Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS

We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k $\times$ 1k, 15 $\mu$m pixel, fully-depleted, $p$-channel devices that have been thinned to $\sim$250 $\mu$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., a single-sample readout noise $< 4.3$\,e$^-$\,rms/pixel, the ability to achieve multi-sample readout noise $\ll 1\,$e$^-$\,rms/pix, full-well capacities $\sim$40,000--65,000 e$^-$, low dark current and charge transfer inefficiency ($\sim 2$ $\times$ $10^{-4}$ e$^-$/pixel/s and 3.44 $\times$ $10^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim 80\%$ between 450\,nm and 980\,nm ($\gtrsim 90\%$ between 600\,nm and 900\,nm). We optimize the readout sequence timing to achieve sub-electron noise ($\sim 0.5$\,e$^-$\,rms/pix) and photon-counting ($\sim 0.22$\,e$^-$\,rms/pix) readout noise over an area of 2k $\times$ 4k and 110 $\times$ 4k pixels, respectively in a readout time of $\lesssim 17$min. We observed two Lyman-$\alpha$ emitting quasars (HB89\,1159$+$123 and QSO\,J1621$–$0042) at redshift $z \sim 3.5$, two moderate redshift galaxy clusters (CL\,J1001$+$0220 and SPT-CL\,J2040$-$4451), an emission line galaxy at $z = 0.3239$, a candidate member star of the Bo\"{o}tes~II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observation of the quasar HB89\,1159$+$123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvement for SIFS for observations in the low-background, readout-noise-dominated regime. We outline preliminary scientific studies that will leverage the SIFS-Skipper CCD data to derive new cosmological measurements in the context of dark matter and galaxy evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of an X-γ ray detection system based on a thick silicon LGAD

We present the performance of a X-γ ray detection systems based on a 300 µm thick silicon low-gain avalanche diode (LGAD) and of an equivalent Diode structure without the gain layer, read-out by a custom-made low-noise charge amplifier. For the LGAD structure, the multiplication gains M s from 10.2 to 19.3 are measured, and the Equivalent Noise Charge (ENC) components have been studied in detail. As expected, a significant reduction of the white and 1/f voltage series and dielectric ENC components is observed with increasing gain, shortening the optimum peaking time to τ = 0.4÷8 μs depending on the gain value, with respect to the standard diode, while the parallel ENC component increases proportionally to the gain up to M s = 15. Setting the gain M s = 12.7, a minimum ENC = 34.5 electrons r.m.s. (298 eV FWHM) at τ = 1 μs is found. However, the electronic noise, evaluated on the pulser FWHM, is found to only marginally contribute to the width of the spectral lines of a radioactive source, which are dominated instead by the statistical noise of the charge multiplication within the LGAD structure. The spectral lines' excess width is found to be proportional to the signal multiplication gain M s and increases with the energy of the photons. A minimum line width of 850 eV FWHM at 13.9 keV is measured at room temperature, τ = 2 μs and a gain M s = 10.2.

47 OTHER INSTRUMENTATION↗

The DarkNESS mission: probing dark matter with a Skipper-CCD satellite observatory

The invention of Skipper-CCDs with sub-electron noise has paved the way for groundbreaking low-threshold dark matter (DM) experiments, such as SENSEI and DAMIC. Conventionally, these experiments are deployed underground to mitigate cosmogenic backgrounds; however, some DM signatures are inaccessible to underground experiments due to attenuation in the Earth’s atmosphere and crust. The DarkNESS mission will deploy an array of Skipper-CCDs on a 6U CubeSat in Low Earth Orbit (LEO) to search for electron recoils from strongly-interacting sub-GeV DM as well as X-ray line signatures from sterile neutrino decay. Using a series of observations from LEO, the DarkNESS mission will set competitive upper limits on the DM-electron scattering cross section and help resolve the experimental conundrum associated with the purported observation of a 3.5 keV X-ray line, potentially produced from sterile neutrino decay. This work will describe the DarkNESS instrument, the technical challenges in operating Skipper-CCDs in the space environment, the scientific objectives of the DarkNESS mission, and the DM parameter space that DarkNESS will probe.

