Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Pulsed, high-current, in-line reversal electron attachment detector

A new, pulsed, high-current, in-line reversal electron attachment ionizer/detector is described. The ionizer is capable of delivering a beam of electrons into an electrostatic mirror field to form a planar wall of electrons having zero kinetic energy. Electron attachment to a molecular target at the reversal point produces either parent or fragment negative ions through a zero-energy (s-wave) state. The atomic or molecular ion is pulsed out of the attachment region approximately 2 microsec after the electrons are pulsed off, and focused onto the entrance plane of a quadrupole mass analyzer. The sensitivity of the apparatus is preliminarily assessed, and its higher-energy behavior with regard to molecular attachment and ionization is described.

Bernius, Mark T.↗

Issues and directions in IR detector readout electronics

An introduction to the major issues encountered in the readout of imaging detector arrays in the infrared are presented. These include circuit issues such as multiplexing, buffering, and noise, as well as materials issues. Future directions in infrared readout electronics will also be discussed. These include on-chip signal processing and advanced hybridization schemes. Finally, recent work at Columbia on 2DEG-charge coupled devices for IR detector multiplexing are described.

Fossum, Eric R.↗

Polarized polymer films as electronic pulse detectors of cosmic dust particles

A new type of dust particle detector has been developed which consists of a polarized film of polyvinylidene fluoride (PVDF) having conducting electrons on its surface and operating with no bias voltage. Here, the response characteristics of PVDF detectors with areas in the range 4-150 sq cm and thickness in the range 2-28 microns to iron particles accelerated to velocities in the range 1-12 km/s are reported. The discussion also covers the mechanism of detection, fast pulse response, noise characteristics, and the dependence of the detector signal amplitude on particle mass and velocity. The detectors exhibit long-term stability and can be operated for extended periods of time over the temperature range -50 to +50 C; their response to dust particle impacts is unaffected by high background fluxes of charged particles.

Simpson, J. A.↗

A Hot-electron Direct Detector for Radioastronomy

A new approach is proposed to improve the sensitivity of direct-detection bolometers. The idea is to adjust a speed of the thermal relaxation of hot-electrons in a nanometer size normal metal or superconductive transition edge bolometer by controlling the elastic electron mean free path. If the bolometer contacts are made of a superconductor with high critical temperature then the thermal diffusion into the contacts is absent because of the Andreev's reflection and the electron-phonon relaxation is the only mechanism for heat removal. The relaxation rate should behave as 7(exp 4)l at subkelvin temperatures (l is the electron elastic mean free path) and can be reduced by factor of 10 - 100 by decreasing l. Then an antenna- or waveguide-coupled bolometer with a time constant approx. 10(exp -3) to 10(exp -5) S at T approx. = 0.1 - 0.3 K will exhibit photon-noise limited performance in millimeter and subn-millimeter range. The bolometer will have a figure-of-merit NEk square root of tau approx. = 10(exp -22) 10(exp -21) W/Hz at 100 mK which is 10(exp 3) times smaller than that of a state-of-the-art bolometer. This will allow for a tremendous increase in speed which will have a significant impact for observational mapping applications. Alternatively, the bolometer could operate at higher temperature with still superior sensitivity This research was performed by the Center for Space Microelectronics Technology, JPL, California Institute of Technology, under the contract for NASA.

Karasik, B. S.↗

Pyroelectric materials as electronic pulse detectors of ultraheavy nuclei

The design and testing of ultraheavy-nucleus pulse detectors based on pyroelectric materials are reported, extending the preliminary findings of Tuzzolino (1983) and Simpson and Tuzzolino (1983). Uranium-ion beams of about 240 MeV/u are detected by a 39.5-micron-thick Si detector, degraded to about 175 MeV/u by Al absorbers, and then strike 700-micron-thick polyvinylidene fluoride or 1000-micron-thick LiTaO3 pyroelectric samples. Both detector systems are connected to a coincidence circuit via charge-sensitive preamplifiers, shaping amplifiers with 30-microsec effective time constants, and electronic discriminators. Sample spectra are shown, and the pulse heights measured are found to agree with theoretical calculations to within a factor of about 2. The response of the pyroelectric materials is found to be unaffected by exposure to about 10 Mrad of 2-7-MeV/u heavy ion radiation. With further study and improvement of the detection sensitivity, devices of this type could be applied to large-area space measurements of low ultraheavy-ion fluxes.

Simpson, J. A.↗

Simulation and Characterization of a Miniaturized Scanning Electron Microscope

A miniaturized Scanning Electron Microscope (mSEM) for in-situ lunar investigations is being developed at NASA Marshall Space Flight Center with colleagues from the University of Alabama in Huntsville (UAH), Advanced Research Systems (ARS), the University of Tennessee in Knoxville (UTK) and Case Western Reserve University (CWRU). This effort focuses on the characterization of individual components of the mSEM and simulation of the complete system. SEMs can provide information on the size, shape, morphology and chemical composition of lunar regolith. Understanding these basic properties will allow us to better estimate the challenges associated with In-Situ Resource Utilization and to improve our basic science knowledge of the lunar surface (either precluding the need for sample return or allowing differentiation of unique samples to be returned to Earth.) The main components of the mSEM prototype includes: a cold field emission electron gun (CFEG), focusing lens, deflection/scanning system and backscatter electron detector. Of these, the electron gun development is of particular importance as it dictates much of the design of the remaining components. A CFEG was chosen for use with the lunar mSEM as its emission does not depend on heating of the tungsten emitter (lower power), it offers a long operation lifetime, is orders of magnitude brighter than tungsten hairpin guns, has a small source size and exhibits low beam energy spread.

