Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “emittance measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Four-dimensional emittance measurement at the Spallation Neutron Source

A coasting hadron beam with an elliptical transverse profile, uniform charge density, and small transverse four-dimensional (4D) emittance could improve accelerator performance in several contexts. A phase space painting method to generate such a distribution is being tested in the Spallation Neutron Source (SNS) accumulator ring. A critical component of these efforts is to measure the 4D emittance of the beam during accumulation. The 4D emittance can be reconstructed from measured beam profiles in two ways: in the multi-optics method, the optics between a reconstruction and measurement location are varied; in the fixed-optics method, multiple measurement locations are used without modifying the optics. The fixed-optics method is faster but can lead to large uncertainty in the reconstructed 4D emittance. In this paper, we implement a variant of the multi-optics method using the four available wire-scanners near the SNS target. We also modify the wire-scanner region to reduce the uncertainty of the fixed-optics method. We then demonstrate the usefulness of the fixed-optics method by reconstructing the 4D emittance evolution during accumulation in the SNS ring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emittance measurements of RCG coated Shuttle tiles

The spectral and total normal emittance of the Reaction Cured Glass (RCG) coating used on Shuttle tiles has been measured for surface temperatures of 300 to 1905 K. These measurements were made on two virgin and two flown Shuttle tile samples. Room temperature directional emittance data were also obtained and used to determine the total hemispherical emittance of RCG as a function of temperature. The data obtained from this calculation indicate that the total hemispherical emittance decreases from a room temperature value of 0.83 to a value of 0.76 at 1905 K. The flown Shuttle tiles exhibited a change in the spectral distribution of emittance compared to that of the virgin tile, but no significant trends in the total emittance from a virgin to a flown tile could be established.

Bouslog, Stanley A.↗

A method of treating the non-grey error in total emittance measurements

In techniques for the rapid determination of total emittance, the sample is generally exposed to surroundings that are at a different temperature than the sample's surface. When the infrared spectral reflectance of the surface is spectrally selective, these techniques introduce an error into the total emittance values. Surfaces of aluminum overcoated with oxides of various thicknesses fall into this class. Because they are often used as temperature control coatings on satellites, their emittances must be accurately known. The magnitude of the error was calculated for Alzak and silicon oxide-coated aluminum and was shown to be dependent on the thickness of the oxide coating. The results demonstrate that, because the magnitude of the error is thickness-dependent, it is generally impossible or impractical to eliminate it by calibrating the measuring device.

Heaney, J. B.↗

The 3D clustering of Lyman Alpha Emitters measured with DESI

We present a clustering analysis of Lyman-$α$ emitters (LAEs) using spectroscopic observations from the Dark Energy Spectroscopic Instrument (DESI) of candidates selected from the Blanco/DECam Intermediate-Band Imaging Survey (IBIS). We measure the two-point correlation function and the power spectrum, including cross-correlations with DESI quasars. Using both analytical and halo occupation distribution (HOD) simulation-based modeling, we find a linear bias of $b \sim 2.31$--$2.62$ for LAEs over the redshift range $2.26 < z < 3.41$. The analytical modeling also provides constraints on the strength of radiative transfer effects, while the HOD analysis characterizes the LAE-halo connection across multiple models. Finally, we quantify the magnitude of non-perturbative clustering effects such as Fingers of God in the LAE population, providing essential input for the accurate modeling of LAE-based cosmological analyses in forthcoming high-redshift surveys such as DESI-II.

Ebina, H. [UC, Berkeley; LBL, Berkeley] (ORCID:000↗

Emittance measurements of Space Shuttle orbiter reinforced carbon-carbon

The spectral and total normal emittance of the Reinforced Carbon-Carbon (RCC) used on Space Shuttle nose cap and wing leading edges has been measured at room temperature and at surface temperatures of 1200 to 2100 K. These measurements were made on virgin and two flown RCC samples. Room temperature directional emittance data were also obtained and were used to determine the total hemispherical emittance of RCC as a function of temperature. Results of the total normal emittance for the virgin samples showed good agreement with the current RCC emittance design curve; however, the data from the flown samples showed an increase in the emittance at high temperature possibly due to exposure from flight environments.

