Engineering PapersSearch

SEARCH · Engineering Papers

Results for “electricity profiles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Hourly Load Profile Dataset for Electric Airport Ground Support Equipment in the United States

Currently, there are limited data on the magnitude and timing of electricity demand from electric ground support equipment (eGSE) across U.S. airports. To address this gap, this study presents a modeling approach for estimating hourly annual electricity demand from eGSE at the 50 largest U.S. commercial airports. These datasets, accessible at data.nrel.gov/submissions/279, provide critical insights into the potential grid impacts and electricity demand associated with eGSE adoption.

33 ADVANCED PROPULSION SYSTEMS

The effect of Be/+/ ion implanted exponential and uniform impurity profiles on the electrical characteristics of GaAs solar cells

The high surface recombination velocity is the major deterrent to obtaining efficient GaAs solar cells. If, however, an electric field is built in at the surface, the carriers will be swept away from the surface thus minimizing the surface recombination velocity problem. It has been previously shown theoretically that an exponential impurity distribution in the doped region of the cell results in a built-in electric field. Ion implantation was used to produce solar cells with an exponential impurity profile and cells with uniform profiles. It is shown that cells with an exponential impurity profile have higher open-circuit voltage, fill factors, and spectral response than those with a uniform impurity profile.

Vaidyanathan, K. V.

Addressing the Split Incentive Challenge for Enhanced Solar Adoption in Multifamily Rental Properties [Abstract]

The split incentive problem is particularly pronounced in rental markets, where landlords prioritize investments that directly increase property value or rental income. Since energy savings from solar photovoltaic (PV) systems primarily benefit tenants, landlords may perceive little return on investment unless mechanisms exist to recapture some of the financial gains. The primary objective of this project is to develop a publicly available, web-based tool to analyze the U.S. Department of Energy’s ResStock database, which models the U.S. residential building stock. The tool allows users to filter buildings by location, type, HVAC system, square footage, and other characteristics, and outputs typical electric load profiles. By leveraging location-specific electric load data, Fram Energy aims to advance business strategies that address the split incentive barrier and promote the adoption of solar PV installations in rental properties. In addition, a machine learning model will be developed to weigh the marginal contribution of building features across the dataset in predicting electricity demand, supporting guided decision making in forecasting electric load profiles. Lastly, based on each building’s location, load profile, and utility’s electricity rate, an optimized solar photovoltaic array and battery energy storage system will be sized to provide energy arbitrage opportunities.

14 SOLAR ENERGY

Calculated Coupling Efficiency Between an Elliptical-Core Optical Fiber and a Silicon Oxynitride Rib Waveguide [Corrected Copy]

The effective-index method and Marcatili's technique were utilized independently to calculate the electric field profile of a rib channel waveguide. Using the electric field profile calculated from each method, the theoretical coupling efficiency between a single-mode optical fiber and a rib waveguide was calculated using the overlap integral. Perfect alignment was assumed and the coupling efficiency calculated. The coupling efficiency calculation was then repeated for a range of transverse offsets.

Tuma, Margaret L.

Feasibility of Coupling Between a Single-Mode Elliptical-Core Fiber and a Single Mode Rib Waveguide Over Temperature

To determine the feasibility of coupling the output of an optical fiber to a rib waveguide in a temperature environment ranging from 20 C to 300 C, a theoretical calculation of the coupling efficiency between the two was investigated. This is a significant problem which needs to be addressed to determine whether an integrated optic device can function in a harsh temperature environment. Because the behavior of the integrated-optic device is polarization sensitive, a polarization-preserving optic fiber, via its elliptical core, was used to couple light with a known polarization into the device. To couple light energy efficiently from an optical fiber into a channel waveguide, the design of both components should provide for well-matched electric field profiles. The rib waveguide analyzed was the light input channel of an integrated-optic pressure sensor. Due to the complex geometry of the rib waveguide, there is no analytical solution to the wave equation for the guided modes. Approximation or numerical techniques must be utilized to determine the propagation constants and field patterns of the guide. In this study, three solution methods were used to determine the field profiles of both the fiber and guide: the effective-index method (EIM), Marcatili's approximation, and a Fourier method. These methods were utilized independently to calculate the electric field profile of a rib channel waveguide and elliptical fiber at two temperatures, 20 C and 300 C. These temperatures were chosen to represent a nominal and a high temperature that the device would experience. Using the electric field profile calculated from each method, the theoretical coupling efficiency between the single-mode optical fiber and rib waveguide was calculated using the overlap integral and results of the techniques compared. Initially, perfect alignment was assumed and the coupling efficiency calculated. Then, the coupling efficiency calculation was repeated for a range of transverse offsets at both temperatures. Results of the calculation indicate a high coupling efficiency can be achieved when the two components were properly aligned. The coupling efficiency was more sensitive to alignment offsets in the y direction than the x, due to the elliptical modal profile of both components. Changes in the coupling efficiency over temperature were found to be minimal.

