Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Summary of Environmental Monitoring Recommendations for Marine Energy Development That Considers Life Cycle Sustainability

Recommendations derived from papers documenting the Triton Field Trials (TFiT) study of marine energy environmental monitoring technology and methods under the Triton Initiative (Triton), as reported in this Special Issue, are summarized here. Additionally, a brief synopsis describes how to apply the TFiT recommendations to establish an environmental monitoring campaign, and provides an overview describing the importance of identifying the optimal time to perform such campaigns. The approaches for tracking and measuring the effectiveness of recommendations produced from large environmental monitoring campaigns among the stakeholder community are discussed. The discussion extends beyond the initial scope of TFiT to encourage discussion regarding marine energy sustainability that includes life cycle assessment and other life cycle sustainability methodologies. The goal is to inspire stakeholder collaboration across topics associated with the marine energy industry, including diversity and inclusion, energy equity, and how Triton’s work connects within the context of the three pillars of energy sustainability: environment, economy, and society.

16 TIDAL AND WAVE POWER↗

MFRED, 10 second interval real and reactive power for groups of 390 US apartments of varying size and vintage

Abstract Building electricity is a major component of global energy use and its environmental impacts. Detailed data on residential electricity use have many interrelated research applications, from energy conservation to non-intrusive load monitoring, energy storage, integration of renewables, and electric vs. fossil-based heating. The dataset presented here, Multifamily Residential Electricity Dataset (MFRED), contains the electricity use of 390 apartments, ranging from studios to four-bedroom units. All apartments are located in the Northeastern United States (IECC-climate-zone 4 A), but differ in their heating/cooling system and construction year (early to late 20 th century). To adhere to privacy guidelines, data were averaged across 15 apartments each, based on annual electricity use. MFRED includes real and reactive power, at 10-second resolution, for January to December 2019 (246 million data points). The annual average real power per apartment is 343 W (3.27 W/m 2 of floor area), with strong variation between seasons and apartment size. Considering its large number of apartments, high time resolution, real and reactive power, and 12-month duration, MFRED is currently unique for the multifamily-sector.

97 MATHEMATICS AND COMPUTING↗

Mooring Load Monitoring of a Wave Energy Converter Using a Self-Synchronizing Underwater Acoustic Network

A self-synchronizing underwater acoustic network, designed for remote monitoring of mooring loads in Wave Energy Converters (WEC), has been developed and tested. This network uses Time Division Multiple Access and operates self-contained with the ability for users to remotely transmit commands to the network as needed. Each node is a self-contained unit, consisting of a protocol adaptor board, an underwater acoustic modem and a battery pack. A node can be connected to a load cell, to a topside user or to the WEC. Every node is swapable. The protocol adaptor board, named Protocol Adaptor for Digital LOad Cell (PADLOC) supports a variety of digital load cell message formats (CAN, MODBUS, custom ASCII) and underwater acoustic modem serial formats. PADLOC enables topside users to connect to separate load cells through a user-specific command.

acoustic↗

The total and spectral solar irradiance and its possible variations

The present status of knowledge of the total and spectral irradiance of the sun is briefly reviewed. Currently accepted values of the solar constant and the extraterrestrial solar spectral irradiance are presented along with a discussion of how they were derived. Data on the variability of the solar constant are shown to be conflicting and inconclusive. Some of the alleged sun-weather relationships are cited in support of the need of knowing more precisely the variations in total and spectral solar irradiance. An overview of a solar monitoring program is discussed, with special emphasis on the Solar Energy Monitor in Space experiment which was proposed for several spacecraft missions. It is a combination of a solar constant detector and a prism monochromator. The determination of absolute values and the possible variations of the total and spectral solar irradiance, from measurements outside of the atmosphere is discussed.

Thekaekara, M. P.↗

Solar irradiance - Total and spectral and its possible variations

The present status of our knowledge of the total and spectral irradiance of the sun is briefly reviewed. The currently accepted NASA/ASTM standard values of the solar constant and the extraterrestrial solar spectral irradiance are presented. The uncertainties in these values are relatively high. Data on the variability of the solar constant are conflicting and inconclusive. The variability of solar spectral irradiance is almost totally unknown and unexplored. Some alleged sun-weather relationships are cited in support of the need to know more precisely the variations in total and spectral solar irradiance. An overview of the solar monitoring program of NASA is presented, with special emphasis on the Solar Energy Monitor in Space (SEMIS) experiment which has been proposed for several spacecraft missions. The monitor is a combination of a solar-constant detector and a prism monochromator.

