Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electricity storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Battery Energy Storage for Electric Vehicle Charging Stations

This help sheet provides information on how battery energy storage systems can support electric vehicle (EV) fast charging infrastructure. It is an informative resource that may help states, communities, and other stakeholders plan for EV infrastructure deployment, but it is not intended to be used as guidance, set policy, or establish or replace any standards under state or federal law.

ADVANCED PROPULSION SYSTEMS↗

Low‐cost, Long Duration Electrical Energy Storage Using a CO 2 ‐based Pumped Thermal Energy Storage

The increasing deployment of non‐dispatchable, intermittent renewable energy generation sources to address climate change is placing pressure upon electrical grids’ ability to match supply with demand. The need to deploy large quantities of long duration energy storage assets is rapidly approaching, and innovative methods of energy storage that are low cost, efficient, safe and environmentally benign are needed urgently. CO 2 ‐based Pumped Thermal Energy Storage (PTES) is a low cost, efficient and environmentally safe energy storage technology. PTES uses an electrically‐driven CO 2 heat pump to charge thermal reservoirs that are later used as resources to generate electricity using a CO 2 heat engine. In this program, Echogen and collaborators refined the design of a utility‐scale CO 2 PTES system and demonstrated key technologies that will be required for successful commercial development in a laboratory‐scale system. Component and system‐level performance was evaluated over multiple charge/discharge cycles, with favorable results. Echogen is continuing to develop and commercialize this technology at utility scale.

25 ENERGY STORAGE↗

Design and Techno-Economic Analysis of a 150-MW Hybrid CSP-PV Plant

The interest in concentrated solar power (CSP) has increased significantly over the years since it is dispatchable and requires thermal storage instead of electric storage. When compared to photovoltaics (PV), CSP has a higher Levelized Cost of Electricity (LCOE). In this paper, we present the design of a hybrid power plant using CSP and PV technologies. The hybrid system offers a lower LCOE than CSP but will still have dispatchability. The 150-MW hybrid system consists of 100-MW CSP and 50-MW PV capacity. Furthermore, the CSP system (central receiver system) has a molten salt-based thermal storage of 12 hours. The geographical focus of this study is Pakistan, which is a developing country struggling with energy crises, but which has high solar potential. The hybrid system is modeled using the System Advisor Model (SAM). The results show that by hybridizing CSP with PV, the LCOE can be reduced by 18.5%.

concentrated solar power↗

The Role of Energy Storage in the Uptake of Renewable Energy: A Model Comparison Approach

The power sector needs to ensure a rapid transition towards a low-carbon energy system to avoid the dangerous consequences of greenhouse gas emissions. Storage technologies are a promising option to provide the power system with the flexibility required when intermittent renewables are present in the electricity generation mix. This paper focuses on the role of electricity storage in energy systems with high shares of renewable sources. The study encompasses a model comparison approach where four models (GENeSYS-MOD, MUSE, NATEM, and urbs - MX) are used to analyse the storage uptake in North America. The analysis addresses the conditions affecting storage uptake in each country and its dependence on resource availability, technology costs, and public policies. Results show that storage may promote emissions reduction at lower costs when renewable mandates are in place whereas in presence of carbon taxes, renewables may compete with other low-carbon options. The study also highlights the main modelling approach shortcomings in the modelling of electricity storage in integrated assessment models.

