Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrode interface”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Molecular-Scale Structure of Electrode–Electrolyte Interfaces: The Case of Platinum in Aqueous Sulfuric Acid

Knowledge of the molecular composition and electronic structure of electrified solid-liquid interfaces is key to understanding elemental processes in heterogeneous reactions. Using X-ray absorption spectroscopy in the interface-sensitive electron yield mode (EY-XAS), first-principles electronic structure calculations, and multiscale simulations, we determined the chemical composition of the interfacial region of a polycrystalline platinum electrode in contact with aqueous sulfuric acid solution at potentials between the hydrogen and oxygen evolution reactions. We found that between 0.7 and 1.3 V vs Ag/AgCl the electrical double layer (EDL) region comprises adsorbed sulfate ions with hydrated hydronium ions in the next layer. No evidence was found for bisulfate or Pt-O/Pt-OH species, which have very distinctive spectral signatures. In addition to resolving the long-standing issue of the EDL structure, our work establishes interface- and element-sensitive EY-XAS as a powerful spectroscopic tool for studying condensed phase, buried solid-liquid interfaces relevant to various electrochemical processes and devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoengineered membrane electrode assembly interface

A membrane electrode structure suitable for use in a membrane electrode assembly (MEA) that comprises membrane-affixed metal nanoparticles whose formation is controlled by a photochemical process that controls deposition of the metal nanoparticles using a photocatalyst integrated with a polymer electrolyte membrane, such as an ionomer membrane. Impregnation of the polymer membrane with the photocatalyst prior to metal deposition greatly reduces the required amount of metal precursor in the deposition reaction solution by restricting metal reduction substantially to the formation of metal nanoparticles affixed on or near the surface of the polymer membrane with minimal formation of metallic particles not directly associated with the membrane.

42 ENGINEERING↗

Computational Exploration of the Li-Electrode|Electrolyte Interface in the Presence of a Nanometer Thick Solid-Electrolyte Interphase Layer [Computational exploration of the Li-electrode|electrolyte interface complicated by a nanometer thin solid-electrolyte interphase (SEI) layer]

A nanometer thick passivation layer will spontaneously form on Li-metal in battery applications due to electrolyte reduction reactions. This passivation layer in rechargeable batteries must have “selective” transport properties: blocking electrons from attacking the electrolytes, while allowing Li + ion to pass through so the electrochemical reactions can continue. The classical description of the electrochemical reaction, Li + + e → Li 0 , occurring at the Li-metal|electrolyte interface is now complicated by the passivation layer and will reply on the coupling of electronic and ionic degrees of freedom in the layer. We consider the passivation layer, called “solid electrolyte interphase (SEI)”, as “the most important but the least understood in rechargeable Li-ion batteries,” partly due to the lack of understanding of its structure–property relationship. In predictive modeling, starting from the ab initio level, we find that it is an important tool to understand the nanoscale processes and materials properties governing the interfacial charge transfer reaction at the Li-metal|SEI|electrolyte interface. Here, we demonstrate pristine Li-metal surfaces indeed dissolve in organic carbonate electrolytes without the SEI layer. Based on joint modeling and experimental results, we point out that the well-known two-layer structure of SEI also exhibits two different Li + ion transport mechanisms. The SEI has a porous (organic) outer layer permeable to both Li + and anions (dissolved in electrolyte), and a dense (inorganic) inner layer facilitate only Li + transport. This two-layer/two-mechanism diffusion model suggests only the dense inorganic layer is effective at protecting Li-metal in electrolytes. This model suggests a strategy to deconvolute the structure–property relationships of the SEI by analyzing an idealized SEI composed of major components, such as Li 2 CO 3 , LiF, Li 2 O, and their mixtures. After sorting out the Li+ ion diffusion carriers and their diffusion pathways, we design methods to accelerate the Li + ion conductivity by doping and by using heterogonous structure designs. We will predict the electron tunneling barriers and connect them with measurable first cycle irreversible capacity loss. We note that the SEI not only affects Li + and e – transport, but it can also impose a potential drop near the Li-metal|SEI interface. Our challenge is to fully describe the electrochemical reactions at the Li - metal|SEI|electrolyte interface. This will be the subject of ongoing efforts.

