Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Geomorphology, tectonics, and exploration

Explorationists interpret satellite images for tectonic features and patterns that may be clues to mineral and energy deposits. The tectonic features of interest range in scale from regional (sedimentary basins, fold belts) to local (faults, fractures) and are generally expressed as geomorphic features in remote sensing images. Explorationists typically employ classic concepts of geomorphology and landform analysis for their interpretations, which leads to the question - Are there new and evolving concepts in geomorphology that may be applicable to tectonic analyses of images?

Sabins, F. F., Jr.↗

An architecture for object-oriented intelligent control of power systems in space

A control system for autonomous distribution and control of electrical power during space missions is being developed. This system should free the astronauts from localizing faults and reconfiguring loads if problems with the power distribution and generation components occur. The control system uses an object-oriented simulation model of the power system and first principle knowledge to detect, identify, and isolate faults. Each power system component is represented as a separate object with knowledge of its normal behavior. The reasoning process takes place at three different levels of abstraction: the Physical Component Model (PCM) level, the Electrical Equivalent Model (EEM) level, and the Functional System Model (FSM) level, with the PCM the lowest level of abstraction and the FSM the highest. At the EEM level the power system components are reasoned about as their electrical equivalents, e.g, a resistive load is thought of as a resistor. However, at the PCM level detailed knowledge about the component's specific characteristics is taken into account. The FSM level models the system at the subsystem level, a level appropriate for reconfiguration and scheduling. The control system operates in two modes, a reactive and a proactive mode, simultaneously. In the reactive mode the control system receives measurement data from the power system and compares these values with values determined through simulation to detect the existence of a fault. The nature of the fault is then identified through a model-based reasoning process using mainly the EEM. Compound component models are constructed at the EEM level and used in the fault identification process. In the proactive mode the reasoning takes place at the PCM level. Individual components determine their future health status using a physical model and measured historical data. In case changes in the health status seem imminent the component warns the control system about its impending failure. The fault isolation process uses the FSM level for its reasoning base.

Holmquist, Sven G.↗

Paleomagnetic and structural evidence for localized tectonic rotation associated with fault drag in the northeastern Mojave Desert: Implications for the late Cenozoic tectonic evolution of the Eastern California shear zone

Paleomagnetic data, coupled with detailed geological analysis of the southeastern Goldstone Lake region, indicate that lower Miocene volcanic and epiclastic rocks of the Pink Canyon area have been folded, faulted and tectonically rotated approximately 28.4 + or - 9.0 deg clockwise about a vertical axis. The Coyote Canyon Fault is locally folded about a vertical axis approximately 25 deg in a clockwise sense in the Pink Canyon area. Timing relationships indicate that rotation is post-early Miocene; regional relationships imply that deformation is late Miocene to Holocene in age. These relationships imply that tectonic rotation is local rather than regional in extent as proposed by some tectonic models. The results of this study are generally consistent with the Dokka and Travis model and the subsequently revised Dokka model of strain partitioning in the northeastern Mojave Desert block.

Macconnell, D. F.↗

NNREPAIR: Constraint-based Repair of Neural Network Classifiers

We present NNREPAIR, a constraint-based technique for repairing neural network classifiers by i) fixing the logic of the network at an intermediate layer, and ii) fixing the decision conditions of the network at the last layer. NNREPAIR first uses fault localization to find potentially faulty network parameters (specifically weights) and then performs repair using constraint solving to apply small modifications to remedy the defects. We present novel strategies to enable precise yet efficient repair such as inferring correctness specifications to act as oracles for intermediate layer repair, and generation of experts wrt each class. We demonstrate the technique in the context of three different scenarios: (1) Improving the over all accuracy of a model, (2) Fixing security vulnerabilities caused by poisoning of training data and (3) Improving the robustness of the network against adversarial attacks. Our evaluation on MNIST and CIFAR-10 models shows that NNREPAIR can improve the accuracy by 45.56% on poisoned data and 11.11% on adversarial data. NNREPAIR also provides improvement, albeit modest, in the overall accuracy of models, without requiring new data or re-training.

