Sixteen multiple-amplifier sensing charge-coupled devices and characterization techniques targeting the next generation of astronomical instruments

We present a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This type of charge-coupled device (CCD) sensor features multiple in-line amplifiers at its output stage allowing multiple measurements of the same charge packet, either in each amplifier or in the different amplifiers. Recently, the operation of an eight-amplifier sensor has been experimentally demonstrated, and we present the operation of a 16-amplifier sensor. This new sensor enables a noise level of ∼1 erms− with a single sample per amplifier. In addition, it is shown that sub-electron noise can be achieved using multiple samples per amplifier. In addition to demonstrating the performance of the 16-amplifier sensor, we aim to create a framework for future analysis and performance optimization of this type of detectors. New models and techniques are presented to characterize specific parameters, which are absent in conventional CCDs and Skipper CCDs: charge transfer between amplifiers and independent and common noise in the amplifiers and their processing.

16 multiple-amplifer sensing CCD (MAS-CCD)↗

Optical Displacement Sensor (ODS), a LISA's inertial reference sensor candidate.

We propose here an optical displacement sensor (ODS) as a supplemental or backup sensor for the LISA inertial reference sensor concept. This simple ODS consists of a laser diode and a quad-cell photodiode (both commercially available). The inertial mass’ reflective surface directs the laser beam onto the quad-cell photodiode. Changes in the inertial mass’ position and orientation are then extracted from ratios of the differences and sums of the quad-cell photodiode outputs. A simpler proto-type using a 200 microns wide slit has demonstrated a resolution of 10 nm/√Hz at 1 mHz and 1 nm/√Hz above 5 mHz. The electronics noise was 1 nm/√Hz at and above 1 mHz with simple and off the shelf electronics components. Although this ODs’ current performance does not meet the LISA’s system requirement’ of 1 nm/ at 1 mHz, we think that is achievable in the near future

Abramocivi, Alex↗

The Majorana Demonstrator readout electronics system

The M AJORANA D EMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76 Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the M AJORANA D EMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single-Shot Readout and Weak Measurement of a Tin-Vacancy Qubit in Diamond

The negatively charged tin-vacancy center in diamond (SnV − ) is an emerging platform for building the next generation of long-distance quantum networks. This is due to the SnV − ’s favorable optical and spin properties including bright emission, insensitivity to electronic noise, and long spin coherence times at temperatures above 1 K. Here, we demonstrate measurement of a single SnV − electronic spin with a single-shot readout fidelity of 87.4%, which can be further improved to 98.5% by conditioning on multiple readouts. In the process, we develop understanding of the relationship between strain, magnetic field, spin readout, and microwave spin control. We show that high-fidelity readout is compatible with rapid microwave spin control, demonstrating a favorable parameter regime for use of the SnV − center as a high-quality spin-photon interface. Finally, we use weak quantum measurement to study measurement-induced dephasing; this illuminates the fundamental interplay between measurement and decoherence in quantum mechanics, and provides a universal method to characterize the efficiency of color-center spin readout. Taken together, these results overcome an important hurdle in the development of the SnV − -based quantum technologies and, in the process, develop techniques and understanding broadly applicable to the study of solid-state quantum emitters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

Optical motion sensor for resonant-bar gravitational wave antennas

An experiment is described in which an optical method was used to measure fluctuations in the separation between two mirrors of a Fabry-Perot sensor cavity. Noise measurements were made to determine the sensitivity of this device to vibration amplitudes in the frequency range 1.1-2.1 kHz, which is of interest for resonant-bar gravitational wave antennas. The rms spectral noise density for length fluctuations in this range was sq rt 3.7 x 10 exp -15 m/Hz and can be related to electronic noise of the circuitry plus vibrational noise from the environment. The cavity finesse was relatively low at 117, and the power dissipated in the mirrors was estimated to be 1.9 micro-W. On a multimode gravitational wave detector, the sensor cavity would be formed by one reference mirror and by one mirror mounted on the last resonator. For a 1200-kg bar, 1.2-g last resonator system operating at 1600 Hz the sensor described here would exhibit a noise temperature of 18 micro-K; the resolution in h in the case of negligible thermal noise from the mechanical system would be sq rt 3.7 x 10 exp -18/Hz. Improvements in the sensitivity in a quiet antenna-like environment should be possible with higher finesse mirrors.

Richard, J.-P.↗

A Summary of the Status of the EOS Terra Mission Moderate Resolution Imaging Spectroradiometer (MODIS) and Attendant Data Product Development After One Year of On-Orbit Performance

The Moderate Resolution Imaging Spectroradiometer (MODIS) is well. The signal-to-noise (S/N) performance meets or exceeds specifications, band-to-band registration meets specifications, and geodetic registration of observations is near or at 50 meters (one sigma). Some problems with electronic noise, optical leaks, etc. have been identified and solutions to compensate or eliminate these effects have been successful. All approximately 40 data products are at 'Beta' status. Additional information is contained in the original extended abstract.

