Engineering PapersSearch

SEARCH · Engineering Papers

Results for “electrical breakdown”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

178 records · Page 3

Cation valency in water-in-salt electrolytes alters the short- and long-range structure of the electrical double layer

Highly concentrated aqueous electrolytes (termed water-in-salt electrolytes, WiSEs) at solid-liquid interfaces are ubiquitous in myriad applications including biological signaling, electrosynthesis, and energy storage. This interface, known as the electrical double layer (EDL), has a different structure in WiSEs than in dilute electrolytes. Here, we investigate how divalent salts [zinc bis(trifluoromethylsulfonyl)imide, Zn(TFSI) 2 ], as well as mixtures of mono- and divalent salts [lithium bis(trifluoromethylsulfonyl)imide (LiTFSI) mixed with Zn(TFSI) 2 ], affect the short- and long-range structure of the EDL under confinement using a multimodal combination of scattering, spectroscopy, and surface forces measurements. Raman spectroscopy of bulk electrolytes suggests that the cation is closely associated with the anion regardless of valency. Wide-angle X-ray scattering reveals that all bulk electrolytes form ion clusters; however, the clusters are suppressed with increasing concentration of the divalent ion. To probe the EDL under confinement, we use a Surface Forces Apparatus and demonstrate that the thickness of the adsorbed layer of ions at the interface grows with increasing divalent ion concentration. Multiple interfacial layers form following this adlayer; their thicknesses appear dependent on anion size, rather than cation. Importantly, all electrolytes exhibit very long electrostatic decay lengths that are insensitive to valency. It is likely that in the WiSE regime, electrostatic screening is mediated by the formation of ion clusters rather than individual well-solvated ions. This work contributes to understanding the structure and charge-neutralization mechanism in this class of electrolytes and the interfacial behavior of mixed-electrolyte systems encountered in electrochemistry and biology.

Science & Technology - Other Topics

Electricity Markets and Long-Duration Energy Storage: A Survey of Grid Services and Revenue Streams

Purpose of Review Long Duration Energy Storage (LDES) is increasingly viewed as a potential resource for providing grid services that enhance the stability and flexibility of electricity systems. While some LDES services are integrated into existing market frameworks, traditional mechanisms may not fully account for their operational characteristics, potentially leading to undervaluation. Within this context, this paper reviews the literature and industry practices to assess potential grid services for LDES, evaluates existing compensation mechanisms, and identifies challenges to full market integration. Recent Findings We first review existing literature and identify key grid services unique to LDES, including enhancing grid resilience during extreme weather events, enabling long-term energy shifting, and providing flexible and firm energy in systems with limited dispatchable resources. Here, we also review how LDES services are compensated in current market frameworks and the challenges associated with the full realization of LDES values. Additionally, we summarize market mechanisms for storage technologies across U.S. wholesale markets. We find that some markets are adjusting incentive structures, such as incorporating storage duration in capacity accreditation, to better align with system needs and LDES contributions to the grid. However, further refinements in capacity remuneration and dispatch timeframes may be needed for more effective realization of LDES value. Summary This review evaluates potential grid services for LDES, examines existing compensation mechanisms for LDES technologies, and identifies gaps between these mechanisms and LDES operational characteristics. The review concludes by outlining potential market enhancements for more effective LDES integration and articulating additional research needs to support its efficient participation in future power systems.

Flexible resources

Utility Experience with Inverter Based Resource Impacts on Transmission Protection

High penetration of inverter-based resources (IBR) can adversely affect the transmission protection schemes in the area. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems because the existing system has been designed based on the fault current response of conventional rotating-machine-based generators. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. It includes a broad review of all challenges that system protection has experienced so far with high penetration of IBRs. Key issues have been identified based on a survey of different utility protection engineers. Finally, fault event recordings are shown to demonstrate some actual cases of mis-operations of relays near IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION

Reconfigurable structural color by reversible switching of colloidal discoid liquid crystal alignment

Combining the effects of alternating-current (AC) electric fields and sedimentation reconfigures colloidal discoids between planar and homeotropic orientational alignments, thereby controlling the material’s structural color. Here, we self-assemble micrometer-size polystyrene discoids in an isopropanol-water mixture. After sedimentation, the discoids adopt a homeotropic alignment, with the minor axis perpendicular to the substrate. Adding an AC electric field (1 kHz) of ≥0.50 V switches the discoids to planar alignment—with the minor axis parallel to the substrate—within ∼100 s. Removing the field switches them back to homeotropic alignment within ∼300 s. Kinetic modeling of the field-induced torques yields good agreement with these measurements. The peak wavelength and intensity of the crystal’s diffraction response shift significantly upon reconfiguration; scattering simulation predicts these shifts. The reconfiguration is maintained for at least 10 cycles. This method is a simple, scalable avenue to reconfigure the optical properties of colloidal crystals produced from simple dielectric spheroids.

