Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron cyclotron emission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Escape of fundamental electron-cyclotron maser emission from the sun and stars

It is shown that fundamental x-mode emission from flaring regions can undergo partial mode conversion at the second-harmonic absorption layer, with a fraction emerging in the o mode through a window near theta = 90 deg; fundamental o-mode radiation can emerge through this window directly. The optical depth for mode-converted x-mode radiation is up to 200 times less than the depth tau(x) for unconverted radiation; the o-mode depth is up to c-squared/V-squared (roughly 1000) times smaller than tau(x), where V is the thermal velocity of the plasma. This mechanism is linear and threshold-free, requires little scattering or refraction of the emitted radiation, and permits the strongest instability (fundamental x-mode) to dominate in producing the observed emission.

Robinson, P. A.↗

Rotational modulation and flares on RS Canum Venaticorum and BY Draconis stars. 18: Coordinated VLA, ROSAT, and IUE observations of RS CVn binaries

As part of a coordinated program of multi-wavelength observations of RS CVn close binary systems, we observed 15 systems with the Very Large Array (VLA) and 10 systems with IUE, simultaneously or nearly simultaneously with the ROSAT All Sky Survey observations of these stars. Of the 22 systems observed with ROSAT, three were observed both by IUE and the VLA. Radio observations were made at 3.6, 6 and 20 cm. Of the 15 observed RS CVn systems, we detected 11 with greater than 4 sigma confidence at one or more wavelengths. The IUE observations were made within the RIASS (ROSAT-IUE All Sky Survey) program. We present the results of the VLA observations, along with the corresponding subsets of the ROSAT Position Sensitive Proportional Counter (PSPC) X-ray and Wide Field Camera (WFC) XUV survey, and RIASS IUE observations. We obtained an extended VLA/IUE/ROSAT simultaneous coverage of one system, TY Pyx, covering more than one orbital period. These observations reveal that the quiescent radio flux of TY Pyx is relatively constant over time scales of up to 7 hours, but that it did change by a factor of 3 over 24 hours, probably due to a flare on 1990 Nov. 12. The UV, XUV and X-ray fluxes do not show large day-to-day or phase-related variability. The observation of the decay phase of a radio flare on EI Eri, with no accompanying X-ray or XUV flare, suggests that the lack of a strong correlation between X-ray and radio flares previously noted for dMe flare stars holds for RS CVn systems as well. We suggest that the radio flare may have been due to a coherent emission process such as electron cyclotron emission. The simultaneous measurements presented here provide a unique test of the general correlation between radio and soft X-ray luminosities, L(sub radio) approximately L(sub x exp m) (Drake et al. 1989) with a power-law slope close to unity, which was previously derived using data obtained years apart. Our derived slopes are consistent with and thus support the general correlations between coronal and chromospheric/transition region emissions previously derived from nonsimultaneous measurements of a much larger sample of these variable sources. However, the importance of simultaneous measurements for accurate energy balance calculations is stressed.

Fox, David C.↗

Gyrokinetic profile prediction and validation of a negative triangularity plasma in ASDEX Upgrade

In this work, gyrokinetic simulations are performed with the CGYRO code (Candy et al 2016 J. Comput. Phys. 324 73–93) for a negative triangularity H-mode plasma in ASDEX Upgrade, and compared with experimental measurements. The PORTALS framework (Rodriguez-Fernandez et al 2024 Nucl. Fusion 64 076034) is used to accelerate the prediction of kinetic profiles for this plasma, using surrogate modeling and Bayesian optimization. Ion heat flux, electron heat flux, and electron particle flux are simultaneously matched across the simulated radial regime of the plasma (normalized radius $r/a = 0.35-0.90$), and the resulting ion temperature, electron temperature, and electron density profiles match well with the experimental profile data within this radial range. A synthetic Correlation Electron Cyclotron Emission diagnostic is applied to find well-matched electron temperature fluctuation properties between simulation and experiment. The flux-matched profiles provide a basis for investigation of the turbulence nature across the plasma radius, revealing the dominance of Trapped Electron Mode turbulence at $r/a = 0.35$, the dominance of Ion Temperature Gradient turbulence at $r/a = 0.55$, 0.75, and 0.83, and an instability boundary at $r/a = 0.90$.

gyrokinetic simulation↗

Ganymede: A New Radio Source

Observations by the Galileo plasma wave receiver during the first two flybys of Ganymede revealed that this Jovian moon is the source of narrowband electromagnetic radio waves, making it the only satellite in the solar system known to generate non-thermal radio emissions. The emissions are the result of mode-coupling from electrostatic electron cyclotron emissions mu the upper hybrid resonance frequency, similar to non-thermal continuum radiation found at the known magnetized planets.

