Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

In-situ experiment reveals CO2 enriched fluid migration in faulted caprock

Abstract The sealing characteristics of the geological formation located above a CO 2 storage reservoir, the so-called caprock, are essential to ensure efficient geological carbon storage. If CO 2 were to leak through the caprock, temporal changes in fluid geochemistry can reveal fundamental information on migration mechanisms and induced fluid–rock interactions. Here, we present the results from a unique in-situ injection experiment, where CO 2 -enriched fluid was continuously injected in a faulted caprock analogue. Our results show that the CO 2 migration follows complex pathways within the fault structure. The joint analysis of noble gases, ion concentrations and carbon isotopes allow us to quantify mixing between injected CO 2 -enriched fluid and resident formation water and to describe the temporal evolution of water–rock interaction processes. The results presented here are a crucial complement to the geophysical monitoring at the fracture scale highlighting a unique migration of CO 2 in fault zones.

Science & Technology - Other Topics↗

Analysis of Line Distance Elements for Various Ibr Controllers and System Conditions

The large-scale penetration of inverter-based resources in power systems has challenged protection engineers because of the different fault behaviors these sources provide compared to conventional generation systems. The main challenges include a low level of fault current magnitude, unpredictable angles of sequence currents, and lack of inertia that can lead to maloperation of conventional phasor-based protection elements. This paper presents a sensitivity analysis of transmission line distance protection elements during phase-to-ground and phase-to-phase faults for different inverter controllers and power system conditions. It also summarizes which line protection elements remain secure near IBR terminations and identifies the ones affected by the inverter-based response. The paper concludes by highlighting that regulating negative-sequence current injection during the fault aids correct protection decisions, but does not address the entire challenge. Finally, alternative protection elements to those affected by the inverter fault response are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Geomechanical in situ testing of fault reactivation in argillite repositories

Abstract. Pressurization of natural faults as a result of repository-induced effects can lead to their reactivation and permeability generation in case such features are present near disposal tunnels. Potential driving forces for such pressurization are the temperature increase caused by heat-producing high-level radioactive waste and the generation of hydrogen and other gases due to corrosion of engineered materials. We are primarily concerned about pressurization and fault activation in host rocks and faults that have very low natural permeability for pore pressure increases to dissipate, such as the argillite rocks currently investigated in Switzerland, France and other countries. This presentation discusses a series of in situ experiments of fault activation by fluid injection conducted in the argillite rock (Opalinus clay) at the Mont Terri underground research laboratory in Switzerland. A multi-model monitoring test bed was installed at Mont Terri that includes distributed fiber optics for strain, temperature, and acoustics; local fault pore pressure and three-dimensional displacement sensors; active seismic imaging; and passive seismic monitoring. The fault experiments (and their subsequent analysis via hydromechanical modeling) provide a new fundamental understanding of the coupling between pore pressure, fault deformation and permeability generation as a function of time and allow exploring how seismic and aseismic events may impact the integrity of faulted argillite host rock. Our experimental observations demonstrate that significant flow (and transport) can occur along the initially impermeable argillite fault when rupture is activated. However, the fault permeability decreases to almost its pre-activation value when fluid injection ceases and fluid pressure drops. Dilatant slip on the fault plane alone does not explain the observed increase in fault permeability; pressure-induced fault opening also plays a role, favored by the softness of the shale along with the fact that the structure of the fault zone prevents fluids from diffusing into the adjacent damage zone. Rupture initiation and permeability generation is initially aseismic, associated only with an increase in noise level and emerging tremors. Micro-earthquakes are initiated later in the experiments and typically occur away from the fluid-pressurized area. Hydromechanical models show that stress transferred from the initial aseismic deformation can build up to stress criticality and later induce seismic rupture. After presenting the experimental results, we will close the presentation with an outlook to future experimental campaigns using the fault test bed at Mont Terri. We are currently planning a controlled thermal stimulation of the fault, where instead of fluid injection as a trigger mechanism we will heat up the nearby rock volume and measure potential effects on fault stability. Lessons learned from our past and future experiments will help inform the safety assessment of geologic disposal in argillite host rock.