electricity storage↗

SUBTASK 1.6 – BASIN ELECTRIC CARBON STORAGE RESEARCH PROJECT: NOVEL MONITORING TECHNIQUES

The Energy & Environmental Research Center (EERC) conducted baseline activities associated with an applied research project at Basin Electric Power Cooperative’s (Basin’s) carbon capture and storage (CCS) site in Beulah, North Dakota, to establish novel carbon storage-monitoring techniques as commercial methods under Cooperative Agreement No. DE-FE0024233, Subtask 1.6. The following report summarizes the baseline activities performed and briefly describes the subsequent (operational monitoring) activities that have been proposed to the U.S. Department of Energy (DOE) as part of the overall project to develop and demonstrate novel monitoring techniques at North America’s largest permitted CCS operation. Dakota Gasification Company (DGC), a wholly owned subsidiary of Basin, owns and operates the Great Plains Synfuels Plant (GPSP) approximately 5 miles northwest of the town of Beulah, North Dakota (Figure 1). In 2023, DGC received approval from the North Dakota Industrial Commission (NDIC) to develop a storage facility on-site for injecting a stream of carbon dioxide (CO2) captured from GPSP. DGC will transport the captured CO2 stream with approximately 6.8 miles of transmission lines that extend north of GPSP and inject >1 million tonnes (MMt) of CO2 annually (>1 MMt/yr) over a 12-year period with up to six underground injection control (UIC) Class VI-compliant injection wells completed in the Broom Creek Formation, a predominantly sandstone reservoir and saline aquifer underlying GPSP. The Broom Creek Formation lies approximately 5900 feet (ft) below ground surface (bgs) at GPSP. The commercial scale (i.e., >1 MMt/yr) of DGC’s permitted carbon storage project is ideal for developing and testing the novel monitoring techniques included within Subtask 1.6. The goals of this project are to demonstrate 1) the cost-effectiveness of novel monitoring technologies included as part of this research, 2) technology capability for tracking the CO2 plume and/or associated pressure response in the subsurface and monitoring out-of-zone migration, and 3) compliance with UIC Class VI program requirements. The research activities proposed for the overall project include 1) design of an automated, integrated, modular (AIM) monitoring station; 2) time-lapse electromagnetic (EM) field surveys; 3) drone-based surveillance studies; 4) time-lapse monitoring with seismic methods; 5) advanced wellbore-monitoring methods; 6) deployment of an AIM monitoring network; 7) EM monitoring of CO2 with real-time data processing; 8) continued seasonal drone-based surveillance studies; 9) seismic monitoring with passive and active surveys; and 10) wellbore monitoring with nuclear magnetic resonance (NMR) for near-surface characterization. Completion of Activities 1.0–5.0 (baseline activities) are described in this report. Upon authorization of funding by DOE, the EERC will initiate Activities 6.0– 10.0 (operational monitoring activities). Current state-of-the-art (SOA) carbon storage-monitoring techniques require countless labor hours dedicated to the acquisition of data. Once data are gathered, these SOA techniques often rely on commercial facilities to process raw data from the field. However, it is anticipated that next-generation monitoring techniques, such as those being demonstrated, will lower acquisition footprints, be less operationally intensive, and improve data acquisition efficiencies. These new techniques are more conducive to the application of machine learning, artificial intelligence, and automation, thus providing a pathway for integration into active control systems, informing site operability, and improving the integration of data for future CCS projects across the United States. Additionally, reclaimed and active mining lands are present within the project site, creating a unique opportunity to demonstrate the effectiveness of remote sensing and surface-based geophysics monitoring techniques at similar project sites that may include disturbed, unconsolidated, or actively excavated near-surface environments. The efforts included in the overall project will produce necessary designs, learnings, and data acquired during the baseline and operational monitoring periods that are necessary for time-lapse demonstration and validation of the described monitoring techniques. In addition, it is anticipated that the monitoring technologies included in this study will be compliant with UIC Class VI requirements to enable the potential for implementation at other CCS sites across the United States.

