Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrode aging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Characterizing Dynamic Structure in Battery Electrodes by Time-Resolved Cryo-TEM

In recent years, cryogenic transmission electron microscopy (cryo-TEM) has enabled high-resolution characterization of sensitive battery materials by minimizing electron beam-induced artifacts and damage. Success of this technique relies on the preparation of thin, rapidly frozen samples, generally by disassembling batteries under inert atmosphere, transferring materials of interest to a TEM grid, and finally plunge freezing into a cryogen. In material degradation studies, this extensive time between electrochemical cycling and cryo-TEM characterization leaves room for structural relaxation, diffusion, and other dynamic processes that make it difficult to precisely correlate the imaged structure with the native structure that evolves during battery cycling or aging. Here, we present a method to integrate battery cycling with fast preparation of electrode samples for cryo-TEM. This enables higher fidelity between the structures characterized and the electrochemical state of interest, which we use to study deformation in silicon nanoparticle anodes for lithium-ion batteries.

CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS↗

Mechanistic understanding of aging behaviors of critical-material-free Li 4 Ti 5 O 12 //LiNi 0.9 Mn 0.1 O 2 cells with fluorinated carbonate-based electrolytes for safe energy storage with ultra-long life span

Behind-the-meter storage (BTMS) systems - a viable method to minimize potential risk of blackout events and stabilize the grid - require a different type of cost-effective energy storage with excellent safety, ultra-long (>20 years) cycle life and reasonable energy density compared that of electric vehicles. To increase the energy density and reduce the cost of a long-term cyclable lithium-titanate-based cell, it is required to employ a critical-material-free high voltage cathode and an electrolyte with good electrochemical and transport properties. In this report the long-term electrochemical performance and behaviors of selected critical-material-free Li 4 Ti 5 O 12 (LTO)//LiNi 0.9 Mn 0.1 O 2 (LNMO) full cells for BTMS applications are evaluated and analyzed in the optimized voltage range of 1.4-2.7 V at 45 degrees C with different fluorinated carbonate-based electrolytes. The fluoroethylene carbonate (FEC)-based electrolyte cell shows the highest capacity retention of 57.9% and Coulombic efficiency (CE) of 99.96% after 1000 cycles, potentially attributed to a dense, homogenous and less resistive LiF-rich solid-electrolyte interphase (SEI) layer formed on the surface of LTO that may mitigate electrolyte decomposition and maintain relatively low cell impedance during cycling. The 3,3,3-fluoroethylmethyl carbonate (F-EMC)-based electrolyte cell, however, presents the worst performance with lower capacity and a sharp decrease of CE, due to unstable and non-uniform SEI formation and continuous oxidative electrolyte decomposition. This mechanistic understanding of cell aging behaviors and failure mechanisms with detailed analysis of surface chemistry and electrode morphology can guide design of new electrode chemistries and electrolyte formulations for the development of BTMS batteries.

25 ENERGY STORAGE↗

Interplay of Electrode Heterogeneity and Lithium Plating

Lateral microstructure heterogeneity in anodes is known to induce nonuniform current density, state of charge, and lithium plating. This means that such electrode heterogeneity can limit the fast charging of lithium-ion batteries. In this work, a combination of experiments and simulation is employed to understand the effect of mm scale lateral heterogeneity on cell aging. A previously developed model was extended to efficiently simulate SEI formation and Li plating for independent regions of an electrode. The model consists of three parallel regions each described under a P2D framework and with a distinct ionic resistance and possibly active material loading. The results suggest that during fast charge when the active material is uniformly distributed across the three regions, the region with the highest resistance reaches the end of life sooner than the other regions. There is also positive feedback from Li metal filling the pores near the separator interface that further accelerates lithium plating. Lastly, when there is a non-uniform active material distribution associated with the ionic resistance heterogeneity, tight competition between regions can occur, leading to less overall lithium plating and plating that is more uniform between regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prelithiated SiO x /Graphite-NMC811 Cells: Capacity Loss, Impedance Rise and Hidden Degradation Pathways Revealed Using Three-Electrode Diagnostics