colloidal crystals

In situ electric field X-ray total scattering reveals composition-dependent electromechanical strain mechanisms in (1 − x )BiFe 2/8 Ti 3/8 Mg 3/8 O 3 – x PbTiO 3 ceramics

Ferroelectric materials find many applications in energy and aerospace industries. A major challenge for ferroelectric materials is maintaining their properties at elevated temperatures. The (1 − x )BiFe 2/8 Ti 3/8 Mg 3/8 O 3 – x PbTiO 3 (BFTM–xPT) ferroelectric solid solution is a promising candidate for high-temperature applications as it has a high piezoelectric response while also maintaining its ferroelectric phase until a high Curie temperature (T C ) of 650 °C. In this work, we investigate the piezoelectric mechanism in BFTM–xPT, a novel high-T C ferroelectric ceramic. To elucidate the origin of its enhanced piezoelectric performance, relative to other piezoceramics of similar T C , in situ electric field X-ray total scattering experiments were performed. Total scattering combines Bragg scattering (diffraction) and diffuse scattering (pair distribution function), providing insight on various length scales. With information spanning different length scales, extrinsic contributions (i.e., domain wall motion and interphase boundary motion) can be separated from intrinsic contributions (i.e., piezoelectric lattice strain). We show that, for compositions within the morphotropic phase boundary (MPB, x = 0.325), the piezoelectric response is dominated by intrinsic piezoelectric lattice strain, whereas outside the MPB (x = 0.375) the major component of the piezoelectric response is from extrinsic mechanisms including an electric-field-induced phase transition and tetragonal domain wall motion. This article reveals that the origin of piezoelectric response in BFTM–xPT is composition-dependent and shows that high-performance materials may also be located outside the MPB. These findings can help guide material design to optimize properties for specific applications.

Richtik, Brooke N. [University of Calgary, AB (Can

Preliminary Evaluation of Joint Electricity-Hydrogen Concept of Operations

An initial thermal power dispatch (TPD) concept of operations was evaluated that couples a nuclear power plant to a nearby hydrogen production plant. GSE Systems’ generic pressurized water reactor full-scope simulator was modified with a TPD model comprised of a thermal power extraction and delivery system. A prototype human-system interface (HSI) was developed to interact with the TPD model and allow participants to execute the basic operating scenarios for normal operations. Four retired operators performed the evaluation, and due to COVID-19 travel restrictions, the original in-person experimental design was restructured to support a remote participator evaluation using a web meeting platform. Data from operator feedback, observations from the research team, and quantitative survey responses revealed that the initial TPD concept of operations is feasible. The operators were comfortable with the engineered system and HSI and could manage it without adverse impacts to reactor power, plant safety, or equipment. Findings are discussed in terms of both the TPD system design and HSI performance.

human factors

Measuring Climate and Water Risk across the Bulk Power System

As climate impacts increase and power systems transition to renewables, planners and operators need insights into climate risks to power generation and infrastructure to ensure reliable decision-making in the short and long-term. We present a standardized, consistent mechanism for utilities and system operators to evaluate the climate- and water-related risks of their current and future grid assets. Using a risk-based approach on the combined outcomes of high-fidelity climate drivers together with water and power system models, we examine the temperature and water availability impacts within the contiguous United States to power system assets at the water basin level in three different time periods and report resulting outcomes on lost capacity across different expansion scenarios and climate models. The results indicate that air temperature has the highest effect on derating. Changes in streamflow do not have a large impact on generation capacity at the national level. Electric sector buildout scenarios each have a unique regional risk profile, depending on the technology mix and total capacity, although risks from high temperatures are significant for both traditional and renewable energy generation. Stakeholders can use this approach to monitor effects of generation capacity losses and potential impacts as climate, generation mix, and infrastructure change.

24 POWER TRANSMISSION AND DISTRIBUTION

Small Co-doping induced magnetic and electrical transitions in single crystal CaF⁢e 0.95 ⁢C⁢o 0.05 ⁢O 3