Caram, Jose M.↗

Emittance measurements of Space Shuttle Orbiter Reinforced Carbon-Carbon

The spectral and total normal emittance of the Reinforced Carbon-Carbon (RCC) used on Space Shuttle Orbiter nose-cap and wing leading edges has been measured at room temperature and at surface temperatures of 1200 to 2100 K. These measurements were made on virgin and two flown RCC samples. Room temperature directional emittance data were also obtained and were used to determine the total hemispherical emittance of RCC as a function of temperature. Results of the total normal emittance for the virgin samples showed good agreement with the current RCC emittance design curve; however, the data from the flown samples showed an increase in the emittance at high temperature possibly due to exposure from flight environments.

Caram, Jose M.↗

Transverse Beam Emittance Measurement by Undulator Radiation Power Noise

Generally, turn-to-turn power fluctuations of incoherent spontaneous synchrotron radiation in a storage ring depend on the 6D phase-space distribution of the electron bunch. In some cases, if only one parameter of the distribution is unknown, this parameter can be determined from the measured magnitude of these power fluctuations. In this contribution, we report the results of our experiment at the Integrable Optics Test Accelerator (IOTA) storage ring, where we carried out an absolute measurement (no free parameters or calibration) of a small vertical emittance (5–15 nm rms) of a flat beam by this new method, under conditions, when the small vertical emittance is unresolvable by a conventional synchrotron light beam size monitor.

43 PARTICLE ACCELERATORS↗

Benchmarking the Use of BPM Quadrupole Moments to Measure Emittance

For the PIP-II program, transverse emittance in the Fermilab Booster must remain well controlled at higher bunch intensities. 4-plate beam position monitors (BPMs) have a small but measurable quadrupole moment, making it possible to infer transverse emittance. By compositing many BPMs together, it becomes possible to improve the quality of the quadrupole signal. The Fermilab Booster BPM system has been used to measure these quadrupole moments in the past year and derive emittances from them. Recent benchmarks show that the derived BPM emittances show similar emittance evolution and value to IPM and Multiwire data. This approach can both supplement and complement existing non-intercepting emittance monitors in accelerators.

Balcewicz, M. A. [Fermilab]↗

Benchmarking the Use of BPM Quadrupole Moments to Measure Emittance

For the PIP-II program, transverse emittance in the Fermilab Booster must remain well controlled at higher bunch intensities. 4-plate beam position monitors (BPMs) have a small but measurable quadrupole moment, making it possible to infer transverse emittance. By compositing many BPMs together, it becomes possible to improve the quality of the quadrupole signal. The Fermilab Booster BPM system has been used to measure these quadrupole moments in the past year and derive emittances from them. Recent benchmarks show that the derived BPM emittances show similar emittance evolution and value to IPM and Multiwire data. This approach can both supplement and complement existing non-intercepting emittance monitors in accelerators.

Balcewicz, Michael A. [Fermilab] (ORCID:0009000557↗

Determination and error analysis of emittance and spectral emittance measurements by remote sensing

The author has identified the following significant results. From the theory of remote sensing of surface temperatures, an equation of the upper bound of absolute error of emittance was determined. It showed that the absolute error decreased with an increase in contact temperature, whereas, it increased with an increase in environmental integrated radiant flux density. Change in emittance had little effect on the absolute error. A plot of the difference between temperature and band radiance temperature vs. emittance was provided for the wavelength intervals: 4.5 to 5.5 microns, 8 to 13.5 microns, and 10.2 to 12.5 microns.