Birkholzer, Jens T.↗

Boosting Barlow Twins Reduced Order Modeling for Machine Learning‐Based Surrogate Models in Multiphase Flow Problems

Abstract We present an innovative approach called boosting Barlow Twins reduced order modeling (BBT‐ROM) to enhance the reliability of machine learning surrogate models for multiphase flow problems. BBT‐ROM builds upon Barlow Twins reduced order modeling that leverages self‐supervised learning to effectively handle linear and nonlinear manifolds by constructing well‐structured latent spaces of input parameters and output quantities. To address the challenge of high contrast data in multiphase flow problems due to injection wells and faults, we employ a boosting algorithm within BBT‐ROM. This algorithm sequentially trains a set of weak models (i.e., inaccurate models), improving prediction accuracy through ensemble learning. To evaluate the performance of BBT‐ROM, we conduct three three‐dimensional multiphase flow problems, including waterflooding and geologic carbon storage (GCS), with varying numbers of input parameter cases and model domain features. The results demonstrate that BBT‐ROM excels at predicting non‐wetting phase saturation (e.g., oil or saturation) and fluid pressure, with average relative errors ranging from 0.5% to 3%. Importantly, BBT‐ROM showcases robustness when faced with limited input parameter space during GCS testing.

58 GEOSCIENCES↗

Three-dimensional seismic characterization and imaging of the Soda Lake geothermal field

Accurate characterization of subsurface geophysical properties and detection of the fault system are essential for geothermal energy exploration and production. The Soda Lake geothermal field is in western Nevada with a complex fault system. Previous seismic characterization only produced a low-resolution, smooth velocity model along with a simple, conceptual fault model. Using optimized correlation-based full-waveform inversion, wavefield-separation-based reverse-time migration, and automatic fault detection techniques, we present 3D seismic characterization for the Soda Lake geothermal field using 3D surface seismic data acquired with Vibroseis sources. Here, we obtain 3D high-resolution velocity, density, and acoustic impedance models, 3D seismic images with different grid spacings, and a high-resolution fault system. Consistency check between the constructed faults and currently active injection and production geothermal wells verifies that our seismic inversion and imaging results and detected faults are reliable. These results can provide valuable information for optimizing well placement and geothermal energy production at the Soda Lake geothermal field.

15 GEOTHERMAL ENERGY↗

Constraining maximum event magnitude during injection-triggered seismicity

Abstract Understanding mechanisms controlling fluid injection-triggered seismicity is key in defining strategies to ameliorate it. Recent triggered events (e.g. Pohang, Mw 5.5) have exceeded predictions of average energy release by a factor of >1000x, necessitating robust methodologies to both define critical antecedent conditions and to thereby constrain anticipated event size. We define maximum event magnitudes resulting from triggering as a function of pre-existing critical stresses and fluid injection volume. Fluid injection experiments on prestressed laboratory faults confirm these estimates of triggered moment magnitudes for varied boundary conditions and injection rates. In addition, observed ratios of shear slip to dilation rates on individual faults signal triggering and may serve as a measurable proxy for impending rupture. This new framework provides a robust method of constraining maximum event size for preloaded faults and unifies prior laboratory and field observations that span sixteen decades in injection volume and four decades in length scale.