CaFe⁢O 3 and CaF⁢e 0.95 ⁢C⁢o 0.05 ⁢O 3 single crystals were grown by combing floating-zone method with high oxygen pressure treatment. Both crystals show charge disproportionation of Fe (F⁡e 4+ → F⁡e 3+ + F⁡e 5+ ) accompanied by a metal-to-insulator transition as well as a crystal structural transformation from Pbnm to 𝑃⁢2 1 /𝑛. However, the slight introduction of Co significantly suppresses the critical temperature of charge disproportionation from 290 K in CaFe⁢O 3 to 260 K in CaF⁢e 0.95 ⁢C⁢o 0.05 ⁢O 3 . Different from the single antiferromagnetic phase transition as observed in the polycrystalline CaFe⁢O 3 , two sequential antiferromagnetic transitions are found to occur in these two single crystals with the Néel temperatures around 119 and 112 K for CaFe⁢O 3 crystal and 109 and 98 K for CaF⁢e 0.95 ⁢C⁢o 0.05 ⁢O 3 crystal, respectively. Neutron diffraction illustrates the formation of a spiral antiferromagnetic structure. Moreover, as the temperature further decreases to 65 K, a third magnetic transition accompanied by a second electrical transition is observed in the slightly Co-doped CaF⁢e 0.95 ⁢C⁢o 0.05 ⁢O 3 crystal. In conclusion, first-principles calculations suggest that the introduction of a moderate amount of Co and the peculiar spiral spin texture play an important role in the presence of such new magnetic and electrical transitions.

Xia, Hailiang [Chinese Academy of Sciences (CAS),

High-Q superconducting lumped-element resonators for low-mass axion searches

Low-frequency superconducting lumped-element resonators have recently attracted significant attention in the context of axion dark matter searches. Here, we present the design and implementation of a fixed-frequency superconducting resonator operating near 250 kHz, possessing an inductor volume of ∼1 liter and achieving an unloaded quality factor Q ≈ 2.1 × 10 6 . This resonator represents a significant improvement over the state of the art and informs the design of searches for low-mass axions.

Bosons

POWER ELECTRONICS GRID TIED SYSTEM FINAL REPORT

Across the country, electric utilities are grappling with the persistent hurdles of integrating Distributed Energy Resources (DERs). Managing these assets safely and effectively is a complex endeavor, complicated by varying ownership structures, management philosophies, and the diversity of the technologies themselves. Consequently, the industry has seen a proliferation of bespoke system designs, control strategies, and communication frameworks—forcing utilities to spend significant time and resources developing one-off integration solutions. This project addressed these integration hurdles through a scalable demonstration of intelligent devices designed to coordinate and control diverse resources in low-voltage applications. This concept minimized the need for complex integration by transforming the separate DERs into a dispatchable virtual power plant (VPP) with integrated resiliency functions (called a Node). By collaborating with a utility partner, the project focused on developing rapidly implementable use cases that bridged the gap between theoretical control and real-world deployment

99 GENERAL AND MISCELLANEOUS

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION

Hazard and risk analysis framework for nuclear power plant–based integrated energy systems

Employing integrated energy systems (IESs) with nuclear power plants (NPPs) can improve NPP utilization by leveraging dedicated thermal and electric power delivery, but it may also increase operational safety risks. This paper presents a framework to identify and quantify hazards and risks for such IESs. The framework combines accidentology to review past industrial accidents with failure modes and effects analysis (FMEA) to identify potential future incidents. Hydrogen explosion and toxic chemical release hazards are of particular concern. Explosion consequences are quantified using the Bauwens-Dorofeev (Bauwens) and trinitrotoluene equivalent mass (TNT-EM) methods, while chemical release consequences are computed using the Gaussian atmospheric dispersion method. Operational disturbances from direct electrical and thermal integration that may affect NPP safety are modeled using probabilistic risk analysis (PRA). Hazards and risks are then evaluated for regulatory compliance. The framework is applied to IESs comprising pressurized or boiling water reactors supplying three levels of thermal and electrical power to industrial customers. Case studies include high-temperature steam electrolysis hydrogen plants of varying capacities and a synthetic fuel production plant. Sensitivity analysis examines piping component failures in the PRA model as a precursor to cost estimation for thermal extraction line design. Additionally, Fussel-Vessely (FV) and risk increase importance (RII) measures identify risk-informed design improvements for the thermal extraction system. FMEA highlights hazards such as loss of offsite power, prompt loss of electrical load, loss of thermal output, and immediate steam diversion, in addition to hydrogen explosions and toxic chemical releases. Both Bauwens and TNT-EM methods suggest maintaining several hundred meters of separation between the NPP and hydrogen facility to mitigate explosion risks. PRA results show a maximum initiating event frequency increase of 1.15% and an overall risk increase of 0.28%. Importance measure analysis identifies upstream pipe leak isolation components as critical. Evaluating the results against safety regulations, it is concluded that hazards and risks can be managed to comply with regulations through risk-informed thermal and electrical connection designs, component selection, maintenance programs, and safe separation distances between NPPs and integrated industrial facilities.