42 ENGINEERING↗

Modeling the Potential Impact of Storage on the US Power Sector in a Multisector Dynamic Context

The electric power sector is expected to grow in size, importance, and complexity around the world as economies expand and electric supply technologies and demand patterns evolve in significant ways. At the same time the electric power sector may see substantial increases in VRE generating technologies which can add variability and uncertainty to the diurnal and seasonal profile of electric supply. With these forces in play, the emergence of modular, flexible electricity storage technologies may have profound impacts on the operation of electric power systems. Here we reduce a storage modeling gap in MSD models by incorporating grid-based electricity storage into the electric sector dynamics of the Global Change Analysis Model-USA (GCAM-USA) with improved power sector representation. We find a potentially significant role for storage technologies in the future of the U.S. power system, with storage capacity ranging from 7.7 to 14.7 GW in 2050 and 13.9 to 31.6 GW in 2100 across several techno-economic scenarios. We also find that storage can help to smooth variability in residual load arising from evolving electricity demands and the introduction of high shares of VRE to the electric grid. This reduces reliance on high-cost peaking generators, improves system-wide capacity factors, and limits curtailment of VRE.

Patel, Pralit L.↗

An Introductory Guide to Generating, Using, and Storing Energy: Understanding electricity, energy storage, microgrids, and related technologies

This guide was created to empower Energy Storage for Social Equity (ES4SE) community members to learn more about power systems, energy distribution, renewable energy, and battery storage systems. It was developed in an accessible format for audiences of varied backgrounds and requires no previous experience in energy storage. It is intended to serve readers as both an educational and reference document as they consider, procure, and deploy power systems that include battery energy storage technologies and microgrids in their communities. By providing an introductory overview of the basics of electricity, power generation, and household energy consumption and loads, this guide prepares readers to learn even more about battery energy storage, microgrid systems, and the sizing of solar and battery systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Prefeasibility Analysis of Behind-the-Meter Distributed Energy Resources in Highland Park, MI: Highland Park Pathways to Power [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "B" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development. NREL used the REopt platform to evaluate the techno-economic potential of adding solar PV, electric storage, and/or diesel generators at several locations in Highland Park, Michigan: a typical residential and commercial building in Highland Park, the Earnest T. Ford Recreation Center, and the Parker Village Microgrid. The analysis goals focused on the ability of solar PV, electric storage, and/or diesel generators to reduce electricity costs and improve site resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LA100 Equity Strategies. Chapter 12: Distribution Grid Upgrades for Equitable Resilience and Solar, Storage, and Electric Vehicle Access

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. As Los Angeles transitions toward clean energy, existing distribution grid infrastructure will need to be updated and expanded to support reliable service during routine operations, enable interconnection with distributed energy resources and electrified loads, and provide access to energy-related services during disasters. This chapter focuses on equity in distribution grid upgrades, reliability, and resilience in Los Angeles. Specifically, NREL performed grid upgrade and resilience analyses using a detailed model of the distribution grid and income-differentiated household load profiles, electric vehicle (EV) adoption patterns, distributed solar adoption, and grid reliability to explore two key questions to inform how the City of Los Angeles can ensure a resilient and reliable distribution grid for all communities during the clean energy transition: Where can distribution system upgrades can be prioritized to enable equitable access to, and adoption of, clean energy technologies and how can Los Angeles provide equitable, resilient access to electricity-related services (e.g., health care, food) during disaster events like earthquakes and flooding? The electric distribution system is the "last mile" of the grid, linking the multistate bulk power system with customers; new loads, including EVs; and distributed energy resources, such as customer and community solar and storage. This analysis focuses on the 4.8-kilovolt (kV) system, including service transformers that represent the utility-side of the grid connection for most residential customers. Chapter 17 looks at the customer-side of the grid connection with a focus on electric panel upgrade needs. The transition toward clean energy can put additional stress on the distribution system from distributed energy resources and electrification - especially EVs and increased use of electricity for heating, cooling, cooking, and hot water. This stress, measured here as the number of equipment overloads and voltage violations, correlates strongly to grid reliability and therefore is used as a proxy for understanding additional upgrades needed and to help ensure equitable access to electrification and distributed energy resources. NREL also conducted community resilience analysis to examine customer-level access to both electricity and a larger range of services, such as hospitals and grocery stores during a disaster. This analysis explicitly considers equity to understand differences in current resilience and resilience strategies to effectively improve critical services access for all Angelenos. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