58 GEOSCIENCES↗

Forecasting fluid-injection induced seismicity to choose the best injection strategy for safety and efficiency

Induced seismicity poses a challenge to the development of Enhanced Geothermal Systems (EGS). Improving monitoring and forecasting techniques is essential to mitigate induced seismicity and thereby fostering a positive perception of EGS projects among local authorities and population. Induced seismicity is the result of complex and coupled thermo-hydro-mechanical-chemical mechanisms. Injection flux and pressure are crucial controlling parameters for both hydraulic stimulation and circulation protocols. We develop a methodology combining a hydro-mechanical model with a seismicity rate model to estimate the magnitude and frequency of mainshocks and aftershocks induced by fluid injection. We apply the methodology to the case of the Basel EGS (2006, Switzerland) to compare the effects of progressive, cyclic and constant injections on the mechanical response of discrete faults. Results from the coupled hydro-mechanical models show that the pore pressure diffusion and consequent enhancement of fault permeability are limited to the vicinity of the injection well during cyclic injection. Additionally, constant injection induces seismicity from the start of the injection but enhances the permeability of most of the faults within a shorter duration, inducing less post-injection seismicity. The methodology can be adapted to any numerical model and allows new projects to be developed by anticipating the safest injection protocol. This article is part of the theme issue ‘Induced seismicity in coupled subsurface systems’.

58 GEOSCIENCES↗

Cubic-meter scale laboratory fault re-activation experiments to improve the understanding of induced seismicity risks

Abstract To understand fluid induced seismicity, we have designed a large-scale laboratory experiment consisting of a one-cubic-meter sandstone with an artificial fault cut and fluid-injection boreholes. The sandstone block is assembled in a true triaxial loading frame and equipped with 38 piezoelectric sensors to locate and characterise acoustic emission events. The differential stress on the artificial fault is increased in stages to bring it towards a critically stressed state. After each stage of differential stress increase, fluids are injected at low pressures through boreholes to test the potential of fault re-activation. In addition, a high-pressure injection was conducted that created a hydraulic fracture from the injection borehole towards the artificial fault. The newly generated fluid pathway resulted in an activation of the complete block through a stick–slip movement. We compare acoustic emission measurements from the laboratory experiment with seismicity observations from the field-scale CO 2 injection at Decatur, Illinois, U.S., and conclude that the existence of fluid pathways plays a decisive role for the potential of induced seismicity.

47 OTHER INSTRUMENTATION↗

Transient Stability Study of IEEE 2800-2022 Standard Negative-Sequence-Current Compliant GFM IBRs

The primary function of grid-forming (GFM) inverter-based resources (IBRs) is to maintain voltage and fre- quency/phase angle stability; however, during unbalanced grid faults, IEEE Std. 2800-2022 requires IBRs to inject both positive- and negative-sequence reactive current. Enforcing compliance with this standard could compromise the stability of GFM IBRs under such fault conditions. This paper presents a preliminary transient stability study focused on the power angle stability of GFM IBRs operating in compliance with IEEE Std. 2800 during unbalanced faults. The goal is to assess potential stability issues associated with the standard's current injection requirements under fault ride-through conditions. The results show that injecting positive-sequence current with d-axis priority during unbalanced faults better preserves the power angle stability than the q-axis priority while still enabling negative-sequence current injection. These findings suggest that, to ensure stability, GFM IBRs might need to partially comply with IEEE Std. 2800 by prioritizing positive-sequence current injection along the d-axis.

14 SOLAR ENERGY↗

Phase II Field Demonstration at Lansing Smith Generating Plant, Southport, Florida (Final Report)