30 DIRECT ENERGY CONVERSION↗

Operando FTIR Studies of Electrolyte Solution Structures and Dynamics at Electrode-Electrolyte Interfaces

The well-stabilized electrode-electrolyte interface (EEI) is critical to battery performance and safety, thus understanding the electrolyte solution structures (e.g., ion solvation and ionic association) and dynamics within EEI is an important area of study. Unfortunately, due to the sensitive nature of the electrodes, ex-situ characterization methods are limited and challenging to interpret as chemical and structural changes occur upon deconstructing the cell. In this work, we present operando characterization of near-surface electrolyte solution structures and dynamics by ATR-FTIR spectroscopy during battery cycling. We studied two selected model electrodes, a lithium nickel manganese cobalt oxide (NMC) or a planar silicon (Si), in a standard Gen2 electrolyte of 1.2 M LiPF6 in ethylene carbonate (EC):ethyl methyl carbonate (EMC) (3:7 wt%). In the former case, the composite cathode on aluminum foil is placed face-down on an ATR crystal. A ring of lithium metal serves as the counter/reference electrode and no separator is required. In the latter case, a lightly doped p-type silicon wafer is phosphorous-doped at the surface to increase the conductivity of the sample without compromising infrared transparency. The ATR crystal is then pressed on the back of the silicon with a minimal air gap to ensure sufficient optical contact between the two materials. The front of wafer is then placed in a modified coin-type cell geometry with a minimal electrolyte, a separator, and a lithium metal counter/reference electrode. In both experiments, we analyze the electrolyte solution structures within the EEI and find similar patterns as a function of potential. Firstly, we find that EMC decomposes faster than EC -suggesting that EMC plays a greater role in the electrochemical reactions on the electrode surface (e.g., formation of a protective layer to prevent further electrolyte decomposition). Secondly, we monitor the increase/decrease of the vibrational absorption peaks attributed to carbonates coordinated with Li+ ions relative to the decrease/increase of their uncoordinated counterparts, as expected when changing the local concentration of Li+ ions near the electrode surface during deintercalation/intercalation into the electrode. Finally, we observe that the features assigned to the Li+-PF6 -/-solvent molecules contact ion pair relative to the uncoordinated PF6 - anion. These observations give important information regarding the electrolyte solution structures and dynamics near the electrode surfaces. We look forward to applying these techniques to additional lithiumion battery systems with different cathode or anode materials and beyond lithium-ion systems to characterize surface chemistry/evolution (on-going research) and solution structures/dynamics (in particular, (de)solvation behaviors) within the EEI, which can be a bottleneck to efficient ion transfer from the electrolyte to the electrode.

14 SOLAR ENERGY↗

Quantitative study of non-covalent interactions at the electrode-electrolyte interface using cyanide-modified Pt(111) electrodes.

Cations at the outer Helmholtz plane (OHP) can interact through non-covalent interactions with species at the inner Helmholtz plane (IHP), which are covalently bonded to the electrode surface, thereby affecting the structure and the properties of the electrochemical double layer. These non-covalent interactions can be studied quantitatively using cyanide-modified Pt(111) electrodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Situ Mass Spectrometric Monitoring of the Dynamic Electrochemical Process at the Electrode–Electrolyte Interface: a SIMS Approach

The in situ molecular characterization of reaction intermediates and products at electrode-electrolyte interfaces is central to mechanistic studies of complex electrochemical processes, yet a great challenge. The coupling of electrochemistry (EC) and mass spectrometry (MS) has seen rapid development and found broad applicability in tackling challenges in analytical and bioanalytical chemistry. However, few truly in situ and real-time EC-MS studies have been reported at electrode-electrolyte interfaces. An innovative EC-MS coupling method named in situ liquid secondary ion mass spectrometry (SIMS) was recently developed by combining SIMS with a vacuum compatible microfluidic electrochemical device. Using this novel capability we report the first in situ elucidation of the electro-oxidation mechanism of a biologically significant organic compound, ascorbic acid (AA), at the electrode-electrolyte interface. The short-lived radical intermediate was successfully captured, which had not been detected directly before. Moreover, we demonstrated the power of this new technique in real-time monitoring of the formation and dynamic evolution of electrical double layers at the electrode-electrolyte interface. This work suggests further promising applications of in situ liquid SIMS in studying more complex chemical and biological events at the electrode-electrolyte interface.