14 SOLAR ENERGY↗

Probing the Sustainable Reduction of CO 2 , N 2 and NO 3 to Fuels and Chemicals using Non-Traditional Porphyrinoid Catalysts

For the last several decades, numerous strategies have been proposed to be able to interconvert electricity and commodity fuels for transportation and other applications. Even as solar and wind energy become more widely available, these renewable energy sources are not always available where the population is most dense or during peak times of energy demand. One plausible solution to the issue of electricity storage and transport is to use electricity to drive the formation of high-energy compounds and chemical fuels. As a result, the electrochemical conversion of CO 2 into chemical fuels has received major attention as a multi-pronged approach for electricity coversion, storage, and transport. Similar strategies are also attractive for conversion of N 2 and NO x into value added compounds such as ammonia. Metalloporphyrin and metallocorrole complexes are comprised of aromatic tetrapyrrole scaffolds and have been extensively studied as homogeneous catalysts for critical catalytic processes like the electrochemical CO 2 reduction reaction (eCO 2 RR) to generate CO as feedstock for the Fischer–Tropsch process to generate a variety of hydrocarbons as chemical fuels. Despite their significance and impact, efficiently driving such catalytic reduction processes is challenging for multiple reasons. Such processes require multiple-electron transfer events, as opposed to single-electron redox chemistry that forms high-energy singly-reduced intermediates. In addition, these electron transfer events must be coupled to proton-transfer steps and avoid application of high overpotentials where proton (H + ) reduction to generate H 2 (as well as other side-reactions) can lower the selectivity and energy efficiency of the eCO 2 RR process. Certain Fe(III) aromatic tetrapyrroles (e.g., porphyrins and corroles) have been reported to overcome these challenges, but are often difficult to synthesize and modify, and have a tendency to support single-electron redox chemistry at the metal as opposed to multielectron redox involving the ligand and metal in concert. Other families of tetrapyrroles in which all four meso-carbons are reduced (i.e., sp 3 -hybridized) are also known in the literature. These non-aromatic tetrapyrroles are known as porphyrinogens and support multi-electron redox chemistry which has been elaborated by several groups, prompting researchers to consider whether these scaffolds may improve the kinetics and efficiencies of multi-electron steps attendant to activation of thermodynamically stable small-molecule substrates such as CO 2 , N 2 , NO 3 − , and NO 2 − . Although porphyrinogens support multi-electron redox properties, the four sp 3 -hybridized meso-carbons inherent to the tetrapyrrole core completely disrupt π-conjugation between pyrrolic units, which compromises the photochemical properties of porphyrinogens in comparison to that of traditional porphyrinoids. Moreover, the highly reducing nature of porphyrinogens predisposes these platforms to extreme air and water sensitivity. Accordingly, such metalated porphyrinogens are often pyrophoric and/or incompatible with many common organic solvents (CH 2 Cl 2 , CHCl 3 , CH 3 CN, EtOAc, etc.). Hence, reports of efficient small-molecule activation or catalysis supported by porphyrinogens have been limited. To overcome the instability of porphyrinogens while retaining the scaffold’s attractive multi-electron redox properties, we have directed attention to establishing less-well studied groups of non-aromatic tetrapyrroles (i.e., phlorins, biladienes, and isocorroles). These non-traditional tetrapyrroles each contain just a single sp 3 -hybridized meso-carbon, which ablates the platforms aromaticity but still provides an extended π-framework. In addition to developing innovative platforms that may be used to sustainably generate value-added chemicals, fuels, and ammonia via either photo- or electrocatalytic approaches our work also has significantly broadened our understanding of how to prepare and modulate the properties of non-aromatic tetrapyrroles for other applications. Our efforts entailed a synergistic partnership and active collaborations with Drs. David C. Grills and Mehmed Z. Ertem (both of Brookhaven National Lab) to better characterize isocorroles (and related non-aromatic tetrapyrroles) using a variety of advanced spectroscopic and theoretical methods. Our combined efforts have shown that the combination of properties that isocorroles (and related tetrapyrroles) provide results in good chemical stability paired with unique redox and photochemical characteristics that are not typically supported by simple and/or unadorned aromatic tetrapyrroles. Beside redox chemistry, the photochemistry of isocorroles and other non-aromatic tetrapyrroles containing one sp 3 -hybridized meso-carbon is also appealing due to their absorption in the long-visible to near-IR regions, which are essential for photocatalysis and related applications that benefit from direct excitation at these wavelengths. The results reported vastly improve our understanding of non-aromatic tetrapyrrole synthesis, properties and utility for activation of small molecule substrates such as O 2 and CO 2 in the presence of weak cationic organic acids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Findings on subtask 1.6 – basin electric carbon storage research project: novel monitoring techniques