Gaskin, Jessica A.↗

Ground Calibration of the Silicon Drift Detectors for NICER

The Neutron star Interior Composition ExploreR (NICER) is set to be deployed on the International Space Station (ISS) in early 2017. It will use an array of 56 Silicon Drift Detectors (SDDs) to detect soft X-rays (0.2 - 12 keV) with 100 nanosecond timing resolution. Here we describe the e ort to calibrate the detectors in the lab primarily using a Modulated X-ray Source (MXS). The MXS that was customized for NICER provides more than a dozen emission lines spread over the instrument bandwidth, providing calibration measurements for detector gain and spectral resolution. In addition, the fluorescence source in the MXS was pulsed at high frequency to enable measurement of the delay due to charge collection in the silicon and signal processing in the detector electronics. A second chamber, designed to illuminate detectors with either 55Fe, an optical LED, or neither, provided additional calibration of detector response, optical blocking, and effectiveness of background rejection techniques. The overall ground calibration achieved total operating time that was generally in the range of 500-1500 hours for each of the 56 detectors.

Silicon Drift Detectors↗

A detector for high frequency modulation in auroral particle fluxes

A high time resolution electron detector has been developed for use in sounding rocket studies of the aurora. The detector is used to look for particle bunching in the range 50 kHz-10 MHz. The design uses an electron multiplier and an onboard frequency spectrum analyzer. By using the onboard analyzer, the data can be transmitted back to ground on a single 93-kHz voltage-controlled oscillator. The detector covers the 50 kHz-10 MHz range six times per second and detects modulation on the order of a new percent of the total electron flux. Spectra are presented for a flight over an auroral arc.

Spiger, R. J.↗

Correlation of ground-based and topside photometric observations with auroral electron spectra measurements at rocket altitudes

Data are collected by electron detectors aboard a sounding rocket measuring the primary electron spectrum and the energy flux on the field lines containing auroral light in the E region. These data are compared to calculations based on spectroscopic measurements of the auroral lines 4278, 5577, and 6300 A used in predicting the energy influx and the characteristic energy of an assumed Maxwellian primary electron spectrum for two auroral displays. Data were also collected by photometers sampling the auroral light from the E region magnetically conjugate to the rocket. These data are compared to those of current ionospheric models.

Arnoldy, R. L.↗

Low voltage scanning electron microscopy of interplanetary dust particles

The resolution of available low-voltage SEM (LVSEM) models used in the characterization of interplanetary dust particles (IDPs) is limited by a number of factors including energy spread in the electron source, beam brightness, scanning electron detector geometry, and various lens aberrations. This paper describes an improved model of LVSEM which offers an increased resolution at low voltage. The improvements include a cold cathode FE source which has an extremely low inherent energy spread and high brightness, a second condenser lens to converge the beam and maintain an optimum aperture half-angle, and a detector optimized for low-voltage scanning-electron collection. To reduce lens aberrations, the specimen is immersed in the objective lens field. The features of several IDP samples observed using the images obtained with this LVSEM model are described.

Blake, D. F.↗

Comparing and Contrasting Detectors: JWST NIR vs HST WFC3

In many ways, WFC3s IR channel is a good indicator for what to expect with JWST. There are some differences, most of which should be beneficial in JWST- JWSTs lower operating temperature will freeze out charge traps that would affect WFC3. Benefits should include lower dark current, lower persistence, and better reciprocity- JWSTs more recent HgCdTe process has lower defect density. The benefits are as described above- JWST uses better indium barriers. The benefits should include fewer RC type pixels. One area where more study might be beneficial is stability. The detector electronics play a significant role in determining how stable a detector system is(v.s. bias drifts and photometry). JWSTs SIDECARs are completely WFC3s Ball electronics- Studies comparing the bias and photometric stability of WFC3 and JWST might be useful to informing data acquisition and calibration strategies for JWST.

NIR↗

Analysis of Technology for Compact Coherent Lidar

In view of the recent advances in the area of solid state and semiconductor lasers has created new possibilities for the development of compact and reliable coherent lidars for a wide range of applications. These applications include: Automated Rendezvous and Capture, wind shear and clear air turbulence detection, aircraft wake vortex detection, and automobile collision avoidance. The work performed by the UAH personnel under this Delivery Order, concentrated on design and analyses of a compact coherent lidar system capable of measuring range and velocity of hard targets, and providing air mass velocity data. The following is the scope of this work. a. Investigate various laser sources and optical signal detection configurations in support of a compact and lightweight coherent laser radar to be developed for precision range and velocity measurements of hard and fuzzy targets. Through interaction with MSFC engineers, the most suitable laser source and signal detection technique that can provide a reliable compact and lightweight laser radar design will be selected. b. Analyze and specify the coherent laser radar system configuration and assist with its optical and electronic design efforts. Develop a system design including its optical layout design. Specify all optical components and provide the general requirements of the electronic subsystems including laser beam modulator and demodulator drivers, detector electronic interface, and the signal processor. c. Perform a thorough performance analysis to predict the system measurement range and accuracy. This analysis will utilize various coherent laser radar sensitivity formulations and different target models.

Amzajerdian, Farzin↗