Tuma, Margaret L.

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY

Calculated coupling efficiency between an elliptical-core optical fiber and an optical waveguide over temperature

To determine the feasibility of coupling the output of a single-mode optical fiber into a single-mode rib waveguide in a temperature varying environment, a theoretical calculation of the coupling efficiency between the two was investigated. Due to the complex geometry of the rib guide, there is no analytical solution to the wave equation for the guided modes, thus, approximation and/or numerical techniques must be utilized to determine the field patterns of the guide. In this study, three solution methods were used for both the fiber and guide fields; the effective-index method (EIM), Marcatili's approximation, and a Fourier method. These methods were utilized independently to calculate the electric field profile of each component at two temperatures, 20 C and 300 C, representing a nominal and high temperature. Using the electric field profile calculated from each method, the theoretical coupling efficiency between an elliptical-core optical fiber and a rib waveguide was calculated using the overlap integral and the results were compared. It was determined that a high coupling efficiency can be achieved when the two components are aligned. The coupling efficiency was more sensitive to alignment offsets in the y direction than the x, due to the elliptical modal field profile of both components. Changes in the coupling efficiency over temperature were found to be minimal.

Tuma, Margaret L.

Lunar magnetic field measurements, electrical conductivity calculations and thermal profile inferences

Steady magnetic field measurements of magnitude 30 to 100 gamma on the lunar surface impose problems of interpretation when coupled with the nondetectability of a lunar field at 0.4 lunar radius altitude and the limb induced perturbations of the solar wind at the Explorer orbit. The lunar time-varying magnetic field clearly indicates the presence of eddy currents in the lunar interior and permits calculation of an electrical conductivity profile. The problem is complicated by the day-night asymmetry of the moon's electromagnetic environment, the possible presence of the transverse magnetic mode, and the variable wave directions of the driving function. The electrical conductivity is calculated to be low near the surface, rising to a peak of .006/ohm meter at 250 km, dropping steeply inwards to a value of about .00005/ohm meter, and then rising toward the interior. A transition at 250 km depth from a high conductivity to a low conductivity material is inferred, suggesting an olivine-like core at approximately 800 C, although other models are possible.

Colburn, D. S.

Low-frequency flute instabilities of a bounded plasma column.

Derivation of exact solutions for unstable waves (called flute waves) which occur in a radially bounded plasma column at frequencies below the ion cyclotron frequency. Both analytical and numerical solutions are presented for the m = 1 and m = 2 azimuthal modes for a variety of radial electric field profiles. It is shown that the behavior of the flute waves can depend sensitively on the radial extent of the plasma column. Moreover, it is found that the m = 1 mode and the m = 2 mode do not respond in the same way to changes in the radial boundary position or in the electric field profile.

Rognlien, T. D.

A magnetohydrodynamic theory for the lunar response to time variations in a spatially uniform ambient magnetic field

An analytic theory based on principles of magnetohydrodynamics is derived for interpreting the lunar magnetic response to magnetic field fluctuations in the lobes of the geomagnetic tail. Only the case of magnetic perturbations parallel to a spatially uniform ambient magnetic field is treated. The theoretical frequency-dependent MHD transfer function depends on both the lunar electrical conductivity profile and the Alfven speed of the tail lobe plasma. For circular frequencies much less than the Alfven speed/lunar radius, the MHD transfer function reduces to the vacuum transfer function, while at higher frequencies the finite propagation speed of magnetic disturbances affects the response. These characteristics of the MHD transfer function are in qualitative agreement with observation. A carefully selected set of magnetic field transient events could be used together with this theory to infer lunar electrical conductivity profiles and the tail lobe plasma density (via its dependence on the Alfven speed).

Hood, L. L.

Self‐Potential Tomography Preconditioned by Particle Swarm Optimization—Application to Monitoring Hyporheic Exchange in a Bedrock River

Abstract A self‐potential (SP) data‐inversion algorithm was developed and tested on an analytical model of electrical‐potential profile data attributed to single and multiple polarized electrical sources. The developed algorithm was then validated by an application to SP‐monitoring field data measured on the floodplain of East Fork Poplar Creek, Oak Ridge, Tennessee, to image electrical sources in areas conducive to preferential flow into the flood plain from the bedrock‐lined riverbed. The algorithm combined stochastic source‐localization by particle‐swarm‐optimization (PSO) of electrical sources characterized by simplified geometries with source tomography by regularized weighted least‐squares minimization of a quadratic objective function. Prior information was incorporated by preconditioning the tomography algorithm by PSO results. Variable percentages of random noise were added to analytical‐model data to evaluate the algorithm performance. Results indicated that true parameters of single‐source models were inverted and approximated with small residual error, whereas inversion of analytical‐model data representing multiple electrical sources accurately approximated the locations of the sources but miscalculated some parameters because of the non‐uniqueness of the inverse‐model solution. Source tomography applied to analytical model data during testing produced a spatially continuous parameter field that identified the locations of point‐scale synthetic dipole sources of electrical current flow with varying degrees of accuracy depending on the prior information incorporated into the tomography. When applied to SP‐monitoring field data, the algorithm imaged electrical sources within a known fault that intersects the bedrock riverbed and flood plain of East Fork Poplar Creek and depicted dynamic electrical conditions attributed to hyporheic exchange.