79 ASTRONOMY AND ASTROPHYSICS↗

Origin and characterization of single-electron events in Skipper-CCDs for light dark matter searches

This manuscript summarizes the work carried out within the SENSEI (Sub-Electron-Noise Skipper-CCD Experimental Instrument) collaboration, an effort focused on the search for light dark matter using Skipper-CCDs. Firstly, it presents the data acquisition and processing protocol developed to establish a selection criteria for events compatible with the dark matter signal. This protocol also enabled the structure and tools used for the study and characterization of phenomena that impact the quality of measurements made in the search for dark matter (measurement of the Fano factor, determination of the Compton background, and characterization of the high-energy surface background), which were carried out during this work. Secondly, it discusses the comprehensive study conducted on the origin of single-electron events in Skipper-CCDs, which allowed for the selection of detector operating parameters and improved the detection sensitivity in the search for dark matter. It is highlighted the characterization of the spatial correlation between single-electron events and high-energy events, among other developed event selection criteria, and the optimization of the output device to reduce sources of luminescence during its operation. As a result of this study, the lowest levels of dark current and spurious charge ever measured in a CCD are reported. Finally, the latest published results from SENSEI are presented. The obtained limits for the scattering of a light mediator are the best reported to date across the entire investigated mass range, while for the heavy mediator, they are the best for masses below 10 MeV. In terms of dark matter absorption, the most restringent limits below 10 eV are reported. These results, achieved with only a very small fraction of the total projected exposure for SENSEI, position Skipper-CCDs as leaders in the search for light dark matter worldwide.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasensitive Room Temperature Infrared Photodetection Using a Narrow Bandgap Conjugated Polymer

Abstract Photodetectors operating across the short‐, mid‐, and long‐wave infrared (SWIR–LWIR, λ = 1–14 µm) underpin modern science, technology, and society in profound ways. Narrow bandgap semiconductors that form the basis for these devices require complex manufacturing, high costs, cooling, and lack compatibility with silicon electronics, attributes that remain prohibitive for their widespread usage and the development of emerging technologies. Here, a photoconductive detector, fabricated using a solution‐processed narrow bandgap conjugated polymer is demonstrated that enables charge carrier generation in the infrared and ultrasensitive SWIR–LWIR photodetection at room temperature. Devices demonstrate an ultralow electronic noise that enables outstanding performance from a simple, monolithic device enabling a high detectivity ( D *, the figure of merit for detector sensitivity) >2.44 × 10 9 Jones (cm Hz 1/2 W −1 ) using the ultralow flux of a blackbody that mirrors the background emission of objects. These attributes, ease of fabrication, low dark current characteristics, and highly sensitive operation overcome major limitations inherent within modern narrow–bandgap semiconductors, demonstrate practical utility, and suggest that uncooled detectivities superior to many inorganic devices can be achieved at high operating temperatures.

36 MATERIALS SCIENCE↗

Characterization and pulse-shape discrimination of a multi-stacked structure of ZnS: Ag/PMMA for fast-neutron detection in high-flux environments

The Micro-Layered Fast Neutron Detector (MLFD) is a proton-recoil scintillator that incorporates the basic concept of a Hornyak button detector with an improved design using a layered structure of ZnS:Ag and PMMA (polymethyl methacrylate). The MLFD was predicted to have low sensitivity to gamma rays, hence pulse shape discrimination was performed to determine the gamma-ray contribution. Presented in this paper are the pulse-shape discrimination characteristics of the MLFD. Additionally, the charge integration technique was employed to discriminate between the neutrons and gamma rays using a fast digitzer. The MLFD was found to exhibit excellent neutron/gamma-ray discrimination, with the highest Figure-of-Merit (FoM) being 4.56. With PSD, the neutron signal is distinct from gamma-ray, Ĉerenkov and electronic noise signals. This clear separation was achieved due to the large differences in decay times of the neutron and gamma-ray-induced pulses in the ZnS:Ag phosphor. The MLFD can be employed in high gamma-ray exposure fields, up to at least 1287.7 mR/hr, without appreciable degradation in PSD performance.

