Engineering PapersSearch

SEARCH · Engineering Papers

Results for “electron beam sensitive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Fabrication of Tunnel Junctions For Direct Detector Arrays With Single-Electron Transistor Readout Using Electron-Beam Lithography

This paper will describe the fabrication of small aluminum tunnel junctions for applications in astronomy. Antenna-coupled superconducting tunnel junctions with integrated single-electron transistor readout have the potential for photon-counting sensitivity at sub-millimeter wavelengths. The junctions for the detector and single-electron transistor can be made with electron-beam lithography and a standard self-aligned double-angle deposition process. However, high yield and uniformity of the junctions is required for large-format detector arrays. This paper will describe how measurement and modification of the sensitivity ratio in the resist bilayer was used to greatly improve the reliability of forming devices with uniform, sub-micron size, low-leakage junctions.

Stevenson, T. R.

Extreme Ultraviolet and Beyond Extreme Ultraviolet Lithography Using Amorphous Zeolitic Imidazolate Resists Deposited by Atomic/Molecular Layer Deposition

Amorphous zinc-imidazolate (aZnMIm) resists show potential to meet the demands for next-generation high-numerical aperture (high-NA) metal-containing extreme ultraviolet (EUV) resist materials, given their ease of deposition by atomic/molecular layer deposition (ALD/MLD) at thicknesses of 20 nm and below. Here, this study demonstrates that aZnMIm thin films, previously identified as high-resolution electron beam resists, can also function as negative-tone EUV photoresists. Water development achieves high sensitivity (5 mJ/cm 2 ) but leaves significant residue, while acetic acid development results in poor contrast. A hybrid approach─water followed by acetic acid─enables residue-free development with a sensitivity of 181 mJ/cm 2 . Dry development using 1,1,1,5,5,5-hexafluoroacetylacetone (hfacH) is also possible but shows lower sensitivity (375 mJ/cm 2 ) compared to wet development methods. EUV photoelectron spectroscopy (PES), reflectometry/EUV absorption, total electron yield (TEY), residual gas analysis (RGA), and time-of-flight secondary ion mass spectrometry (TOF-SIMS) were used to investigate the effects of EUV irradiation on aZnMIm resists. Reflectometry experiments reveal an aZnMIm EUV absorption coefficient of 6.2 μm –1 , while PES and TEY analyses show that, compared to poly(4-hydroxystyrene) (PHS), a polymer-based reference resist, aZnMIm emits more primary and secondary electrons but generates fewer slow electrons relative to its primary electron emission; its total electron yield is similar to that of poly(methyl methacrylate) (PMMA) resists. When exposed to EUV, aZnMIm predominantly outgasses H 2 , as determined by RGA. TOF-SIMS measurements demonstrate that high-dose EUV exposure only partially fragments the 2-methylimidazole (2MIm) organic linkers, unlike high-dose electron beam exposure, which is known to completely degrade them. Additionally, aZnMIm resists show promise for potential beyond EUV lithography (BEUVL) due to the presence of Zn, which provides higher sensitivity at a wavelength of 6.7 nm compared to other metal ions, such as Sn, that are currently used in the best-performing EUV metal–organic resists. TEY measurements demonstrate that aZnMIm emits nearly twice as many electrons as PHS at 6.7 nm. The BEUV TEY of aZnMIm also surpasses that of PMMA, poly(pentafluorostyrene), and poly(4-iodostyrene), with the latter two being known for their high EUV TEYs. This work provides insight into zeolitic imidazolate framework (ZIF)-based EUV and BEUV resists and highlights their potential for both wet and dry development.

lithography

Mapping Electron Beam-Induced Radiolytic Damage in Molecular Crystals

Every electron crystallography experiment is fundamentally constrained by radiation damage [1]. Despite its crucial importance, little is understood about the onset and progression of radiolysis in beam-sensitive molecular crystals [2]. Since the typical metric used for monitoring the degradation induced by radiolysis is the attenuation of Bragg reflections in electron diffraction patterns [3], the scope of previous analyses [2-6] has mostly been limited to indirect observation via the back focal plane. Here, a simultaneous visualization of the effects of electron beam-induced radiolysis—in both real space and reciprocal space—remains elusive.