Electrodes containing SiO x /graphite (Gr) materials are attractive as anodes for high-energy lithium-ion batteries. However, their mechanical deformation, electrochemical response, and impedance evolution during long-term cycling are strongly coupled, complicating accurate diagnosis of performance fade mechanisms. In this work, the behavior of electrochemically prelithiated SiO x /Gr anodes paired with NMC811 cathodes is systematically investigated using techniques that include in-situ dilatometry, three-electrode electrochemistry, and multiscale post-cycling microscopy. The SiO x /Gr electrode exhibits a maximum expansion of 49% upon lithiation to 10 mV vs Li + /Li, with 84% of the expansion and 91% of the capacity being reversible. In full cells, relatively stable cycling with only 12% capacity fade over 500 cycles is observed. Three-electrode experiments reveal cell-level impedance growth, which is dominated by the NMC811 cathode: the SiO x /Gr anode exhibits minimal net impedance rise and an initial impedance decrease at low potentials. Despite this apparent electrochemical stability, cross-sectional SEM, PFIB tomography, and cryo-STEM reveal irreversible anode thickening caused by the accumulation of an inorganic-rich solid electrolyte interphase (SEI) permeating the anode bulk. Electrode potential-shift analysis further demonstrates that Li + ions released from lithium reservoirs in the prelithiated anode mask true lithium inventory loss during aging. These results demonstrate that low-expansion SiO x /Gr anodes can simultaneously exhibit favorable cycling and impedance metrics while undergoing substantial, hidden degradation, underscoring the importance of electrode-resolved diagnostics for evaluating prelithiated silicon-based anodes.

25 ENERGY STORAGE↗

Transparent and Conductive Inorganic/Polymer‐Composite Encapsulants for Long‐Term Perovskite Solar Cells Operation

An innovative inorganic/polymer-composite encapsulation scheme comprising a polymer-based transparent conductive composite (TCC) coupled with a transparent conductive oxide is introduced to extend the lifetime of moisture-sensitive devices such as perovskite solar cells (PSC). The TCC comprises conductive silver-coated polymethyl methacrylate (Ag-PMMA) microsphere fillers protruding from a transparent non-conductive polymer matrix. TCC samples (5% Ag-PMMA by area) demonstrate high optical transparencies (%T approx. 85% in the 370–1200 nm region), low out-of-plane electrical resistivities (R < 0.2 Ω cm 2 ), and equilibrium permeabilities of less than 1 g mm/m 2 /day, all of which are well-maintained after 1,000 hours of environmental exposure. In practice, the TCC is employed between two indium zinc oxide (IZO) thin films, with the in-plane conductivity of IZO and the out-of-plane conductivity of TCC working collectively to function as a single encapsulating electrode. This encapsulation scheme is exemplified by benchmarking performances of PSCs subjected to accelerated aging conditions of quasi-maximum power point tracking under light soaking in air at 50 °C, 40% R.H. to 60% R.H. Notable improvements in operational lifetimes are observed, with a champion encapsulated PSC maintaining over 90% of its initial efficiency of 21.65% for up to 1,430 hours, compare to less than 300 hours for an unencapsulated control.

14 SOLAR ENERGY↗

Quantifying the Impact of Charge Rate and Number of Cycles on Structural Degeneration of Li-Ion Battery Electrodes

A quantitative link between crack evolution in lithium-ion positive electrodes and the degrading performance on cells is not yet well established nor is any single technique capable of doing so widely available. Here, we demonstrate a widely accessible high-throughput approach to quantifying crack evolution within electrodes. The approach applies super-resolution scanning electron microscopy (SEM) imaging of cross-sectioned NMC532 electrodes, followed by segmentation and quantification of crack features. Crack properties such as crack intensity, crack width and length are quantified as a function of charge rate (1C, 6C, and 9C) and cycle number (25, 225, and 600 cycles). Hundreds of particles are characterized for statistical confidence in the quantitative crack measurements. The data on crack evolution is compared to electrochemical data from full cells and half cells with the NMC532 positive electrodes. We show that while crack evolution strongly correlates with capacity fade in the first 25 cycles, it does not correlate well for the following hundreds of cycles indicating that cracking may not be the dominant cause of capacity fade throughout the cycle-life of cells.

25 ENERGY STORAGE↗

Lithium-Ion Battery Life Model with Electrode Cracking and Early-Life Break-in Processes

This paper develops a physically justified reduced-order capacity fade model from accelerated calendar- and cycle-aging data for 32 lithium-ion (Li-ion) graphite/nickel-manganese-cobalt (NMC) cells. The large data set reveals temperature-, charge C-rate-, depth-of-discharge-, and state of charge (SOC)-dependent degradation patterns that would be unobserved in a smaller test matrix. Model structure is informed by incremental capacity analysis that shows loss of lithium inventory and cathode-material loss as the dominant capacity fade mechanisms. The model includes terms attributable to solid-electrolyte interface (SEI) growth, electrode cracking, cycling-driven acceleration of SEI growth, and "break-in" mechanisms that slightly decrease or increase available Li inventory early in life. The study explores what mathematical couplings of these mechanisms best describe calendar aging, cycle aging, and mixed calendar/cycle aging. Various approaches are discussed for extracting relevant stress factors from complex cycling profiles to predict lifetime during real-world battery loads using models trained on constant-current laboratory test results. The complexity of the present human-driven model identification process motivates future work in machine learning to more widely search and statistically discern the optimal model that correctly extrapolates capacity fade based on physical knowledge.