Repair↗

Defect Length and Profile Influence on Frequency Domain Reflectometry

Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. Although system tests verify cable function under normal loads, demonstration of some cable’s ability to perform under exceptional loads associated with design-basis events is essential to assuring plant integrity. The cable’s ability to perform safely over the initial 40 year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found in an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program that includes condition monitoring to justify cable performance under normal operation as well as accident conditions. A variety of tests are available to assess various aspects of electrical and mechanical cable performance, but none are suitable for all cable configurations nor does any single test confirm all features of interest. One particularly promising test that is beginning to be used more and more by utilities is frequency domain reflectometry (FDR). FDR is a nondestructive electrical inspection technique used to detect and localize faults in power and communication system conductors along the length of a cable from a single connection point. FDR detects discontinuities in the electrical impedance that arise due to cable splices or similar changes along the path of the conductor pair. In addition, FDR has the potential to provide sensitivity to insulation degradation by detecting small changes in impedance between the cable conductors being examined. The technique is also sensitive to cable bends, the particular lay of the cable in tray, proximity to other cable, and other factors that bear consideration when interpreting the test results. This paper examines various influences on the FDR approach particularly using FEM modeling methods and focusing on defect length and defect profile.

Cable Inspection, Frequency Domain Reflectometry, ↗

Communications protocols for a fault tolerant, integrated local area network for Space Station applications

The evolutionary growth of the Space Station and the diverse activities onboard are expected to require a hierarchy of integrated,local area networks capable of supporting data, voice and video communications. In addition, fault tolerant network operation is necessary to protect communications between critical systems attached to the net and to relieve the valuable human resources onboard Space Station of day-to-day data system repair tasks. An experimental, local area network is being developed which will serve as a testbed for investigating candidate algorithms and technologies for a fault tolerant, integrated network. The establishment of a set of rules or protocols which govern communications on the net is essential to obtain orderly and reliable operation. A hierarchy of protocols for the experimental network is presented and procedures for data and control communications are described.

Meredith, B. D.↗

Local lattice distortion mediated formation of stacking faults in Mg alloys

Long periodic stacking ordered phases (LPSOs), consisting of various configurations of stacking faults, play an important role in developing ultrastrong Mg alloys with moderate ductility. However, their formation mechanisms are far from clear as no apparent defects are introduced during their formation as it is commonly believed that stacking faults are induced by defects. Here, we present the atomic and electronic basis for lattice-distortion-mediated formation of stacking faults, i.e., localized face-centredcubic (FCC) structures, within a Mg-Zn-Y alloy with a hexagonal close-packed (HCP) structure. The atomic motion trajectories from ab-initio molecular dynamic simulations show that the Mg atoms occupying the nearest neighbour positions of Zn and Y solute atoms undergo a local HCP-to-FCC transition. It is revealed that a local lattice distortion caused by the solute atoms enables the Mg atoms to move and rearrange into a local FCC configuration, which is validated by high resolution scanning transmission microscopy and in-situ synchrotron X-ray diffraction. Our simulations provide profound insight into the formation mechanism of stacking faults in HCP Mg and their physical nature of phase transformations. This is not only critically important because conventional defects, such as dislocations and vacancies, are important to deformation for Mg and its alloys, but also because they serve as a potential new approach to the design of advanced Mg alloys when defects could be used to facilitate

36 MATERIALS SCIENCE↗

Fault-Tolerant Local-Area Network

Local-area network (LAN) for computers prevents single-point failure from interrupting communication between nodes of network. Includes two complete cables, LAN 1 and LAN 2. Microprocessor-based slave switches link cables to network-node devices as work stations, print servers, and file servers. Slave switches respond to commands from master switch, connecting nodes to two cable networks or disconnecting them so they are completely isolated. System monitor and control computer (SMC) acts as gateway, allowing nodes on either cable to communicate with each other and ensuring that LAN 1 and LAN 2 are fully used when functioning properly. Network monitors and controls itself, automatically routes traffic for efficient use of resources, and isolates and corrects its own faults, with potential dramatic reduction in time out of service.