08 - HYDROGEN

Ion Transport and Crystal Rotation in Plastic Crystal Electrolytes Under Applied Electric Fields

Organic ionic plastic crystal electrolytes, containing a plastic crystal and lithium salt, offer a potential balance between mechanical and electrochemical properties for solid state lithium-ion battery electrolytes. These electrolytes contain multiple mobile ionic species (three or four), resulting in complex transport mechanisms which have not yet been established. Plastic crystals are defined by long-range positional order and short-range rotational disorder. It is therefore necessary to quantify changes in the local crystal structure of the electrolyte as current flows through it. Herein, we examine the electrochemical properties of pyrrolidinium-based plastic crystal electrolytes containing lithium salt and zwitterion additives, including measurements of current fraction and limiting current. We obtain species-specific insight into electrolyte transport using pulsed-field gradient nuclear magnetic resonance spectroscopy and find that, while the zwitterion additive increases ionic conductivity, it decreases lithium diffusivity with respect to other ionic components. With operando spatiotemporally resolved wide-angle X-ray scattering we observe location-specific crystal rotations due to the passage of ionic current. In conclusion, we posit that reducing energy dissipation due to rotation is essential for using plastic crystal electrolytes in practical applications.

Yap, Kyra M. K. [University of California, Berkele

Analysis and Overview of Hybrid Wired and Wireless Bi-Directional EV Charger Systems

Here, this paper analyzes and overviews hybrid wired and wireless bi-directional Electric Vehicle (EV) charging systems with a primary focus on resonant compensation methods that enable a unified power conversion architecture. Four compensation configurations based on series–series and LCC–LCC resonant networks are systematically evaluated for both wired transformer-based and wireless coupler-based operation. The analysis examines how coupling conditions, resonant component selection, and auxiliary compensation tuning influence voltage gain characteristics, resonant tank current magnitude and phase, and operating frequency requirements. Normalized frequency-domain results are presented to directly compare reactive current behavior and voltage regulation capability under wired and wireless operating conditions. A 60 kW bi-directional charger case study is used to demonstrate the feasibility of retaining a common hardware platform while accommodating distinct coupling scenarios through compensation tuning rather than structural modification. The presented results provide design-oriented insights into resonant network selection and compensation strategies for scalable and flexible hybrid EV charging systems.

Hybrid

Theoretical design and performance of three-dimensional, pillared FeS 2 cathodes

Three-dimensional (3D) electrode design can provide improved capacities and rate capabilities over conventional two-dimensional electrodes by enhancing electrical and ionic transport. Here, expanding upon our previous modeling efforts for conversion chemistry lithium-ion batteries, we develop a pseudo-four-dimensional (P4D) approach that is subsequently used to investigate the design of a pillared FeS 2 electrode. The model considers transport in three dimensions with an additional “fourth” dimension corresponding to the solid-state lithium transport within the active material particles. Additionally, we allow for expansion of the active material during the conversion reaction to understand how internal stresses impact the electrochemical performance of the cell. By optimizing the model with respect to areal capacity, we are able to predict areal capacities up to 16.8 mAh/cm 2 for an areal current density of 1.78 mA/cm 2 and a 103% improvement for the three-dimensional electrodes over planar electrodes of equal volume. Despite the promising results, our simulations suggest that 3D design may be difficult for conversion cathode materials due to the large internal stresses that arise during conversion. Nevertheless, the model is robust and adaptable to other materials that may be more suitable for 3D electrodes due to a lesser change in volume during discharge.

Conversion cathode materials

Effectively Considering the Distribution System in Integrated Resource Plans

While electricity planning practices vary by state and utility based on utility type and market structure, integrated resource planning (IRP) remains a prominent vehicle — even in states with centrally-organized wholesale electricity markets. IRP focuses on meeting forecasted long-term electricity needs. Typically, utilities have not considered impacts of design and operation of the low-voltage distribution network in IRP. With advanced capabilities of grid-edge technologies to generate and store electricity and provide load flexibility, and large utility investments in distribution systems, it's increasingly important to consider at least some distribution planning elements in IRP. This report considers the value proposition for doing so, such as reducing utility costs through resource co-optimization and strategic siting of grid-edge resources, and idenfities the most important touchpoints between planning for bulk power and distribution systems and provide a range of tactics for integrating these two processes.

Relf, Grace [Lawrence Berkeley National Laboratory

Plant Engineers Solar Energy Handbook: Southern California Region

Discussed in order after the introduction are solar components and systems (collectors, storage, service hot water systems, space heating with liquid and air systems, space cooling, heat pumps and controls); computer programs for system optimization; local solar and weather data; a description of buildings and plants in Southern California applying solar technology; current Federal and California solar legislation; standards, codes and performance testing information; a listing of manufacturers, distributors, and professional services available in Southern California region; and information access. Finally, solar design check lists for those engineers who wish to design their own systems. The program for the Solar Workshop for the Plant Engineer, March 30, 1978, Los Angeles, California is included.

14 SOLAR ENERGY