Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Energy management study for lunar oxygen production

Energy management opportunities in the process of hydrogen reduction of ilmenite for lunar oxygen production are being investigated. An optimal energy system to supply the power requirements for the process will be determined.

Fazzolare, R. A.↗

Testing of a Whole Home Energy Management System (Cooperative Research and Development Final Report)

NREL and B&B Technology Solutions Inc. will perform verification testing to demonstrate the effectiveness of our whole home energy management system. This energy management system will allow the electrification of various styles of homes reducing the emissions of CO2 by replacing existing fossil fuel-based home systems. CRADA benefit to DOE, Participant, and US Taxpayer: assists laboratory in achieving programmatic scope, and/or uses the laboratory's core competencies, and/or enhances U.S. competitiveness by utilizing DOE developed intellectual property and/or capabilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Turbine Electrified Energy Management for Single Aisle Aircraft

Electrified aircraft propulsion technology is being developed to reduce the environmental impacts of the aviation industry. This is prompting the exploration of potential uses and benefits of hybrid systems in which electric powertrains are integrated with more traditional gas turbine propulsion systems. Turbine Electrified Energy Management (TEEM) is an energy management approach for hybrid-electric architectures in which electric machines are connected to the turbofan shafts and used to suppress the off-design operation naturally associated with engine transients. This reduces the need to maintain a large amount of compressor operability margin, thus allowing further exploration of the engine design space. In this study, a 19,000 lbf engine within a parallel hybrid propulsion system is considered along with a 30,000 lbf standalone engine. Data from prior TEEM applications are used to approximate the electric machine sizing required to achieve operability benefits. The TEEM controller is shown to improve operability during transients through the reduction of stall margin undershoots and the decrease of transient variations in component performance maps by over 29%.

EAP↗

Federal Energy Management 101: Track 7, Session 1

Federal Energy Management 101: What are common building systems that use energy? This session will cover the basics of HVAC, Lighting, and Building Envelope and discuss how much energy each system tends to use within facilities - and how that changes across building types. Additionally, this session will cover identifying energy conservation measures (ECMs) and the process in which they are identified, funded, implemented, and savings are verified.

101↗

Networked Microgrid Energy Management Considering Ownership and Control Structures: A Comparison

With the growing deployment of microgrids, networked microgrids have emerged for their additional advantages of economy, reliability and resilience by coordinating the operation of multiple microgrids. As microgrids are operated with different ownership, objectives and functionalities, the formed networked microgrids show characteristics of mixed ownership, inconsistent objectives and various functionalities. To enable the coordinated operation of networked microgrids, three control structures, i.e., centralized, distributed and decentralized, have been constructed in the literature. However, the data sharing enabling these different paradigms and the resulted value propositions are not well defined, leading to poor resource management and resilience, etc. To solve this issue, a complete comparison of networked microgrid energy management under centralized, distributed and decentralized structures are performed. As a novel contribution, the required minimum data exchange of networked microgrid energy management under three control structures are identified, respectively. The value propositions are calculated and compared against each other by the results of case studies.

control structures↗

An Empirical Validation of a Constrained Bin Packing Algorithm for a Home Energy Management System

The increasing number of intelligent electrical appliances and home energy management systems provide a big opportunity for demand response services from residential and small commercial buildings to the grid. Simultaneously, direct control of individual devices by utilities can cause communication bottlenecks, as well as coordination and privacy concerns. These challenges can be addressed by combining the constituent devices into a single house battery equivalent for the purposes of demand response, using Minkowski sum and a 2d bin packing problem. However, the well-studied traditional problems have not been tested in a real house, as implementation carries significant challenges of its own. We deploy the packing problem on residential devices in a controllable house. We report the barriers we found, such as charge forecast and scalability of the algorithm, and discuss our solutions. The study serves as an intermediate step between existing theoretical research and possible future steps, such as prototype deployments of systems that provide residential demand response.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ten questions concerning reinforcement learning for building energy management

As buildings account for approximately 40% of global energy consumption and associated greenhouse gas emissions, their role in decarbonizing the power grid is crucial. The increased integration of variable energy sources, such as renewables, introduces uncertainties and unprecedented flexibilities, necessitating buildings to adapt their energy demand to enhance grid resiliency. Consequently, buildings must transition from passive energy consumers to active grid assets, providing demand flexibility and energy elasticity while maintaining occupant comfort and health. This fundamental shift demands advanced optimal control methods to manage escalating energy demand and avert power outages. Reinforcement learning (RL) emerges as a promising method to address these challenges. Here, in this paper, we explore ten questions related to the application of RL in buildings, specifically targeting flexible energy management. We consider the growing availability of data, advancements in machine learning algorithms, open-source tools, and the practical deployment aspects associated with software and hardware requirements. Our objective is to deliver a comprehensive introduction to RL, present an overview of existing research and accomplishments, underscore the challenges and opportunities, and propose potential future research directions to expedite the adoption of RL for building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid Energy Management with Real-Time Control of a High-Power EV Charging Site