Morales, Sergio↗

Spread Spectrum Time Domain Reflectivity for String Monitoring in PV Power Plants (Final Technical Report)

This final report describes the methods and results of applying Spread Spectrum Time Domain Reflectivity (SSTDR) for String Monitoring in PV Power Plants for DE-EE0008169. The project created a new system for both detecting and locating electrical faults in photovoltaic systems. In this work, we address photovoltaic electric faults that are both common and costly. Based on interviews with photovoltaic power plant owners, operators, and maintainers, three types of faults are common and of significant interest: disconnects, ground faults, and arc faults. Disconnects can originate from many sources. They are often due to everyday events, such as lawnmowing (accidentally running over a cable), animals eating through the cables, or degradation that occurs over time due to corrosion or general degradation. Ground faults occur when the cables (for example, due to frayed insolation) connect to the ground, relaying current into the ground. These faults are particularly problematic since the ground faults are often intermittent. That is, ground faults commonly appear during rain storms due to a change in soil conductivity and then disappear when the rain ends. This makes the ground fault difficult to find because while current systems can detect the overall change in voltage and current associated with a ground fault, technicians are necessary to locate the fault. As a result, ground faults may disappear before the technician arrives at the power plant. Hence, locating and fixing ground faults often require multiple trips. We also study arc faults, which can result when nearby conductors create an arc of electrical current through the air. While less common, arc faults can be extremely dangerous. The energetic electrical arc can cause fires and destroy equipment, costing significant damage. Overall all three types of faults cost owners and operators money, either from the destruction of equipment or from technician time. Furthermore, while devices exist for detecting ground faults (ground fault circuit interrupters) and arc faults (arc fault circuit interrupter), these systems only search patterns of electrical current that correspond to each fault. This information cannot be used to locate the fault. In addition, these protection systems experience nuisance trips due to nearby electromagnetic interference, such as from a lawn mower or other motors that produce significant amounts of electromagnetic radiation. Hence, the overall goal of this project is to create an SSTDR tool that provides photovoltaic power plants with more reliable fault detection in addition to the localization of faults. SSTDR works by transmitting electrical signals into the photovoltaic string. Those signals reflect from impedance discontinuities (i.e., disconnects, ground faults, and arc faults). These faults are then detected by measuring the presence of a reflection at the SSTDR and can be located by identifying the location of that reflection in time. In addition, unlike current protection systems, these systems do not experience nuisance trips since their low amplitude, high frequency, and coded signal can by analyzed without interference from the regular operational voltage on the photovoltaic string.

14 SOLAR ENERGY↗

Cathodoluminescence of stacking fault bound excitons for local probing of the exciton diffusion length in single GaN nanowires

We perform correlated studies of individual GaN nanowires in scanning electron microscopy combined to low temperature cathodoluminescence, microphotoluminescence, and scanning transmission electron microscopy. We show that some nanowires exhibit well localized regions emitting light at the energy of a stacking fault bound exciton (3.42 eV) and are able to observe the presence of a single stacking fault in these regions. Precise measurements of the cathodoluminescence signal in the vicinity of the stacking fault give access to the exciton diffusion length near this location.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Tunable stacking fault energies by tailoring local chemical order in CrCoNi medium-entropy alloys

High-entropy alloys (HEAs) are an intriguing new class of metallic materials due to their unique mechanical behavior. Achieving a detailed understanding of structure–property relationships in these materials has been challenged by the compositional disorder that underlies their unique mechanical behavior. Accordingly, in this work, we employ first-principles calculations to investigate the nature of local chemical order and establish its relationship to the intrinsic and extrinsic stacking fault energy (SFE) in CrCoNi medium-entropy solid-solution alloys, whose combination of strength, ductility, and toughness properties approaches the best on record. We find that the average intrinsic and extrinsic SFE are both highly tunable, with values ranging from –43 to 30 mJ•m –2 and from –28 to 66 mJ•m –2 , respectively, as the degree of local chemical order increases. The state of local ordering also strongly correlates with the energy difference between the face-centered cubic ( fcc ) and hexagonal close-packed ( hcp ) phases, which affects the occurrence of transformation-induced plasticity. Here, this theoretical study demonstrates that chemical short-range order is thermodynamically favored in HEAs and can be tuned to affect the mechanical behavior of these alloys. It thus addresses the pressing need to establish robust processing–structure–property relationships to guide the science-based design of new HEAs with targeted mechanical behavior.