Salomonson, V. V.↗

Optical multiple access techniques for on-board routing

The purpose of this research contract was to design and analyze an optical multiple access system, based on Code Division Multiple Access (CDMA) techniques, for on board routing applications on a future communication satellite. The optical multiple access system was to effect the functions of a circuit switch under the control of an autonomous network controller and to serve eight (8) concurrent users at a point to point (port to port) data rate of 180 Mb/s. (At the start of this program, the bit error rate requirement (BER) was undefined, so it was treated as a design variable during the contract effort.) CDMA was selected over other multiple access techniques because it lends itself to bursty, asynchronous, concurrent communication and potentially can be implemented with off the shelf, reliable optical transceivers compatible with long term unattended operations. Temporal, temporal/spatial hybrids and single pulse per row (SPR, sometimes termed 'sonar matrices') matrix types of CDMA designs were considered. The design, analysis, and trade offs required by the statement of work selected a temporal/spatial CDMA scheme which has SPR properties as the preferred solution. This selected design can be implemented for feasibility demonstration with off the shelf components (which are identified in the bill of materials of the contract Final Report). The photonic network architecture of the selected design is based on M(8,4,4) matrix codes. The network requires eight multimode laser transmitters with laser pulses of 0.93 ns operating at 180 Mb/s and 9-13 dBm peak power, and 8 PIN diode receivers with sensitivity of -27 dBm for the 0.93 ns pulses. The wavelength is not critical, but 830 nm technology readily meets the requirements. The passive optical components of the photonic network are all multimode and off the shelf. Bit error rate (BER) computations, based on both electronic noise and intercode crosstalk, predict a raw BER of (10 exp -3) when all eight users are communicating concurrently. If better BER performance is required, then error correction codes (ECC) using near term electronic technology can be used. For example, the M(8,4,4) optical code together with Reed-Solomon (54,38,8) encoding provides a BER of better than (10 exp -11). The optical transceiver must then operate at 256 Mb/s with pulses of 0.65 ns because the 'bits' are now channel symbols.

Mendez, Antonio J.↗

Electron Ion Collider Strong Hadron Cooling design Summary

The Electron-Ion Collider (EIC) requires a high-energy cooler to maintain excellent beam quality and achieve high luminosity throughout long collision stores. To meet this requirement, the EIC project has adopted a novel approach known as Coherent Electron Cooling (CeC)—referred to as Strong Hadron Cooling (SHC)—which can provide rapid cooling rates at high energies. The SHC relies on an Energy Recovery Linac (ERL) to provide the intense, high-quality, and low-noise electron beam essential for the cooling process. This paper summarizes the design progress of the Strong Hadron Cooler for the EIC. We discuss key aspects of the project, including cooling physics modeling, luminosity evolution during collisions, the ERL design, risk mitigation strategies, remaining challenges, and ongoing R&D efforts.

43 PARTICLE ACCELERATORS↗

An Overview of the Earth Observing System MODIS Instrument and Associated Data Systems Performance

The Moderate Resolution Imaging Spectroradiometer (MODIS) on the Earth Observing System (EOS) Terra Mission began to produce data in February 2000. Now a little over 2 years from that time, the instrument continues to produce good data and products for land, oceans, and atmospheres studies are reaching or achieved maturity for science and applications studies. All subsystems of the instrument are performing as expected: the signal-to-noise (S/N) performance meets or exceeds specifications, band-to-band registration meets specifications, geodetic registration of observations is nearing 50 meters (one sigma) and the spectral bands are located where they were intended to be pre-launch and attendant gains and offsets are stable to date. Some problems with electronic noise, optical leaks, etc. have been identified and solutions to compensate or eliminate these effects have been successful. The data systems have produced a complete year or more for all data products extending from November 2000. Efforts are underway to provide data sets for the greater Earth science community and to improve access to these products at the various Distributed Active Archive Centers (DAAC's). The MODIS instrument on the EOS Aqua mission should also be expected to be in orbit and functioning in the Spring of 2002.