Decarbonization of transportation systems is driving higher capacity energy storage and faster charging power requirements in electric vehicles (EVs). Given the potential advantages - such as increased efficiency, reduced inverter capacity, and less total cable mass - there is a demand in the industry for more DC distribution for high-power charging (HPC) hubs. However, the cost-effective, adaptive, and robust operation of the DC-coupled HPC hub necessitates a robust site energy management system (SEMS). Validating SEMS operation using a digital twin of an HPC hub in a real-time simulator (RTS) platform is crucial before field deployment. In this study, we propose a hybrid energy management site controller designed to achieve high-level, long-term operational objectives while managing low-level power sharing control between hub assets. We develop a centralized model predictive controller (MPC) to optimize hub operating points and use these points to update the droop parameters of the site energy storage system (ESS). This approach ensures the hub follows an optimal operating point while maintaining the flexibility to respond to load surges. We tested and verified our proposed approach both offline and on a Controller Hardware-in-the-loop (C-HIL) simulation platform integrated with a SEMS framework, demonstrating real-time site operation and validating a cost-effective and robust site controller.

ADVANCED PROPULSION SYSTEMS↗

A Mixed Integer Linear Programming-basedDistributed Energy Management for Three-phaseUnbalanced Active Distribution Network

A mixed integer linear programming (MILP)–baseddistributed energy management for three-phase unbalancedactive distribution network is proposed. Modern distributionnetworks have becoming more and more active with increasingdeployment of microgrids, distributed energy resources (DERs)as well as controllable loads. Considering various ownership andcontrol models of microgrids, DERs and controllable loads, adistributed energy management was formulated using the alternatingdirection method of multipliers (ADMM) algorithm. ByADMM, the distribution management system (DMS) and theseactive components are coordinated through price signals, whichare adjusted according to the generation-load mismatch per nodeper phase. To enable resolution of the ADMM-based distributedoptimization using more accessible and popular MILP solver,different linearization techniques were proposed to linearize theaugmented Lagrangian terms and other nonlinear terms. Resultsof case studies on a three-phase active distribution network withthree microgrids and several DERs and controllable loads validatedthe effectiveness of proposed MILP-based distributed energymanagement. In addition, the capability of proposed method inmitigating phase power unbalance has been demonstrated.

Liu, Guodong↗

Energy Management Operations for the InSight Solar-Powered Mission at Mars

This paper discusses how the change in launch date has changed the energy management challenges for InSight, and how the energy management approach for surface operations has been adapted to address those challenges. It also describes how energy balance and battery life are protected over the course of the InSight landed mission, in terms of a deliberate balance between autonomous on-board fault protection and ground commanding into reduced-load configurations that still make progress versus specific, prioritized mission success criteria. It describes the project’s unique statistical analysis and usage of Mars Exploration Rovers (MER) archived data on solar energy collection to develop and validate an explicit prelaunch margin policy versus energy reductions due to environment variability over multiple-sol sequences. And finally, the paper explains how this archived energy data has influenced the modification of the Phoenix-heritage autonomous fault protection, to guard against quickly-arising inclement power-generation conditions, such as rapid onset of a local dust storm or water ice cloud front.

Lisano II, MIchael E.↗

Transient Optimization for the Betterment of Turbine Electrified Energy Management

Gas turbine engine transients are associated with degraded compressor operability, which must be addressed by the engine control system and accounted for in the engine design. Failure to do so may result in events such as compressor stall/surge and combustor blow out. Transient operability concerns constrain the engine design and can result in sacrifices of efficiency and/or thrust responsiveness. The traditional approach to transient operability management is control logic that limits the fuel flow command. A companion paper presents a strategy for optimizing the transient fuel flow control logic taking into consideration transient operability and thrust responsiveness. The study covered here extends this idea to an electrified gas turbine engine that employs a power/energy management concept known as Turbine Electrified Energy Management (TEEM). TEEM uses an electric power system interfaced with the engine (hence the term ‘electrified gas turbine engine’) to further improve transient operability and alleviate associated design constraints. There can be costs associated with implementing TEEM in terms of power and energy requirements that impact the size of the electrical power system. However, the results of this study show that through optimization of the transient limit logic, power and energy requirements needed to implement TEEM can be significantly reduced. Among the conclusions that can be drawn from the results of the illustrative application covered herein are: (1) there is a reduction in the electric machine power requirement to manage operability during accelerations by 200 to 400 hp, and (2) power transfer from the low pressure spool (LPS) to the high pressure spool (HPS) is the most effective option for improving operability during decelerations, followed by the options of only injecting power on the HPS or only extracting power from the LPS.