25 ENERGY STORAGE↗

Electrochemical Aging and Halogen Oxides Formation on Multiwalled Carbon Nanotubes and Fe 3 O 4 @g-C 3 N 4 Coated Conductive Membranes

Electrochemical membrane filtration is widely reported to enhance water contaminants' degradation or rejection via anodic oxidation or cathodic repulsion. Despite their advances, electrochemical membranes or electrocatalysts often suffer from corrosion or passivation, especially under strong electrode potentials or reactions. Moreover, the formation of toxic byproducts, such as chlorinated organic compounds and oxyhalides (e.g., ClO 4 - ) is another major concern. This study investigated the membrane aging processes of two types of conductive membranes, multiwalled carbon nanotubes (MWCNTs) and ferrite/graphitic carbon nitride hybrids (Fe 3 O 4 @g-C 3 N 4 ) coated on ceramic membranes. Under high current densities (~ 20 mA∙cm -2 ) with anodic potentials (~10 V), MWCNTs and Fe 3 O 4 @g-C 3 N 4 catalysts underwent evident oxidation as indicated by an increase of the intensity ratio of the Raman spectral bands (I D /I G ) and charge transfer resistance (R ct ) of two electrochemical membranes. Under variations of electrode potentials, chloride or bromide were shown to be oxidized to bromate (BrO 3 - ) and chlorate (ClO 3 - ) at levels of 1-10 mmol∙L -1 . The formation of BrO 3 - and ClO 3 - was dependent on the solution pH, current densities (1-20 mA∙cm -2 ), and initial concentrations of Br or Cl ions. Finally, to warrant a safe and rational design and operation of electrochemically reactive membrane processes, membrane aging and toxic byproduct's formation deserve careful characterization under relevant water filtration environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impacts of Dissolved Ni 2+ on the Solid Electrolyte Interphase on a Graphite Anode

Transition metal (e.g. Ni) ions dissolved from layered-structured Ni-rich cathodes can migrate to the anode side and accelerate the failure of lithium-ion batteries. The investigations of the impact and distribution of Ni species on the solid electrolyte interphase (SEI) on the anode are crucial to understand the failure mechanism. Herein, we used time-of-flight secondary ion mass spectroscopy (TOF-SIMS) coupled with multivariate curve resolution (MCR) analysis to intuitively characterize the distribution of Ni species in the SEI. We find that the SEI on the graphite electrode using an EC-based electrolyte exhibits a multi-stratum structure. During accelerated aging of the LiNi 0.88 Co 0.08 Mn 0.04 O 2 /graphite full cell, the dissolution of Ni aggravates significantly upon cycling. A strong correlation between the dissolved-Ni and organic species in the SEI on graphite is illustrated. Here, the ion-exchange reaction between Ni 2+ and Li + ions in the SEI is demonstrated to be the main reason for the increase of SEI resistivity.

25 ENERGY STORAGE↗

Investigation of Nanoparticle Degradation in Hydrogen Fuel Cell Systems through Automated Electron Microscopy

