Engineering PapersSearch

SEARCH · Engineering Papers

Results for “electron counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Laser velocimeter measurement of developing and periodic flows

The transmitting-receiving lens system of a two-component backscatter laser-velocimeter optical package currently in operation is discussed. It is basically a Galilean-type telescope which provides for spatial translation of the focal volume along the optical axis, but it also has certain optical constraints which are discussed. This scanning feature of the unit has been used with spectrum analyzer processing for the measurement of (1) trailing vortices in a wind tunnel and (2) a developing (decaying) vortex that was generated by towing a wing model through a water towing tank. The optical system has also been interfaced with period counting electronics and has been applied to the periodic flow generated by a model helicopter rotor. Results are presented and the techniques of data acquisition and the 'strobing' of the processor are discussed.

Orloff, K. L.

Quadrant anode image sensor

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, about 10 microns, allows individual MCP channels to be distinguished.

Lampton, M.

Obtaining an electrical output from a mechanical flowmeter

Circuit using optical sensor, low power counting electronics, oneclip digital-to-analog converter and operational amplifier converts mechanical readout of water, gas, fuel-oil or power meter to analog signal suitable for online processings.

Powers, W. T.

The application of laser Rayleigh scattering to gas density measurements in hypersonic helium flows

Measurements of the mean static free-stream gas density have been made in two Langley Research Center helium facilities, the 3-inch leg of the high-Reynolds-number helium complex and the 22-inch hypersonic helium tunnel. Rayleigh scattering of a CW argon ion laser beam at 514.5 nm provided the basic physical mechanism. The behavior of the scattered signal was linear, confirmed by a preliminary laboratory study. That study also revealed the need to introduce baffles to reduce stray light. A relatively simple optical system and associated photon-counting electronics were utilized to obtain data for densities from 10 to the 23rd to 10 to the 25th per cu m. The major purpose, to confirm the applicability of this technique in the hypersonic helium flow, was accomplished.

Hoppe, J. C.

High-voltage spark carbon-fiber sticky-tape data analyzer

An efficient method for detecting carbon fibers collected on a stick tape monitor was developed. The fibers were released from a simulated crash fire situation containing carbon fiber composite material. The method utilized the ability of the fiber to initiate a spark across a set of alternately biased high voltage electrodes to electronically count the number of fiber fragments collected on the tape. It was found that the spark, which contains high energy and is of very short duration, is capable of partially damaging or consuming the fiber fragments. It also creates a mechanical disturbance which ejects the fiber from the grid. Both characteristics were helpful in establishing a single discharge pulse for each fiber segment.

Yang, L. C.

Particle acceleration due to shocks in the interplanetary field: High time resolution data and simulation results

Data were examined from two experiments aboard the Explorer 50 (IMP 8) spacecraft. The Johns Hopkins University/Applied Lab Charged Particle Measurement Experiment (CPME) provides 10.12 second resolution ion and electron count rates as well as 5.5 minute or longer averages of the same, with data sampled in the ecliptic plane. The high time resolution of the data allows for an explicit, point by point, merging of the magnetic field and particle data and thus a close examination of the pre- and post-shock conditions and particle fluxes associated with large angle oblique shocks in the interplanetary field. A computer simulation has been developed wherein sample particle trajectories, taken from observed fluxes, are allowed to interact with a planar shock either forward or backward in time. One event, the 1974 Day 312 shock, is examined in detail.

Kessel, R. L.

Astronomical research at the Hopkins Phoenix Observatory

After trying astrophotography and radio astronomy it was decided that the best way to do meaningful astronomical research at a small private observatory was by doing photoelectric photometry. Having the observatory located in the back yard of a private residence affors the luxury of observing any time the sky conditions permit. Also modest equipment is all that is needed to do accurate UBV photometry of stars 8th magnitude and brighter. Since beginning in 1980 the Hopkins Phoenix Observatory has published papers on several RS CVn star systems, 31 Cygni, 22 Vul, 18 Tau Per, and has followed the 1982-1984 eclipse of Epsilon Aurigae from its start to the present with over 1000 UBV measurements. In addition the Hopkins Phoenix Observatory has developed several pieces of photometry equipment including the HPO PEPH-101 photometer head and photon counting electronics.