74 ATOMIC AND MOLECULAR PHYSICS

PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF TUNNEL

Non-evaporable getter (NEG) pumps are being used to maintain ultra-high vacuum in the beamline of superconducting radio-frequency (SRF) accelerators, such as the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Because of the sensitivity of the performance of SRF cavities to particulate contamination, it is important to evaluate the integrity of the NEG material after exposure to high radiation during beam operation. The particulate from two NEG pumps based on ZAO® getter alloy was measured with a particle counter in a clean-room. The pumps were assembled onto a hermetically sealed setup which was placed in the CEBAF tunnel. The setup was exposed to 24 h beam operation for ~ 230 days. The total gamma-rays dose measured on the test setup was ~ 1.6 Mrad. The total neutron dose measured at ~ 75 cm of the test setup was ~ 11 krad. The particulate count from the two pumps was measured again in the clean-room after irradiation. Whereas an increase of particulate counts was measured, compared to before irradiation, subsequent measurements indicate the absence of systematically loose particulate. The pumping speed of one of the irradiated pumps was also measured to be consistent with that of a non-irradiated one, corroborating the absence of significant damage to the ZAO® NEG material due to irradiation.

Ciovati, G. [Thomas Jefferson National Accelerator

PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF TUNNEL

Non-evaporable getter (NEG) pumps are being used to maintain ultra-high vacuum in the beamline of superconducting radio-frequency (SRF) accelerators, such as the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Because of the sensitivity of the performance of SRF cavities to particulate contamination, it is important to evaluate the integrity of the NEG material after exposure to high radiation during beam operation. The particulate from two NEG pumps based on ZAO® getter alloy was measured with a particle counter in a clean-room. The pumps were assembled onto a hermetically sealed setup which was placed in the CEBAF tunnel. The setup was exposed to 24 h beam operation for ~ 230 days. The total gamma-rays dose measured on the test setup was ~ 1.6 Mrad. The total neutron dose measured at ~ 75 cm of the test setup was ~ 11 krad. The particulate count from the two pumps was measured again in the clean-room after irradiation. Whereas an increase of particulate counts was measured, compared to before irradiation, subsequent measurements indicate the absence of systematically loose particulate. The pumping speed of one of the irradiated pumps was also measured to be consistent with that of a non-irradiated one, corroborating the absence of significant damage to the ZAO® NEG material due to irradiation.

Ciovati, Gianluigi [Thomas Jefferson National Acce

NOvA in 10 Minutes

NOvA is a long-baseline neutrino oscillation experiment that utilizes the NuMI beamline at Fermilab. The experiment consists of two functionally identical, segmented liquid scintillator detectors. A 300-ton near detector sits at Fermilab, while a 14-kiloton far detector is located 810 km away in Ash River, Minnesota. Both are situated 14.6 mrad off the beam axis to peak the neutrino energy spectrum near the first oscillation maximum. NOvA measures muon neutrino disappearance and electron neutrino appearance in both neutrino and antineutrino beam modes, providing sensitivity to the neutrino mass ordering, the octant of the atmospheric mixing angle \theta_{23}, and the CP-violating phase \delta_{CP}. In this talk, I will give a concise overview of the NOvA experiment and its detectors, followed by highlights from recent oscillation analyses. I will also highlight notable cross-section measurements at the near detector. Finally, I will briefly introduce ongoing analyses beyond the standard three-flavor oscillation framework, including searches for sterile neutrinos and non-standard interactions, as well as exotic signatures such as magnetic monopoles, light dark matter, neutrino magnetic moments, and cosmic-ray muon studies.

Khanam, Aklima [Syracuse U. (main)] (ORCID:0009000

Welding of Crack Sensitive Aluminum Alloys for Liquid Rocket Propulsion Applications