54 ENVIRONMENTAL SCIENCES

Underlying Data for the EVI-RoadTrip Web Tool

The dataset contains simulation-based charging infrastructure outputs that are visualized on the EVI-RoadTrip webtool. The outputs are aggregated to lower spatial resolution (e.g., state-level, corridor-level).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

National Dataset of EV Charging Stations With Estimates of Load and Vehicle Throughput

Current data from the AFDC provide locations and many details about EV charging stations, but not estimates of their peak loads or the number of vehicles they can accommodate. This dataset will augment the AFDC charging station locations with estimates of transmission load and vehicle throughput based on engineering specifications of the chargers, charging patterns based on vehicle types, battery capacities, and user behavior.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

The detection of the electric field vertical distribution underneath thundercloud: Principle and applications

During the Florida 89 experiment at Kennedy Space Center, a new system was used in order to obtain the vertical distribution of the electric field underneath thunderstorms. It consists of a standard shutter field mill at ground level and five other field sensors suspended from a cable fastened to a tethered balloon located at an altitude of about 1000 meters. It also includes a reception station for telemetered information transmitted by sensors, a processing system in order to store data, and real time display on a screen to show the simultaneous field variations at each level along with the instantaneous electric field profile. The first results obtained show the great importance of the electric field vertical distribution. The field detected at a height of 600m reaches 65 kV/m while that at the surface does not exceed 5 kV/m. The field intensity in altitude is a better criterion for determining the right moment to launch a rocket devoted to flash triggering. Using Gauss's law, the simultaneous field variations at several levels are used in order to evaluate charge densities. Average values close to 1nC.m(-3) are calculated in layers up to 600 m. The calculation of different average charge densities leads to the characterization of the layer between cloud and ground just before the leader propagation in the case of cloud to ground flash.

Soula, Serge

Limits on the lunar temperature profile

Limits on the selenotherm are estimated using (1) a preferred set of bounds on the lunar electrical conductivity profile; (2) published laboratory conductivity vs. temperature data for an olivine and several aluminous orthopyroxenes; and (3) estimates for the Al2O3 content of the deep interior suggested by bulk composition models. The inferred limits are narrowest in the depth range 450 to 1350 km and are in accord with independent geophysical constraints. Thermal history models which yield present-day selenotherms that are in best agreement with these limits are those which permit subsolidus convection at depths greater than 800 km in the moon.

Hood, L. L.

Round Trip Energy Efficiency of NASA Glenn Regenerative Fuel Cell System

NASA Glenn Research Center (GRC) has recently demonstrated a Polymer Electrolyte Membrane (PEM) based hydrogen/oxygen regenerative fuel cell system (RFCS) that operated for a charge/discharge cycle with round trip efficiency (RTE) greater than 50 percent. The regenerative fuel cell system (RFCS) demonstrated closed loop energy storage over a pressure range of 90 to 190 psig. In charge mode, a constant electrical power profile of 7.1 kWe was absorbed by the RFCS and stored as pressurized hydrogen and oxygen gas. In discharge mode, the system delivered 3 to 4 kWe of electrical power along with product water. Fuel cell and electrolyzer power profiles and polarization performance are documented in this paper. Individual cell performance and the variation of cell voltages within the electrochemical stacks are also reported. Fuel cell efficiency, electrolyzer efficiency, and the system RTE were calculated from the test data and are included below.

Garcia, Christopher P.

Further efforts to limit lunar internal temperatures from electrical conductivity determinations

A representative set of 18 electrical conductivity profiles consistent with lunar transfer function data in the 0.00001 to 0.001 Hz range is generated by means of a Monte Carlo procedure. Laboratory electrical conductivity vs temperature data extrapolated to lower and higher temperatures are used to convert the 18 profiles into temperature profiles for a series of radially homogeneous olivine-pyroxene mixtures ranging from 100% olivine to 100% aluminous orthopyroxene. The former yields selenotherms approaching the Ringwood-Essene solidus at depths near 500 km, while additions of the latter in concentrations greater than 15-30 vol% leads to cooler selenotherms which approach the solidus only at depths greater than about 1000 km. On the basis of independent geophysical constraints, the profile envelopes for compositions containing more than 15-30 vol% aluminous orthopyroxene are considered to be the most probable.

Hood, L. L.