Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric load profiles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

High-resolution hourly surrogate modeling framework for physics-based large-scale building stock modeling

Surrogate modeling can play a key role in reducing high computational burdens for large-scale physics-based modeling and uncertainty quantification. With the rapid development of large-scale building stock energy modeling, surrogate modeling has also begun to be widely applied in this field; however, most existing surrogate models lack hourly time resolution for regional-scale modeling, which is essential for understanding building demand profiles and grid impacts. Further, there is generally a lack of necessary data and feature engineering frameworks specific to building modeling for efficiently managing large datasets and complex computations. Furthermore, this paper proposes a modeling framework for large-scale (city-/region-scale), high-resolution, high-fidelity surrogate building stock energy models. Our developed framework consists of six modules: (1) building stock energy modeling (ComStock TM and ResStock TM ), (2) data engineering for large simulation data, (3) high performance computing workflow, (4) feature engineering, (5) machine learning model development, and (6) model performance evaluation. Two case studies apply the developed framework in both residential and commercial building stock analysis to demonstrate its computational efficiency and surrogate modeling accuracies. Results show that surrogate models, when efficiently trained using the HPC workflow module, reach a high level of modeling accuracy for two case studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving the Accuracy of Clustering Electric Utility Net Load Data using Dynamic Time Warping

Identifying patterns in electric utility net load data in a time-series format is very useful in preparing the operation for next day. Machine learning algorithms have been used in other domains and those concepts are applied in this paper on real-world net load measurement data. Clustering is the practice of grouping data with similar characteristics as determined by the distance measure. The K-means clustering algorithm is utilized here with actual electric utility data. The paper uses the standard distance measure, Euclidean distance (ED), and compares its performance against the dynamic time warping (DTW) measure. An actual case study with real data is presented, and DTW distance measure-based method observed to result better accuracy compared to the ED based method for substation net load measurements predominantly with residential customers.

clustering↗

Hourly Load Profile Dataset for Federal, State, and Municipal Electric Vehicle Fleets in the United States

The electrification of U.S. federal, state, and municipal fleets is accelerating rapidly, driven by an increased availability of competitive electric vehicle (EV) options and supportive policies and targets. The dataset described in this report, accessible at data.nrel.gov/submissions/280, provides a critical foundation for identifying fleet electricity demand, projecting these future demands, and developing actionable strategies to support the widespread electrification of government fleets. The dataset incorporates available fleet data, including 54% of federal agency vehicles approved for analysis (notably, the U.S. Postal Service is absent). Additionally, it includes data from 50,000 state government vehicles and 94,000 local government vehicles. While this represents a small fraction of the 4.4 million vehicles owned by state and local governments reported by the Federal Highway Administration (2022), the framework supports future expansion as more fleet inventory data become available.

33 ADVANCED PROPULSION SYSTEMS↗

Modeled Electricity Demand Profiles for Electric Transit Bus Depots in the United States

Hourly one-week electricity demand profiles for electric transit bus depots in the United States, as described in Liu et al. (2025). Please cite as: Liu, Bo, Tim Jonas, Kara Podkaminer, and Brennan Borlaug. 2025. Hourly Load Profile Dataset for Electric Transit Bus Depots in the United States. Golden, CO: National Renewable Energy Laboratory. NREL/TP-5400-92140. https://www.nlr.gov/docs/fy25osti/92140.pdf

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeled Electricity Demand Profiles for Federal, State, and Municipal Electric Vehicle Fleets in the United States

Federal, state, and municipal electric vehicle fleet hourly load datasets at the Uber H3 hex, county, and city resolutions, as described in Singer et al. (2025). Please cite as: Singer, Mark, Cabell Hodge, Kara Podkaminer, and Brennan Borlaug. 2025. Hourly Load Profile Dataset for Federal, State, and Municipal Electric Vehicle Fleets in the United States. Golden, CO: National Renewable Energy Laboratory. NREL/TP-5400-92142. https://www.nlr.gov/docs/fy25osti/92142.pdf

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detailed Laboratory Evaluation of Electric Demand Load Shifting Potential of Controlled Heat Pump Water Heaters

The demand profile management of electric end uses is vital research for utilities and policymakers planning greenhouse gas emission reductions. In this study, detailed laboratory research was conducted on the load shifting potential of 4 grid-connected HPWHs and one electric resistance water heaters (ERWH). The testing applied different CTA-2045 shed and critical peak command designs under three water draw profiles. Highly-controlled laboratory experiments were conducted in Florida. One of the four HPWHs was a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load-up above tank setpoint. A three-hour morning (6 – 9 AM) and four-hour evening curtailment (4 – 8 PM) were defined as the shed or critical peak periods reflecting high-value control periods for utility coincident load for system-wide electric demand reductions. Tests were performed under baseline conditions (no load shift) and under varied load-shifting schemes, including load up and advanced load up, ahead of shed and critical peak commands. Data were collected from December 2020 – February 2022 in the laboratory and compared with field experiments in Florida and the Pacific Northwest. Grid-connected HPWHs were found to reduce peak demand by up to 0.47 kW compared to uncontrolled HPWH units, depending on time of day, control scheme, draw profile, and temperature cluster. The load up strategy demonstrated the ability of all units to utilize heat pump mode for extended periods ahead of peak events. Demand reductions for the HPWHs were much larger when compared with the ERWH— up to 1.64 kW with large hot water draws in winter.

