Machine Learning for Single-Axis Tracker Fault Detection and Classification
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Synchrophasor technology has been used for monitoring, control, and protection of bulk power system for over 10 years. Deployment of phasor measurement units (PMUs) in the USA power system has surpassed 3000 units installed in the transmission substations as stand-alone intelligent electronic devices (IEDs) or as a software add-on to other devices such as digital protective relays (DPRs) or digital fault recorders (DFRs). By now, thousands of terabytes of PMU data may have been captured and stored by various transmission system operators (TSOs) and independent system operators (ISOs). This creates an opportunity to deploy advanced machine learning (ML) techniques to detect and classify faults recorded by PMUs automatically to be used by the system operators for rapid, critical decision-making when manual analysis of the past or unfolding events is not feasible. In this paper we offer a brief background on how the automated fault analysis may be done using DPR and/or DFR data, and compare some of the legacy approaches to the new ML approaches in the context of the system-wide PMU recordings. We then offer insights from developing practical ML solutions that have been applied on field recordings captured by close to 450 PMUs from all three US interconnections (Western, Eastern and ERCOT) over two years (2016-2017). We identify and illustrate ML challenges we addressed: inaccurate data, data with scarce and temporally imprecise fault labels, data recorded by PMUs sparsely located at substations resulting in the fault records taken afar from the ends of the faulted lines, data containing only positive sequence values, and data taken at different voltage levels. We then illustrate the ML model results for fault analysis under different application scenarios. The novelty of this study is not only in the design, implementation, and performance analysis of the ML algorithms, but also in the use of advanced fault modelling and simulation approaches to improve the training results when developing supervised ML models for fault detection and classification. Extensive simulations of faults were conducted on a 14-bus power system to create a training dataset with over 1400 accurately labelled faults. This dataset was applied to enhance the accuracy of fault detection and classification of machine learning-based models trained with small number of labelled faults in large datasets recorded in the grid interconnections ranging from 5,000 to 70,000 buses.
Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by improper relay settings or malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that they act and perform as expected. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.
Abstract Fault detection and classification in photovoltaic (PV) systems through real‐time monitoring is a fundamental task that ensures quality of operation and significantly improves the performance and reliability of operating systems. Different statistical and comparative approaches have already been proposed in the literature for fault detection; however, accurate classification of fault and loss incidents based on PV performance time series remains a key challenge. Failure diagnosis and trend‐based performance loss routines were developed in this work for detecting PV underperformance and accurately identifying the different fault types and loss mechanisms. The proposed routines focus mainly on the differentiation of failures (e.g., inverter faults) from irreversible (e.g., degradation) and reversible (e.g., snow and soiling) performance loss factors based on statistical analysis. The proposed routines were benchmarked using historical inverter data obtained from a 1.8 MWp PV power plant. The results demonstrated the effectiveness of the routines for detecting failures and loss mechanisms and the capability of the pipeline for distinguishing underperformance issues using anomaly detection and change‐point (CP) models. Finally, a CP model was used to extract significant changes in time series data, to detect soiling and cleaning events and to estimate both the performance loss and degradation rates of fielded PV systems.
The dataset was created to train machine learning models for the task of identifying the (1) cavity and (2) fault type from C100-type cryomodules at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), thereby replacing the time-consuming efforts of a subject matter expert. Superconducting radio-frequency (SRF) cavity trips represent a significant source of accelerator downtime. Real-time – rather than post-mortem – identification of the offending cavity and classification of the fault type would give control room operators valuable feedback for corrective action planning. The anticipated benefit is increased beam-on-target time for users and provides performance metrics that can be used to improve future cavity designs. A series of 17 RF signals are recorded for each of the 8 cavities in a C100 cryomodule every time a cavity trips. These time-series signals are written to file using a specially designed data acquisition system. The dataset represents fault events recorded during Continuous Electron Beam Accelerator Facility (CEBAF) beam operations between January 18, 2019 and March 9, 2020. The following filtering steps were applied to collected data; (1) only 4 of the 17 signals per cavity are retained (GMES, GASK, CRFP, DETA2) (2) only events with data from each of the eight cavities in the cryomodule are kept, (3) only events that were sampled at 5 kHz were kept, (4) events from cryomodule 0L04 were neglected, (5) events occurring between February 4, 3PM and February 5, 12PM were neglected. As a result of preprocessing, the dataset is comprised of 2,375 unique events. The full dataset is comprised of three files: features.csv, cavity_labels.csv, fault_labels.csv. Each instance in faults.csv includes a timestamp (“date_time”), a label for the cryomodule which experienced the trip (“zone_label”), and 192 features (“feature_1”, “feature_2”... “feature_192”). The features correspond to 6 autoregressive features for each of 4 signals per cavity for each of the 8 cavities (6 × 4 signals/cavity × 8 cavities/cryomodule = 192). To deal with the large variation of signal amplitudes, time-series standardization via the z-score (standard score) function was applied prior to computing the features. For each instance, there is an associated label for the (1) cavity which faulted first (cavity_labels.csv) and (2) the type of fault that caused the trip (fault_labels.csv). The cavity identification can take values of [0, 1, 2, 3, 4, 5, 6, 7, 8] and the fault type can take values of [‘Microphonics’, ‘Quench_100ms’, ‘Controls_Fault’, ‘E_Quench’, ‘Quench_3ms’, ‘Single_Cav_Turn_Off’ , ‘Heat_Riser_Choke’, ‘Multi_Cav_Turn_Off’].
