At least 55 records · Page 3

Cation Exchange Capacity, Anion Exchange Capacity, and Mineralogy of F-Area Aquifer Sediments

Strontium-90 (Sr-90) is a contaminant of concern in groundwater and surface water at both F-Area and H-Area Seepage Basins. This contaminant was disposed of, along with other heavy metals and radionuclides, into a series of unlined seepage basins from 1955 until 1988. The acidity of the wastewater increased Sr-90 mobility from the basin soil through the vadose zone and into the Upper Aquifer Zone (UAZ), creating a groundwater plume that discharges into wetlands areas and a local stream called Fourmile Branch.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development, Fabrication, and Testing of a Liquid/Liquid Microchannel Heat Exchanger for Constellation Spacecrafts

Minimizing mass and volume is critically important for space hardware. Microchannel technology can be used to decrease both of these parameters for heat exchangers. Working in concert with NASA, Pacific Northwest National Laboratories (PNNL) has developed a microchannel liquid/liquid heat exchanger that has resulted in significant mass and volume savings. The microchannel heat exchanger delivers these improvements without sacrificing thermal and pressure drop performance. A conventional heat exchanger has been tested and the performance of it recorded to compare it to the microchannel heat exchanger that PNNL has fabricated. The microchannel heat exchanger was designed to meet all of the requirements of the baseline heat exchanger, while reducing the heat exchanger mass and volume. The baseline heat exchanger was designed to have an transfer approximately 3.1 kW for a specific set of inlet conditions. The baseline heat exchanger mass was 2.7 kg while the microchannel mass was only 2.0 kg. More impressive, however, was the volumetric savings associated with the microchannel heat exchanger. The microchannel heat exchanger was an order of magnitude smaller than the baseline heat exchanger (2180cm3 vs. 311 cm3). This paper will describe the test apparatus designed to complete performance tests for both heat exchangers. Also described in this paper will be the performance specifications for the microchannel heat exchanger and how they compare to the baseline heat exchanger.

Hawkins-Reynolds, Ebony↗

Thermal insulation versus capacitance: A simulation experiment comparing effects of shade and hyporheic exchange on daily and seasonal stream temperature cycles

In streams where water temperatures stress native biota, management of riparian shade or hyporheic exchange are both considered viable management strategies for reducing the peaks of daily and seasonal stream channel temperature cycles. Although shade and hyporheic exchange may have similar effects on stream temperatures, their mechanisms differ. Improved understanding of the heat-exchange mechanisms influenced by shade and hyporheic exchange will aid in the appropriate application of either stream temperature management strategy. To illustrate a conceptual model highlighting shade as ‘thermal insulation’ and hyporheic exchange imparting ‘thermal capacitance’ to a stream reach, we conducted an in-silico simulation modelling experiment increasing shade or hyporheic exchange parameters on an idealized, hypothetical stream. We assessed the potential effects of increasing shade or hyporheic exchange on a stream reach using an established process-based heat-energy budget model of stream-atmosphere heat exchange and incorporated an advection-driven hyporheic heat exchange routine. The model tracked heat transport through the hyporheic zone and exchange with the stream channel, while including the effects of hyporheic water age distribution on upwelling hyporheic temperatures. Results showed that shade and hyporheic exchange similarly damped diurnal temperature cycles and differentially altered seasonal cycles of our theoretical stream. In winter, hyporheic exchange warmed simulated channel temperatures whereas shade had little effect. In summer, both shade and hyporheic exchange cooled channel temperatures, though the effects of shade were more pronounced. Our simple-to-grasp analogies of ‘thermal insulation’ for shade effects and ‘thermal capacitance’ for hyporheic exchange effects on stream temperature encourage more accurate conceptualization of complex, dynamic heat exchange processes among the atmosphere, stream channel, and alluvial aquifer.

54 ENVIRONMENTAL SCIENCES↗

Parametric Modeling and Economic Analysis of a 2MW th 3-Stream sCO 2 Heat Exchanger

Here, this paper presents the design and cost optimization of a novel 2MW th 3-stream sCO2 plate-fin heat exchanger. This heat exchanger design is unique in that it uses reduced metal oxide particle-to-sCO2 heat exchanger for cost-effective energy storage applications. The design uses low velocity, laminar air as the re-oxidizing reactant to transfer the heat of the re-oxidizing reaction to a sCO2 power loop. The design of the heat exchanger is based on a 2-D, 3-fluid plate/fin heat transfer model. The model parameterizes the size, shape, and number of passages of the heat exchanger to calculate the temperature profile, pressure drop, and fluid velocities of all three fluids. Global heat exchanger parameters such as the effectiveness and total heat transferred to the sCO2 are then calculated for overall performance. Due to the value and increased use of sCO2 heat exchangers in power cycles, a cost model of the system based on the unique high temperature/high pressure operating conditions was created using quotes from reference projects and market analysis. These quoted air-to-sCO2 heat exchangers are then processed using multiple weighting factors pertinent to heat exchanger design, including heat exchanger type, maximum temperature, differential pressures, fluids, duty, and more. These factors are then used in an exponential function in order to generate a parameterized cost curve. The design and cost of the heat exchanger are then optimized using the SMPSO genetic algorithm in Python. The optimization objectives for the system are to maximize the overall system effectiveness, including an air recuperator for preheating, and to minimize unit costs. Additional constraints are added to the system for the sCO2 and air pressure drops, air velocity to reduce particle entrainment, and the length and volume of the heat exchanger.