Kurth, W. S.↗

Synchrotron emissivity near the electron cyclotron and upper hybrid frequencies

The spontaneous synchrotron emissivity from a high density, weakly relativistic plasma in thermal equilibrium is discussed. Thermal effects on the dielectric polarization of the plasma are included in the analysis, and the result is compared with computations of the emissivity based upon the cold plasma approximation. A numerical analysis is performed for frequencies in the vicinity of both the electron cyclotron frequency and the upper hybrid resonance. Significant modifications to the synchrotron emissivity in the cold plasma approximation are found in both of these frequency regimes.

Freund, H. P.↗

Plasma confinement state classification via FPP relevant microwave diagnostics

We present a parsimonious and robust machine learning approach for identifying plasma confinement states in fusion power plants (FPPs) where reliable identification of the low-confinement and high-confinement regimes is critical for safe and efficient operation. Unlike research-oriented devices, FPPs must operate with a severely constrained set of diagnostics. To address this challenge, we demonstrate that a minimalist model, using only electron cyclotron emission (ECE) signals, can achieve accurate and reliable state classification. ECE provides electron temperature profiles without the engineering or survivability issues of in-vessel probes, making it a primary candidate for FPP-relevant diagnostics. Our framework employs ECE as input, extracts features using radial basis functions, and applies a gradient boosting classifier, achieving a test accuracy of 96% (correct predictions). Robustness analysis and feature importance analyzes confirm the approach’s reliability. These results demonstrate that state-of-the-art performance is attainable from a restricted diagnostic set, paving the way for minimalist yet resilient plasma control architectures for FPPs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

System-on-chip upgrade of millimeter-wave imaging diagnostics for fusion plasma

Monolithic, millimeter wave “system-on-chip” technology has been employed in chip heterodyne radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature and fluctuation diagnostics. The system employs 20 horn-waveguide receiver modules each with customized W-band (75–110 GHz) monolithic microwave integrated circuit chips comprising a W-band low noise amplifier, a balanced mixer, a ×2 local oscillator (LO) frequency doubler, and two intermediate frequency amplifier stages in each module. Compared to previous quasi-optical ECEI arrays with Schottky mixer diodes mounted on planar antennas, the upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature; an internal eight times multiplier chain is used to provide LO coupling, thereby eliminating the need for quasi-optical coupling. The horn-waveguide shielding housing avoids out-of-band noise interference on each module. The upgraded ECEI system plays an important role for absolute electron temperature and fluctuation measurements for edge and core region transport physics studies. An F-band receiver chip (up to 140 GHz) is under development for additional fusion facilities with a higher toroidal magnetic field. Visualization diagnostics provide multi-scale and multi-dimensional data in plasma profile evolution. Finally, a significant aspect of imaging measurement is focusing on artificial intelligence for science applications.

47 OTHER INSTRUMENTATION↗

Progress in ITER ECE diagnostic design and integration

The ITER electron cyclotron emission (ECE) diagnostic system has primary roles in providing measurements of the core electron temperature profile and the electron temperature fluctuation associated with the neoclassical tearing modes. The ITER ECE system includes a radial and oblique line-of-sight. Four 43-meter long low-loss transmission lines (TLs) are designed to transmit millimeter wave power in the frequency range of 70–1000 GHz in both X- and O-mode polarization from the port plug to the ECE instrumentation room in the diagnostic building. The measurement instrumentation includes two Fourier transform spectrometer (FTS) systems and two radiometer systems. The Indian Domestic Agency (IN-DA) and United States Domestic Agency share the responsibility. The IN-DA scope excluding instrumentation and control has passed its preliminary design review and is progressing towards the final design review (FDR). In parallel, the diagnostic integration in different areas is ongoing. Furthermore, several captive components for the TLs have passed FDR and will be manufactured for installation in the tokamak building soon. A peer review meeting has been held on the prototype hot calibration source, and its integration and new thermal analysis in the diagnostic shield module are continuing. A prototype TL is being tested. A prototype polarizing Martin-Puplett type FTS, operating in the frequency range 70–1000 GHz, features an in-vacuo fast scanning mechanism and a cryo-cooled dual-channel THz detector system. Its performance has been assessed in detail against ITER requirements.