47 OTHER INSTRUMENTATION↗

High event rate analysis technique for the dual-axis duo-lateral position-sensitive silicon detectors of FAUST

The dual-axis duo-lateral (DADL) position-sensitive silicon detector was developed to obtain precise position and energy information for detected charged particles. The Forward Array Using Silicon Technology (FAUST) is currently equipped with 68 DADL detectors backed by CsI(Tl) scintillators for the study of charged particle correlations in heavy-ion collisions where precise position and energy information is essential. When conventional signal processing electronics were used for the DADL detectors, a position dependence of the measured energy as well as distortions in the calculated particle positions were observed. In previous work, waveforms from the detector after preamplification were studied to better understand the features that give rise to these distortions; therein, a waveform analysis technique was developed to improve the energy resolution and linearity in position reconstruction. However, the reading and writing of waveforms for an entire detector array limits data collection rates and adds significant burden in data storage and analysis speed. In this work, the integrators of a Struck SIS3316 ADC were utilized to process 228 Th source data to develop and optimize a new analysis method that captures the benefits of the waveform analysis technique while circumventing the waveform writing requirement. This integrator method – capable of 59 keV (FWHM) energy resolution – was used in the collection of 35 MeV/nucleon 28 Si + 12 C collision data using FAUST to investigate exotic decays of highly excited highly deformed nuclei. In this data, a position resolution of 0.4 mm (FWHM) was obtained for 25 MeV α-particles; for α-particles near this energy that originate from 8 Be ground state decays, a 8 Be ground state width of 30 keV (FWHM) was obtained. The impact of the energy-dependent DADL position resolution emergent from electronic noise on the quality of excited state measurement was modeled and compared to the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-purity germanium semiconductor modeling in the detector response function toolkit

In this study, we have extended the detector response function toolkit (DRiFT) to provide modeling capabilities of semiconductor sensors. DRiFT provides realistic nuclear instrumentation response by post-processing Monte-Carlo N-particle (MCNP®) radiation transport outputs. MCNP® is capable of modeling radiation transport in complex environments, but has limited detector physics and readout electronics modeling capabilities. Semiconductor detector response can be calculated with a high-fidelity for a flexible range of environments by utilizing MCNP® to simulate radiation interactions inside of detector volumes, and then using DRiFT to model charge transport and signal formation in the semiconductor, as well as the readout electronics. DRiFT models charge transport in the semiconductor, the preamplifier, shaping amplifier, pulse pile-up, and electronic noise to generate detector response. The semiconductor application in DRiFT can model a range of semiconductor materials, shapes, and sizes; and is demonstrated here for a large volume coaxial high-purity germanium (HPGe) detector. Here, we compare detector response functions of a coaxial HPGe detector with measurement of 60 Co, 133 Ba, and 137 Cs at varying count rates, and we conduct a parameter study to demonstrate the effect of changing parameters in the DRiFT simulation. The HPGe detector response function shows excellent agreement with measurements of difference sources with varying dead times and count rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the use of neural networks for energy reconstruction in high-granularity calorimeters

We contrasted the performance of deep neural networks — Convolutional Neural Network (CNN) and Graph Neural Network (GNN) — to current state of the art energy regression methods in a finely 3D-segmented calorimeter simulated by GEANT4. This comparative benchmark gives us some insight to assess the particular latent signals neural network methods exploit to achieve superior resolution. A CNN trained solely on a pure sample of pions achieved substantial improvement in the energy resolution for both single pions and jets over the conventional approaches. It maintained good performance for electron and photon reconstruction. We also used the Graph Neural Network (GNN) with edge convolution to assess the importance of timing information in the shower development for improved energy reconstruction. We implement a simple simulation based correction to the energy sum derived from the fraction of energy deposited in the electromagnetic shower component. This serves as an approximate dual-readout analogue for our benchmark comparison. Although this study does not include the simulation of detector effects, such as electronic noise, the margin of improvement seems robust enough to suggest these benefits will endure in real-world application. We also find reason to infer that the CNN/GNN methods leverage latent features that concur with our current understanding of the physics of calorimeter measurement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The straw tracking detector for the Fermilab Muon g-2 Experiment

The Muon g-2 Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuum chamber in a region where the magnetic field is large and non-uniform. As such, the tracking detector must have a low leak rate to maintain a high-quality vacuum, must be non-magnetic so as not to perturb the magnetic field and, to minimize energy loss, must have a low radiation length. The performance of the tracking detector has met or surpassed the design requirements, with adequate electronic noise levels, an average straw hit resolution of (110 ± 20) μm, a detection efficiency of 97% or higher, and no performance degradation or signs of aging. The tracking detector's measurements result in an otherwise unachievable understanding of the muon's beam motion, particularly at early times in the experiment's measurement period when there are a significantly greater number of muons decaying. This is vital to the statistical power of the experiment, as well as facilitating the precise extraction of several systematic corrections and uncertainties. This paper describes the design, construction, testing, commissioning, and performance of the tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Erratum: Centrality-Dependent Modification of Jet-Production Rates in Deuteron-Gold Collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV [Phys. Rev. Lett. 116, 122301 (2016)]