Salomonson, Vincent V.↗

Sensitivity Enhancement and Random Telegraph Noise in Magnetic Tunnel Junctions with Compensated Anisotropy

We demonstrate the manipulation of perpendicular magnetic anisotropy (PMA) in magnetic tunnel junctions (MTJs) by varying the layer stacks and temperature. PMA is tuned to compensate the shape anisotropy, giving a nonhysteretic magnetic response, a noteworthy sensitivity enhancement, and a field detectability of 1.8 nT/$\sqrt{Hz}$ at 100 kHz. Such a method is further exemplified in multiple MTJs, providing a solution to obtain desired sensitivities and operating temperatures. Additionally, the electronic noise of this MTJ is revealed as a random telegraph noise (RTN) due to a generation-recombination process. In conclusion, the observed voltage-dependent RTN could potentially be applied to true random number generators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS

We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k x 1k, 15 $\mu$m pixel, fully-depleted, p-channel devices that have been thinned to ~250 $\mu$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., single-sample readout noise < 4.3 e- rms/pixel, the ability to achieve multi-sample readout noise $\ll$ 1 e- rms/pixel, full-well capacities ~40,000-65,000 e-, low dark current and charge transfer inefficiency (~2 x 10$^{-4}$ e-/pixel/s and 3.44 x 10$^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim$ 80% between 450 nm and 980 nm ($\gtrsim$ 90% between 600 nm and 900 nm). We optimized the readout sequence timing to achieve sub-electron noise (~0.5 e- rms/pixel) in a region of 2k x 4k pixels and photon-counting noise (~0.22 e- rms/pixel) in a region of 220 x 4k pixels, each with a readout time of $\lesssim$ 17 min. We observed two quasars (HB89 1159+123 and QSO J1621-0042) at redshift z ~ 3.5, two high-redshift galaxy clusters (CL J1001+0220 and SPT-CL J2040-4451), an emission line galaxy at z = 0.3239, a candidate member star of the Bo\"{o}tes II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observations of the quasar HB89 1159+123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvements for SIFS observations in the low-background, readout-noise-dominated regime. We outline scientific studies that will leverage the SIFS-Skipper CCD data and new detector architectures that utilize the Skipper floating gate amplifier with faster readout times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS

We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k $\times$ 1k, 15 $\mu$m pixel, fully-depleted, $p$-channel devices that have been thinned to $\sim$250 $\mu$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., a single-sample readout noise $< 4.3$\,e$^-$\,rms/pixel, the ability to achieve multi-sample readout noise $\ll 1\,$e$^-$\,rms/pix, full-well capacities $\sim$40,000--65,000 e$^-$, low dark current and charge transfer inefficiency ($\sim 2$ $\times$ $10^{-4}$ e$^-$/pixel/s and 3.44 $\times$ $10^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim 80\%$ between 450\,nm and 980\,nm ($\gtrsim 90\%$ between 600\,nm and 900\,nm). We optimize the readout sequence timing to achieve sub-electron noise ($\sim 0.5$\,e$^-$\,rms/pix) and photon-counting ($\sim 0.22$\,e$^-$\,rms/pix) readout noise over an area of 2k $\times$ 4k and 110 $\times$ 4k pixels, respectively in a readout time of $\lesssim 17$min. We observed two Lyman-$\alpha$ emitting quasars (HB89\,1159$+$123 and QSO\,J1621$–$0042) at redshift $z \sim 3.5$, two moderate redshift galaxy clusters (CL\,J1001$+$0220 and SPT-CL\,J2040$-$4451), an emission line galaxy at $z = 0.3239$, a candidate member star of the Bo\"{o}tes~II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observation of the quasar HB89\,1159$+$123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvement for SIFS for observations in the low-background, readout-noise-dominated regime. We outline preliminary scientific studies that will leverage the SIFS-Skipper CCD data to derive new cosmological measurements in the context of dark matter and galaxy evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of an X-γ ray detection system based on a thick silicon LGAD

We present the performance of a X-γ ray detection systems based on a 300 µm thick silicon low-gain avalanche diode (LGAD) and of an equivalent Diode structure without the gain layer, read-out by a custom-made low-noise charge amplifier. For the LGAD structure, the multiplication gains M s from 10.2 to 19.3 are measured, and the Equivalent Noise Charge (ENC) components have been studied in detail. As expected, a significant reduction of the white and 1/f voltage series and dielectric ENC components is observed with increasing gain, shortening the optimum peaking time to τ = 0.4÷8 μs depending on the gain value, with respect to the standard diode, while the parallel ENC component increases proportionally to the gain up to M s = 15. Setting the gain M s = 12.7, a minimum ENC = 34.5 electrons r.m.s. (298 eV FWHM) at τ = 1 μs is found. However, the electronic noise, evaluated on the pulser FWHM, is found to only marginally contribute to the width of the spectral lines of a radioactive source, which are dominated instead by the statistical noise of the charge multiplication within the LGAD structure. The spectral lines' excess width is found to be proportional to the signal multiplication gain M s and increases with the energy of the photons. A minimum line width of 850 eV FWHM at 13.9 keV is measured at room temperature, τ = 2 μs and a gain M s = 10.2.

