Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault location”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Spread Spectrum Time Domain Reflectivity for String Monitoring in PV Power Plants (Final Technical Report)

This final report describes the methods and results of applying Spread Spectrum Time Domain Reflectivity (SSTDR) for String Monitoring in PV Power Plants for DE-EE0008169. The project created a new system for both detecting and locating electrical faults in photovoltaic systems. In this work, we address photovoltaic electric faults that are both common and costly. Based on interviews with photovoltaic power plant owners, operators, and maintainers, three types of faults are common and of significant interest: disconnects, ground faults, and arc faults. Disconnects can originate from many sources. They are often due to everyday events, such as lawnmowing (accidentally running over a cable), animals eating through the cables, or degradation that occurs over time due to corrosion or general degradation. Ground faults occur when the cables (for example, due to frayed insolation) connect to the ground, relaying current into the ground. These faults are particularly problematic since the ground faults are often intermittent. That is, ground faults commonly appear during rain storms due to a change in soil conductivity and then disappear when the rain ends. This makes the ground fault difficult to find because while current systems can detect the overall change in voltage and current associated with a ground fault, technicians are necessary to locate the fault. As a result, ground faults may disappear before the technician arrives at the power plant. Hence, locating and fixing ground faults often require multiple trips. We also study arc faults, which can result when nearby conductors create an arc of electrical current through the air. While less common, arc faults can be extremely dangerous. The energetic electrical arc can cause fires and destroy equipment, costing significant damage. Overall all three types of faults cost owners and operators money, either from the destruction of equipment or from technician time. Furthermore, while devices exist for detecting ground faults (ground fault circuit interrupters) and arc faults (arc fault circuit interrupter), these systems only search patterns of electrical current that correspond to each fault. This information cannot be used to locate the fault. In addition, these protection systems experience nuisance trips due to nearby electromagnetic interference, such as from a lawn mower or other motors that produce significant amounts of electromagnetic radiation. Hence, the overall goal of this project is to create an SSTDR tool that provides photovoltaic power plants with more reliable fault detection in addition to the localization of faults. SSTDR works by transmitting electrical signals into the photovoltaic string. Those signals reflect from impedance discontinuities (i.e., disconnects, ground faults, and arc faults). These faults are then detected by measuring the presence of a reflection at the SSTDR and can be located by identifying the location of that reflection in time. In addition, unlike current protection systems, these systems do not experience nuisance trips since their low amplitude, high frequency, and coded signal can by analyzed without interference from the regular operational voltage on the photovoltaic string.

14 SOLAR ENERGY↗

A Parametric Reduced-Order Model for Inverter Short-Circuit Response in Protection Studies

This paper presents a reduced-order model (ROM) for grid-following (GFL) inverters that reproduces inverter fault current trajectories, including sub transients, transient, and steady-state phases, across a range of fault types, locations, and pre-fault operating points. . The proposed model is developed by: Constructing the positive- and negative-sequence current with parameterization fitted by large data training and fitting Validating using EMT simulation against EMT full model and demonstrating the ROM's capability to capture fault current magnitude, phase angle, and oscillatory transients. Building a standard EMT simulation platform library component for easy configuration and application.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids: Preprint

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Live State of Health Monitoring of Inverter Subsystems

This presentation talks about different failure modes and corresponding detection schemes of PV panels, PV inverters, electric machines such as motors and power converter. Several novel techniques have been presented that are capable of measuring degradation as well as detecting faults in various location in a PV based power system.

ENGINEERING,SOLAR ENERGY↗

A phased workflow to define permit‐ready locations for large volume CO 2 injection and storage

Abstract To‐date, only two UIC Class VI permits have been issued by the US Environmental Protection Agency. We illustrate a four‐phase workflow to first identify regional storage resources and then down‐select sites to yield permit‐ready locations that can accept and store large volumes of CO 2 . Specific permit requirements should guide objectives and define deliverables of respective workflow phases. In the first phase we used available regional data and screened structure and injection zones to locate resources that match CO 2 volumes planned to be captured. Available data were also used to assess presence and depth of usable groundwater, the key resource being protected via permitting. We then used advanced, closed‐form, analytical solutions (EASiTool) to estimate CO 2 injectivity into each hydrologically connected injection compartment. In the second phase we acquired and conditioned additional wireline logs and leased available seismic datasets. We interpreted the depositional systems from wireline well‐log character and mapped sandbody geometry to interpolate injection and confining‐zone distribution. Using available data, we mapped faults and locations of freshwater and overpressure (or other capacity‐limiting geologic parameters) in more detail. In the third phase, we used the augmented geologic data to develop a static model for the selected area, extracted the areas of highest interest, and generated and ran dynamic (flow) models. In a fourth phase, we reduced major uncertainties identified in earlier phases. Our case study indicates that to complete preparation of a permit application requires (1) improved lithologic characterization information (thicknesses and horizontal and vertical connectivity) and (2) better definition of poorly defined local faults. © 2023 The Authors. Greenhouse Gases: Science and Technology published by Society of Chemical Industry and John Wiley & Sons Ltd.