Thekaekara, M. P.↗

Barriers to Broader Utilization of Fault Detection Technologies for Improving Residential HVAC Equipment Efficiency

Faults in residential heating, ventilating, and air conditioning (HVAC) equipment may occur due to poor installation practices or develop over time, and these faults can negatively impact system efficiency, thermal comfort, and equipment lifespan. Automated fault detection and diagnostic (AFDD) technologies identify energy wasting HVAC faults, such as low indoor airflow and improper refrigerant charge, and guide technicians in improving system efficiency. For residential HVAC, AFDD consists of a range of fault detecting and diagnostic capabilities, sensor configurations, and target applications. AFDD technology can either be permanently installed by the original equipment manufacturer (OEM) using embedded sensors or as an add-on product either during or after installation. Additionally, several advanced installation tools and refrigerant gauge sets include AFDD features for temporary use during equipment installation and tune-ups. Some technologies can detect a fault but have limited diagnostic capabilities. For example, a single-point measurement from the home's thermostat or energy monitor can provide certain fault detection capability by analyzing the equipment runtime or energy consumption. These technologies, though limited at determining the cause of a given fault, may have significant energy savings potential due to their low cost and prevalence in the residential HVAC market. Despite the potential benefits, fault detection technologies face many technical and market barriers preventing broad adoption. Beyond the cost barriers due to the added sensor requirements and technology development, fault detection technologies face many implementation and adoption barriers such as installer training, customer awareness, standardized communication protocols, and methods of test for evaluating accuracy. The purpose of this whitepaper is to characterize market and technical barriers impeding broader utilization of fault detection technology for residential HVAC energy efficiency applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Continuous sensor suite measurements of weather, energy, soil and flux at four PumpHouse sites at the East River, Colorado

The purpose of this package is to monitor energy and water fluxes using a comprehensive set of sensors integrated on a tripod set up at 4 locations at the East River watershed in Colorado in the Upper Colorado River Basin as part of the Scientific Focus Area (SFA) research led by the Lawrence Berkeley National Lab (LBNL). This is a continuous sensor suite measurements of weather, energy, soil and flux at four East River pumphouse sites (ER-PHS1, ER-PHS2, ER-PHS3 and ER-PHS4) include: (1) soil CO2 concentration, CO2 flux and heat flux from soil surface; (2) photosynthetic active radiation flux at 1 m; (3) incoming/outcoming short and long wave radiation at 1 m, and user calculated net short and long wave radiation; (4) oxygen concentration and surface infrared temperature; (5) soil volumetric water content, temperature, and electrical conductivity at 10, 30, 60, 115 cm depth 115 cm depth; (6) soil matric potential and temperature at 30 cm depth; (7) incoming short wave radiation at 3 m height; (8) rainfall precipitation; (9) lightning strikes and strike distances; (10) wind direction and speed, maximum wind gust at 3 m; (11) air temperature, vapor pressure and barometric pressure at 3 m; (12) X _axis_level and Y_axis_level_(degree), tilt of the ATMOS 41 sensor; (13) maximum rainfall rate; (14) relative humidity sensor temperature at 3 m; (15) internally calculated vapor pressure deficit at 3 m with vapor pressure, relative humidity and sensor temperature measurements; (16) user calculated vapor pressure.These datasets contain data from Oct 11 2019 to March 20, 2020, and new datasets will be updated on annual basis. Files uploaded in Excel and Word, with copies in csv and pdf format.