In this welding test campaign, electron beam welding (EBW) and manual gas tungsten arc welding (GTAW) processes were utilized to join an additively manufactured aluminum alloy nozzle to a wrought aluminum flange. Both aluminum alloys were 6061, which in their conventional form are susceptible to solidification cracking issues. The AM nozzle utilized a novel high-performance modified version of 6061 which exhibits crack resistant properties during the AM process and during welding. When manually conducting GTAWs a filler wire with the same modified version of 6061 was utilized to weld different combinations of 6061 coupons (either modified or unmodified). Due to the grain refinement technology in the modified 6061, either as filler material or base material, there was complete elimination of weld solidification cracking. During EBW development a combination of wrought 6061 with a modified and additively manufactured 6061 was investigated. The EBWs developed exhibited no crack like defects. Each weld development program utilized non-destructive evaluation, metallography, and mechanical testing to determine the final weld acceptance. Mechanical testing involved hardness evaluation and tension testing on welded coupons. Both welding techniques were successfully developed and exhibited adequate properties for the final test articles and met all requirements of the development campaign. These welds were ultimately developed to be utilized on a set of all-aluminum liquid rocket nozzles to demonstrate additively manufactured aluminum alloys for propulsion applications. These aluminum nozzles were tested at NASA Marshall Space Flight Center’s hot fire test facility and subsequently underwent a test campaign involving a variety of chamber pressures and liquid propellant combinations. Following the hot fire test campaign each weldment was investigated for post operation performance and any defects that may have evolved during testing.

Welding

Initial results of SEPAC scientific achievement

Electron beam injection of 5 keV, 300 mA (1.5 kW) and MPD arcjet plasma injection of 2 kJ/shot were successfully performed together with various kinds of diagnostic instruments including a high sensitivity TV camera observation in the Spacelab 1. Major scientific results obtained are studies of: (1) vehicle charge-up due to the electron beam emission and its neutralization by the MPD arcjet plasma; (2) beam-plasma interaction including the plasma wave excitation; (3) beam-atmosphere interaction such as the verification of critical velocity ionization effect; and (4) anomalous enhancement of ionization associated with a neutral gas injection into space.

Obayashi, T.

An f/35 submillimeter photometer for the NASA infrared telescope facility

The design and performance of an f/35 submillimeter photometer are discussed. It is noted that the instrument provides for both broad- and medium-width passbands between 350 microns and 2 mm and for beam sizes between 28 arcsec and 100 arcsec FWHM. Under good atmospheric conditions, a broad-band 400 micron sensitivity of approximately 1.5 Jy is found to be obtainable in one hour. A description is given of the photometer's support housing, submillimeter radiometer, and electronics and data-handling system. In evaluating the performance, attention is given to sensitivity, beam profiles, and the effect of changes in the aperture on the signal.

Whitcomb, S. E.

Development of a Robust, High Current, Low Power Field Emission Electron Gun for a Spaceflight Reflectron Time-of-Flight Mass Spectrometer

Carbon materials, including carbon nanotubes (CNTs) and nitrogen-incorporated ultrananocrystalline diamond (N-UNCD), have been of considerable interest for field emission applications for over a decade. In particular, robust field emission materials are compelling for space applications due to the low power consumption and potential for miniaturization. A reflectron time-of-flight mass spectrometer (TOF-MS) under development for in situ measurements on the Moon and other Solar System bodies uses a field emitter to generate ions from gaseous samples, using electron ionization. For these unusual environments, robustness, reliability, and long life are of paramount importance, and to this end, we have explored the field emission properties and lifetime of carbon nanotubes and nitrogen-incorporated ultrananocrystalline diamond (N-UNCD) thin films, the latter developed and patented by Argonne National Laboratory. We will present recent investigations of N-UNCD as a robust field emitter, revealing that this material offers stable performance in high vacuum for up to 1000 hours with threshold voltage for emission of about 3-4 V/lJm and current densities in the range of tens of microA. Optimizing the mass resolution and sensitivity of such a mass spectrometer has also been enabled by a parallel effort to scale up a CNT emitter to an array measuring 2 mm x 40 mm. Through simulation and experiment of the new extended format emitter, we have determined that focusing the electron beam is limited due to the angular spread of the emitted electrons. This dispersion effect can be reduced through modification of the electron gun geometry, but this reduces the current reaching the ionization region. By increasing the transmission efficiency of the electron beam to the anode, we have increased the anode current by two orders of magnitude to realize a corresponding enhancement in instrument sensitivity, at a moderate cost to mass resolution. We will report recent experimental and modeling results to describe the performance of a field emission electron gun as employed in the Volatile Analysis by Pyrolysis of Regolith (VAPoR) TOF-MS prototype.

Southard, Adrian E.