Environmental Molecular Sciences Laboratory↗

In situ solid-state electrochemistry of mass-selected ions at well-defined electrode–electrolyte interfaces

Significance In situ characterization of kinetics at electrode–electrolyte interfaces (EEIs) is crucial to the rational design of efficient and sustainable solid-state electrochemical technologies. A significant advancement has been made to rationally understand processes at EEIs using solid-state in situ thin-film electrochemical cells fabricated using specially designed ionic liquid membranes with excellent mass-transfer properties. The in situ cells are used to characterize well-defined EEIs generated using ion soft-landing (SL) in controlled environments, both in vacuum and in the presence of reactant gases. Populating EEIs with precisely defined electroactive species using SL facilitates molecular-level understanding of electron transfer processes within deposited species and between species and electrodes, thus providing a powerful methodology to characterize technologically relevant EEIs during operation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-time Characterization of the Fine Structure and Dynamics of an Electrical Double Layer at Electrode-electrolyte Interfaces

The chemisorption of species from supporting electrolytes on electrode surfaces is ubiquitous in electrochemical systems and affects the dynamics and mechanism of various electrochemical reactions. The understanding of chemical structure and property of the resulting electrical double layer is vital but limited. In this work, we operando probed the electrochemical interface between a gold electrode surface and a common supporting electrolyte, phosphate buffer, using our newly developed in situ liquid secondary ion mass spectrometry. We surprisingly found that on the positively charged gold electrode surface sodium cations were anchored in the stern layer in a partially dehydrated form by formation of compact ion pairs with the accumulated phosphate anions. The resulting strong and dense adsorption phase was further revealed to retard the electro-oxidation reaction of ascorbate. This finding addressed one major gap in the fundamental science of electrode-electrolyte interfaces that where and how the cations reside in the double layer to impose effects on electrochemical reactions, providing insights into engineering of better electrode-electrolyte interfaces in electrochemical processes.

Zhang, Yanyan↗

In situ chemical probing of the electrode-electrolyte interface by ToF-SIMS

A portable vacuum interface allowing direct probing of the electrode-electrolyte interface was developed. A classical electrochemical system consisting of gold working electrode, platinum counter electrode, platinum reference electrode, and potassium iodide electrolyte was used to demonstrate real-time observation of the gold iodide adlayer on the electrode and chemical species as a result of redox reactions using cyclic voltammetry (CV) and the time-of-flight secondary ion mass spectrometry (ToF-SIMS, a vacuum-based surface analytical technique) simultaneously. This microfluidic electrochemical probe provides a new way to investigate the surface region with adsorbed molecules and region of diffused layer with chemical speciation in liquids in situ by surface sensitive techniques.

chemical imaging↗

Evolution of the Electrode–Electrolyte Interface of LiNi 0.8 Co 0.15 Al 0.05 O 2 Electrodes Due to Electrochemical and Thermal Stress

For layered oxide cathodes, impedance growth and capacity fade related to reactions at the cathode–electrolyte interface (CEI) are particularly prevalent at high voltage and high temperatures. At a minimum, the CEI layer consists of Li 2 CO 3 , LiF, reduced (relative to the bulk) metal-ion species, and salt decomposition species, but conflicting reports exist regarding their progression during (dis)charging. Utilizing transport measurements in combination with X-ray and nuclear magnetic resonance spectroscopy techniques in our work, we study the evolution of these CEI species as a function of electrochemical and thermal stress for LiNi 0.8 Co 0.15 Al 0.05 O 2 (NCA) particle electrodes using a LiPF 6 ethylene carbonate:dimethyl carbonate (1:1 volume ratio) electrolyte. Although initial surface metal reduction does correlate with surface Li 2 CO 3 and LiF, these species are found to decompose upon charging and are absent above 4.25 V. While there is trace LiPF 6 breakdown at room temperature above 4.25 V, thermal aggravation is found to strongly promote salt breakdown and contributes to surface degradation even at lower voltages (4.1 V). An interesting finding of our work was the partial reformation of LiF upon discharge, which warrants further consideration for understanding CEI stability during cycling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Capturing the transient species at the electrode–electrolyte interface by in situ dynamic molecular imaging

The electrochemical interface between the solid electrode and liquid electrolyte has long been studied because of its importance in electrical energy storage, material synthesis, catalysis, and energy conversions.1 However, such interfaces are complex and extremely difficult to observe directly and are poorly under-stood due to lack of true in situ tools.2 Although electrochemical techniques have been widely used to investigate such interfaces, they are based on macroscopic models or current changes that could not provide direct ionic and molecular information of the interfacial structure. Many in situ and ex situ spectroscopy and microscopy techniques have been used to study the solid–liquid (s–l) interface.3,4 In situ TEM in sealed liquid cells has notably become a popular choice to provide structural information of s–l at the atomic level.5,6 However, real-time spatial mapping of the ionic and molecular intermediate species at the dynamic inter-face still remains a key challenge.