54 ENVIRONMENTAL SCIENCES↗

Challenges and Opportunities for Basic Efficiency Measures in Low-Income Homes: A Southeast Alaska Case Study

Juneau, Alaska is the state's capital city and has a renewable energy goal to reach 80% renewable energy for the space heating and transportation sectors by 2045. In practical terms, this indicates a need to electrify both sectors, to take advantage of the inexpensive hydropower available from the local electric utility, Alaska Energy Light & Power. In an effort to complement and enable electrification, researchers examined the feasibility to deploy storm windows via a case study of installing storm windows in two local low-income homes. Newer models of storm windows provide an extra layer of insulation over existing windows, while preserving operability and views. They can also improve comfort and reduce noise. Researchers worked with the regional housing authority and a local builder to install the storm windows and replace inoperable windows in the two houses in 2021, in addition to conducting pre- and post-installation air leakage tests, energy monitoring, and occupant interviews. The team encountered several challenges, including a lack of egress windows, energy data from a wide variety of heating systems, extremely leaky homes, and installation issues such as windows that were not square. These results point to several barriers to widespread deployment of storm windows in the area, but also open the door to opportunities to design deployment programs that improve safety as well as efficiency.

cold climate↗

Atmospheric energy input and ionization by energetic electrons during the geomagnetic storm of 8-9 November 1991

The Atmospheric X-ray Imaging Spectrometer (AXIS) of the Particle Environment Monitor investigation aboard the Upper Atmosphere Research Satellite monitors energy input to the upper atmosphere due to energetic electrons. Analysis of the AXIS data from the major geomagnetic storm of 8-9 November 1991 is presented. During the November storm, electrons above a few keV flowing into a substantially expanded auroral zone provided the bulk of the ionizing power to the upper atmosphere. At the peak of the disturbance the total AXIS-observed power reached 40 GW. On 9 November the whole day average atmospheric ionization rate in the auroral zone at 80 km altitude exceeded the rate due to solar UV and solar X-rays by a factor of over 10 to 100.

Chenette, D. L.↗

Lidar System for Airborne Measurement of Clouds and Aerosols

A lidar system for measuring optical properties of clouds and aerosols at three wavelengths is depicted. The laser transmitter is based on a Nd:YVO4 laser crystal pumped by light coupled to the crystal via optical fibers from laser diodes that are located away from the crystal to aid in dissipating the heat generated in the diodes and their drive circuits. The output of the Nd:YVO4 crystal has a wavelength of 1064 nm, and is made to pass through frequency-doubling and frequency-tripling crystals. As a result, the net laser output is a collinear superposition of beams at wavelengths of 1064, 532, and 355 nm. The laser operates at a pulse-repetition rate of 5 kHz, emitting per-pulse energies of 50 microJ at 1064 nm, 25 microJ at 532 nm and 50 microJ at 355 nm. An important feature of this system is an integrating sphere located between the laser output and the laser beam expander lenses. The integrating sphere collects light scattered from the lenses. Three energy-monitor detectors are located at ports inside the integrating sphere. Each of these detectors is equipped with filters such that the laser output energy is measured independently for each wavelength. The laser output energy is measured on each pulse to enable the most accurate calibration possible. The 1064-nm and 532-nm photodetectors are, more specifically, single photon-counting modules (SPCMs). When used at 1064 nm, these detectors have approximately 3% quantum efficiency and low thermal noise (fewer than 200 counts per second). When used at 532 nm, the SPCMs have quantum efficiency of about 60%. The photodetector for the 355-nm channel is a photon-counting photomultiplier tube having a quantum efficiency of about 20%. The use of photon-counting detectors is made feasible by the low laser pulse energy. The main advantage of photon-counting is ease of inversion of data without need for complicated calibration schemes like those necessary for analog detectors. The disadvantage of photon-counting detectors is that they inherently have narrow dynamic ranges. However, by using photon-counting detectors along with a high-repetition rate laser, it is possible to obtain wide dynamic range through accumulation of counts over many pulses.