Dark photons and axion-like particles at the electron-ion collider in China

The Electron-Ion Collider in China (EicC), a proposed high-luminosity facility with advanced charged particle and photon detection capabilities, provides unique opportunities to uncover new physics beyond the Standard Model. We analyze its sensitivity to dark photons produced through electron bremsstrahlung in coherent scattering. Thanks to its beam energy settings, it has the potential to comprehensively probe the previously unexplored parameter space between the constraints from meson decays and beam dumps below $\mathcal{O}(1)$ GeV with displaced-vertex search. Additionally, the EicC has the potential to probe axion-like particles (ALPs) in the mass range 0.1 GeV ≲ m a ≲ 5 GeV, with a coupling reach of Λ ≲ 10 6 GeV, by combining the prompt-decay and displaced-vertex searches. The projected sensitivities to ALPs exceed the current bounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Pulsed Laser System to Simulate Effects of Cosmic Rays in Semiconductor Devices

Spaceflight system electronic devices must survive a wide range of radiation environments with various particle types including energetic protons, electrons, gamma rays, x-rays, and heavy ions. High-energy charged particles such as heavy ions can pass straight through a semiconductor material and interact with a charge-sensitive region, generating a significant amount of charge (electron-hole pairs) along their tracks. These excess charges can damage the device, and the response can range from temporary perturbations to permanent changes in the state or performance. These phenomena are called single event effects (SEE). Before application in flight systems, electronic parts need to be qualified and tested for performance and radiation sensitivity. Typically, their susceptibility to SEE is tested by exposure to an ion beam from a particle accelerator. At such facilities, the device under test (DUT) is irradiated with large beams so there is no fine resolution to investigate particular regions of sensitivity on the parts. While it is the most reliable approach for radiation qualification, these evaluations are time consuming and costly. There is always a need for new cost-efficient strategies to complement accelerator testing: pulsed lasers provide such a solution. Pulsed laser light can be utilized to simulate heavy ion effects with the advantage of being able to localize the sensitive region of an integrated circuit. Generally, a focused laser beam of approximately picosecond pulse duration is used to generate carrier density in the semiconductor device. During irradiation, the laser pulse is absorbed by the electronic medium with a wavelength selected accordingly by the user, and the laser energy can ionize and simulate SEE as would occur in space. With a tightly focused near infrared (NIR) laser beam, the beam waist of about a micrometer can be achieved, and additional scanning techniques are able to yield submicron resolution. This feature allows mapping of all of the sensitive regions of the studied device with fine resolution, unlike heavy ion experiments. The problematic regions can be precisely identified, and it provides a considerable amount of information about the circuit. In addition, the system allows flexibility for testing the device in different configurations in situ.

Aveline, David C.

Sensitivity of an early dark matter search using the electromagnetic calorimeter as a target for the Light Dark Matter eXperiment

The Light Dark Matter eXperiment (LDMX) is proposed to employ a thin tungsten target and a multi-GeV electron beam to carry out a missing momentum search for the production of dark matter candidate particles. We study the sensitivity for a complementary missing-energy-based search using the LDMX Electromagnetic Calorimeter as an active target with a focus on early running. In this context, we construct an event selection from a limited set of variables that projects sensitivity into previously-unexplored regions of light dark matter phase space — down to an effective dark photon interaction strength y of approximately 2 × 10 −13 (5 × 10 −12 ) for a 1 MeV (10 MeV) dark matter candidate mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

The ABCs of phase retrieval: Connecting the acronyms of scanning transmission electron microscopy

High-resolution scanning transmission electron microscopy (S/TEM) is an indispensable tool for characterizing the structure and properties of materials down to the atomic scale. Conventional S/TEM imaging, however, is limited by the phase problem, whereby the phase of the electron exit wave is lost upon detection. Recent advances in diffractive imaging and 4D-STEM have enabled a range of phase-retrieval techniques that computationally reconstruct the missing information encoded in the phase of the transmission function. These approaches offer improved dose efficiency and enhanced sensitivity to weakly scattering signals, extending quantitative imaging to beam-sensitive materials composed of light elements. In this work, we introduce the phase problem in electron microscopy and survey the diverse landscape of phase-retrieval techniques used in the field. Despite their many acronyms and algorithmic variations, these techniques share a common physical and mathematical foundation. We present a unified framework that connects these seemingly distinct methods, from parallax imaging and tilt-corrected bright-field (tcBF-STEM), to aberration-corrected bright-field (acBF-STEM), optimum bright-field (OBF-STEM) and single-sideband (SSB) ptychography, as well as first-moment integrated center of mass techniques (iCOM) and iterative ptychographic algorithms. Based on these insights, we discuss the opportunities and practical limitations of applying these methods across different materials systems, detector designs, and microscope configurations.Graphical abstractRepresentative electron microscopy configurations used for phase retrieval and diffractive imaging in S/TEM: (a) Zernike phase-contrast transmission electron microscopy (TEM), (b) small-convergence-angle four-dimensional scanning transmission electron microscopy (4D-STEM) for nanobeam-based phase reconstruction methods, and (c) large-convergence-angle 4D-STEM for ptychographic and related diffractive imaging techniques reviewed in this work.