The Final Technical Report: Field Test Design and Pressure Management Strategies for Phase II Field Demonstration of Optimal Pressure Control, Plume Management, and Produced Water Strategies presents the culmination of multi-year efforts under the U.S. Department of Energy’s Brine Extraction and Storage Test (BEST) program, led by EPRI in partnership with Gulf Power at the Plant Smith site near Panama City, Florida. The project was designed to evaluate and demonstrate the technical feasibility of managing subsurface pressures and fluid movement associated with large-scale CO₂ injection, using low-salinity water as a proxy fluid. Through a combination of field injection testing, reservoir modeling, and optimization studies, the research team developed and refined active and passive brine extraction strategies aimed at controlling injection-induced pressure buildup, mitigating risks of fault activation, and managing plume migration. The field demonstration incorporated a new injection well (TIW-2), a new monitoring/extraction well (TEMW-A), and an existing well (TIW-1) repurposed for passive pressure relief. Complementary geophysical monitoring was designed to track plume development and evaluate the effectiveness of pressure management strategies. The report details the integrated workflow encompassing wellfield development, regulatory permitting, model calibration, and survey design. It includes a comprehensive electromagnetic (EM) modeling and inversion study used to develop a cost-effective, time-lapse geophysical monitoring plan capable of imaging the evolving low-salinity plume within the highly saline Lower Tuscaloosa formation. Reservoir simulation results guided the design of the 17-month injection program and the timing of active extraction to maintain formation pressures below a hypothetical fault reactivation threshold. Supporting analyses evaluated potential injectivity risks related to clay fines migration and geochemical incompatibility, identifying practical mitigation measures such as salinity and pH control. The final design recommends a series of crosswell EM surveys—conducted before, during, and after injection—as the most effective and economical approach for plume imaging, supplemented by continuous downhole pressure and flow monitoring. Collectively, the study provides a field-ready framework for cost-effective pressure management and monitoring in support of future CO₂ storage projects.

01 COAL, LIGNITE, AND PEAT↗

Unsupervised Clustering of Microseismic Events and Focal Mechanism Analysis at the CO 2 Injection Site in Decatur, Illinois

Characterization of induced microseismicity at a carbon dioxide (CO 2 ) storage site is critical for preserving reservoir integrity and mitigating seismic hazards. We apply a multilevel machine learning (ML) approach that combines the nonnegative matrix factorization and hidden Markov model to extract spectral representations of microseismic events and cluster them to identify seismic patterns at the Illinois Basin-Decatur Project. Unlike traditional waveform correlation methods, this approach leverages spectral characteristics of first arrivals to improve event classification and detect previously undetected planes of weakness. By integrating ML-based clustering with focal mechanism analysis, we resolve small-scale fault structures that are below the detection limits of conventional seismic imaging. Our findings reveal temporal bursts of microseismicity associated with brittle failure, providing insights into the spatio-temporal evolution of fault reactivation during CO 2 injection. This approach enhances seismic monitoring capabilities at CO 2 injection sites by improving fault characterization beyond the resolution of standard geophysical surveys.

Willis, Rachel Marie [Sandia National Laboratories↗

Transient evolution of permeability and friction in a slowly slipping fault activated by fluid pressurization

The mechanisms of permeability and friction evolution in a natural fault are investigated in situ. During three fluid injection experiments at different places in a fault zone, we measured simultaneously the fluid pressure, fault displacements and seismic activity. Changes in fault permeability and friction are then estimated concurrently. Results show that fault permeability increases up to 1.58 order of magnitude as a result of reducing effective normal stress and cumulative dilatant slip, and 19-to-60.8% of the enhancement occurs without seismic emissions. When modeling the fault displacement, we found that a rate-and-state friction and a permeability dependent on both slip and slip velocity together reasonably fit the fault-parallel and fault-normal displacements. This leads to the conclusion that the transient evolution of fault permeability and friction caused by a pressure perturbation exerts a potentially dominant control on fault stability during fluid flow.

58 GEOSCIENCES↗

Mechanisms for Microseismicity Occurrence Due to CO 2 Injection at Decatur, Illinois: A Coupled Multiphase Flow and Geomechanics Perspective

Here, we numerically investigate the mechanisms that resulted in induced seismicity occurrence associated with CO 2 injection at the Illinois Basin–Decatur Project (IBDP). We build a geologically consistent model that honors key stratigraphic horizons and 3D fault surfaces interpreted using surface seismic data and microseismicity locations. We populate our model with reservoir and geomechanical properties estimated using well-log and core data. We then performed coupled multiphase flow and geomechanics modeling to investigate the impact of CO 2 injection on fault stability using the Coulomb failure criteria. We calibrate our flow model using measured reservoir pressure during the CO 2 injection phase. Our model results show that pore-pressure diffusion along faults connecting the injection interval to the basement is essential to explain the destabilization of the regions where microseismicity occurred, and that poroelastic stresses alone would result in stabilization of those regions. Slip tendency analysis indicates that, due to their orientations with respect to the maximum horizontal stress direction, the faults where the microseismicity occurred were very close to failure prior to injection. These model results highlight the importance of accurate subsurface fault characterization for CO 2 sequestration operations.