We previously reported jet-production rates in 𝑝 + 𝑝 and 𝑑 + Au collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV recorded in 2008 with the PHENIX detector at the Relativistic Heavy Ion Collider. Subsequently, we found that electronic noise in the electromagnetic calorimeter was not completely removed by the tower-timing cuts used in the analysis. We have conducted an independent re-analysis of the data that eliminated noisy towers by removing them completely from the analysis. These cuts remove any contributions from instrumental noise, but reduce the overall acceptance for electromagnetic clusters by ≈16% and hence the overall statistical power of the data. Finally, this re-analysis found that instrumental noise in the electromagnetic calorimeter led to an artificial increase in the jet yield for both the 𝑝 + 𝑝 and 𝑑 + Au collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A new route to obtain fluorescence X-ray absorption spectra of compounds and to remove the self-absorption induced nonlinearity in the spectra

A new route to obtain fluorescence X-ray absorption spectra of compounds and to remove the self-absorption induced nonlinearity in the spectra is described. The fluorescent intensity If is linearly proportional to the absorption coefficient μ. For studies of surface structures around an element (κ) the fluorescence detection is often the mode of choice. However, the measurement may suffer from a self-absorption (SA) effect which nonlinearly distorts the spectra. The effect is severe when κ is concentrated or the measurements are carried out in certain geometries. Here, the correlations among emission events in compounds are examined following resonance X-ray core-electron excitation within κ. Under conditions leading to SA, If emitted from κ apparently has a conjugated relationship with the fluorescent intensities simultaneously emitted from other elements (ξ). Normalizing the former (κ) by the latter (ξ) will largely remove SA effects and reduce this nonlinear problem to a tractable linear problem. This does result in a moderate reduction of the spectral amplitude due to the so-called secondary emission from ξ excited by the emission from κ. Nonetheless, the resulting spectra will allow one to accurately determine bond distances and disorder and, in some respects, can be superior to spectra obtained via the absorption channel. For μξ < μκ and grazing incidence geometry, the amplitude reduction can be small and simple normalization is sufficient to restore the spectral integrity with remarkable accuracy. This has been instrumental in unravelling the surface and subsurface structures around cations in amorphous Ga–In–O and Zn–Sn–O films which are otherwise inaccessible due to severe SA effects. This method has also been applied to several samples with μξ ≃ μκ to examine its applicability. For these samples, the amplitude reduction is 12 ± 4% versus their standards for the data measured with the classical 45°/45° geometry. This experimental method is easy to implement. Since If from κ and ξ are measured by the same detector system, it is also superior to other methods in removing systematic errors such as detector system nonlinearity, electronic noise, and some beam instabilities, and in removing spectral imperfections due to, for example, SA effects, diffraction effects and sample inhomogeneity. The distortions resulting from the latter can be severe in the spectra measured in transmission mode.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Passive Inter-Photon Imaging

Digital camera pixels measure image intensities by converting incident light energy into an analog electrical current, and then digitizing it into a fixed-width binary representation. This direct measurement method, while conceptually simple, suffers from limited dynamic range and poor performance under extreme illumination --- electronic noise dominates under low illumination, and pixel full-well capacity results in saturation under bright illumination. We propose a novel intensity cue based on measuring inter-photon timing, defined as the time delay between detection of successive photons. Based on the statistics of inter-photon times measured by a time-resolved single-photon sensor, we develop theory and algorithms for a scene brightness estimator which works over extreme dynamic range; we experimentally demonstrate imaging scenes with a dynamic range of over ten million to one. The proposed techniques, aided by the emergence of single-photon sensors such as single-photon avalanche diodes (SPADs) with picosecond timing resolution, will have implications for a wide range of imaging applications: robotics, consumer photography, astronomy, microscopy and biomedical imaging.