Hopkins, J. L.

Relationships among the harmonic coefficients of scan plane anisotropies

Frequently, a detector on a spinning spacecraft measures the flux of charged particles whose velocities lie in a plane containing the magnetic field. This flux may be Fourier analyzed as a function of the spacecraft roll angle. Relationships among the Fourier coefficients are derived using the adiabatic solution of the Vlasov equation. These relationships depend only on the fact that the lowest order (in gyroradius) of the distribution function is a function of the magnetic moment and that the first-order term is a function of the lowest order. These relationships may be used to separate the proton from the electron counts registered in Saturn's inner magnetosphere by the University of California's Cerenkov counter on Pioneer 11.

Northrop, T. G.

A new self-calibration method applied to TOMS and SBUV backscattered ultraviolet data to determine long-term global ozone change

The currently archived (1989) total ozone mapping spectrometer (TOMS) and solar backscattered ultraviolet (SBUV) total ozone data (version 5) show a global average decrease of about 9.0 percent from November 1978 to November 1988. This large decrease disagrees with an approximate 3.5-percent decrease estimated from the ground-based Dobson network. The primary source of disagreement was found to arise from an overestimate of reflectivity change and its incorrect wavelengths dependence for the diffuse plate used when measuring solar irradiance. Both of these factors have led to an overestimate of the rate of atmospheric ozone depletion by SBUV and TOMS. For total ozone measured by TOMS, a means has been found to use the measured radiance-irradiance ratio from several wavelengths pairs to construct an internally self-consistent calibration. The method uses the wavelength dependence of the sensitivity to calibration errors and the requirement that albedo ratios for each wavelength pair yield the same total ozone amounts. Smaller errors in determining spacecraft attitude, synchronization problems with the photon counting electronics, and sea-glint contamination of boundary reflectivity data have been corrected or minimized. New climatological low-ozone profiles have been incorporated into the TOMS algorithm that are appropriate for Antarctic ozone hole conditions and other low ozone cases. The combined corrections have led to a new determination of the global average total ozone trend (version 6) as a 2.9 + or - 1.3 percent decrease over 11 years (October 1978 to November 1989).

Herman, J. R.

ARCLITE: the Arctic Lidar Technology Facility at Sondre Stromfjord, Greenland

SRI International is presently developing an Arctic lidar (ARCLITE) facility at the incoherent-scatter radar site in Sondre Stromfjord, Greenland (67.0 degrees N, 209.2 degrees W). The project, funded by NSF through the CEDAR (Coupling Energetics and Dynamics of Atmospheric Regions) initiative, is to perform high-altitude molecular/aerosol backscatter measurements in the Arctic covering the stratosphere/mesosphere region during nighttime and daytime conditions. The lidar system employs an injection seeded, high-energy GCR-5 Spectra Physics Nd:YAG laser for primary operation at 532 nm (550 mJ per pulse at 30 Hz). The receiver system is designed around a 36-inch Cassegrainian telescope of astronomical quality with receiver components and photon-counting electronics for day and night operations. The Rayleigh backscatter measurements will conduct investigations concerning long-term studies of the basic density and temperature structure of the Arctic stratosphere/mesosphere region; effects of stratospheric warming on the structure of the stratosphere/mesosphere region; occurrence and properties of polar stratospheric clouds; occurrence of noctilucent clouds and their properties at high latitudes; and dynamic and thermodynamic coupling between the stratosphere/mesosphere region and the lower thermosphere.

Thayer, J. P.

