stagnation heat flux by applying a marching least-squares slope routine through the steady-state portion of the slug back-face thermal response. Results indicate a compromise between the number of samples and the filter frequency of slug back-face thermal data points when evaluating the standard deviation of the deduced stagnation heat flux statistics. When combining the mixed uncertainty, both aleatory and epistemic, the interval of uncertainty in the deduced stagnation heat flux is determined to be up to ±4%, which is at least a 60% reduction from the standard uncertainty used in the state-of-the-art method.

uncertainty↗

Thermal response of Space Shuttle wing during reentry heating

A structural performance and resizing (SPAR) finite element thermal analysis computer program was used in the heat transfer analysis of the space shuttle orbiter that was subjected to reentry aerodynamic heatings. One wing segment of the right wing (WS 240) and the whole left wing were selected for the thermal analysis. Results showed that the predicted thermal protection system (TPS) temperatures were in good agreement with the space transportation system, trajectory 5 (STS-5) flight-measured temperatures. In addition, calculated aluminum structural temperatures were in fairly good agreement with the flight data up to the point of touchdown. Results also showed that the internal free convection had a considerable effect on the change of structural temperatures after touchdown.

Gong, L.↗

Thermal response of Space Shuttle wing during reentry heating

A structural performance and resizing (SPAR) finite element thermal analysis computer program was used in the heat transfer analysis of the Space Shuttle Orbiter that was subjected to reentry aerodynamic heatings. One wing segment of the right wing (WS 240) and the whole left wing were selected for the thermal analysis. Results showed that the predicted thermal protection system (TPS) temperatures were in good agreement with the space transportation system, trajectory 5 (STS-5) flight-measured temperatures. In addition, calculated aluminum structural temperatures were in fairly good agreement with flight data up to the point of touchdown. Results also showed that the internal free convection has a considerable effect on the change of structural temperatures after touchdown.

Gong, L.↗

Effects of forced and free convections on structural temperatures of Space Shuttle Orbiter during reentry flight

Structural performance and resizing (SPAR) finite-element thermal analysis computer program was used in the heat transfer analysis of the Space Shuttle Orbiter wing subjected to reentry aerodynamic heating. With sufficient external forced convective cooling near the end of the heating cycle, the calculated surface temperatures of the thermal protection system (TPS) agree favorably with the flight data for the entire flight profile. However, the effects of this external forced convective cooling on the structural temperatures were found to be negligible. Both free convection and forced convection elements were introduced to model the internal convection effect of the cool air entering the Shuttle interior. The introduction of the internal free convection effect decreased the calculated wing lower skin temperatures by 20 F at most, 1200 sec after touchdown. If the internal convection is treated as forced convection, the calculated wing lower skin temperatures after touchdown can be reduced to match the flight-measured data very closely. By reducing the TPS thicknesses to certain effective thickness to account for the TPs gap heating, the calculated wing lower skin temperatures prior to touchdown can be raised to agree with the flight data perfectly.

Ko, William L.↗

Comparison of flight-measured and calculated temperatures on the space shuttle orbiter

Structural temperatures and thermal protection system surface temperatures were measured on the space shuttle during the flight of STS 5. The measured data are compared with values calculated at wing stations 134, 240, and 328 and at fuselage station 877. The theoretical temperatures were calculated using the structural performance and resizing finite element thermal analysis program. The comparisons show that the calculated temperatures are, generally, in good agreement with the measured data.

Gong, Leslie↗

Effect of internal convection and internal radiation on the structural temperatures of Space Shuttle Orbiter

Structural performance and resizing of the finite-element thermal analysis computer program was used in the reentry heat transfer analysis of the space shuttle orbiter. One midfuselage cross section and one midspan wing segment were selected to study the effects of internal convection and internal radiation on the structural temperatures. The effect of internal convection was found to be more prominent than that of internal radiation in the orbiter thermal analysis. Without these two effects, the calculated structural temperatures at certain stations could be as much as 45 to 90 percent higher than the measured values. By considering internal convection as free convection, the correlation between the predicted and measured structural temperatures could be improved greatly.

Ko, William L.↗

Stirling engine - Approach for long-term durability assessment

The approach employed by NASA Lewis for the long-term durability assessment of the Stirling engine hot-section components is summarized. The approach consists of: preliminary structural assessment; development of a viscoplastic constitutive model to accurately determine material behavior under high-temperature thermomechanical loads; an experimental program to characterize material constants for the viscoplastic constitutive model; finite-element thermal analysis and structural analysis using a viscoplastic constitutive model to obtain stress/strain/temperature at the critical location of the hot-section components for life assessment; and development of a life prediction model applicable for long-term durability assessment at high temperatures. The approach should aid in the provision of long-term structural durability and reliability of Stirling engines.