47 OTHER INSTRUMENTATION↗

Laboratory observations of RF emission at plasma electron frequency and n + 1/2 times the electron cyclotron frequency in electron beam-plasma and beam-beam interactions

Electric field emissions at frequencies of (n + 1/2) times the electron cyclotron frequency have been generated in a large-scale electron beam experiment in a vacuum facility. These emissions arise when a contrastreaming beam configuration exists, the primary beam consisting of monoenergetic electrons (50 eV to 5 keV) and the other beam of lower-energy backscattered secondary electrons. It is suggested that the same mechanism could also be the source of the observed 3/2 times the electron cyclotron frequency emissions at auroral latitudes. In the absence of the beam-beam instability, weak oscillations were observed at the plasma frequency. In the latter case no significant modifications of the primary beam velocity distribution occurred, and the beam configuration is adequately described by single-particle motion in the ambient magnetic field.

Bernstein, W.↗

System-on-Chip approach microwave diagnostics development for burning plasma

System-on-chip (SoC) millimeter wave integrated circuit technology has been developed and employed in chip heterodyne radiometers in Electron Cyclotron Emission Imaging (ECEI) and Microwave Imaging Reflectometer (MIR) on the DIII-D tokamak for 2D electron temperature and density fluctuation diagnostics. The W-band (75-110 GHz) ECEI system has been employed with 20 poloidal horn receiver modules with customized monolithic integrated circuit chips and internal local oscillator coupling path. The new SoC approach demonstrates > 30 dB additional gain on the receiver and 95% electronics noise suppression compared to the previous Schottky diode mixer array . An F-band (110-140 GHz) receiver chip has been developed to measure MHD and turbulence behavior on the DIII-D high-field side, such as Alfven eigenmodes. Furthermore, it can image pedestal structure evolution on fusion facilities with stronger magnetic fields, such as ASDEX-U, EAST, HL-2M, and LHD. The F-band chip performance has been tested in the laboratory. Also, V-band (55-75 GHz) transmitter and receiver modules (55-75 GHz) have been developed for DIII-D and NSTX-U Furthermore, microwave Imaging Reflectometer (MIR) application suitability for 2D density fluctuation imaging on the pedestal region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation modeling and experimental validation of sub-cyclotron frequency microwave synchrotron radiation as a diagnostic tool for runaway electrons in present and future tokamaks

The microwave synchrotron radiation in the sub-cyclotron frequency region has been systematically validated as a diagnostic method for runaway electrons (>1 MeV) with radiation modeling and experiments on the DIII-D tokamak. Experimental observations reveal that sub-cyclotron frequency microwave radiation emerges only after runaway electrons are excited during plasma disruptions. Electron gyro-magnetic radiation modeling confirms that only runaway electrons with energies exceeding 1 MeV can emit radiation in the observed sub-cyclotron frequency band on DIII-D. The synchrotron Razin and Beaming effects are modeled in both the sub-cyclotron and standard Electron Cyclotron Emission (ECE) frequency region. Due to the pronounced beaming effect, the modeling supports that a standard ECE system is insensitive to synchrotron radiation from beamed runaway electrons (p ∥ >> p ⟂ ), but very sensitive to ECE radiation from isotropic suprathermal electrons (100 keV or less). DIII-D experiments further show that combining ECE and sub-cyclotron receivers reveals new insights into transient runaway dynamics during the plateau phase. Certain transient crash events appear only in the sub-cyclotron band or lead to opposite changes on the sub-cyclotron and standard ECE signals, supporting models where transient MHD events can exert a different effect on electrons of different energy levels. This novel diagnostic technique offers a powerful tool for studying and detecting runaway electron dynamics in both present-day and high-field future tokamaks. The diagnostic approach has been extrapolated to the SPARC tokamak, where sub-cyclotron radiation is predicted to respond sensitively and solely to runaway electrons during SPARC’s L-mode startup phase.