Rayleigh-Brillouin scattering for high-pressure gas temperature measurements

An experiment was set up to evaluate the feasibility of using Rayleigh-Brillouin scattering as a diagnostic technique for measuring gas temperature in high pressure environments, such as the Space Shuttle Main Engine (SSME) Preburner. A high pressure furnace is used as the scattering chamber. Either nitrogen or hydrogen may be used. An argon ion laser beam is focused into the furnace. Light backscattering from the gas in the furnace is collected and analyzed with a 5-pass scanning Fabry-Perot interferometer and photon counting electronics. The multi-pass configuration provides the high frequency selectively needed to measure the Brillouin peaks in the presence of large amounts of spuriously scattered light at the laser frequency. Preliminary measurements were made at room temperature in nitrogen at pressures up to 2000 psia. The free spectral range of the interferometer and frequency separation of the Brillouin peaks are determined from measured spectra. Temperature measurements are then obtained using the simple continuum theory with low frequency values of specific heat ratio and shear viscosity. The measured temperatures are within 10 percent of the true value.

Seasholtz, Richard G.

Energy Calibration of the Scintillating Optical Fiber Calorimeter Chamber (SOFCAL)

The Scintillating Optical Fiber Calorimeter (SOFCAL) detector is designed to make direct measures of the primary cosmic ray spectrum from -200 GeV/amu - 20 TeV/amu. The primary particles are resolved into groups according to their charge (p, He, CNO, Medium Z, Heavy Z) using both active and passive components integrated into the detector. The principal part of SOFCAL is a thin ionization calorimeter that measures the electromagnetic cascades that result from these energetic particles interacting in the detector. The calorimeter is divided into two sections: a thin passive emulsion/x-ray film calorimeter, and a fiber calorimeter that uses crossing layers of small scintillating optical fibers to sample the energy deposition of the cascades. The energy determination is made by fitting the fiber data to transition curves generated by Monte Carlo simulations. The fiber data must first be calibrated using the electron counts from the emulsion plates in the calorimeter for a small number of events. The technique and results of this calibration will be presented together with samples of the data from a balloon flight.

Christl, M. C.

Investigation of Density Fluctuations in Supersonic Free Jets and Correlation with Generated Noise

The air density fluctuations in the plumes of fully-expanded, unheated free jets were investigated experimentally using a Rayleigh scattering based technique. The point measuring technique used a continuous wave laser, fiber-optic transmission and photon counting electronics. The radial and centerline profiles of time-averaged density and root-mean-square density fluctuation provided a comparative description of jet growth. To measure density fluctuation spectra a two-Photomultiplier tube technique was used. Crosscorrelation between the two PMT signals significantly reduced electronic shot noise contribution. Turbulent density fluctuations occurring up to a Strouhal number (Sr) of 2.5 were resolved. A remarkable feature of density spectra, obtained from the same locations of jets in 0.5< M<1.5 range, is a constant Strouhal frequency for peak fluctuations. A detailed survey at Mach numbers M = 0.95, 1.4 and 1.8 showed that, in general, distribution of various Strouhal frequency fluctuations remained similar for the three jets. In spite of the similarity in the flow fluctuation the noise characteristics were found to be significantly different. Spark schlieren photographs and near field microphone measurements confirmed that the eddy Mach wave radiation was present in Mach 1.8 jet, and was absent in Mach 0.95 jet. To measure correlation between the flow and the far field sound pressure fluctuations, a microphone was kept at a distance of 50 diameters, 30 deg. to the flow direction, and the laser probe volume was moved from point to point in the flow. The density fluctuations in the peripheral shear layer of Mach 1.8 jet showed significant correlation up to the measurement limit of Sr = 2.5, while for Mach 0.95 jet no correlation was measured. Along the centerline measurable correlation was found from the end of the potential core and at the low frequency range (Sr less than 0.5). Usually the normalized correlation values increased with an increase of the jet Mach number. The experimental data point out eddy Mach waves as a strong source of sound generation in supersonic jets and fail to locate the primary noise mechanism in subsonic jets.

Panda, J.