Environmental Molecular Sciences Laboratory↗

In Situ Probing of Ion Ordering at an Electrified Ionic Liquid/Au Interface

Charge transport at the interface of electrodes and ionic liquids is critical for the use of the latter as electrolytes. In this study, a room-temperature ionic liquid, 1-ethyl-2,3-dimethylimidazolium bis(trifluoromethanesulfonyl)imide (EMMIM TFSI), is investigated in situ under applied bias voltage with a novel method using low-energy electron and photoemission electron microscopy. Changes in photoelectron yield as a function of bias applied to electrodes provide a direct measure of the dynamics of ion reconfiguration and electrostatic responses of the EMMIM TFSI. Finally, long-range and correlated ionic reconfigurations that occur near the electrodes are found to be a function of temperature and thickness, which, in turn, relate to ionic mobility and different configurations for out-of-plane ordering near the electrode interfaces, with a critical transition in ion mobility for films thicker than three monolayers.

36 MATERIALS SCIENCE↗

Methodology of Atomic Force Microscopy Visualization of Electrode–Electrolyte Interfaces

Electrochemical atomic force microscopy (EC-AFM) provides unprecedented insights into the microstructure of electrode–electrolyte interfaces during electrochemical reactions. However, performing EC-AFM measurements has many challenges, for example, drift, contamination, and probe degradation. We present solutions to these experimental issues through electrochemical cell design and carefully chosen experimental parameters. The possibility that the probes can react with the interface during scanning, generating false-positive electrochemical dynamics, is discussed as an example of the challenge of high-fidelity EC-AFM measurement. Here, we demonstrate this effect in highly ordered pyrolytic graphite and show that we could use electrochemical control of the AFM probe to enable high-fidelity in situ AFM visualization of solid–liquid interfaces during electrochemical reactions.

Electrochemical cells↗

Rational design of efficient electrode–electrolyte interfaces for solid-state energy storage using ion soft landing

Here, the rational design of improved electrode-electrolyte interfaces (EEI) for energy storage is critically dependent on a molecular-level understanding of ionic interactions and nanoscale phenomena. The presence of non-redox active species at EEI has been shown to strongly influence Faradaic efficiency and long-term operational stability during energy storage processes. Herein, we achieve substantially higher performance and long-term stability of EEI prepared with highly-dispersed discrete redox-active cluster anions (50 ng of pure ~0.7 nm size molybdenum polyoxometalate anions (POM) anions on 25 mg (≈ 0.2 wt%) carbon nanotube (CNT) electrodes) by complete elimination of strongly coordinating non-redox species through ion soft-landing (SL). For the first time, electron microscopy provides atomically-resolved images of individual POM species directly on complex technologically relevant CNT electrodes. In this context, SL is established as a versatile approach for the controlled design of novel surfaces for both fundamental and applied research in energy storage.

25 ENERGY STORAGE↗

A dynamic Monte Carlo study of anomalous current voltage behaviour in organic solar cells

We present a dynamic Monte Carlo (DMC) study of s-shaped current-voltage (I-V) behaviour in organic solar cells. This anomalous behaviour causes a substantial decrease in fill factor and thus power conversion efficiency. We show that this s-shaped behaviour is induced by charge traps that are located at the electrode interface rather than in the bulk of the active layer, and that the anomaly becomes more pronounced with increasing trap depth or density. Furthermore, the s-shape anomaly is correlated with interface recombination, but not bulk recombination, thus highlighting the importance of controlling the electrode interface. While thermal annealing is known to remove the s-shape anomaly, the reason has been not clear, since these treatments induce multiple simultaneous changes to the organic solar cell structure. The DMC modelling indicates that it is the removal of aluminium clusters at the electrode, which act as charge traps, that removes the anomalous I-V behaviour. Finally, this work shows that the s-shape becomes less pronounced with increasing electron-hole recombination rate; suggesting that efficient organic photovoltaic material systems are more susceptible to these electrode interface effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microfluidic electrochemical device and process for chemical imaging and electrochemical analysis at the electrode-liquid interface in-situ

A microfluidic electrochemical device and process are detailed that provide chemical imaging and electrochemical analysis under vacuum at the surface of the electrode-sample or electrode-liquid interface in-situ. The electrochemical device allows investigation of various surface layers including diffuse layers at selected depths populated with, e.g., adsorbed molecules in which chemical transformation in electrolyte solutions occurs.

36 MATERIALS SCIENCE↗

Microfluidic electrochemical device and process for chemical imaging and electrochemical analysis at the electrode-liquid interface in-situ

A microfluidic electrochemical device and process are detailed that provide chemical imaging and electrochemical analysis under vacuum at the surface of the electrode-sample or electrode-liquid interface in-situ. The electrochemical device allows investigation of various surface layers including diffuse layers at selected depths populated with, e.g., adsorbed molecules in which chemical transformation in electrolyte solutions occurs.

42 ENGINEERING↗