Proton exchange membrane fuel cells (PEMFC) are promising devices for the deployment of hydrogen-powered heavy-duty vehicles, providing a higher efficiency for similar driving range and fueling time than the existing ones. However, PEMFCs still encounter durability challenges mainly due to catalyst degradation in the cathode. Mitigating these performance losses requires a better understanding of the degradation mechanisms under heavy-duty accelerated stress tests (ASTs) [1]. Scanning transmission electron microscopy (STEM) combined with energy dispersive X-ray spectroscopy (EDS) are key tools for the analysis of Pt and PtCo nanoparticle size, spatial distribution and composition [2]. Electron tomography is also used to determine the rate and type of degradation of catalyst nanoparticles as a function of their position on the carbon support. In this work, automated data acquisition software, paired with a custom Python code, have been used to study the effect of different accelerated stress tests (ASTs) on nanoparticle coarsening [2]. Figure 1 shows high-angle annular dark-field (HAADF)-STEM images and EDS maps comparing the cathodes of membrane electrode assemblies (MEAs) following an electrocatalyst AST performed under H2/N2 with that of the heavy-duty AST performed under H2/air. We will discuss how AST conditions affect considerably the spatial distribution of the nanoparticles across the electrode between the membrane and microporous layer. Although the median particle size increased more in the MEA aged under the heavy-duty AST, as determined using a high-throughput image analysis, the quantitative EDS measurements demonstrate that the electrocatalyst AST resulted in more Pt and Co dissolution from the cathode, which is another important indicator of electrocatalyst degradation. We will further present the impact of the relative humidity (% RH) on the degradation mechanisms demonstrated using the same approach. Electron tomography has been used to distinguish the Pt nanoparticles residing on the carbon support surface (exterior) from those within the pore structure (interior) in order to determine the relative stability of interior and exterior nanoparticles. As shown in Figure 2, we will compare the Pt catalyst particle size at the beginning of test (BOT) and end of test (EOT), and discuss the importance of automating the electron tomography workflow, i.e. acquisition, reconstruction, and visualization, to increase sampling and determine the standard deviation of these measurement. The outlook for utilizing low-dose cryo-tomography for limiting damage to the catalyst, support, and especially proton-conducting ionomer will also be discussed [3].

Amichi, Lynda↗

Significance of a Solid Electrolyte Interphase on Separation of Anode and Cathode Materials from Spent Li-Ion Batteries by Froth Flotation

The separation of electrode active materials from spent Li-ion batteries (LIBs) by froth flotation is challenging due to the changes in surface properties of electrode active materials from cycling as well as the presence of organic binders. In this work, the froth flotation separation of aged anode and cathode composite materials from spent LIBs was systematically investigated after the materials were heat treated. The results show that aged anode and cathode materials from spent LIBs can be well separated from each other after a heating process in air at 400 degrees C and at which some of the PVDF binder remains intact. The underlying mechanism was investigated by X-ray photoelectron spectroscopy (XPS), contact angle measurements, and scanning transmission electron microscopy (STEM) coupled with energy-dispersive X-ray spectroscopy (EDX). The results from the XPS and contact angle measurements show that there is a hydrophilic and oxygen-rich layer on the surface of aged anode materials. This hydrophilic surface, associated with the solid electrolyte interface (SEI) layer, impacts the froth flotation process significantly. The results also show that both the SEI layers and PVDF binder residues on the surface are removed at 400 degrees C for an hour, restoring the hydrophobicity of the anode materials, which, in turn, benefits the separation of anode and cathode materials. The STEM/EDX elemental analysis data confirms that there are 20 nm-thick oxygen-rich SEI layers on the surfaces, which can be removed after a heating process. The present result illustrates the significance of the SEI layers in flotation separation of electrode materials and sheds new lights into the future development of the recycling processes for the separation of anode and cathode composite materials from spent Li-ion batteries.

25 ENERGY STORAGE↗

Pouch cells with 15% silicon calendar-aged for 4 years

Small amounts of high-capacity silicon-based materials are already used in the anode of commercial Li-ion batteries, helping increase their energy density. Despite their remarkable storage capability, silicon continu-ously reacts with the electrolyte, accelerating time-dependent cell performance fade. Nevertheless, very limited information is available on the specific consequences of this reactivity for the calendar aging of Li-ion cells. Here, we analyze aging effects on 450 mAh pouch cells containing 15 wt% of Si (and 73 wt% graphite) after storage at 21 °C for four years. We show that severe losses of Si capacity occurred due to particle isolation when cells were stored at high states of charge (SOC), but not when cells were fully discharged prior to storage. Impedance rise was also significantly higher when cells were kept at high SOCs and was mostly due to phenomena taking place at the cathode; the continuous electrolyte reduction at the anode did not lead to a major increase in bulk electrode resistance. A series of post-test characterization provided additional information on the effects of time and SOC on the calendar aging of Si-containing cells. In conclusion, our study highlights the many challenges posed by Si during calendar aging and can inform future studies in the field.

25 ENERGY STORAGE↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structure and dynamics of small polyimide oligomers with silicon as a function of aging

The effect of UV curing and shearing on the structure and behavior of a polyimide (PI) binder as it disperses silicon particles in a battery electrode slurry was investigated. PI dispersant effectiveness increases with UV curing time, which controls the overall binder molecular weight. Here, the shear force during electrode casting causes higher molecular weight PI to agglomerate, resulting in battery anodes with poorly dispersed Si particles that do not cycle well. It is hypothesized that when PI binder is added above a critical amount, it conformally coats the silicon particles and greatly impedes Li ion transport. There is an “interzonal region” for binder loading where it disperses silicon well and provides a coverage that facilitates Li transport through the anode material and into the silicon particles. These results have implications in ensuring reproducible electrode manufacturing and increasing cell performance by optimizing the PI structure and coordination with the silicon precursor.