58 GEOSCIENCES↗

Real-Time Fault Tracking and Ground Motion Prediction for Large Earthquakes With HR-GNSS and Deep Learning

Earthquake early warning (EEW) systems aim to forecast the shaking intensity rapidly after an earthquake occurs and send warnings to affected areas before the onset of strong shaking. The system relies on rapid and accurate estimation of earthquake source parameters. However, it is known that source estimation for large ruptures in real-time is challenging, and it often leads to magnitude underestimation. In a previous study, we showed that machine learning, HR-GNSS, and realistic rupture synthetics can be used to reliably predict earthquake magnitude. This model, called Machine-Learning Assessed Rapid Geodetic Earthquake model (M-LARGE), can rapidly forecast large earthquake magnitudes with an accuracy of 99%. Here, we expand M-LARGE to predict centroid location and fault size, enabling the construction of the fault rupture extent for forecasting shaking intensity using existing ground motion models. We test our model in the Chilean Subduction Zone with thousands of simulated and five real large earthquakes. The result achieves an average warning time of 40.5 s for shaking intensity MMI4+, surpassing the 34 s obtained by a similar GNSS EEW model. Our approach addresses a critical gap in existing EEW systems for large earthquakes by demonstrating real-time fault tracking feasibility without saturation issues. This capability leads to timely and accurate ground motion forecasts and can support other methods, enhancing the overall effectiveness of EEW systems. Additionally, the ability to predict source parameters for real Chilean earthquakes implies that synthetic data, governed by our understanding of earthquake scaling, is consistent with the actual rupture processes.

58 GEOSCIENCES↗

A Power-Hardware-in-the-Loop (PHIL) Evaluation of Service Restoration With Networked Microgrids

This paper describes the power-hardware-in-the- loop (PHIL) evaluation of the feasibility of service restoration solutions determined by the PowerModelsONM.jl tool. This tool incorporates microgrids and the networking of microgrids into its determination of an optimal service restoration solution. The paper presents PHIL simulation results for a case study based on a real distribution feeder with multiple microgrids, showcas- ing the effectiveness of networked microgrids in aiding system restoration after an outage. The study leverages high-fidelity, real- time electromagnetic transient models to ensure accuracy in the simulation results. This work is the final output from the Resilient Operation of Networked Microgrids (RONM) project funded by the U.S. Department of Energy Office of Electricity Microgrid Program and led by Los Alamos National Laboratory. RONM focused on the application of PowerModelsONM.jl to enhance the resilience of distribution systems.

fault location isolation and service restoration (↗

Seismicity-constrained fault detection and characterization with a multitask machine learning model

Geological fault detection and characterization are crucial for understanding subsurface dynamics across scales. While methods for fault delineation based on either seismicity location analysis or seismic image reflector discontinuity are well-established, a systematic approach that integrates both data types remains absent. We develop a novel machine learning model that unifies seismic reflector images and seismicity location information to automatically identify geological faults and characterize their geometrical properties. The model encodes a seismic image and a seismicity location image separately, and fuses the encoded features with a spatial-channel attention fusion module to improve the learning of important features in both inputs. We design an automated strategy to generate high-quality synthetic training data and labels. To improve the realism of the seismicity location image, we include random seismicity noise and missing seismicity location associated with some of the faults. We validate the model’s efficacy and accuracy using synthetic data examples and two field data examples. Moreover, we show that fine-tuning the trained model with a small, domain-specific dataset enhances its fidelity for field data applications. The results demonstrate that integrating seismicity location and seismic images into a unified framework allows the end-to-end neural network to achieve higher fidelity and accuracy in delineating subsurface faults and their geometrical properties compared with image-only fault detection methods. Our approach offers an adaptive data-driven tool for geological fault characterization and seismic hazard mitigation, bridging the gap between seismicity location and image-based fault detection methods.

58 GEOSCIENCES↗

Factors controlling injection-induced rupture of intersecting faults during geological sequestration of CO 2

This study addresses coupled multiphase fluid flow and geomechanics effects on potential fault activation associated with subsurface CO 2 injection around intersecting faults. An enhanced fault-representation model is used to capture geomechanical responses of two intersecting faults with finite length during CO 2 injection. The faults are embedded in a strike-slip stress regime of a caprock-reservoir-basement system with the faults represented by zero-thickness interfaces with adjacent finite-thickness damage zones. A sensitivity analysis is conducted to study the effect of fault permeability, slip-weakening behavior, well location relative to the orientation of faults, and well placement (the number and location of injection wells). Five metrics (pressure, CO 2 plume, shear state on the fault, as well as shear displacement and stress path at selected fault monitoring points) are selected to assess CO 2 migration and reactivation of intersecting faults. The results show that induced ruptures are favored by low permeability faults due to high pressure buildup and by slip-weakening behavior resulting from fault strength reduction. The location of one injection well relative to fault orientation determines the magnitude of changes in effective normal stress and shear stress, affecting the location of induced ruptures. Well placement (two injection wells used in the paper) dominates pressure diffusion around the intersection and tips of faults. This redistributes changes in effective normal stress caused by each injection well, influencing the spatial distribution of ruptures along faults. A larger injection volume induces far-field ruptures that are controlled by stress transfer within the injection layer. The findings presented here can provide valuable insights into engineering operations for a long-term, safe, and reliable geologic CO 2 storage.