Yu, Guanying [Hefei Comprehensive National Science↗

Energetic electron transport in magnetic fields with island chains and stochastic regions

This paper investigates energetic electron transport in magnetized toroidal plasmas with magnetic fields characterized by island chains and regions of stochastic field lines produced by coil perturbations. We report on experiments performed in the DIII-D tokamak, which utilize electron cyclotron heating and current drive pulses to ‘tag’ electron populations within different locations across the discharge. The cross-field transport of these populations is then inferred from electron cyclotron emission measurements and gamma emission signals from scintillator detectors. Two types of energetic particles are distinguished and discussed: non-relativistic suprathermal electrons and relativistic runaway electrons. The magnetic field topology in each discharge is reconstructed with field-line tracing codes, which are also used to determine the location and scale of magnetic islands and stochastic regions. Comparison of simulations and experiments suggests that suprathermal transport is suppressed when the tagging is performed at a smaller radial location than the location of the $q = 1$ island chain and enhanced otherwise. Here q is the safety factor. We further demonstrate that increasing the width of the stochastic region within the edge plasma yields enhancement of the suprathermal electron transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dependence of the boundary heat flux width on core and edge profiles in Alcator C-Mod

This work presents new evidence that the heat flux width, λ q , in the Alcator C-Mod tokamak scales with the edge electron pressure, as observed in the ASDEX Upgrade (AUG) tokamak, but the scaling with volume-averaged pressure, $\bar{p}$, from the plasma stored energy, is a better predictor of λ q in Alcator C-Mod than the edge electron pressure. These previous studies, which find that λ q decreases with increasing plasma pressure, imply that a high performance core at high pressure will lead to challenging heat and particle exhaust due to very small λ q . This concern has led to our significant enlargement of the C-Mod database with the electron density, temperature, and pressure profile data from the Thomson scattering and electron cyclotron emission diagnostics. Using the C-Mod database augmented with new profile data, we find that λ q decreases with increasing edge electron pressure as ${\lambda }_{q}\propto {p}_{\mathrm{e},95}^{-0.26}$, similar to results from AUG, and showing the strength of cross-machine comparisons. We also find that ${\lambda }_{q}\propto {p}_{\mathrm{e},\mathrm{c}\mathrm{o}\mathrm{r}\mathrm{e}}^{-0.56}$, consistent with the original finding from C-Mod that the heat flux width scales as ${\bar{p}}^{-0.48}$. The scalings of λ q with separatrix pressure and gradient scale length are found to match the AUG results qualitatively. The C-Mod scalings with edge plasma quantities have more scatter than the $\bar{p}$ scaling, and, importantly, show different trends for H-modes relative to L- and I-mode. Furthermore, investigating the source of this discrepancy presents an opportunity for further study that may improve our ability to predict the heat flux width in different confinement scenarios in the pursuit of optimizing core-edge performance in future reactors.

Alcator C-Mod↗

Collisionless cooling of perpendicular electron temperature in the thermal quench of a magnetized plasma

Thermal quench of a nearly collisionless plasma against an isolated cooling boundary or region is an undesirable off-normal event in magnetic fusion experiments, but an ubiquitous process of cosmological importance in astrophysical plasmas. Parallel transport theory of ambipolar-constrained tail electron loss is known to predict rapid cooling of the parallel electron temperature $T_{e\Vert}$ although $T_{e\Vert}$ is difficult to diagnose in actual experiments. Instead direct experimental measurements can readily track the perpendicular electron temperature $T_{e\bot}$ via electron cyclotron emission. The physics underlying the observed fast drop in $T_{e\bot}$ requires a resolution. Here two collisionless mechanisms, dilutional cooling by infalling cold electrons and wave-particle interaction by two families of whistler instabilities, are shown to enable fast $T_{e\bot}$ cooling that closely tracks the mostly collisionless crash of $T_{e\Vert}$. These findings motivate both experimental validation and reexamination of a broad class of plasma cooling problems in laboratory, space, and astrophysical settings.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advances in physics and applications of 3D magnetic perturbations on the J-TEXT tokamak