47 OTHER INSTRUMENTATION↗

The DarkNESS mission: probing dark matter with a Skipper-CCD satellite observatory

The invention of Skipper-CCDs with sub-electron noise has paved the way for groundbreaking low-threshold dark matter (DM) experiments, such as SENSEI and DAMIC. Conventionally, these experiments are deployed underground to mitigate cosmogenic backgrounds; however, some DM signatures are inaccessible to underground experiments due to attenuation in the Earth’s atmosphere and crust. The DarkNESS mission will deploy an array of Skipper-CCDs on a 6U CubeSat in Low Earth Orbit (LEO) to search for electron recoils from strongly-interacting sub-GeV DM as well as X-ray line signatures from sterile neutrino decay. Using a series of observations from LEO, the DarkNESS mission will set competitive upper limits on the DM-electron scattering cross section and help resolve the experimental conundrum associated with the purported observation of a 3.5 keV X-ray line, potentially produced from sterile neutrino decay. This work will describe the DarkNESS instrument, the technical challenges in operating Skipper-CCDs in the space environment, the scientific objectives of the DarkNESS mission, and the DM parameter space that DarkNESS will probe.

79 ASTRONOMY AND ASTROPHYSICS↗

Operation of a H4RG-10 in the NASA Goddard Astrophyiscs Divison IR Detector Lab Testbed

Future space and ground based missions in the near infrared are planning to or will utilize the next generation of Teledyne's HxRG detectors, the HgCdTe 4K x 4K array (H4RG). The science cases of such missions will require optimal stability and noise performance. To assess the detailed performance of the H4RG, we have developed a small single detector testbed in NASA Goddard's Astrophysics Division IR detector lab. The testbed operates a H4RG array inside a large dewar using a room temperature Leach controller. The dewar will include two integrating spheres with controlled apertures using NIR LEDs as light sources as well as a calibrated photodiode to precisely measure flux. We present preliminary results of a banded H4RG-10 array on the bench. In the near future, we plan to use the test bed to investigate the specific origins of electronic noise in the test bed, persistence, and other flux dependent nonlinearities.

Mosby, Gregory↗

Origin and characterization of single-electron events in Skipper-CCDs for light dark matter searches

This manuscript summarizes the work carried out within the SENSEI (Sub-Electron-Noise Skipper-CCD Experimental Instrument) collaboration, an effort focused on the search for light dark matter using Skipper-CCDs. Firstly, it presents the data acquisition and processing protocol developed to establish a selection criteria for events compatible with the dark matter signal. This protocol also enabled the structure and tools used for the study and characterization of phenomena that impact the quality of measurements made in the search for dark matter (measurement of the Fano factor, determination of the Compton background, and characterization of the high-energy surface background), which were carried out during this work. Secondly, it discusses the comprehensive study conducted on the origin of single-electron events in Skipper-CCDs, which allowed for the selection of detector operating parameters and improved the detection sensitivity in the search for dark matter. It is highlighted the characterization of the spatial correlation between single-electron events and high-energy events, among other developed event selection criteria, and the optimization of the output device to reduce sources of luminescence during its operation. As a result of this study, the lowest levels of dark current and spurious charge ever measured in a CCD are reported. Finally, the latest published results from SENSEI are presented. The obtained limits for the scattering of a light mediator are the best reported to date across the entire investigated mass range, while for the heavy mediator, they are the best for masses below 10 MeV. In terms of dark matter absorption, the most restringent limits below 10 eV are reported. These results, achieved with only a very small fraction of the total projected exposure for SENSEI, position Skipper-CCDs as leaders in the search for light dark matter worldwide.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasensitive Room Temperature Infrared Photodetection Using a Narrow Bandgap Conjugated Polymer

Abstract Photodetectors operating across the short‐, mid‐, and long‐wave infrared (SWIR–LWIR, λ = 1–14 µm) underpin modern science, technology, and society in profound ways. Narrow bandgap semiconductors that form the basis for these devices require complex manufacturing, high costs, cooling, and lack compatibility with silicon electronics, attributes that remain prohibitive for their widespread usage and the development of emerging technologies. Here, a photoconductive detector, fabricated using a solution‐processed narrow bandgap conjugated polymer is demonstrated that enables charge carrier generation in the infrared and ultrasensitive SWIR–LWIR photodetection at room temperature. Devices demonstrate an ultralow electronic noise that enables outstanding performance from a simple, monolithic device enabling a high detectivity ( D *, the figure of merit for detector sensitivity) >2.44 × 10 9 Jones (cm Hz 1/2 W −1 ) using the ultralow flux of a blackbody that mirrors the background emission of objects. These attributes, ease of fabrication, low dark current characteristics, and highly sensitive operation overcome major limitations inherent within modern narrow–bandgap semiconductors, demonstrate practical utility, and suggest that uncooled detectivities superior to many inorganic devices can be achieved at high operating temperatures.

36 MATERIALS SCIENCE↗