97 MATHEMATICS AND COMPUTING↗

System-on-Chip approach microwave diagnostics development for burning plasma

System-on-chip (SoC) millimeter wave integrated circuit technology has been developed and employed in chip heterodyne radiometers in Electron Cyclotron Emission Imaging (ECEI) and Microwave Imaging Reflectometer (MIR) on the DIII-D tokamak for 2D electron temperature and density fluctuation diagnostics. The W-band (75-110 GHz) ECEI system has been employed with 20 poloidal horn receiver modules with customized monolithic integrated circuit chips and internal local oscillator coupling path. The new SoC approach demonstrates > 30 dB additional gain on the receiver and 95% electronics noise suppression compared to the previous Schottky diode mixer array . An F-band (110-140 GHz) receiver chip has been developed to measure MHD and turbulence behavior on the DIII-D high-field side, such as Alfven eigenmodes. Furthermore, it can image pedestal structure evolution on fusion facilities with stronger magnetic fields, such as ASDEX-U, EAST, HL-2M, and LHD. The F-band chip performance has been tested in the laboratory. Also, V-band (55-75 GHz) transmitter and receiver modules (55-75 GHz) have been developed for DIII-D and NSTX-U Furthermore, microwave Imaging Reflectometer (MIR) application suitability for 2D density fluctuation imaging on the pedestal region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enabling robust, stable, and accurate nonlinear optical measurements from squeezed light generated in hot rubidium vapor

The feasibility of nonlinear optical (NLO) imaging and spectroscopy using low intensity quantum states of light including entangled photon and squeezed light sources, such as those driven by two-photon absorption (TPA), has been a topic of ongoing debate. An unambiguous identification of the appreciable quantum advantage in such quantum light applications could enable NLO imaging of biological samples without photodegradation and phototoxicity. Recently, we have constructed a two-mode squeezed light source based on four-wave mixing in 85Rb vapor, which is capable of 7.9 dB of intensity-difference squeezing (IDS), corresponding to 8.7 dB upon electronic noise correction. In this talk, we discuss the stability of our system, including implementation details on achieving and maintaining 8.7 dB of IDS for several hours, and ensuring the two spatially multimode beams are properly overlapped in a sample with minimal optical loss.

Allen, Harry [ORNL] (ORCID:0000000190253914)↗

CEBAF Accelerator Tunnel Robot Project

Advancements in the field of robotics allow for the use of remotely controlled robots to perform tasks that have typically required human intervention. Jefferson Lab has explored the possibilities of robots placed in the accelerator tunnel to perform remote inspections that would otherwise require powering down equipment and completing lengthy radiological surveys that impact beam operations. A robotic solution ? driven by a human operator ? could not only reduce accelerator down time but also support the Lab's radiation exposure policy (known as "ALARA" - As Low As Reasonably Acceptable) by handling routine tunnel and beamline investigations in place of a human being. However, operating a remote device in a radioactive, high electronic-noise area is not a trivial task and drop-in solutions are rarely as simple as they seem. We will present the past prototypes that were tested as well follow-on technology developed from the project. We will also briefly survey current applications of robots at accelerator facilities with an eye toward future applications.

McGuckin, Theodore↗

SERAPH: Wavelike Dark Matter Searches with SRF Cavities

Haloscopes consisting of a microwave cavity with a high quality factor (Q) connected to low-noise electronics have been deployed to detect wavelike axions and dark photons. But the dark matter mass is unknown, so haloscopes must be tunable to search through the photon coupling vs. mass parameter space. Therefore, the scan rate for haloscope experiments is a crucial figure of merit and is proportional to the cavity’s quality factor. State-of-the-art experiments like ADMX currently use copper cavities with 𝑄∼80000. However, implementing superconducting cavities with 𝑄∼1010 can increase the instantaneous scan rate by possibly a factor of 105. This presentation will report progress on the SERAPH experiment, a family of superconducting haloscopes being developed by the Superconducting Quantum Materials and Systems (SQMS) Center. In this presentation, I will first discuss the principles behind operating a haloscope whose bandwidth is much narrower than the dark matter halo energy distribution. I will then describe the first SERAPH experiments implementing a 1.3 GHz Niobium cavity with an ultra-high quality factor (Q~1010) that has achieved the best sensitivity and deepest exclusion to wavelike dark photon dark matter by almost an order of magnitude. Next, I will discuss progress on the next phase of SERAPH, which will search dark photon dark matter using a widely-tunable SRF cavity (4-7 GHz). I will finally describe plans for subsequent SERAPH experiments to search for dark photons and axions with tunable SRF cavities tolerant to multi-Tesla magnetic fields and quantum sensors that subvert the Standard Quantum Limit.