36 MATERIALS SCIENCE

LDMX -- The Light Dark Matter eXperiment

LDMX, The Light Dark Matter eXperiment, is a missing momentum search for hidden sector dark matter in the MeV to GeV range. It will be located at SLAC in End Station A, and will employ an 8 GeV electron beam parasitically derived from the SLAC LCLS-II accelerator. LDMX promises to expand the experimental sensitivity of these searches by between one and two orders of magnitude depending on the model. It also has sensitivity in visible ALP searches as well as providing unique data on electron-nucleon interactions.

Appert, Stephen [Caltech]

Framework of compressive sensing and data compression for 4D-STEM

Four-dimensional Scanning Transmission Electron Microscopy (4D-STEM) is a powerful technique for high-resolution and high-precision materials characterization at multiple length scales, including the characterization of beam-sensitive materials. However, the field of view of 4D-STEM is relatively small, which in absence of live processing is limited by the data size required for storage. Furthermore, the rectilinear scan approach currently employed in 4D-STEM places a resolution- and signal-dependent dose limit for the study of beam sensitive materials. Improving 4D-STEM data and dose efficiency, by keeping the data size manageable while limiting the amount of electron dose, is thus critical for broader applications. Here we introduce a general method for reconstructing 4D-STEM data with subsampling in both real and reciprocal spaces at high fidelity. The approach is first tested on the subsampled datasets created from a full 4D-STEM dataset, and then demonstrated experimentally using random scan in real-space. The same reconstruction algorithm can also be used for compression of 4D-STEM datasets, leading to a large reduction (100 times or more) in data size, while retaining the fine features of 4D-STEM imaging, for crystalline samples.

4D-STEM

Flavor-violating ALPs, electron g − 2 , and the Electron-Ion Collider

We revisit the possibility that light axionlike particles (ALPs) with lepton-flavor-violating couplings could give significant contributions to the electron’s anomalous magnetic moment g e − 2 . Unlike flavor diagonal lepton-ALP couplings, which are exclusively axial, lepton-flavor-violating couplings can have arbitrary chirality. Focusing on the e − τ ALP coupling, we find that the size of the contribution to g e − 2 depends strongly on the chirality of the coupling. A significant part of the parameter space for which such a coupling can explain experimental anomalies in g e − 2 can be probed at the Electron-Ion Collider, which is uniquely sensitive to the chirality of the coupling using the polarization of the electron beam. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Muon Neutrino Reconstruction at ICARUS with Machine Learning

The ICARUS T600 LArTPC detector successfully ran for three years at the underground LNGS laboratories, providing a first sensitive search for LSND-like anomalous electron neutrino appearance in the CNGS beam. After a significant overhauling at CERN, the T600 detector has been placed in its experimental hall at Fermilab, fully commissioned, and the first events observed with full detector readout. Regular data-taking began in May 2021 with neutrinos from the Booster Neutrino Beam (BNB) and neutrinos six degrees off-axis from the Neutrinos at the Main Injector (NuMI). Modern developments in machine learning have allowed for the development of an end-to-end machine learning-based event reconstruction for ICARUS data. This reconstruction folds in 3D voxel-level feature extraction using sparse convolutional neural networks and particle clustering using graph neural networks to produce outputs suitable for physics analyses. This poster will summarize the performance of a high-purity and high-efficiency end-to-end machine learning-based selection of muon neutrinos from the BNB and highlight studies of electromagnetic shower reconstruction from a neutral pion selection.

43 PARTICLE ACCELERATORS