The Energy & Environmental Research Center (EERC) led a study to validate novel and emerging technologies as commercial monitoring techniques for application in carbon dioxide (CO 2 ) injection operations. This applied research was conducted at Basin Electric Power Cooperative’s (Basin Electric’s) active CO 2 -injection operations in Beulah, North Dakota, in two phases. The EERC previously completed a set of baseline (preinjection) activities in Phase 1, which included 1) design of an automated, integrated, modular (AIM) monitoring station; 2) time-lapse electromagnetic (EM) field surveys; 3) drone-based surveillance studies; 4) time-lapse monitoring with seismic methods; and 5) advanced wellbore-monitoring methods.

54 ENVIRONMENTAL SCIENCES↗

Electrolyte Takeover Strategy for Performance Recovery in Polysulfide-Permanganate Flow Batteries

The abundance of active material precursors for a polysulfide-permanganate flow battery makes it a compelling chemistry for large-scale, and potentially long-duration (>10 h), grid electricity storage. Precipitation, arising from either reactant crossover or electrolyte side reactions, decrease cell efficiencies during charge/discharge cycling. Regardless of the abundance and low cost of active materials, a system without high cyclability cannot meet grid electricity storage economic targets for applications that cycle regularly. Precipitated species can be removed, and reactor efficiency performance restored, by using an electrolyte takeover process, or ETP. Two ETP methods are investigated. One ETP uses the negative electrolyte, an alkaline polysulfide (pS) solution, as takeover solution, and another uses dilute acidic peroxide (DAP) as the takeover solution. Both ETPs maintain functional cell operation within an acceptable performance range over >1000 h and >200 cycles, a duration over which cells that do not undergo ETPs clog and fail. The DAP ETP proves especially effective and limits irrecoverable voltage efficiency fade below 0.02%/cycle. These ETPs, either individually, or in combination, can enable the requisite cyclability for practical polysulfide-permanganate flow battery systems.

25 ENERGY STORAGE↗

Integrated Heat Pump Thermal Storage and Power Cycle for CSP (Final Technical Report)

Pumped thermal energy storage (PTES) is a storage system that stores electricity in thermal reservoirs. In this project, methods of integrating PTES with concentrating solar power (CSP) systems were investigated and their feasibility evaluated. Hybrid "solar-PTES" devices can provide both flexible renewable power generation as well as a variety of electricity storage services. Techno-economic models of PTES and solar-PTES were developed and used to assess their performance, cost, and commercial viability. Systems were optimized using multi-objective optimization techniques. The value that these storage devices provide to the grid was estimated using production cost modelling. Key advances made in this project include the development of detailed techno-economic models that improve state-of-the-art assessments of these technologies. Off-design models were developed and used in grid-analysis models. This work describes for the first time how PTES and solar-PTES behave over a range of operating points and assesses the value that these systems can provide to the electrical grid. Feedback was obtained from experts in the field, which clarified key technological and economic barriers that must be addressed to improve the feasibility of these devices.