Turbine Electrified Energy Management↗

Transient Optimization for the Betterment of Turbine Electrified Energy Management

Gas turbine engine transients are associated with degraded compressor operability, which must be addressed by the engine control system and accounted for in the engine design. Failure to do so may result in events such as compressor stall/surge and combustor blow out. Transient operability concerns constrain the engine design and can result in sacrifices of efficiency and/or thrust responsiveness. The traditional approach to transient operability management is control logic that limits the fuel flow command. A companion paper presents a strategy for optimizing the transient fuel flow control logic taking into consideration transient operability and thrust responsiveness. The study covered here extends this idea to an electrified gas turbine engine that employs a power/energy management concept known as Turbine Electrified Energy Management (TEEM). TEEM uses an electric power system interfaced with the engine (hence the term ‘electrified gas turbine engine’) to further improve transient operability and alleviate associated design constraints. There can be costs associated with implementing TEEM in terms of power and energy requirements that impact the size of the electrical power system. However, the results of this study show that through optimization of the transient limit logic, power and energy requirements needed to implement TEEM can be significantly reduced. Among the conclusions that can be drawn from the results of the illustrative application covered herein are: (1) there is a reduction in the electric machine power requirement to manage operability during accelerations by 200 to 400 hp, and (2) power transfer from the low pressure spool (LPS) to the high pressure spool (HPS) is the most effective option for improving operability during decelerations, followed by the options of only injecting power on the HPS or only extracting power from the LPS.

transient↗

Transient Optimization for the Betterment of Turbine Electrified Energy Management

Gas turbine engine transients are associated with degraded compressor operability, which must be addressed by the engine control system and accounted for in the engine design. Failure to do so may result in events such as compressor stall/surge and combustor blow out. Transient operability concerns constrain the engine design and can result in sacrifices of efficiency and/or thrust responsiveness. The traditional approach to transient operability management is control logic that limits the fuel flow command. A companion paper presents a strategy for optimizing the transient fuel flow control logic taking into consideration transient operability and thrust responsiveness. The study covered here extends this idea to an electrified gas turbine engine that employs a power/energy management concept known as Turbine Electrified Energy Management (TEEM). TEEM uses an electric power system interfaced with the engine (hence the term ‘electrified gas turbine engine’) to further improve transient operability and alleviate associated design constraints. There can be costs associated with implementing TEEM in terms of power and energy requirements that impact the size of the electrical power system. However, the results of this study show that through optimization of the transient limit logic, power and energy requirements needed to implement TEEM can be significantly reduced. Among the conclusions that can be drawn from the results of the illustrative application covered herein are: (1) there is a reduction in the electric machine power requirement to manage operability during accelerations by 200 to 400 hp, and (2) power transfer from the low pressure spool (LPS) to the high pressure spool (HPS) is the most effective option for improving operability during decelerations, followed by the options of only injecting power on the HPS or only extracting power from the LPS.

transient↗

Multi-layered Energy Management Framework for Extreme Fast Charging Stations Considering Demand Charges, Battery Degradation, and Forecast Uncertainties

To achieve a cost-effective and expeditious charging experience for extreme fast charging station (XFCS) owners and electric vehicle (EV) users, the optimal operation of XFCS is crucial. It is however challenging to simultaneously manage the profit from energy arbitrage, the cost of demand charges, and the degradation of a battery energy storage system (BESS) under uncertainties. This paper, therefore, proposes a multi-layered multi-time scale energy flow management framework for an XFCS by considering long- and short-term forecast uncertainties, monthly demand charges reduction, and BESS life degradation. In the proposed approach, an upper scheduling layer (USL) ensures the overall operation economy and yields optimal scheduling of the energy resources on a rolling horizon basis, thereby considering the long-term forecast errors. A lower dispatch layer (LDL) takes the short-term forecast errors into account during the real-time operation of the XFCS. Per the latest research, monthly demand charges can be as high as 90% of the total monthly bills for EV fast charging stations; to this end, this paper takes the first attempt at the reduction of demand charges cost by considering the trade-off between the energy cost and monthly demand charges. Contrasting literature, this work allocates an energy reserve in the BESS stored energy to deal with the impact of short-term forecast errors on the optimized real-time operation of the XFCS. Moreover, degradation modeling considers the trade-off between short-term benefits and long-term BESS life degradation. As a result, case studies and a comparative analysis prove the efficacy of the proposed framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

About the Federal Energy Management Program (FEMP)

The federal government is the nation's largest energy consumer. Mandated by law, the Federal Energy Management Program (FEMP) works with its stakeholders to enable federal agencies to meet energy-related goals, identify affordable solutions, facilitate public-private partnerships, and provide energy leadership to the country by identifying government best practices.