Beagle 2: The Next Exobiology Mission to Mars

Beagle 2 is a 60 kg probe (with a 30 kg lander) developed in the United Kingdom for inclusion on the European Space Agency's 2003 Mars Express. Beagle 2 will deliver to the Martian surface a payload which consists of a high percentage of science instruments to landed spacecraft mass. Beagle 2 will be launched in June, 2003 with Mars Express on a Soyuz-Fregat rocket from the Baikonur Cosmodrome in Kazakhstan. Beagle 2 will land on Mars on December 26, 2003 in the Isidis Planitia basin (approximately 10 degrees N and 275 degrees W), a large sedimentary basin that overlies the boundary between ancient highlands and northern plains. Isidis Planitia, the third largest basin on Mars, which is possibly filled with sediment deposited at the bottom of long-standing lakes or seas, offers an ideal environment for preserving traces of life. Beagle 2 was developed to search for organic material and other volatiles on and below the surface of Mars in addition to the study of the inorganic chemistry and mineralogy. Beagle 2 will utilize a mechanical mole and grinder to obtain samples from below the surface, under rocks and inside rocks. A pair of stereo cameras will image the landing site along with a microscope for examination of surface and rock samples. Analyses will include both rock and soil samples at various wavelengths, X-ray spectrometer and Mossbauer spectrometer as well as a search for organics and other light element species (e.g. carbonates and water) and measurement of their isotopic compositions. Beagle 2 has as its focus the goal of establishing whether evidence for life existed in the past on Mars at the Isidis Planitia site or at least establishing if the conditions were ever suitable. Carbonates and organic components were first recognized as existing on Mars when they were found in the Martian meteorite Nakhla. Romanek et al showed the carbonates in ALH84001 were formed at low temperatures. McKay et al noted possible evidence of early life on Mars within the ALH84001 meteorite. Thomas-Keprta et al showed the magnetite biomarkers in ALH84001's carbonates are indistinguishable from those formed by magnetotactic bacteria found on Earth. Gibson et al showed there was significant evidence for liquid water and biogenic products present on Mars across a 3.9 billion year period. A mechanical arm (PAW) operates from the lander and is used for science operations along with sample acquisition. Instruments attached to the PAW include: stereo cameras, Mossbauer instrument, X-ray fluorescence instrument, microscope, environmental sensors, rock corer/grinder, a spoon, mirror, brushes, a mole attachment for acquisition of subsurface to depths of 1 to 2 meters and an illumination device. Each camera has 14 filters which have been optimized for mineralogy composition, dust and water vapor detection. The microscope's camera is designed for viewing the size and shape of dust particles, rock surfaces, microfossils, and characteristics of the samples prior to introduction into the gas analysis package (GAP). The camera has a resolution of 4 microns/pixel, features four color capability (red, green, blue and UV (ultraviolet) fluoresence), a depth of focus of 40 micrometers and translation stage of +3 millimeters. The heart of the Beagle 2's life detection package is the gas analysis package (GAP), which consists of a mass spectrometer with collectors at fixed masses for precise isotopic ratio measurements and voltage scanning for spectral analysis. Primary aim of the GAP is to search for the presence of bulk constituents, individual species, and isotopic fractionations for both extinct and extent life along with studying the low-temperature geochemistry of the hydrogen, carbon, nitrogen and oxygen components on Mars from both the surface and atmosphere. GAP is a magnetic sector mass spectrometer with the range of 1 to 140 amu which can be operated in both the static and dynamic modes. A triple Faraday collector array will be used for C, N and O ratios along with a double Faraday array for H/D. Pulse counting electron multiplier will be utilized for noble gases and selected organics. Anticipated detection limits are at the picomole level for operation in the static mode of operation and high precision isotopic measurements will be made in the dynamic mode. Sample processing and preparation system consists of reaction vessels along with references. Sample ovens capable of being heated are attached to the manifold for sample combustion. Surface, subsurface materials and interior rock specimens will be combusted in pure oxygen gas at various temperature intervals to release organic matter and volatiles. Combustion process will permit detection of all forms and all atoms of carbon present in the samples. A chemical processing system is capable of a variety of conversion reactions. Gases are manipulated either by cryogenic or chemical reactions and passed through the gas handling portion of the vacuum system. There are two modes of operation: quantitative analysis and precise isotopic measurements. Additional information is contained in the original extended abstract.

Gibson, Everett K., Jr.