58 GEOSCIENCES↗

Hydromechanical Modeling of Fault Rupture in Geologic CO 2 Sequestration: A Comparison of Two Failure Criteria

Abstract The large‐scale implementation of geological carbon sequestration has raised concerns about potential fault activation and induced seismicity, which could compromise storage integrity and pose seismic risks. We theoretically compared two failure criteria, Mohr‐Coulomb (MC) and Modified Cam‐Clay criteria (MCC), to assess fault rupture during CO 2 storage. Both criteria characterize fault behavior in a specific stress regime but differ in reducing the complexity of fault rupture to a few key mechanisms. Using a coupled hydromechanical model, we demonstrate that the choice of a failure criterion and the physics of fault weakening associated with these criteria strongly condition fault response to a given fluid injection. MC mainly relates rupture to friction, while MCC relates rupture to fault poro‐plasticity. Our findings highlight that the selection of a failure criterion, being inherently subjective, can significantly alter the predicted fault behavior during CO 2 storage, thereby impacting the reliability of geomechanical risk assessments.

Cao, M. [Energy Geosciences Division Lawrence Berk↗

Coupled Hydromechanical Modeling of Induced Seismicity From CO 2 Injection in the Illinois Basin

Injection of CO 2 for geologic carbon sequestration into deep sedimentary formations involves fluid pressure increases that engage hydromechanical processes that can cause seismicity by activation of existing faults. In this work, we use a coupled multiphase fluid flow and geomechanical simulator to model spatiotemporal fluid pressure and stress changes in order to study the poroelastic effect of CO 2 injection on faults in crystalline basement rock below the injection zone. The seismicity rate along features interpreted to be basement faults is modeled using Dieterich's rate-and-state earthquake nucleation model. The methodology is applied to microseismicity detected during CO 2 injection into the Mount Simon formation during the Illinois Basin—Decatur Project. The modeling accurately captures an observed reduction in seismicity rate when the injection in the second well was into a slightly shallower zone above the base of the Mount Simon formation. Moreover, the modeling shows that it is important to consider poroelastic stress changes, in addition to fluid pressure changes for accurately modeling of the observed seismicity rate.

58 GEOSCIENCES↗

Permeability-controlled migration of induced seismicity to deeper depths near Venus in North Texas

Abstract Migration of seismic events to deeper depths along basement faults over time has been observed in the wastewater injection sites, which can be correlated spatially and temporally to the propagation or retardation of pressure fronts and corresponding poroelastic response to given operation history. The seismicity rate model has been suggested as a physical indicator for the potential of earthquake nucleation along faults by quantifying poroelastic response to multiple well operations. Our field-scale model indicates that migrating patterns of 2015–2018 seismicity observed near Venus, TX are likely attributed to spatio-temporal evolution of Coulomb stressing rate constrained by the fault permeability. Even after reducing injection volumes since 2015, pore pressure continues to diffuse and steady transfer of elastic energy to the deep fault zone increases stressing rate consistently that can induce more frequent earthquakes at large distance scales. Sensitivity tests with variation in fault permeability show that (1) slow diffusion along a low-permeability fault limits earthquake nucleation near the injection interval or (2) rapid relaxation of pressure buildup within a high-permeability fault, caused by reducing injection volumes, may mitigate the seismic potential promptly.

58 GEOSCIENCES↗