McGill, Matthew↗

Energy Efficiency Assistance for Galena Alaska

The City of Galena sits along the north bank of the Yukon River with no road access. Temperatures regularly reach negative 20°F in the winter and sunlight extends for up to 21 hours a day in the summer. Galena’s 400 residents, including members of the Koyukuk Athabascan culture, primarily use fuel oil and locally forested wood for heating and electricity generation. Because these resources are costly to obtain, local households have a high energy burden, spending 7% of their annual income on energy (averaging $4,000 per year). To reduce this burden, the City of Galena joined the U.S. Department of Energy’s (DOE) Remote Alaska Community Energy Efficiency (RACEE) Competition, where they received financial and technical assistance to implement energy savings solutions across their community, including building envelope improvements, solar panels, and LED lighting. Additionally, Galena installed new energy monitoring equipment to continue measuring the impacts of this work beyond the RACEE project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Monitoring of Photovoltaic (PV) Performance and Degradation: Integrated Renewable Energy Systems (IRES) - PV Monitoring Task

The Integrated Renewable Energy System (IRES) testbed demonstration at the Pacific Northwest National Laboratory (PNNL) Sequim campus includes development of a suite of capabilities for tracking the performance of photovoltaic (PV) renewable energy components located on a floating platform (floating PV) and on a shoreline building rooftop. The marine environment represents potentially harsh and corrosive conditions for PV modules. Compared to terrestrial PV, potential concerns for offshore PV arising from high humidity and occasional contact with saltwater, marine wildlife, and aquaculture. These environmental factors can reduce electricity generation efficiency and increase the risk of electrical faults, polymer insulation or jacketing degradation and hydrolysis of the PV cell encapsulant materials. Offshore PV modules may also be exposed to lower temperatures and buoyant and vibrating motions with a floating platform. It is not clear how the long-term performance of floating PV will be affected by these factors. To understand expected energy generation through solar cells on a floating platform, monitoring of the performance of PV modules in the marine environment is needed. This report outlines a plan for long-term testing of IRES PV components utilizing resources of the PNNL Material Aging and Detection (MAaD) Science team and the Marine and Coastal Research Laboratory (MCRL). Equipment applicable for onsite testing and real-time monitoring of the PV performance associated with environmental conditions including temperature, solar irradiance, shading and soiling is included. In case of performance loss, equipment for fault detection, failure analysis, material testing, and further troubleshooting are also available. Through establishment of this capabilities, the enabling IRES project sets the stage for future research to advance off-shore and near-shore energy options for businesses and communities.

14 SOLAR ENERGY↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

Power over Ethernet (PoE) technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras. They are systems that are familiar to and managed by on-site IT staff. As low voltage DC-power capabilities have increased with the advancement of IT network switches within offices, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. The connection of PoE devices to network switches offers the opportunity for energy monitoring and management to be performed through IT network management software. Data and results from technology validations of PoE equipment remain very limited. This lack of information hinders expansion of PoE as an energy management strategy as its benefits and challenges have been insufficiently quantified in real-world scenarios. This final report presents the findings of a DOE/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at six sites: two offices, three schools, and a hotel. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where not typically available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In-situ digital image correlation and thermal monitoring in directed energy deposition

A method and a system for digital image correlation and thermal monitoring during directed energy deposition are provided. The method and the system include global off-axis 3D mapping of surfaces features at high frame rates using the natural surface roughness of the additive build. Infrared thermography is projected onto these surface features to record the thermo-mechanical history of the finished component. As set forth herein, the method and the system provide a low-cost solution to monitoring and optimizing the unique temporal artifacts induced by complex scan strategies.

Haley, James↗

Western energy related overhead monitoring project. Phase 2: Summary

Assistance by NASA to EPA in the establishment and maintenance of a fully operational energy-related monitoring system included: (1) regional analysis applications based on LANDSAT and auxiliary data; (2) development of techniques for using aircraft MSS data to rapidly monitor site specific surface coal mine activities; and (3) registration of aircraft MSS data to a map base. The coal strip mines used in the site specific task were in Campbell County, Wyoming; Big Horn County, Montana; and the Navajo mine in San Juan County, New Mexico. The procedures and software used to accomplish these tasks are described.

Anderson, J. E.↗

Temporal variations of the anomalous oxygen component, 1977 - 1984

A survey is of the long term temporal variations of 6.6 to 12 MeV/nucleon anomalous oxygen at 1 AU covering the period 1977 to 1984. This time interval included the recent solar maximum, with the recovery at neutron monitor energies beginning in 1982. During this time interval, 6.6 to 12 MeV/nucleon 0 fluxes decreased by at least a factor of 50, and indeed remained below the instrumental detection threshold after 1979. By late 1984, neutron monitors had recovered to roughly 1979 levels from the 1982 solar maximum, and anomalous O still remained below the detection threshold.