Fenaughty, Karen↗

Load Profiles Data for the EVI-RoadTrip Web Tool

The dataset contains EVI-RoadTrip outputs, minute-by-minute load profiles in kW for each station in the simulation based on assumed utilization and network density. The load profiles are aggregated to lower spatial resolution (e.g., state-level, corridor-level) by summation of all station loads associated with the respective geography. This results in a load profile for each scenario that summarizes the corridor's, state's, or county's load profile in minute-level resolution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detailed Evaluation of Electric Demand Load Shifting Potential of Heat Pump Water Heaters

Future utilities will emphasize home appliances to reduce greenhouse gas emissions while providing electric load shifting and demand profile management. Heat pump water heaters (HPWH) have demonstrated the ability to cut water heating energy by more than 65% compared with conventional electric resistance waters (ERWH). Laboratory research was conducted on the load shifting potential of grid-connected heat pump water heaters (HPWH), compared to ERWHs. Testing applied different CTA-2045 command designs. Highly-controlled laboratory experiments were conducted on one ERWH and four HPWHs, including a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load up above the tank setpoint. The prototype unit with the B-protocol increased tank temperature by 15oF (8.3C) under the advanced load up providing an increase of 1.8 kWh of storage for a 50-gallon (189 liter) tank. The prototype includes a built-in mixing valve to meet anti-scalding codes. With the load-shaping ability of CTA-2045-B, utilities might be able to store excess renewable energy in connected tanks when renewable wind and solar resource production is high. Tests were performed under baseline conditions (no load shift) and under several load-shifting schemes, including load up and advanced load up, ahead of shed commands. Grid-connected HPWHs reduced peak demand by as much as 0.5 kW, depending on tank volume, time of day, control scheme, and draw profile.

heat pump water heater, Demand flexibility, load s↗

Geographical variability of summer- and winter-dominant onshore wind

For each geographical region, one of the biggest challenges in reaching a zero-carbon grid is identifying sources of electricity that match the seasonal profile of the load. Summer-dominant solar electricity generation can often be balanced by winter-dominant wind electricity generation. Together with long-duration storage, balanced solar and wind generation are well positioned to provide reliable renewable electricity. However, in some locations the wind may not complement solar energy so well. For example, currently California's wind turbines produce more electricity during summer than winter, raising the question of whether all future wind plants in California will exhibit the same seasonality. As a response to this question, in this paper, we analyzed the generation from existing California wind plants and simulated potential onshore wind resource for the whole state using a metric that reflects the relative wind resource in winter. Our results indicate that the seasonality of the wind can vary for very small spatial difference with more than half of California showing stronger wind resource in the winter compared with the summer despite the current observation of the opposite trend. This study differentiates the seasonality of potential wind resources to inform the creation of a reliable, 100%-renewable-driven grid.

17 WIND ENERGY↗

A Physical Model Enhanced Data Driven Method for High-Resolution Residential Load Profile Generation

Residential buildings account for significant energy consumption, creating opportunities to offer grid services. As electric utilities seek to implement effective system operation strategies, understanding residential energy consumption patterns becomes essential; However, the time intervals of load profiles measured by utilities' smart meters are typically from 15 minutes to 60 minutes. The low-resolution data make it hard to extract appliance-level load information, which is critical for providing grid services. This paper presents a load profile generator designed to produce synthetic load profiles for residential buildings that emphasizes the importance of accurate representations of realistic energy consumption patterns. The generator takes realistic low-resolution residential load measurements and weather data as inputs, producing 1-minute interval profiles that match the characteristics of the original profiles. Further, this generator can be used to populate load profiles in areas where actual measurements are limited to improve the ability of utilities to analyze their distribution systems. By providing more high-resolution residential building load profiles, this tool supports electric utilities to enhance their residential building load control strategies and improve overall grid stability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Peak load reduction and load shaping in HVAC and refrigeration systems in commercial buildings by using a novel lightweight dynamic priority-based control strategy

Reducing peak power demand in a building can reduce electricity expenses for the building owner and contribute to the efficiency and reliability of the electrical power grid. For the building owner, reduced expenses come from the reduction or elimination of peak power charges on electricity bills. For the power system operator, reducing peak power demand leads to a more predictable load profile and reduces stress on the electric grid system. Herein we present a computationally inexpensive, dynamic, and retrofit-deployable control strategy to effect peak load reduction and load shaping. The effectiveness of the control strategy is examined in a simulation with 80 air-conditioning units and 40 refrigeration units. The results show that a peak demand reduction of 60 kW can be achieved relative to peak demand in a typical set point–based approach. The proposed strategy was deployed in a gymnasium building with four rooftop HVAC units, where it showed over 15% peak demand (kW) reduction savings while maintaining or lowering energy consumption (in kilowatt-hours) relative to the set point–based thermostat controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrifying education: Exploring the electrification potential of U.S. School bus fleets

We analyze the operations of 270 diesel school buses across the United States to assess their electrification potential and evaluate the impact of various charging strategies on electricity demand. We find that school buses typically follow a two-route schedule on weekdays, featuring extended dwell times between morning and evening trips. Weekday trip distances average 25 miles, while weekend trips average 42 miles. Charging simulations indicate over 90% of the U.S. school bus fleet could be electrified using current technologies (300-mile range at 1.21 kWh/mile with 19.2-kW depot charging) without modifying existing operating patterns. Depot charging is a key enabler of school bus electrification, however, the strategic placement of charging stations at other locations (e.g., schools) can further increase electrification potential. Additionally, we find electric school bus charging to be highly flexible, with charge management capable of reducing peak charging loads at depots by up to 77%.

24 POWER TRANSMISSION AND DISTRIBUTION↗