In the last two years, three major technical improvements have been made on J-TEXT in supporting of the expanded operation regions and diagnostic capabilities. (1) The successful commission of the 105 GHz/500 kW/1 s electron cyclotron resonance heating (ECRH) system increasing the core electron temperature from 0.9 keV up to around 1.5 keV. (2) The poloidal divertor configuration with an X-point in the high-field side has been achieved. In particular, the 400 kW electron cyclotron wave has also been successfully injected into the diverted plasma. (3) A 256-channel electron cyclotron emission imaging diagnostic system and two sets of four-channel Doppler backscattering diagnostics have been successfully developed on J-TEXT, allowing detailed measurement of the electron temperature and density fluctuations for turbulence and MHD research. The locked mode (LM), especially the 2/1 LM, is one of the biggest threats to the plasma operation. Both the thresholds of 2/1 and 3/1 LM are observed to vary non-monotonically on electron density. The electrode biasing was applied successfully to unlock the LM from either a rotating or static resonant magnetic perturbation (RMP) field. In the presence of 2/1 LM, three kinds of standing wave (SW) structures have been observed to share a similar connection to the island structure, i.e. the nodes of the SWs locate around the O- or X-points of the 2/1 island. The control and mitigation of disruption is essential to the safe operation of ITER, and it has been systematically studied by applying a RMP field, massive gas injection (MGI) and shattered pellet injection on J-TEXT. When the RMP-induced 2/1 LM is larger than a critical width, the MGI shutdown process can be significantly influenced. If the phase difference between the O-point of LM and the MGI valve is +90° (or –90°), the penetration depth and the assimilation of impurities can be enhanced (or suppressed) during the pre-thermal quench (TQ) phase and result in a faster (or slower) TQ. A secondary MGI can also suppress the runaway electron (RE) generation, if the additional high-Z impurity gas arrives at the plasma edge before TQ. When the secondary MGI has been applied after the formation of the RE current plateau, the RE current can be dissipated, and the dissipation rate increases with the injected impurity quantity but saturates with a maximum of 28 MA s –1 . The non-local transport is experimentally observed in the ion transport channel. The electron thermal diffusivity significantly increases with the ECRH power. Theoretical work shows that significant intrinsic current can be driven by electromagnetic turbulence, and the robust formation mechanism of the E × B staircase is identified from the Hasegawa–Wakatani system.

divertor↗

A novel method for thermal noise reduction, enabling measurements of broadband, low-amplitude electron temperature fluctuations using individual radiometer channels

A new analysis method has been developed for measurements of broadband, low-amplitude turbulent electron temperature fluctuations in fusion plasmas using individual radiometer channels of a correlation electron cyclotron emission diagnostic. This method takes advantage of differences in the correlation time of thermal noise compared to the correlation time of plasma fluctuations in fusion reactors. The validation of this single-channel method is demonstrated using comparisons with the standard dual-channel radiometer spectral decorrelation method for measurements of turbulent electron temperature fluctuations in the core and edge of low confinement (L), improved confinement (I), and high confinement (H)-mode plasmas at the ASDEX Upgrade tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics for Burning Plasmas

Here, recent progress in the design and manufacturing development of in-vessel diagnostic components by the U.S. ITER team is reported. Design and manufacturing choices are driven by engineering challenges stemming from ITER’s burning plasma mission, which entails levels of plasma neutron emission, pulse lengths, and size scales well beyond the existing database. Challenges include port access limitations, neutron irradiation and activation risks, nuclear heating of components, complex interfaces, remote handling compatibility, and constraints on component and processing materials. Responses to these challenges are presented using examples from the low field side reflectometer, toroidal interferometer polarimeter, and electron cyclotron emission diagnostics. Relevance of the experience from ITER diagnostics engineering to the design of future integrated fusion facilities based on burning plasmas is addressed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stability of beta-induced Alfvén eigenmodes (BAE) in DIII-D

Although the stability of ellipticity, toroidal and reversed-shear Alfvén eigenmodes (EAE, TAE, RSAE) are relatively well understood, less is known about the stability of lower-frequency modes such as the beta-induced Alfvén eigenmode (BAE) but, because they are often unstable in present devices and are implicated in fast-ion transport, understanding their stability is vital. BAE stability is studied in primarily weak or reversed shear DIII-D plasmas with sub-Alfvénic deuterium beams. Modes are classified based on electron cyclotron emission, beam emission spectroscopy, magnetics, and interferometer data. The study is limited to the initial two seconds of the discharge, where the evolving q profile provides an effective scan of the dependence of stability upon q. In a dedicated experiment, BAEs are unstable at times in the discharge when the minimum of the safety factor q min is close to a rational number. The observed mode frequencies are usually close to analytic estimates of the BAE accumulation point and the eigenfunction peaks in the vicinity of q min . Unstable BAEs usually occur in bursts that chirp rapidly in frequency. To isolate the importance of thermal and beam gradients in driving the modes, the beam and electron cyclotron heating power is altered for 50–100 ms durations in reproducible discharges. As expected from the resonance condition, BAEs depend sensitively on the beam power and injection geometry. Modes only persist for ~25 ms because the anisotropic beam population only interacts strongly with the modes over a relatively narrow range of q. Lastly, a database of over 1000 beam-heated discharges shows that BAEs are more likely to be unstable when the poloidal beta exceeds 0.5.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