Mason, G. M.↗

A Cybersecurity Threat Profile for a Connected Lighting System

In anticipation of improved energy performance and cost savings, cities and building owners are increasingly considering “smart lighting initiatives” that aim to convert their collection of simple luminaires (i.e., lighting fixtures) into an intelligent connected lighting system (CLS) capable of remotely monitoring energy consumption and fault conditions, and possibly implementing adaptive lighting schemes. The U.S. Department of Energy (DOE) has set an national goal of tripling the energy efficiency and demand flexibility of the buildings sector by 2030, relative to 2020 levels 1. It is forecast that connected lighting systems can contribute to that goal by delivering 125 TWh of annual energy savings by 2035 2, equivalent to the annual output of 50 typical (500 MW) power plants. However, these energy savings and the DOE goal are put at significant risk if connected technologies are not adopted due to real or perceived cybersecurity concerns. Connected IoT devices such as these have historically been rife with vulnerabilities which sometimes put security considerations secondary to functionality and operability. What are the cybersecurity threats that will impact these systems, as formerly banal luminaires transition into intelligent connected devices that collect information about themselves, their surrounding environment, and possibly us? In this paper we analyze a threat profile performed on a fault-detection use case for streetlights. A threat profile establishes security requirements, justifies security measures, yields actionable controls, and effectively communicates risk to stakeholders. This effort provides critical information for making threat-based decisions to increase security at a reasonable cost, and can effectively be used by development teams, software architects, and managers to make cybersecurity a part of their ongoing culture of awareness, training, and prevention. This leads to more secure systems and better-understood security. On-premise, cloud, and hybrid architectures with different authentication mechanisms were modeled and later categorized using the Microsoft STRIDE framework. An analysis of the recommended controls for each threat was performed to determine which controls could and should be put in place by manufacturers or third-party suppliers, and which controls need to be left up the end-user to implement. Fifty-seven threats were identified. Among our key findings: (1) 65% (37/57) of the threats did not involve the luminaires, but rather the other components needed to communicate with and manage them; (2) 63% (36/57) of the threats could have been mitigated through manufacturer-implemented defensive techniques or “controls”; and (3) 23% (13/57) of the threats were dependent on the network configuration. Recommendations based on the results of this work are made to key stakeholder groups. Notably, lighting technology developers are advised to address all threats that can be reasonably controlled with baked-in technology solutions (e.g., encryption or authentication controls), and employ some form of secure supply chain management and tracking where other parts (e.g., sensors, microprocessors) of a luminaire must also be built and manufactured with the proper security controls in place. Developers should also review threats involving assets not developed in-house to understand how connectivity with other devices will affect their product during system operation and determine if a compensating control for a defense-in-depth strategy will be needed. Finally, those interested in deploying CLS should compare the differences between cloud and on-premise models to determine which is more suitable for their needs and the abilities of their security team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Challenges and Opportunities for Basic Efficiency Measures in Low-Income Homes: A Southeast Alaska Case Study

Juneau, Alaska, is the state's capital city and aims to reach 80% renewable energy for the space heating and transportation sectors by 2045. This goal highlights a need to electrify both sectors to take advantage of the inexpensive hydropower available from the local electric utility, Alaska Electric Light and Power. To that end, researchers examined the feasibility of deploying storm windows via a case study of installing storm windows in two local low-income homes. Newer models of storm windows provide an extra layer of insulation over existing windows while preserving operability and views. They can also improve comfort and reduce noise. In addition to conducting pre- and post-installation air leakage tests, energy monitoring, and occupant interviews, researchers worked with the regional housing authority and a local builder to install the storm windows and replace inoperable windows in the two houses in 2021. The team encountered several challenges, including a lack of egress windows, energy data from a wide variety of heating systems, extremely leaky homes, and installation issues, such as windows that were not square. These results point to several barriers to the widespread deployment of window upgrades in the area and open the door to opportunities to design deployment programs that improve safety and efficiency.

cold climate↗