14 SOLAR ENERGY↗

Supercritical CO2 Heat Pumps and Power Cycles for Concentrating Solar Power

Pumped Thermal Energy Storage (PTES) is a promising technology for electricity storage applications. An electrically driven heat pump moves energy from a cold space to a hot space, thereby creating hot and cold thermal storage. The temperature difference between the hot and cold storage is later used to drive a heat engine and return electricity to the grid. In this article, supercritical carbon dioxide (sCO2) is chosen as the working fluid for PTES, and results are compared to 'conventional' systems that use nitrogen. Molten salts are used for the hot storage which means that a CSP plant with thermal storage and an sCO2 power cycle could potentially be hybridized with PTES by the addition of a heat pump. This article describes some of the benefits of this combined system which can provide renewable power generation and energy management services. Two methods by which an sCO2 heat pump can be combined with an sCO2 power cycle for CSP are described and techno-economic results are presented. Results indicate that these systems can achieve reasonable technical performance, but that costs are currently high.

carnot battery↗

Supercritical CO2 Heat Pumps and Power Cycles for Concentrating Solar Power: Preprint

Pumped Thermal Energy Storage (PTES) is a promising technology for electricity storage applications. Grid electricity drives a heat pump which moves energy from a cold space to a hot space, thereby creating hot and cold thermal storage. The temperature difference between the storage is later used to drive a heat engine and return electricity to the grid. In this article, supercritical carbon dioxide (sCO2) is chosen as the working fluid for PTES, and results are compared to ‘conventional’ systems that use an ideal gas. Molten salts are used for the hot storage which means that a CSP plant with thermal storage and an sCO2 power cycle could potentially be hybridized with PTES by the addition of a heat pump. This article describes some of the benefits of this combined system which can provide renewable power generation and energy management services. Two methods by which an sCO2 heat pump can be combined with an sCO2 power cycle for CSP are described and techno-economic results are presented. Results indicate that these systems can achieve reasonable technical performance, but that costs are currently high.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Advancing Pumped Thermal Energy Storage Performance and Cost Using Silica Storage Media

Pumped Thermal Energy Storage (PTES) is an electricity storage system that is suitable for long-duration energy storage (10-1000 h) due to its low marginal cost of energy capacity. We present a techno-economic model of a PTES system that uses particle thermal energy storage. Particles have low costs and can be operated over a wide temperature range leading to increased efficiency and reduced costs compared to other PTES designs. We show how the round-trip efficiency, specific power output, capital cost, and levelized cost of storage (LCOS) depend on parameters such as the pressure ratio, heat exchanger approach temperature and pressure loss, and maximum temperature. We compare particle-PTES (P-PTES) performance to PTES which uses liquid thermal energy storage - i.e. molten salt hot storage and methanol cold storage (MS-PTES). We find that using silica particles for storage advances PTES technology: P-PTES can be operated at higher maximum temperatures than MS-PTES. Furthermore, P-PTES can achieve lower approach temperatures in the heat exchangers than MS-PTES without increasing capital costs, because P-PTES uses direct-contact heat transfer in fluidized bed heat exchangers. As a result, we find that P-PTES systems achieve higher round-trip efficiency than MS-PTES (66 % versus 57 %) and lower LCOS (e.g. 0.115 +- 0.03 $/kWhe versus 0.171 +- 0.04 $/kWhe for 10 h discharge). The low cost of particles and containment means that P-PTES can provide long-duration energy storage at low capital cost per unit energy capacity. For example, the total capital cost per unit energy reduces from 245 $/kWhe at 10 h to 38 $/kWhe at 100 h. These costs are considerably lower than MS-PTES (72 $/kWhe at 100 h) and also outcompete current and future Li-ion battery system projections (100-265 $/kWhe).

25 ENERGY STORAGE↗