Calculation of Fault Current Contribution of Type I Wind Turbine-Generators
No abstract prepared.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract prepared.
This poster describes how the power system switchgear and power system protection for WPPs should be carefully designed to be compatible with the operation of conventional synchronous generators connected to the same grid.
The original version of this article contains the following mistakes: On the second page 1st paragraph under heading “The Role of the Substrate Diffusivity” second and third sentences, 90 K, 300 cm{sup 2}/s and 5 mm, should be replaced with 65 K, 100 cm{sup 2}/s and 3 mm.
Not Available
Abstract not provided.
Abstract not provided
Abstract not provided.
Not provided.
Not provided.
This an abstract for the fall Electrochemical Society Conference (ECS)
Explore the source record for details and available documents.
Documentation is presented of the December 1986 version of the ADA code for the fault detection, isolation, and reconfiguration (FDIR) functions of the Advanced Information processing System (AIPS) Fault-Tolerant Processor (FTP). Because the FTP is still under development and the software is constantly undergoing changes, this should not be considered final documentation of the FDIR software of the FTP.
The key product of this three-day workshop is a NASA White Paper that documents lessons learned from previous missions, recommended best practices, and future opportunities for investments in the fault management domain. This paper summarizes the findings and recommendations that are captured in the White Paper.
With increasing demand of the power load and the development of the new energy resources, voltage-sourced converter-based high-voltage direct current (VSC-HVDC) transmission system has been widely utilized. However, its development is seriously limited due to short circuit. To address this, high-temperature superconducting direct current fault current limiter (DC-SFCL) is designed. In this paper, a novel topology of DC-SFCL is firstly presented along with its principle and mathematical model. Secondly, the thermoelectric model of its superconducting current-limiting unit (SCLU) is established. In addition, simulation of VSC-HVDC system containing this novel DC-SFCL topology is analyzed using Simulink software. Finally, experimental measurements are designed and conducted to verify the correctness of the theoretical model.
For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.