36 MATERIALS SCIENCE↗

Local precision nets for monitoring movements of faults and large engineering structures

Along Bocono Fault were installed local high precision geodetic nets to observe the possible horizontal crustal deformations and movements. In the fault area there are few big structures which are also included in the mentioned investigation. In the near future, measurements shall be extended to other sites of Bocono Fault and also to the El Pilar Fault. In the same way and by similar methods high precision geodetic nets are applied in Venezuela to observe the behavior of big structures, as bridges and large dams and of earth surface deformations due to industrial activities.

Henneberg, H. G.↗

Ion-absorption band analysis for the discrimination of iron-rich zones

The author has identified the following significant results. A technique which combines digital computer processing and color composition was devised for detecting hydrothermally altered areas and for discriminating among many rock types in an area in south-central Nevada. Subtle spectral reflectance differences among the rock types are enhanced by ratioing and contrast-stretching MSS radiance values for form ratio images which subsequently are displayed in color-ratio composites. Landform analysis of Nevada shows that linear features compiled without respect to length results in approximately 25 percent coincidence with mapped faults. About 80 percent of the major lineaments coincides with mapped faults, and substantial extension of locally mapped faults is commonly indicated. Seven major lineament systems appear to be old zones of crustal weakness which have provided preferred conduits for rising magma through periodic reactivation.

Rowan, L. C.↗

Adaptive Threshold-Based Zonal Isolation of Faults in a Multiterminal DC Using Local Measurements

Fast and accurate methods of fault detection and isolation are a pre-emptive measure in multiterminal dc (MTdc) systems. Zonal isolation of faults is necessary to prevent any misopertation of the dc breakers that can lead to a shutdown of the network. Existing techniques require fast-communication or data synchronization methods have their own disadvantages. This article proposes a method for efficient fault zone isolation without the need of a communication link that prevents any misoperation of the dc breakers in a radial MTdc. This method provides individual local measurement-based control to the hybrid dc circuit breakers (dcCB). Faults created outside the zone of protection for a breaker create a change in the rate of change of current or voltage leading to misoperation. To avoid detection using a fixed threshold, an adaptive threshold based approach is suggested that updates the threshold based on the present operating status. Sensitivity analysis by varying the current limiting inductance and fault location is performed. In conclusion, a three terminal radial model of an MTdc is used for zonal isolation using power system computer aided design/electromagnetic transients including dc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Local-environment dependence of stacking fault energies in concentrated solid-solution alloys

Concentrated solid-solution alloys (CSAs) based on 3d transition metals have demonstrated extraordinary mechanical properties and radiation resistance associated with their low stacking fault energies (SFEs). Owing to the intrinsic disorder, SFEs in CSAs exhibit distributions depending on local atomic configurations. In this work, the distribution of SFEs in equiatomic CSAs of NiCo, NiFe, and NiCoCr are investigated based on empirical potential and first-principles calculations. We show that the calculated distribution of SFEs in chemically disordered CSAs depends on the stacking fault area using empirical potential calculations. Based on electronic structure calculations, we find that local variations of SFEs in CSAs correlate with the charge density redistribution in the stacking fault region. We further propose a bond breaking and forming model to understand and predict the SFEs in CSAs based on the local structure alone. It is shown that the perturbation induced by a stacking fault is localized in the first-nearest planes for NiCo, but extends up to the third nearest planes for NiFe and NiCoCr because of partially filled d electrons in Fe and Cr.

36 MATERIALS SCIENCE↗