36 MATERIALS SCIENCE↗

Open-Air Manufacturing of Efficient Large-Area Perovskite Solar Cells to Meet Stability and Cost Targets

This SETO-funded project (DE-EE0009516) developed a fully open-air manufacturing pathway for perovskite solar cells and modules, eliminating vacuum-based processing steps while improving device stability. Open-air ultrasonic spray deposition, solution combustion synthesis, rapid thermal processing, and atmospheric plasma curing were developed and optimized for all functional device layers — perovskite absorber, hole transport layers (HTLs), electron transport layers (ETLs), transparent conducting oxides (TCOs), and rear electrodes — without reliance on vacuum. Sprayed organic ETLs preserved perovskite crystal structure and enabled power conversion efficiencies exceeding 20%, and open-air processed TCOs and rear electrodes achieved optoelectronic performance comparable to sputtered alternatives at substantially lower manufacturing cost. Device stability was assessed through accelerated aging protocols aligned with IEC and ISOS standards, combined with high-throughput optical diagnostics that identified key degradation mechanisms and antagonistic interactions among heat, humidity, and illumination stressors. A comprehensive technoeconomic analysis quantified the cost and throughput advantages of open-air manufacturing over conventional vacuum-based processes, identifying vacuum deposition as the dominant cost driver and demonstrating a clear pathway toward the $0.02/kWh target. The project produced five peer-reviewed journal publications, eleven conference presentations, two patents/applications, and five Ph.D. dissertations.

14 SOLAR ENERGY↗

Rational designs to enable 10-min fast charging and long cycle life in lithium-ion batteries

A daunting challenge in the design of lithium ion batteries (LiBs) is enabling 10-min extreme fast charging (XFC) while achieving appreciable charge acceptance and cycle life. This desirable outcome requires both a comprehensive understanding of LiB operation and aging behavior at different length scales and careful optimization. Lithium plating has been a critical bottleneck because, at XFC rates, it consumes cyclable lithium causing distinct aging and safety concerns even in moderate-loading LiBs. Here, we propose combining multiple solutions, including materials-to-electrode design-to-charging protocols, that are intended to overcome limitations in lithium-ion transport in the electrolyte phase, thus enabling 10-min XFC in LiBs. Some implemented strategies include cathode chemistry, optimized carbon binder domain in the cathode, dual layer anode design, improved separator and advanced electrolyte. Further, innovative charging protocols in moderately loading (~3 mAh/cm 2 anode/2.7 mAh/cm 2 cathode) single-layer pouch cells are proposed, together with demonstrated 10-min XFC with higher charge acceptance between 87.3 and 92.1% (or 2–2.1 mAh/cm 2 ) for 600 cycles without lithium plating. This methodical study with well-defined cells shows promise in combining multiple solution strategies to enable 10-min XFC, charting a pathway to achieve XFC in higher-loading energy-optimized LiBs.

25 ENERGY STORAGE↗

Characterization of Cycle-Aged Commercial NMC and NCA Lithium-ion Cells: I. Temperature-Dependent Degradation

Lithium-ion batteries are widely used in applications from consumer electronic devices to stationary energy storage. Appropriate management of batteries is challenging due to limited data on their performance and materials degradation. Previous studies have focused on characterization of single cells under specific operating conditions. In the present work, commercial 18650 lithium-ion cells with LiNi x Mn y Co 1-x-y O 2 (NMC) and LiNi x Co y Al 1-x-y O 2 (NCA) positive electrodes were characterized by a wide range of electrochemical and materials techniques after cycling at 15, 25, or 35 °C to ∼80% capacity. The NCA cells exhibit weak temperature dependence in their cycle aging and materials degradation. The NMC cells exhibited increased capacity fade and materials degradation as ambient temperature decreased. All cells exhibited loss of lithium inventory as their primary degradation mode. However, the NCA cells only showed evidence of solid electrolyte interphase (SEI) growth whereas the NMC cells showed signs of Li plating at 15 °C, transitioning to SEI growth at 35 °C. The NMC cells displayed signs of loss of active material at the positive electrode at lower temperatures, suggesting that Li plating is correlated to additional processes that increase the rate of degradation. These results highlight the importance of avoiding broad generalizations about Li-ion battery temperature dependence.

25 ENERGY STORAGE↗