Dejesusparada, N.↗

Emittance Measurements for a Thin Liquid Sheet Flow

The Liquid Sheet Radiator (LSR) is an external flow radiator that uses a triangular-shaped flowing liquid sheet as the radiating surface. It has potentially much lower mass than solid wall radiators such as pumped loop and heat pipe radiators, along with being nearly immune to micrometeoroid penetration. The LSR has an added advantage of simplicity. Surface tension causes a thin (100-300 microns) liquid sheet to coalesce to a point, causing the sheet flow to have a triangular shape. Such a triangular sheet is desirable since it allows for simple collection of the flow at a single point. A major problem for all external flow radiators is the requirement that the working fluid be of very low (approx. 10(sup -8) torr) vapor pressure to keep evaporative losses low. As a result, working fluids are limited to certain oils (such as used in diffusion pumps) for low temperatures (300-400 K) and liquid metals for higher temperatures. Previous research on the LSR has been directed at understanding the fluid mechanics of thin sheet flows and assessing the stability of such flows, especially with regard to the formation of holes in the sheet. Taylor studied extensively the stability of thin liquid sheets both theoretically and experimentally. He showed that thin sheets in a vacuum are stable. The latest research has been directed at determining the emittance of thin sheet flows. The emittance was calculated from spectral transmittance data for the Dow Corning 705 silicone oil. By experimentally setting up a sheet flow, the emittance was also determined as a function of measurable quantities, most importantly, the temperature drop between the top of the sheet and the temperature at the coalescence point of the sheet. Temperature fluctuations upstream of the liquid sheet were a potential problem in the analysis and were investigated.

Englehart, Amy N.↗

Theoretical and experimental emittance measurements for a thin liquid sheet flow

Surface tension forces at the edges of a thin liquid (approximately 200 microns) sheet flow result in a triangularly shaped sheet. Such a geometry is ideal for an external flow radiator. Since the fluid must have very low vapor pressure, Dow Corning 705 silicone oil was used and the emittance of a flowing sheet of oil was determined by two methods. The emittance was derived as a function of the temperature drop between the top of the sheet and the coalescence point of the sheet, the sink temperature, the volumetric flow and the length of the sheet. the emittance for the oil was also calculated using an extinction coefficient determined from spectral transmittance data of the oil. The oil's emittance ranges from .67 to .87 depending on the sheet thickness and sheet temperature. The emittance derived from the temperature drop was slightly less than the emittance calculated from transmittance data. An investigation of temperature fluctuation upstream of the slit plate was also done. The fluctuations were determined to be negligible, not affecting the temperature drop which was due to radiation.

Englehart, Amy N.↗

Longitudinal Emittance Measurements at PIP2IT

The PIP-II particle accelerator is a new upgrade to the Fermilab accelerator complex, featuring an 800-MeV H⁻ superconducting linear accelerator that will inject the beam into the present Fermilab Booster. A test accelerator known as PIP-II Injector Test (PIP2IT) has been built to validate the concept of the front-end of PIP-II. One of the paramount challenges of PIP2IT was to demonstrate a low longitudinal emittance at the end of the front end. Having a low longitudinal emittance is crucial in order to ensure the stability of the beam in the accelerator. We present a longitudinal emittance calculation at 14.3 MeV at the SSR1-8 cavity in the High Energy Transport line (HEBT). The signal is collected by a Fast Faraday Cup (FFC) at the end of HEBT and recorded by a high-bandwidth oscilloscope.

43 PARTICLE ACCELERATORS↗

Emittance Measurements with Wire Scanners in the Fermilab Side-coupled Linac

The Fermilab Side-Coupled Linac accelerates H-beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster synchrotron ring. These wire scanners act as important diagnostic instruments to directly collect information on the beam's transverse distribution. The manipulation of the conditions of wire scanner data collection enables further characterization of the beamline, such as calculating emittance and the Twiss parameters of the beam at select regions, which we present here.

43 PARTICLE ACCELERATORS↗

Emittance Measurements with Wire Scanners in the Fermilab Side-Coupled Linac

The Fermilab Side-Coupled Linac accelerates H- beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster synchrotron ring. These wire scanners act as important diagnostic instru-ments to directly collect information on the beam s transverse distribution. The manipulation of the condi-tions of wire scanner data collection enables further characterization of the beamline, such as calculating emittance and the Twiss parameters of the beam at select regions. Here we present the results of these studies and characterization of the non-Gaussian transverse beam distribution observed.

43 PARTICLE ACCELERATORS↗