Tong, Michael T.↗

Design and Performance of the Terrestrial Planet Finder Coronagraph

Terrestrial Planet Finder Coronagraph, one of two potential architectures, is described. The telescope is designed to make a visible wavelength survey of the habitable zones of at least thirty stars in search of earth-like planets. The preliminary system requirements, optical parameters, mechanical and thermal design, operations scenario and predicted performance is presented. The 6-meter aperture telescope has a monolithic primary mirror, which along with the secondary tower, are being designed to meet the stringent optical tolerances of the planet-finding mission. Performance predictions include dynamic and thermal finite element analysis of the telescope optics and structure, which are used to make predictions of the optical performance of the system.

designs↗

An Experimental and Numerical Study of a Supersonic Burner for CFD Model Development

A laboratory scale supersonic burner has been developed for validation of computational fluid dynamics models. Detailed numerical simulations were performed for the flow inside the combustor, and coupled with finite element thermal analysis to obtain more accurate outflow conditions. A database of nozzle exit profiles for a wide range of conditions of interest was generated to be used as boundary conditions for simulation of the external jet, or for validation of non-intrusive measurement techniques. A set of experiments was performed to validate the numerical results. In particular, temperature measurements obtained by using an infrared camera show that the computed heat transfer was larger than the measured value. Relaminarization in the convergent part of the nozzle was found to be responsible for this discrepancy, and further numerical simulations sustained this conclusion.

Magnotti, G.↗

Composite Stiffened Panels: Part I - Stiffness, Thermal Expansion, and Thermal Bending Formulation for Finite Element Analysis

A method is presented for formulating stiffness terms and thermal coefficients of fiber-reinforced composite, stiffened panels for input to finite element analysis (FEA). The method is robust enough to handle panels with general cross sectional shapes, including those which are unsymmetric and/or unbalanced. New thermal coefficients are introduced to quantify panel response from through-the-thickness temperature gradients. Equations are defined for stiffness, thermal expansion, and thermal bending that consider the full complement of membrane, bending, membrane-bending coupling, and transverse shear behavior. A technique of implementing this capability with a single plane of shell finite elements using the MSC/NASTRAN(TradeMark) FEA program is revealed. Finally, an example of a composite, hat-stiffened panel is included to demonstrate errors that occur when an unsymmetric panel is symmetrically formulated as traditionally done. These erroneous values and the correct ones produced from the presented method are listed for the panel's stiffness matrices, thermal expansion and bending vectors, and the forces and moments that are thermally induced from in-plane and through-the-thickness temperature gradients.

Craig S Collier↗

Improved finite element methodology for integrated thermal structural analysis

An integrated thermal-structural finite element approach for efficient coupling of thermal and structural analyses is presented. New thermal finite elements which yield exact nodal and element temperature for one dimensional linear steady state heat transfer problems are developed. A nodeless variable formulation is used to establish improved thermal finite elements for one dimensional nonlinear transient and two dimensional linear transient heat transfer problems. The thermal finite elements provide detailed temperature distributions without using additional element nodes and permit a common discretization with lower order congruent structural finite elements. The accuracy of the integrated approach is evaluated by comparisons with analytical solutions and conventional finite element thermal-structural analyses for a number of academic and more realistic problems. Results indicate that the approach provides a significant improvement in the accuracy and efficiency of thermal stress analysis for structures with complex temperature distributions.

Dechaumphai, P.↗

A Taylor-Galerkin finite element algorithm for transient nonlinear thermal-structural analysis

A Taylor-Galerkin finite element solution algorithm for transient nonlinear thermal-structural analysis of large, complex structural problems subjected to rapidly applied thermal-structural loads is described. The two-step Taylor-Galerkin algorithm is an application of an algorithm recently developed for problems in compressible fluid dynamics. The element integrals that appear in the algorithm can be evaluated in closed form for two and three dimensional elements.

Thornton, Earl A.↗

Integrated finite element thermal-structural analysis with radiation heat transfer

An integrated approach for efficiently coupling thermal and stress analyses of structures with radiation heat transfer is presented. A new integrated one dimensional element based on a nodeless variable formulation is introduced. Lumped and consistent formulations of the nonlinear radiation heat transfer matrix are presented. The accuracy of the integrated approach is assessed by comparisons with analytical solutions and conventional finite element thermal-structural analyses. Results show that the nodeless variable thermal element yields accuracy equivalent to a higher order element but permits a common discretization with a lower order congruent structural element. The integrated element thus provides improved accuracy and efficiency of thermal stress analysis for structures with complex temperature distributions.

Thornton, E. A.↗

A Taylor-Galerkin finite element algorithm for transient nonlinear thermal-structural analysis

A Taylor-Galerkin finite element method for solving large, nonlinear thermal-structural problems is presented. The algorithm is formulated for coupled transient and uncoupled quasistatic thermal-structural problems. Vectorizing strategies ensure computational efficiency. Two applications demonstrate the validity of the approach for analyzing transient and quasistatic thermal-structural problems.

Thornton, E. A.↗

A Taylor-Galerkin finite element algorithm for transient nonlinear thermal-structural analysis

A Taylor-Galerkin finite element method for solving large, nonlinear thermal-structural problems is presented. The algorithm is formulated for coupled transient and uncoupled quasistatic thermal-structural problems. Vectorizing strategies ensure computational efficiency. Two applications demonstrate the validity of the approach for analyzing transient and quasistatic thermal-structural problems.

Thornton, E. A.↗