Simultaneous electrical resistivity and mass uptake measurements in bromine intercalated fibers

Changes in mass and electrical resistivity of several types of pitch-based and vapor-grown graphite fibers were monitored during reaction with bromine. The observed threshold pressure dependent reaction suggested that the fibers were intercalated. In the fully brominated compound, the mass was increased by 44 percent and the resistivity was improved by a factor of 17. In the residue compound, the mass was increased by 22 percent and the resistivity was improved by a factor of 5. Fibers possessing different degrees of graphitization had surprisingly similar changes in both mass and resistivity.

Jaworske, D. A.↗

Correlation of Electrical Resistance to CMC Stress-Strain and Fracture Behavior Under High Heat-Flux Thermal and Stress Gradients

Because SiCSiC ceramic matrix composites (CMCs) are under consideration for use as turbine engine hot-section components in extreme environments, it becomes necessary to investigate their performance and damage morphologies under complex loading and environmental conditions. Monitoring of electrical resistance (ER) has been shown as an effective tool for detecting damage accumulation of woven melt-infiltrated SiCSiC CMCs. However, ER change under complicated thermo-mechanical loading is not well understood. In this study a systematic approach is taken to determine the capabilities of ER as a relevant non-destructive evaluation technique for high heat-flux testing, including thermal gradients and localized stress concentrations. Room temperature and high temperature, laser-based tensile tests were conducted in which stress-dependent damage locations were determined using modal acoustic emission (AE) monitoring and compared to full-field strain mapping using digital image correlation (DIC). This information is then compared with the results of in-situ ER monitoring, post-test ER inspection and fractography in order to correlate ER response to convoluted loading conditions and damage evolution.

electrical resistance↗

Temperature dependence of the electron density of states and dc electrical resistivity of disordered binary alloys.

A model calculation of the temperature dependence of the electronic density of states and the electrical conductivity of disordered binary alloys, based on the coherent-potential approximation is made by introducing thermal disorder in the single-band model (Velicky and others). Thermal disorder is found to broaden and smear the static-alloy density of states. The electrical resistivity in weak-scattering alloys always increases with temperature. However, in the strong-scattering case, the temperature coefficient of resistivity can be positive, zero, or negative, depending on the location of the Fermi energy.-

Chen, A.-B.↗

Room temperature measurements of electrical resistivity and thermal conductivity of various graphites

Room temperature thermal conductivity measurements were completed on 10 graphite samples selected from the lot of 120 to uniformly span the range of electrical resistivity values. From these data and other measurements a thermal conductivity-electrical conductivity correlation was established to predict room temperature thermal conductivity values for the graphite samples. The correlation, expressed by a parabolic equation, represents available thermal and electrical conductivity data to about + or - 8%.

Mcelroy, D. L.↗

Thermal conductivity, electrical resistivity, and thermopower of aerospace alloys from 4 to 300 K. 6: Fe-22Cr-13Ni-5Mn stainless steel

The equipment and techniques for determining the thermal conductivity, electrical resistivity Lorenz ratio, and thermopower characteristics of Fe-22Cr-13Ni-5Mn stainless steel are discussed. The dimensions of the specimen and its preparation are described. The experimental data are represented by arbitrary functions over the entire range and smooth tables are generated from these functions.

Hust, J. G.↗

Electrical resistivity (4K to 2100K) of annealed vapor growth carbon fibers

Carbon fibers have been grown from methane gas, on iron seeded substrates at 1370 K, and subsequently annealed to a series of temperatures between 2800 K and 3475 K. The subsequent measurement of the electrical resistivity are reported as a function of temperature from 4 K to 2100 K. The two band model for the resistivity of graphite is well fit to the data, and results in physically reasonable parameters of the fits. The resistivity vs temperature results for two boron doped fibers are reported as well. The product of the resistivity times density for these fibers is lower than that product for any refractory metal, for temperatures above about 1000 K, suggesting the usefulness of these fibers as high temperature materials in space applications.

Ahmed, Akhter U.↗

Damage Characterization in SiC/SiC Composites using Electrical Resistance

SiC/SiC ceramic matrix composites (CMCs) under creep-rupture loading accumulate damage by means of local matrix cracks that typically form near a stress concentration, such as a 90o fiber tow or large matrix pore, and grow over time. Such damage is difficult to detect through conventional techniques. Electrical resistance changes can be correlated with matrix cracking to provide a means of damage detection. Sylramic-iBN fiber-reinforced SiC composites with both melt infiltrated (MI) and chemical vapor infiltrated (CVI) matrix types are compared here. Results for both systems exhibit an increase in resistance prior to fracture, which can be detected either in situ or post-damage.

Smith, Craig E.↗

Detecting Cracks in Ceramic Matrix Composites by Electrical Resistance

The majority of damage in SiC/SiC ceramic matrix composites subjected to monotonic tensile loads is in the form of distributed matrix cracks. These cracks initiate near stress concentrations, such as 90o fiber tows or large matrix pores and continue to accumulate with additional stress until matrix crack saturation is achieved. Such damage is difficult to detect with conventional nondestructive evaluation techniques (immersion ultrasonics, x-ray, etc.). Monitoring a specimen.s electrical resistance change provides an indirect approach for monitoring matrix crack density. Sylramic-iBN fiber- reinforced SiC composites with a melt infiltrated (MI) matrix were tensile tested at room temperature. Results showed an increase in resistance of more than 500% prior to fracture, which can be detected either in situ or post-damage. A relationship between resistance change and matrix crack density was also determined.