Federal Energy Management Program↗

Turbine Electrified Energy Management for Single Aisle Aircraft

Electrified aircraft propulsion technology is being developed to reduce the environmental impacts of the aviation industry. This is prompting the exploration of potential uses and benefits of hybrid systems in which electric powertrains are integrated with more traditional gas turbine propulsion systems. Turbine Electrified Energy Management (TEEM) is an energy management approach for hybrid-electric architectures in which electric machines are connected to the turbofan shafts and used to suppress the off-design operation naturally associated with engine transients. This reduces the need to maintain a large amount of compressor operability margin, thus allowing further exploration of the engine design space. In this study, a 19,000 lbf engine within a parallel hybrid propulsion system is considered along with a 30,000 lbf standalone engine. Data from prior TEEM applications are used to approximate the electric machine sizing required to achieve operability benefits. The TEEM controller is shown to improve operability during transients through the reduction of stall margin undershoots and the decrease of transient variations in component performance maps by over 29%.

Controls↗

A Control Strategy for Turbine Electrified Energy Management

Hybrid electric propulsion architectures provide the infrastructure to enable additional benefits to the propulsion system that are otherwise unrealizable with the sole use of the current, state-of-the-art, gas-driven, turbine engines. The presence of electric machines (EMs) coupled to the shaft(s) of the turbine engine provide the ability to actively alter the operation of the engine to the benefit of the propulsion system and the aircraft it propels. This is the goal of the Turbine Electrified Energy Management (TEEM) concept, which at its broadest level addresses the management of energy across the electrified propulsion system. Prior work has demonstrated the use of this concept to alter steady-state operation and improve transient operability of a hybrid-electric propulsion system. The main benefits previously illustrated include the elimination of stability bleeds and expansion of the turbomachinery design space in order to enable more efficient designs. This paper focuses on the development of control strategies to implement the TEEM concept, and it explores several possible architecture variants for applying this concept. Comparison studies are conducted between a purely gas-driven turbofan (baseline engine configuration) and TEEM augmented variants of the baseline engine. The variants are distinguished by the shaft(s) that possess an EM. The configurations consider EMs on both shafts, an EM on the high pressure spool (HPS) only, and an EM on the low pressure spool (LPS) only. These configurations are referred to as the dual-spool configuration, the HPS configuration, and LPS configuration, respectively. The studies expose several options in configuring and controlling the system, including the use of a single EM coupled to a single shaft of a two-spool engine to positively impact the operability of both shafts. The studies also demonstrate the use of independently designed controllers for the electric machine(s) that allow for a decoupled control design process.

Electrified↗

A Control Strategy for Turbine Electrified Energy Management

Hybrid electric propulsion architectures provide the infrastructure to enable additional benefits to the propulsion system that are otherwise unrealizable with the sole use of the current, state-of-the-art, gas-driven, turbine engines. The presence of electric machines (EMs) coupled to the shaft(s) of the turbine engine provide the ability to actively alter the operation of the engine to the benefit of the propulsion system and the aircraft it propels. This is the goal of the Turbine Electrified Energy Management (TEEM) concept, which at its broadest level addresses the management of energy across the electrified propulsion system. Prior work has demonstrated the use of this concept to alter steady-state operation and improve transient operability of a hybrid-electric propulsion system. The main benefits previously illustrated include the elimination of stability bleeds and expansion of the turbomachinery design space in order to enable more efficient designs. This paper focuses on the development of control strategies to implement the TEEM concept, and it explores several possible architecture variants for applying this concept. Comparison studies are conducted between a purely gas-driven turbofan (baseline engine configuration) and TEEM augmented variants of the baseline engine. The variants are distinguished by the shaft(s) that possess an EM. The configurations consider EMs on both shafts, an EM on the high pressure spool (HPS) only, and an EM on the low pressure spool (LPS) only. These configurations are referred to as the dual-spool configuration, the HPS configuration, and LPS configuration, respectively. The studies expose several options in configuring and controlling the system, including the use of a single EM coupled to a single shaft of a two-spool engine to positively impact the operability of both shafts. The studies also demonstrate the use of independently designed controllers for the electric machine(s) that allow for a decoupled control design process.

Energy management↗