Traditional transmission line protection relies on predictable synchronous-based fault signatures, which frequently fail under the non-standard, current-limited fault characteristics of Inverter-Based Resources (IBRs). This study investigates how to achieve secure, communication-free fault isolation in IBR-dominated weak grids without relying on opaque, computationally heavy "black-box" machine learning algorithms. To address this, we propose a novel, standalone, and inherently interpretable data-driven protection framework. Unlike centralized methods requiring multi-terminal communication, this decentralized approach relies solely on local measurements using a hierarchical linear-kernel Support Vector Machine (SVM). The methodology decomposes the protection task into four sequential stages that mimic traditional protection elements: fault detection and fault direction identification, fault type classification, zone classification, and location estimation. This multi-stage architecture allows for specialized feature engineering at each stage, combining high computational efficiency with logic traceability. The framework's end-to-end performance was validated via C-code and PSCAD/EMTDC co-simulation, utilizing a real-world utility network and an OEM black-box IBR model. The proposed relay achieves 97.2% overall accuracy and provides a reliable trip decision within a 2.5-cycle window. The results confirm 100% accuracy in fundamental fault detection, reliable zone selectivity across low to moderate fault resistances, and robust security against non-fault transients, proving its immediate viability for integration into commercial numerical relays.
Not Available
Detecting and diagnosing HVAC faults is critical for maintaining building operation performance, reducing energy waste, and ensuring indoor comfort. An increasing deployment of commercial fault detection and diagnostics (FDD) software tools in commercial buildings in the past decade has significantly increased buildings’ operational reliability and reduced energy consumption. A massive amount of data has been generated by the FDD software tools. However, efficiently utilizing FDD data for ‘big data’ analytics, algorithm improvement, and other data-driven applications is challenging because the format and naming conventions of those data are very customized, unstructured, and hard to interpret. This paper presents the development of a unified taxonomy for HVAC faults. A taxonomy is an orderly classification of HVAC faults according to their characteristics and causal relations. The taxonomy includes fault categorization, physical hierarchy, fault library, relation model, and naming/tagging scheme. The taxonomy employs both a physical hierarchy of HVAC equipment and a cause-effect relationship model to reveal the root causes of faults in HVAC systems. A structured and standardized vocabulary library is developed to increase data representability and interpretability. The developed fault taxonomy can be used for HVAC system ‘big data’ analytics such as HVAC system fault prevalence analysis or the development of an HVAC FDD software standard. A common type of HVAC equipment-packaged rooftop unit (RTU) is used as an example to demonstrate the application of the developed fault taxonomy. Two RTU FDD software tools are used to show that after mapping FDD data according to the taxonomy, the meta-analysis of the multiple FDD reports is possible and efficient.
Identification and zonal classification of the faults is a decisive factor in the relay’s decision to trip or not. Different types of fault like three-phase, line-to-line-to-ground and single-line-to-ground can occur at various locations in the feeder. These faults are seen as the variation in the instantaneous values of three-phase voltages and currents, i.e., waveforms, that are measured at the relay location. The objective of this work is to develop a machine learning model that can identify a fault and classify it to various protection zones based on measured waveforms. In this work, a data-driven relay based on Convolutional Neural Network (CNN) is proposed for fault identification in distribution feeders with high penetration solar PV. The proposed CNN model takes local current and voltage waveforms as input and classify it into fault, no-fault or a capacitor switching. Further, the CNN also attempts to identify fault zones based on the images of waveforms. The overall testing accuracy of the trained model exceeds 95%.
Not provided.
Not Available
Earthquake-induced ground shaking near rupturing faults is highly sensitive to the rupture characteristics, seismic wave propagation patterns and site conditions, and field recordings of near-fault shaking are relatively sparse. These challenges complicate the assessment of the seismic performance of near-fault structures. A common approach to representing near-fault ground motion in engineering analysis is to explicitly consider and select records with strong directivity pulses (pulse records). We use three-dimensional high-resolution physics-based earthquake simulations to test this approach in the context of scenario-based ground motion record selection, and to study the important characteristics of near-fault ground shaking. We highlight the deficiencies associated with classifying near-fault simulated records as “pulse” or “non-pulse,” based on the presence of a single dominating pulse in the velocity time history. We show that this approach is inadequate for characterizing near-fault shaking on soft soils which can be dominated by both forward rupture directivity and basin amplification effects. We conduct ground motion selection experiments for the analysis of near-fault structures with and without explicit classification of the pulse features in the records, and evaluate the bias in the predicted structural demands. We find that the maximum interstory drift demands on building structures imposed by unscaled site-specific simulated ground motion records selected based on relevant spectral shape features are not sensitive to the classification of records as pulse/non-pulse. Therefore, with regard to predicting the maximum interstory drifts in near-fault buildings, we do not find justification for the binary pulse classification of near-fault records.