Setting up a Rayleigh Scattering Based Flow Measuring System in a Large Nozzle Testing Facility

A molecular Rayleigh scattering based air density measurement system has been built in a large nozzle testing facility at NASA Glenn Research Center. The technique depends on the light scattering by gas molecules present in air; no artificial seeding is required. Light from a single mode, continuous wave laser was transmitted to the nozzle facility by optical fiber, and light scattered by gas molecules, at various points along the laser beam, is collected and measured by photon-counting electronics. By placing the laser beam and collection optics on synchronized traversing units, the point measurement technique is made effective for surveying density variation over a cross-section of the nozzle plume. Various difficulties associated with dust particles, stray light, high noise level and vibration are discussed. Finally, a limited amount of data from an underexpanded jet are presented and compared with expected variations to validate the technique.

Panda, Jayanta

Velocity and Temperature Measurement in Supersonic Free Jets Using Spectrally Resolved Rayleigh Scattering

The flow fields of unheated, supersonic free jets from convergent and convergent-divergent nozzles operating at M = 0.99, 1.4, and 1.6 were measured using spectrally resolved Rayleigh scattering technique. The axial component of velocity and temperature data as well as density data obtained from a previous experiment are presented in a systematic way with the goal of producing a database useful for validating computational fluid dynamics codes. The Rayleigh scattering process from air molecules provides a fundamental means of measuring flow properties in a non-intrusive, particle free manner. In the spectrally resolved application, laser light scattered by the air molecules is collected and analyzed using a Fabry-Perot interferometer (FPI). The difference between the incident laser frequency and the peak of the Rayleigh spectrum provides a measure of gas velocity. The temperature is measured from the spectral broadening caused by the random thermal motion and density is measured from the total light intensity. The present point measurement technique uses a CW laser, a scanning FPI and photon counting electronics. The 1 mm long probe volume is moved from point to point to survey the flow fields. Additional arrangements were made to remove particles from the main as well as the entrained flow and to isolate FPI from the high sound and vibration levels produced by the supersonic jets. In general, velocity is measured within +/- 10 m/s accuracy and temperature within +/- 10 K accuracy.

Panda, J.

Further Progress in Noise Source Identification in High Speed Jets via Causality Principle

To locate noise sources in high-speed jets, the sound pressure fluctuations p/, measured at far field locations, were correlated with each of density p, axial velocity u, radial velocity v, puu and pvv fluctuations measured from various points in fully expanded, unheated plumes of Mach number 0.95, 1.4 and 1.8. The velocity and density fluctuations were measured simultaneously using a recently developed, non-intrusive, point measurement technique based on molecular Rayleigh scattering (Seasholtz, Panda, and Elam, AIAA Paper 2002-0827). The technique uses a continuous wave, narrow line-width laser, Fabry-Perot interferometer and photon counting electronics. The far field sound pressure fluctuations at 30 to the jet axis provided the highest correlation coefficients with all flow variables. The correlation coefficients decreased sharply with increased microphone polar angle, and beyond about 60 all correlation mostly fell below the experimental noise floor. Among all correlations < puu; p/> showed the highest values. Interestingly, , in all respects, were very similar to . The and correlations with 90deg microphone fell below the noise floor. By moving the laser probe at various locations in the jet it was found that the strongest noise source lies downstream of the end of the potential core and extends many diameters beyond. Correlation measurement from the lip shear layer showed a Mach number dependency. While significant correlations were measured in Mach 1.8 jet, values were mostly below the noise floor for subsonic Mach 0.95 jet. Various additional analyses showed that fluctuations from large organized structures mostly contributed to the measured correlation, while that from small scale structures fell below the noise floor.

Panda, J.

Optimum Receiver Structure for PPM Signals with Avalanche Photodiode Statistics

The maximum likelihood decision statistic for detection of pulse-position modulated signals with an avalanche photodiode is derived, using the more accurate Webb density rather than Poisson or Gaussian approximations for the distribution of avalanche photodiode output electrons. It is shown that for Webb-distributed output electtrons, the maximum likelihood rule is to choose the PPM word corresponding to the slot with the maximum electron count.

avalanche photodiode PPM Gaussian Poisson