Cost Model↗

Demonstration of a multi-channel fluidized bed particle–supercritical carbon dioxide heat exchanger for concentrating solar applications

High-temperature thermal energy storage in oxide particles at temperatures above 600°C can couple concentrated solar energy with high-efficiency thermal power cycles to provide dispatchable solar-driven electricity. Challenges remain in developing cost-effective primary heat exchangers, which require expensive alloys, to extract the high-temperature thermal energy from the particles to power cycle fluids, such as supercritical CO 2 (sCO 2 ) in recuperated Brayton cycles. To explore one pathway for cost-effective, high-temperature particle heat exchangers, the current study demonstrates a shell-and-plate, particle–sCO 2 heat exchanger with narrow- channel fluidized beds coupled with micro-channel sCO 2 flows in the heat exchanger walls. This study evaluates the feasibility of multiple parallel, narrow-channel fluidized beds in shell-and-plate particle–sCO 2 HXs, to achieve high bed-wall heat fluxes at elevated temperatures. A reduced-order model simulates the narrow- channel, fluidized-bed particle–sCO 2 heat exchanger to design the fluidized bed geometry, in terms of depth, height, and number of channels,for a nominal 40-kWth heat exchanger at particle and sCO 2 inlet temperatures up to 600 °C and 400 °C respectively. The resulting shell-and-plate heat exchanger design operates with bubbling fluidization of the downward-flowing oxide particles to enhance bed-wall heat transfer. The heat exchanger core is fabricated with etched sCO 2 micro-channels in thin wall plates that are diffusion bonded to spacer frames to form the shell-and-plate structure with 12 parallel, fluidized bed channels, 10.4 mm deep. The heat exchanger is tested at the National Solar Thermal Test Facility at Sandia National Laboratories with CARBOBEAD HSP particles at design particle flow rates of 0.20 kg s –1 and inlet temperatures up to 525 °C. Results show that fluidization across multiple parallel channel beds can maintain uniform particle inventory with a common freeboard zone above the heat exchanger core. Bubbling fluidization improves particle–wall heat transfer coefficients but also increases axial dispersion of particle thermal energy, which lowers the log- mean temperature difference such that total heat transfer remains relatively constant to within ±10% over a broad range of fluidization gas velocities. The axial dispersion required particle and sCO 2 flow rates to be increased by 25% over model-designed conditions to achieve the targeted 40 kWth, which indicates the importance of incorporating axial dispersion into heat exchanger design models and of deploying bed structures to suppress it. Furthermore, this study demonstrates the feasibility and preferred fluidizing gas conditions for particle heat exchangers for releasing high-temperature thermal energy storage systems.

14 SOLAR ENERGY↗

Thermal Characterization of Acid Treated Anion Exchange Resins

Anion exchange is a chemical separation and purification technique in which a solid phase ion exchanging material (i.e., anion exchange resin beads) interchanges its anions with the desired anions from a solution phase. Typical anion exchange resins (e.g., Bio-Rad AG 1-X8 strongly basic anion exchange resin) consist of a polymer resin bead of cross-linked polystyrene with quaternary ammonium functional groups (Figure 1). Anion exchange occurs at the resin functional groups by exchange of the counter ion of the quaternary ammonium (typically chloride or nitrate) for the anionic species of interest. Other resin polymers have been developed—such as cross-linked vinylpyridine/divinylbenzene utilized in Reillex HPQ anion exchange resin—to improve the resins’ resistance against degradation by oxidizing agents, strong acids, and radiation. Anion exchange is performed for the separation of transuranic (TRU) elements throughout the Department of Energy complex. At the Los Alamos National Laboratory (LANL), production scale quantities of these resins are handled at the Chemistry and Metallurgy Research Facility, the Plutonium Facility, and the Transuranic Waste Facility. Spent anion exchange resin will eventually be disposed of as TRU waste. This has prompted concerns regarding its safe disposal under potential hazard scenarios, in particular a thermal excursion of a TRU waste drum. There is a concern that a potential thermal excursion of a TRU waste drum containing anion exchange resin previously contacted with nitric acid may result in energetic side reactions and pressure buildup due to resin degradation by nitric acid and heat. Therefore, the objective of the experiments described in this report was to gather qualitative and quantitative data to support decisions regarding the thermal stability and safe disposal strategy of nitric acid treated anion exchange resins utilized in TRU processing operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pressurized bellows flat contact heat exchanger interface

Disclosed is an interdigitated plate-type heat exchanger interface. The interface includes a modular interconnect to thermally connect a pair or pairs of plate-type heat exchangers to a second single or multiple plate-type heat exchanger. The modular interconnect comprises a series of parallel, plate-type heat exchangers arranged in pairs to form a slot therebetween. The plate-type heat exchangers of the second heat exchanger insert into the slots of the modular interconnect. Bellows are provided between the pairs of fins of the modular interconnect so that when the bellows are pressurized, they drive the plate-type heat exchangers of the modular interconnect toward one another, thus closing upon the second heat exchanger plates. Each end of the bellows has a part thereof a thin, membrane diaphragm which readily conforms to the contours of the heat exchanger plates of the modular interconnect when the bellows is pressurized. This ensures an even distribution of pressure on the heat exchangers of the modular interconnect thus creating substantially planar contact between the two heat exchangers. The effect of the interface of the present invention is to provide a dry connection between two heat exchangers whereby the rate of heat transfer can be varied by varying the pressure within the bellows.

Voss, Fred E.↗