Marine hydrokinetic (MHK) turbines extract renewable energy from oceanic environments. However, due to the harsh conditions that these turbines operate in, system performance naturally degrades over time. Thus, ensuring efficient condition-based maintenance is imperative towards guaranteeing reliable operation and reduced costs for marine hydrokinetic power. This work proposes a novel framework aimed at identifying and classifying the severity of rotor blade pitch imbalance faults experienced by marine current turbines (MCTs). In the framework, a Continuous Morlet Wavelet Transform (CMWT) is first utilized to acquire the wavelet coefficients encompassed within the 1P frequency range of the turbine's rotor shaft. From these coefficients, several statistical indices are tabulated into a six-dimensional feature space. Next, Principle Component Analysis (PCA) is employed on the resulting feature space for dimensionality reduction, and then the application of a K-Nearest Neighbor (KNN) machine learning algorithm is utilized for fault detection and severity classification. The effectiveness of the proposed framework is validated using a high-fidelity MCT numerical simulation platform, where results demonstrate that the presence of a pitch imbalance fault can be accurately detected 100% of the time and correctly classified based upon severity more than 97% of the time.
Fault detection in Controller Area Network (CAN) systems is crucial for ensuring the reliability and safety of automotive and industrial applications. This study investigates and compares the effectiveness of time series classification models for supervised fault detection in CAN data. This repository contains the code and data for our benchmarking experiment aimed at detecting intermittent faults in automotive Controller Area Network (CAN) data. The goal of this project is to compare various machine learning (ML) and deep learning (DL) models using different Time Series Cross-Validation (TSCV) techniques to evaluate their effectiveness in a streaming environment for fault detection.
The timely detection of photovoltaic (PV) system failures is important for maintaining optimal performance and lifetime reliability. A main challenge remains the lack of a unified health-state architecture for the uninterrupted monitoring and predictive performance of PV systems. To this end, existing failure detection models are strongly dependent on the availability and quality of site-specific historic data. The scope of this work is to address these fundamental challenges by presenting a health-state architecture for advanced PV system monitoring. The proposed architecture comprises of a machine learning model for PV performance modeling and accurate failure diagnosis. The predictive model is optimally trained on low amounts of on-site data using minimal features and coupled to functional routines for data quality verification, whereas the classifier is trained under an enhanced supervised learning regime. The results demonstrated high accuracies for the implemented predictive model, exhibiting normalized root mean square errors lower than 3.40% even when trained with low data shares. The classification results provided evidence that fault conditions can be detected with a sensitivity of 83.91% for synthetic power-loss events (power reduction of 5%) and of 97.99% for field-emulated failures in the test-bench PV system. Finally, this work provides insights on how to construct an accurate PV system with predictive and classification models for the timely detection of faults and uninterrupted monitoring of PV systems, regardless of historic data availability and quality. Such guidelines and insights on the development of accurate health-state architectures for PV plants can have positive implications in operation and maintenance and monitoring strategies, thus improving the system’s performance.
The project demonstrates the value proposition for a high-resolution monitoring system (HRMS) with diagnostic-prognostic capability and determine its impact on LCOE. The HRMS differs from conventional monitoring systems in a number of ways. First it will include the capability to automatically measure IV curves at the string and module levels. This provides a much richer view into the DC performance of the PV system and allows classification of many typical failure and degradation modes. Second, it will incorporate software capable of quantifying power and energy losses in the field as well as define the location and mechanism of the power and energy loss. Moreover, we aimed to deliver a prognostic system that is capable of predicting certain failures before they occur and giving system operators the opportunity to more efficiently plan operations and maintenance (O&M) activity in order to lower costs and increase yield over the life of the system. The research identifies cost targets required for different monitoring stages, including at the string combiner, at the individual string, and at the module level, to lower the levelized cost of energy (LCOE). Finally, a comprehensive guide determines the value PV monitoring brings to PV field operations. The guide assists plant operators in maximizing value from existing plants and identify the trade-offs of different monitoring solutions for future plants depending on the size, location, and expected system lifetime.
An end-to-end supervised learning method is proposed for fault detection in the electric grid using Big Data from multiple Phasor Measurement Units (PMUs). The approach consists of preprocessing steps aimed at reducing data noise and dimensionality, followed by utilization of six classification models considered for detecting faults. Three of the models were variants of Convolutional Neural Network (CNN) architectures that consider a single type of measurement (voltage, current or frequency) at all PMUs or all types together also at all PMUs. CNN based models were compared to traditional methods of Logistic Regression (LR), Multi-layer Perceptron (MLP) and Support Vector Machine (SVM). Evaluation was conducted on two-year data measured by PMUs at 37 locations in a large electric grid. Here, the response variable for classification were extracted from the grid-wide outage event log. Experiments show that CNN-based models outperformed traditional methods on one year out-of-sample outage detection over the entire grid.