Fault permeability↗

A Systematic Framework for Tuning Open-Source Multifunctional IBR Models To Emulate OEM Black-Box Fault Dynamics

This paper presents a systematic framework to tune a generic IBR EMT model to match with an OEM provided balckbox inverter model based on the fault current responses. The key learnings and findings are summarized as follows: The tunable key parameters include inner control loops and current limiters to align the fault current magnitude, sequence content, and phase trajectories with the OEM models across diverse fault type and locations. The tuned model's fidelity is validated through comparative analysis with an OEM blackbox model, assessing both the fault current response and the responses of multiple relay elements. The results demonstrate the tuned generic model can trigger relay decision logic that is identical or near identical to that of the OEM model, thus generating very good match model for fault studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Relationships between fault characteristics and seismic responses in a large lab-scale tri-axial injection test conducted on a faulted Castlegate Sandstone

Here to investigate mechanisms causing microseismicity (M w < 2) at a CO 2 injection site, a large-scale triaxial block experiment was carried out on a faulted (saw-cut) cubic-meter of Castlegate Sandstone. The experiment consisted of injection tests at varying differential stresses, while monitoring and recording pore pressure and acoustic emissions (AEs). During the experiment, ~33,000 AEs and ~14 mm of horizontal displacement/slip, like a strike-slip fault movement, occurred. To understand the AE responses and ascertain fault characteristics near the located AEs, we modeled the topography of the fault surface, fault aperture, and fault-gouge thickness using pre- and post-experiment laser scans of the fault surface on each half of the block. Additionally, we characterized surface roughness parallel and perpendicular to slip. Models show crushing and flattening of the fault surfaces can be linked to the spatiotemporal distribution of AEs within 50 mm of the fault surface. Approximately 65% of AEs were in areas with small aperture (≤300 μm); thicker fault gouge was observed in adjacent areas with wider aperture and shows a two-fold reduction in grain size relative to unaltered Castlegate Sandstone. This work provides a conceptual understanding on fault surface evolution, which can be applied towards modeling of seismic slip.

58 GEOSCIENCES↗

DeFault: DEep‐Learning‐Based FAULT Delineation Using the IBDP Passive Seismic Data at the Decatur CO2 Storage Site

Abstract The carbon capture, utilization, and storage (CCUS) framework is an essential component in reducing greenhouse gas emissions, with its success hinging on the comprehensive knowledge of subsurface geology and geomechanics. Passive seismic event relocation and fault detection offer vital insights into subsurface structures and the ability to monitor fluid migration pathways. Accurate identification and localization of seismic events, however, face significant challenges, including the necessity for high‐quality seismic data and advanced computational methods. To address these challenges, we introduce a novel deep learning method, , specifically designed for passive seismic source relocation and fault delineating for passive seismic monitoring projects. By leveraging data domain‐adaptation, allows us to train a neural network with labeled synthetic data and apply it directly to field data. Using , the passive seismic sources are automatically clustered based on their recording time and spatial locations, and subsequently, faults and fractures are delineated accordingly. We demonstrate the efficacy of on a field case study involving injection related microseismic data from Decatur, Illinois area. Our approach accurately and efficiently relocated passive seismic events, identified faults and could aid in potential damage induced by seismicity. Our results highlight the potential of as a valuable tool for passive seismic monitoring, emphasizing its role in ensuring CCUS project safety. This research bolsters the understanding of subsurface characterization in CCUS, illustrating machine learning’s capacity to refine these methods. Ultimately, our work has significant implications for CCUS technology deployment, an essential strategy in combating climate change. Plain Language Summary In our quest to tackle climate change, we use a strategy known as carbon capture, utilization, and storage (CCUS) to keep greenhouse gases out of the atmosphere. This strategy relies heavily on our ability to understand what's happening deep under the earth's surface. To make sure we store super critical safely, we need to accurately map out the geological structure, especially faults, but this is tough without high‐quality data and complex computer programs. We've developed a new tool called “DeFault,” which uses advanced machine learning to improve how we find and map these underground features. “DeFault” is smart enough to learn from numerically simulated data and then apply what it’s learned to real‐world situations. It groups together seismic activity—tiny tremors and shifts in the earth—based on when and where they happen, which helps us spot where there might be cracks or faults. We tested “DeFault” in Illinois, where CO 2 is injected underground, and it successfully pinpointed where these tremors occurred and mapped out the faults, helping to prevent accidents accurately in the future. Our study shows that “DeFault” will be a powerful ally in making CCUS safer and more effective, especially for the Illinois Basin Decatur Project. Key Points Faults and fractures introduced by carbon storage can be monitored by passive seismicity DeFault algorithm enables an automatic process for accurate and efficient passive seismic event locating and clustering

58 GEOSCIENCES↗